KROHNE SU600Ex User Manual

Operating Instructions
SU 600 Ex
4 ... 20 mA signal conditioning instrument

Contents

Contents
1 About this document
1.1 Function .............................
1.2 Target group ..........................
2 For your safety
2.2 Appropriate use........................
2.3 Warning about misuse ...................
2.4 General safety instructions ................
2.5 CE conformity .........................
2.6 Safety information for Ex areas.............
3 Product description
3.1 Conguration..........................
3.3 Adjustment ...........................
4 Mounting
4 4 4
5 5 5 5 5 6
7 7 8 8
9 9
5 Connecting to power supply
5.3 Wiring plan ...........................
6 Setup with the integrated indicating and adjustment
unit
7 Maintenance and fault rectication
7.1 Maintenance ..........................
8 Dismounting
8.1 Dismounting procedure ..................
8.2 Disposal .............................
2 SU 600 Ex - 4 ... 20 mA signal conditioning
11 11 13
15 16 20
23 23 24
25 25
30653-EN-050803
9 Supplement
9.1 Technical data.........................
9.2 Dimensions ...........................
9.3 Certicate ............................
Contents
26 29 30
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 3
About this document

1 About this document

1.1 Function

This operating instructions manual has all the information you need for quick setup and safe operation of SU 600 Ex. Please read this manual before you start setup.

1.2 Target group

This operating instructions manual is directed to trained personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Information, tip, note
This symbol indicates helpful additional information.
Caution, warning, danger
This symbol informs you of a dangerous situation that could occur. Ignoring this cautionary note can impair the person and/ or the instrument.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
4 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
For your safety

2 For your safety

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator. For safety and warranty reasons, any internal work on the instruments must be carried out only by personnel authorised by the manufacturer.

2.2 Appropriate use

SU 600 Ex is a universal signal conditioning instrument and power supply unit for connection of a 4 20 mA/HART sensor.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.

2.4 General safety instructions

SU 600 Ex is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country-specic installation standards (e.g. the VDE regulations in Germany) as well as all prevailing safety regulations and accident prevention rules.

2.5 CE conformity

SU 600 ExisinCE conformity with EMC (89/336/EWG) and NSR (73/23/EWG).
Conformity has been judged acc. to the following standards:
l EMC:
- Emission DIN/EN 61326: 2004
- Susceptibility DIN/EN 61326: 2004 incl. supplement A
l NSR: EN 61010-1: 2001
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 5
For your safety
2.6 Safety information for Ex areas
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex­approved instruments.
6 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803

3 Product description

3.1 Conguration
Product description
Scope of delivery
Overview
The scope of delivery encompasses:
l Indicating and signal conditioning instrument SU 600 Ex l Mounting set l Ex separating chamber l Identication label l Documentation
- this operating instructions manual
- Ex specic safety instructions and, if necessary, further
certicates.
1
2
1
8
2 3
7
+
0
C
1
B
2
A
3
9
4
8
5
7
6
6
-
4
5
Fig. 1: SU 600 Ex 1 Status indications operating relay 1 and 2 2 Status indication fail safe relay 3 Status indication operation 4 [+/-] adjustment keys 5 Insertable tag for identication of the measurement loop 6 Function switch 7 Mode switch for sensor input (active/passive) on the rear of the instrument 8 LC display

3.2 Principle of operation

Area of application
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 7
SU 600 Ex is a universal single signal conditioning instrument
with integrated level switches and display for continuously measuring sensors. At the same time, it can serve as power
Product description
supply unit for connected sensors.SU 600 Ex is designed for connection of an individual 4 … 20 mA sensor. The instrument is suitable for carrier rail, panel and surface mounting.
Physical principle
Power supply
Packaging
SU 600 Ex signal conditioning instrument can power the connected sensor and also evaluate its measurement signals. The requested parameter is indicated in the display and, in addition, outputted to the integrated current output for further processing. Hence the measuring signal can be transmitted to a remote display or a connected control system. In addition, two level relays for control of pumps or other actuators are integrated.
Wide-range power supply unit with 20 … 253 VAC/DC for world-wide use.
You will nd detailed information on the power supply in the "Technical data" in the "Supplement".

3.3 Adjustment

The adjustment of SU 600 Ex is carried out via the integrated keys and a 16-step function switch.

3.4 Storage and transport

Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test acc. to DIN EN 24180.
The packaging of standard instruments consists of environ-
ment-friendly, recyclable cardboard. For special versions PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Storage and transport tem­perature
8 SU 600 Ex - 4 ... 20 mA signal conditioning
l Storage and transport temperature see "Supplement –
Technical data – Ambient conditions"
l Relative humidity 20 85 %
30653-EN-050803

4 Mounting

4.1 General instructions

Mounting
Installation location
Carrier rail mounting
You can mount theSU 600 Ex signal conditioning instrument onto a carrier rail 35x7.5 acc. to DIN EN 50022, or directly on the wall by means of the three screws or in a front panel or door of a switching cabinet.
Note:
Before mountingSU 600 Ex , set the requested mode of the measuring data input. With a slide switch on the rear of the instrument you can choose between active and passive current input (see also chapter " Connecting to power supply "). After mounting the instrument, the slide switch is no longer accessible.

4.2 Mounting information

1 Place the adapter plate [1] to the rear of SU 600 Ex (spring
of the adapter plate downward) and fasten the plate with screw [2](M4x6).
2 PlaceSU 600 Ex against the carrier rail [3] from below and
push the instrument upward until it snaps in.
21 3
61
43,5
Fig. 2: Carrier rail mounting 1 Adapter plate 2 Screw (M4x6) 3 Carrier rail
Wall mounting
1 Insert the metal strap [1] from above into the housing cut-
out.
2 Fasten the instrument directly to the wall with the three
screws (ø max. 4 mm).
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 9
Mounting
1
2
105
ø 4,5*
80
Fig. 3: Wall mounting 1 Metal strap 2 Covering slide switch active-passive
Panel mounting
1 Remove the pluggable terminal strips from the top and
bottom.
2 Screw pin [3] into the rear of SU 600 Ex and tighten with a
screwdriver.
3 Insert SU 600 Ex from the front into the front panel [1].
4 Place the clamping strap [2] from the back over the pin [3]
and pull it with the knurled nut [4] against the panel [1].
1
92
32 4
~90
Fig. 4: Panel mounting 1 Front panel 2 Terminal strap 3 Pin 4 Knurled nut
30653-EN-050803
10 SU 600 Ex - 4 ... 20 mA signal conditioning
Connecting to power supply

5 Connecting to power supply

5.1 Preparing the connection

Note safety instructions
Take note of safety
instructions for Ex applications
Select power supply
Select connection cable
Cable screening and ground-
ing
Always observe the following safety instructions:
l Connect only in the complete absence of line voltage l If overvoltages are expected, overvoltage arresters should
be installed.
In hazardous areas you should take note of the appropriate regulations, conformity and type approval certicates of the sensors and power supply units.
The power supply can be 20 253 VAC, 50/60 Hzor 20 253 VDC.
Power supply of SU 600 Ex is connected with standard cable acc. to the national installation standards.
Standard two-wire cable without screening can be used to connect sensors. If electromagnetic interference is expected, screened cable must be used.
Connect the cable screen on both ends to ground potential. In the sensor, the screen must be connected directly to the internal ground terminal. The ground terminal outside on the sensor housing must be connected to the potential equal­isation.
If potential equalisation currents are expected, the screen connection on SU 600 Ex must be made via a ceramic capacitor (e.g. 1 nF, 1500 V). The low frequency potential equalisation currents are thus suppressed, but the protective eect against high frequency interference signals remains.
Select connection cable for Ex applica- tions
Take note of the corresponding installation regulations for Ex applications. In particular, make sure that no potential equal­isation currents ow over the cable screen. In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation.

5.2 Connection procedure

Proceed as follows:
1 Mount SU 600 Ex
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 11
Connecting to power supply
2 Connect sensor cable to terminal 1 and 2, and where
applicable, connect the screen
3 Connect power supply (switched off) to terminal 5 and 6
4 Where applicable, connect fail safe and operating relay as
well as current output
The electrical connection is nished.
After connection, it is absolutely necessary to plug the blue Ex
separating chamber to terminals 1 and 2 (sensor input). This ensures the required distance of at least 50 mm (1.97 in) to other instruments.
1 Place the Ex separating chamber as shown below on the
terminals of the sensor input
2 Lead the sensor cable towards the front and out of the Ex
separating chamber
3 Push the Ex separating chamber towards the front until you
hear it snap in
12 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803

5.3 Wiring plan

Connecting to power supply
Overview
-
+
2
1
1 2
1
2
-
+
4
3
1
2
on
%
18 1716 15 1413 1211 10 9 876 5
3 4 5 6
Fig. 5: Terminal assignment SU 600 Ex 1 Measurement data input, optionally available with sensor power supply 2 Current output 3 Fail safe relay 4 Relay 2 5 Relay 1 6 Power supply
N- L1+
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 13
Connecting to power supply
Information:
Via the slide switch on the rear of the instrument you can switch over between active and passive operation of the measuring data input:
l In active mode,SU 600 Ex provides the power for the
connected sensors. Power supply and measurement data are transmitted over the same two-wire cable. This mode is provided for connection of transmitters without separate power supply (sensors in two-wire version).
l In passive mode, the sensors are not powered - only the
measured value is transmitted. This input is for transmitters with their own separate power supply (sensors in four-wire version). Furthermore,SU 600 Ex can be connected to an existing circuit like a standard current meter.
The position of the slide switch also inuences the precondi­tions for Ex implementation. Take note of the type approval certicate or the conformity certicate ofSU 600 Ex.
14 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803

Setup with the integrated indicating and adjustment unit

6 Setup with the integrated indicating and
adjustment unit

6.1 Adjustment system

The integrated indicating and adjustment unit is for measured value display, adjustment and diagnosis ofSU 600 Ex.
Indication and adjustment is carried out in the front via a clear LC-display and a function switch as well as two keys.
To open the cover, insert a screwdriver in the two slots on the
top and turn it slightly.
1
2
8
2 3
7
1
+
0
C
1
B
2
A
3
9
4
8
5
7
6
6
-
4
5
Fig. 6: Indicating and adjustment elements 1 Status indications operating relay 1 and 2 2 Status indication fail safe relay 3 Status indication operation 4 [+/-] adjustment keys 5 Insertable tag for identication of the measurement loop 6 Function switch 7 Mode switch for sensor input (active/passive) on the rear of the instrument 8 LC display
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 15
Setup with the integrated indicating and adjustment unit
Key functions
Set up
l [Function switch] for selection of:
- Adjustment
- Relay switching points
- Scaling
- Current output
- Integration time
- Oset correction
l [+/-] key:
- Change value of the parameter
By pushing the [+/-] key, you change the individual parameters of the selected function. In this phase, the processed parameter is ashing. By briey pushing the two keys simultaneously, you save your settings. "Save" is briey displayed.

6.2 Setup procedure

Setup encompasses mainly the adjustment of the measure­ment loop. A scaling of the measured value for the LC display and the adaptation of the relay switching points are additional settings. Additional setup steps might be, if necessary, setting an integration time to smooth the measured value or modifying the current output characteristics.
To clearly denote the measuring unit, the supplied labels can be inserted in the cover. In case several SU 600 Ex are used, each measurement loop should be clearly labelled.
Switch on phase
After being switched on, SU 600 Ex rst of all carries out a short self-check. The following steps are carried out:
l Internal check of the electronics l indication of the rmware version l the output signal jumps briey to the set fault current
Then the actual measured value is displayed and the corresponding current is transmitted to the current output.
Measured value indication
The measured value indication shows the digital indication value and also an analogue bargraph. Here, it is absolutely necessary that the function switch is set to position [ 0]
("OPERATE").
Function switch
16 SU 600 Ex - 4 ... 20 mA signal conditioning
The following functions can be selected via the rotary switch:
l 0: Measured value display and simulation l 1: Relay 1 switching point ON l 2: Relay 1 switching point OFF
30653-EN-050803
Oset correction
Setup with the integrated indicating and adjustment unit
l 3: Relay 2 switching point ON l 4: Relay 2 switching point OFF l 5: Decimal point position of the scaling l 6: Scaling for 100 % l 7: Scaling for 0 % l 8: Switch over current output 0/4 20 mA l 9: Damping of the measured value (integration time) l A: Oset correction l B: Min. adjustment in % by modifying the level l C: Max. adjustment in % by modifying the level l D: Min. adjustment in mA without modifying the level l E: Max. adjustment in mA without modifying the level l F: No function
When a pressure transmitter is used, an oset correction should be carried out rst. These instruments are factory-set in a certain position. If the pressure transmitter is now mounted in adifferent position, its measuring range is shifted slightly. The zero point is readjusted by carrying out the oset correction in uncovered (unpressurised) condition. The complete measur­ing range will be shifted by the deviating amount.
à Make sure that the pressure transmitter is completely
unpressurised, uncovered (unimmersed) and mounted in its nal position.
à Set the function switch to position [ A ]. The display
indicates now the actual sensor current in mA. Save the current status by pushing the [ +/- ] keys simultaneously.
Adjustment in mA without changing the level
For this adjustment procedure, two sensor current values (4 20 mA) must be entered corresponding to the levels 0 % and 100 %.
When using a pressure transmitter, an oset correction should be carried out to reach maximum accuracy. Carry out this oset correction before adjustment and with the sensor uncovered (unimmersed).
à Select now position [D] or [E] on the function switch, enter
the current values in mA for min. or max. adjustment and save your settings.
Adjustment in % by changing the level
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 17
During this adjustment procedure, the current level is assigned
to a certain percentage value. For this reason, percentage values that correspond to the actual lling levels must be entered for the min. and max. adjustment. The ideal calibration is at 0 % and 100 %. Because it is not always possible to empty or ll a vessel completely, any value can of course be
Setup with the integrated indicating and adjustment unit
entered. The greater the dierence between the two adjust­ment points, the more precise the measurement. It does not matter which value is entered rst.
à Select position [B] or [C] on the function switch, enter the
percentage values for the min. and max. adjustment and save your settings.
Relay outputs
Two operating relays are integrated inSU 600 Ex for level detection. First of all, determine at which switching points the relays should switch on and oagain. Furthermore you have to distinguish between the relay modes overll and dry run protection. You switch over by exchanging the ON/OFF values of the relay.
l Overll protection: Relay is switched owhen the max.
level is exceeded (safe currentless condition), relay is switched on again when the level falls below the min. level (switch on point < switch opoint).
l Dry run protection: Relay is switched owhen the level
falls below the min. level (safe currentless condition), relay is switched on again when the max. level is exceeded (switch on point > switch opoint).
à To adjust the on and oswitching points of relay 1, set the
function switch to position [1] or [2], enter the switching points for ON or OFF and save your settings. If necessary, proceed in the same way with relay 2 (position [3] or [4]).
18 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
Setup with the integrated indicating and adjustment unit
2
3
1 Level 2 Mode overll protection 3 Mode dry run protection
1
off (on)
on (off)
t
LED
on
off
on
off
Scaling
Scaling is the conversion of the measured value into a certain parameter or measuring unit. Instead of the percentage value, the volume can be displayed, e.g. in l. Indicating values between max.-9999 and +9999 are possible.
à First of all, determine the max. indicating range and the
number of decimal places after the decimal point -- max. four decimal places can be displayed. Select position [ 5 ] of the function switch, place the decimal point in the required position and save your settings.
à Now select position [6] or [7] on the function switch, enter
the requested values for 100 % or 0 % and save your settings.
Damping
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 19
To suppress uctuation in the measured value display, e.g.
caused by an agitated product surface, an integration time can be set. This time can be between 0 and 250 seconds. Keep in mind that this setting will increase the reaction time of the measurement, and that the reaction to quick changes of the measured value will be delayed. In general, a time of a few seconds is sucient to smooth the measured value display.
Setup with the integrated indicating and adjustment unit
à Now select position [9] on the function switch, enter the
requested value and save your settings.
Current output 0/4 20 mA
Simulation
Reset
The characteristics of the current output can be switched over from 4 20 mA to 0 20 mA.
à Now select position [8] on the function switch, adjust the
requested characteristics curve and save your settings.
To check if the settings ofSU 600 Ex are correct, the simulation mode can be used. Any individual measured value can be simulated and e.g. the correct behaviour of the relays and the connected instruments can be checked.
Switching over between the functions "OPERATE" and "Simulation" is done by pushing the [+/-] keys for at least 3
seconds.In the simulation mode, the set value ashes on the display. The simulation can be switched oby pushing both keys again for approx. 3 seconds. If no key is pushed, the display switches automatically over to "OPERATE" after approx. 60 minutes and the simulation is terminated.
à To start simulation, push the [ +/-] keys simultaneously until
the displayed value starts ashing (approx. 3 seconds). By pushing either of the [ +/-] keys, you can set the requested simulation value and make your check.
With a reset, all values set by the user will be lost and are reset to factory settings.
à Interrupt the power supply of SU 600 Ex. Push the [+/-]
keys simultaneously and hold them while you switch on the power supply. The display shows "RES" and the default settings will be restored. These are the following:
l Relay switch on points: 10 % l Relay switch opoints: 100 % l Decimal point: 888.8 l Display min: 0 l Display max: 100.0 l Integration time: 0 s l Oset correction: 0 l Current output: 4 20 mA l Min. adjustment: 0 % or 4 mA l Max. adjustment: 100 % or 20 mA
30653-EN-050803

6.3 Application example

l An upright cylindrical (linear) tank has a volume of 2700 l
20 SU 600 Ex - 4 ... 20 mA signal conditioning
General procedure
Setup with the integrated indicating and adjustment unit
l The max. lling volume is 2650 l, the min. lling volume 50 l l The level sensor in the vessel is a pressure transmitter
(passive), outputting a standardised 4 20 mA signal
l For further processing, an additional 4 20 mA output
signal is required
l The full and empty adjustment was carried out directly in
the sensor. The following values are outputted:
- max. volume (display max.) 20 mA = 2650 l
- min. volume (display min.) 4 mA = 50 l
l Relay 1 should switch on an emptying pump at a level of
90 % and switch othe pump at a level of 10 %
1 Select the following functions with the rotary switch.
2 Push one of the two [+/-] adjustment keys, the digital
indication ashes (if the rotary switch is set to "OPERATE", the [+/-] keys are inoperable).
3 Adjust the requested value with the [+/-] keys. If you hold
the key pushed, the digital indication changes the value more quickly.
4 Save your settings by pushing the [+/-] keys simultane-
ously.
Current output
à Set the function switch to position [8]. Select with the [+/-]
keys the measured value output 4 20 mA or 0 20 mA.
For this example, choose 4 – 20.
The displayed numbers have the following meanings:
l 0 – 20 = 0 … 20 mA l 4 – 20 = 4 … 20 mA
à Save the value by pushing the [+/-] keys simultaneously.
To scale the indication of SU 600 Ex, the lling volumes for 0 % and 100 %. The vessel does not have to be lled or emptied.
Scaled indication at 0 %
Scaled indication at 100 %
Decimal point
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 21
1 Set the function switch to position [7](display min.).
2 Set the value to 50 via the [+/-] keys.
3 Save the value by pushing both keys simultaneously.
1 Set the function switch to position [6](display max.).
2 Set the value to 2650 via the [+/-] keys.
3 Save the value by pushing both keys simultaneously.
Because the range of the example vessel is between 50 lto 2650 l, you will need all four positions of the digital indication.
Setup with the integrated indicating and adjustment unit
1 Set the function switch to position [5](Decimal Point).
2 By pushing the [+/-] keys, you move the decimal point.
3 Save the value by pushing both keys simultaneously.
Relay
l Set the function switch to position [ 1 ](relay 1 on). For the
given example, select the value 90.0 (90.0 %) with the [ +/- ] keys. The internal relay 1 then switches on when this value is reached. Save the value by pushing the two keys simultaneously.
l Set the function switch to position [ 2](relay 1 off). Select
the value 10.0 (10.0 %) with the [ +/-] keys. The internal relay 1 then switches owhen the value falls below this value. The respective relay control lamp lights when the relay is energized. If the switching points are too close together (<0.1 %), the appropriate LED ashes. The relay takes on the safe condition. In mode "OPERATE " an error message is outputted on the display.
l If you want to control additional relays, proceed in the same
way, as with relay 1. The switch positions for setting the respective relays are stated in the list of the function switch under "Setup procedure".
Note:
If you want to change the mode (i.e. the switching function of the relays), you have to exchange the On and Ovalues.
22 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
Maintenance and fault rectication
7 Maintenance and fault rectication

7.1 Maintenance

When used as directed in normal operation, SU 600 Exis completely maintenance-free.
7.2 Fault rectication
Causes of malfunction
Fault rectication
Fault messages
SU 600 Exoffers maximum reliability. Nevertheless faults can occur during operation. These may be caused by the following, e.g.:
l Measured value of the sensor not correct l Power supply l Interference on the cables
The rst measures to be taken are to check the input/output signals as well as to evaluate the error messages via the display. The procedure is described below. In many cases, the causes can be determined in this way and faults can be rectied.
? E003
l CRC-error
à Carry out a reset
à Return instrument for repair
? E014
l Short-circuit
à Eliminate short-circuit
à If necessary, exchange defective sensor
? E015
l Line break
à Repair sensor cable or replace it
à Check sensor connection
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 23
Maintenance and fault rectication
? E016
l Empty/full adjustment reversed
à Carry out a fresh adjustment
? E017
l Adjustment span too small
à Carry out a fresh adjustment and increase the distance
between min. and max. adjustment
? E021
l Scaling span too small
à Carry out a fresh scaling, increase the distance
between min. and max. scaling.
? E110
l Relay switching points too close together
à Increase the dierence between the two relay switching
points

7.3 Instrument repair

If a repair is necessary, please proceed as follows:
You can download a return form from our Internet homepage http://www.krohne-mar.com/leadmin/media-lounge/PDF- Download/Specimen_e.pdf.
By doing this you help us carry out the repair quickly and
without having to call back for needed information.
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof l Attach the completed form and possibly also a safety data
sheet to the instrument.
24 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
Dismounting

8 Dismounting

8.1 Dismounting procedure

Warning:
Before dismounting, be aware of dangerous process con­ditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc.
Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order.

8.2 Disposal

SU 600 Ex consists of materials which can be recycled by specialised recycling companies. We have purposely de­signed the electronic modules to be easily separable. Mark the instrument as scrap and dispose of it according to government regulations (electronic scrap ordinance, …).
Materials: see "Technical data"
If you cannot dispose of the instrument properly, please
contact us about disposal methods or return.
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 25
Supplement

9 Supplement

9.1 Technical data

General data
Series instrument for panel or wall mounting or
mounting on carrier rail 35x7.5 acc. to
EN 50022
Dimensions W = 96 mm (3.78 in), H = 104 mm (4.09 in),
D = 90 mm (3.54 in)
Weight approx. 400 g (0.88 lbs) Housing material plastic ABS/POM Screw terminals max. wire cross section 1.5 mm²
Power supply
Power supply 20 … 253 VAC, 50/60 Hz, 20 253 VDC Power consumption 12.4 VA, 4 W
S
ensor input
Number of sensors 1x 4 … 20 mA Kind of input (switch over)
- mode active sensor is powered by SU 600 Ex
- mode passive sensor has own power supply
Measured value transmission 4 … 20 mA analogue Terminal voltage mode active 19.5 … 14.5 V at 4 … 20 mA Current limitation mode active approx. 30 mA Inner resistance mode passive < 250 Ohm Detection line break <= 3.6 mA Detection shortcircuit >= 21 mA Adjustment range
- Empty adjustment 3.8 … 20.2 mA
- Full adjustment 4.1 … 20.5 mA
. adjustment delta 300 µA
- min
Connection cable 2-wire standard cable (screening recommen-
ded)
26 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
Supplement
Relay outputs
Quantity 2x operating relay, 1x fail safe relay Contact oating spdt Contact material AG NI 0.15 hard gold-plated Turn-on voltage min. 10 mVDC, max. 250 VAC/DC Switching current min. 10 µADC, max. 3 AAC, 1 ADC Breaking capacitance min 50 mW, max. 500 VA, max. 54 WDC Min. switching hysteresis 0.5 %
Current outputs
Quantity 1x output Range 0/4 20 mA Resolution 0.1 % or 20 µA Max
. load 500 Ohm Fault signal 22 mA Linearity error 0.1 % (relating to 20 mA) Temperature error 0.01 %/K (relating to 20 mA)
Displays
Measured value indication
- LC display (45x45 mm) digital and quasianalogue indication
- max. indicating range -9999 ... 9999
LED displays
- status indication operating voltage 1x LED green
- status indication fault signal 1x LED red
- status indication operating relay 1/22x LED yellow
Adjustment
Adjustment elements 2x keys in the front, 1x function switch, 1x slide
switch active-passive
Ambient conditions
Ambient temperature -20
+60°C (-4 +140°F)
Storage and transport temperature -40 +80°C (-40 +176°F)
Electrical protective measures
Protection
- Wall/rail mounting IP 20
- Panel mounting IP 40
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 27
Supplement
Overvoltage category II Protection class II
Electrical separating measures
Reliable separation acc. to VDE 0106 part 1 between power supply, sensor input and digital part
- Reference voltage 250 V
- insulation resistance 3.75 kV
Galvanic separation between relay output and digital part
- Reference voltage 250 V
- insulation resistance 4 kV
28 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803

9.2 Dimensions

Supplement
1
2
Fig. 7: Dimensions SU 600 Ex
")
")
")
8
64
/
8
/
/
3
1
5
92mm (3
111mm (4
102mm (4
69mm (2 23/32") 2mm (5/64")19mm (3/4")
%
96mm (3 25/32")
")
1
32
2
/
25
on
96mm (3
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 29
9.3 Certicate
CE declaration of conformity
Fig. 8: CE declaration of conformity
30 SU 600 Ex - 4 ... 20 mA signal conditioning
30653-EN-050803
30653-EN-050803
SU 600 Ex - 4 ... 20 mA signal conditioning 31
Subject to change without notice
30653-EN-050803
Loading...