LabGruppen 10000q fp100f-10, 10000q fp100f-10 1 Service Bulletin

4.6 (7)
LabGruppen 10000q fp100f-10, 10000q fp100f-10 1 Service Bulletin

 

Document type:

Created:

Page:

 

 

SERVICE BULLETIN

(2011-10-11)

Page 1 of 2

 

 

 

 

Technical Service Bulletin No. 27

Created by: Lab.gruppen AB Service Department

Date: 2011-10-11

Reference no: C12

It is highly recommended to implement this service bulletin as preventative maintenance if the unit is serviced for another issue.

Affected models

FP+.

C16:4, C28:4, C48:4, C68:4, C88:4.

PLM10000Q, PLM14000.

Affected boards/modules

SP100FXXx-FXX

SP130FXXx-FXX

SP140F01a-FXX, SP140F01b-FXX

Symptom

Screaming sound from power supply if amplifier powers up.

Amplifier does not power up.

Solution

Replace capacitor C12 with either of below listed components.

Lab Part No.

Description

Amount

Info

Pos

6n8250VMMK5

Wima: FKS2 6800PF 10% 400VDC

1

 

C12

6n8250VMMK5

Epcos: B32529-C3682-K289

1

 

C12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S

2005 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN |.