® Electric Dryer
PRODUCT MODEL NUMBERS |
|
OVERALL DIMENSIONS |
KEYS700J KEYS750L
KEYS700L KEYS850J
KEYS710L KEYS850L
KEYS750J KEYS855J
Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60-Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30-ampere circuit, fused on both sides of the line. Use 10 gauge solid copper wire. A timedelay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
RECESSED AREA AND CLOSET INSTALLATION
|
" |
|
" |
29" |
" |
|
(73.66 cm) |
|
1
|
|
|
" |
|
|
|
" |
|
|
|
" |
" |
27 |
4" |
512" |
|
(70.5 cm) (14 cm) |
||
|
|
2 |
3 |
1.Recessed area
2.Side view - closet or confined area
3.Closet door with vents
"
1.Small Opening Side-Swing Door
2.Large Opening Side-Swing Door
3. Wide Opening Side-Swing Door
4. Wide Opening Hamper Door
"
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
EXHAUST VENTING
|
4" |
|
(10.2 cm) |
|
Box hood style |
4" |
|
(10.2 cm) |
2.5" |
|
(6.4 cm) |
4" |
|
(10.2 cm) |
Angled style |
Louvered style |
1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns.
2.Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
Vent Length Chart
Number of |
Type of |
Box or |
Angled |
90° turns |
vent |
Louvered |
hoods |
or elbows |
|
hoods |
|
|
|
|
|
0 |
Rigid metal |
64 ft (20 m) |
58 ft (17.7 m) |
|
Flexible metal |
36 ft (11 m) |
28 ft (8.5 m) |
|
|
|
|
1 |
Rigid metal |
54 ft (16.5 m) |
48 ft (14.6 m) |
|
Flexible metal |
31 ft (9.4 m) |
23 ft (7 m) |
|
|
|
|
2 |
Rigid metal |
44 ft (13.4 m) |
38 ft (11.6 m) |
|
Flexible metal |
27 ft (8.2 m) |
19 ft (5.8 m) |
|
|
|
|
3 |
Rigid metal |
35 ft (10.7 m) |
29 ft (8.8 m) |
|
Flexible metal |
25 ft (7.6 m) |
17 ft (5.2 m) |
•The number of elbows used.
•Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.
4 |
Rigid metal |
27 ft (8.2 m) |
21 ft (6.4 m) |
|
Flexible metal |
23 ft (7 m) |
15 ft (4.6 m) |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. 8535888 |