Read this manual thoroughly before using the CV-X290.
Always keep this manual in a safe place for future reference.
This manual describes the hardware information. Read this manual
thoroughly to understand how the CV-X290 works in order to maximize
the performance of the system.
• Always keep this manual in a safe location for future reference.
• Please ensure that the manual is passed to the end user of the
controller.
Symbols
The following symbols alert you to important messages. Be sure to read
these messages carefully.
DANGER
It indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE
Point
It indicates a situation which, if not avoided, could result in
product damage as well as property damage.
It indicates cautions and limitations that must be followed during
operation.
It indicates additional information on proper operation.
It indicates tips for better understanding or useful information.
Trademarks
• "SD Memory Card" is a registered trademark of the SD Association.
• Other company names and product names noted in this document are
registered trademarks or trademarks of their respective companies.
The TM mark and ® mark are omitted in this manual.
The equipment and accessories listed below are included in the package
when shipped. After opening the carton, check that you have received all
of the equipment and accessories listed below.
In order to connect a camera to this controller, a camera input
unit (sold separately; the CA-EC80L for high-pixel cameras, the
CA-EC80HX for HX Series cameras, the CA-EC80LJ for the LJV, or the CA-EC80 for area cameras) is required.
Safety Precautions
General Cautions
• Do not use this product for the purpose of protecting the
human body or any part thereof.
• Because this product was not designed for use in an
explosion-proof area, it must never be used in an explosionproof area.
• Before starting or operating the system, check to make sure
all system functions are working properly.
• If any Keyence product fails, take all safety precautions to
prevent damage before using the system again.
• If the system is operated beyond its published specifications
or if the system is modified, its functions and performance
cannot be guaranteed.
• Please note that when the system is used in combination
with other instruments, its functions and performance may
be degraded.
• Do not subject the controller or connected devices to a
sudden change in temperature.
There is the risk of condensation occurring.
General cautions for the controller
• Do not use with any power voltage other than 24 VDC. Doing
so may cause fire, electric shock, or product malfunction.
• Do not disassemble or modify the unit. Doing so may cause
fire or electric shock.
Operating environment and conditions
• To use the system properly and safely, avoid installing this unit
in the following locations. Doing so may cause fire, electric
shock, or product malfunction.
– Locations that contain moisture or dust, or that are
poorly ventilated.
– Locations where the system is exposed to direct
sunlight or temperature increases.
– Locations where there are flammable or corrosive
gases.
– Locations where the unit may be directly subjected to
vibration or impact.
– Locations where water, oil or chemicals may splash
onto the unit.
– Locations where static electricity is present or electric
discharge may occur.
• Keep this unit and cables away from high-tension cables and
power lines.
Otherwise, noise may cause malfunction or accidents.
• Bundle cables with spiral tubing material. Direct bundling will
NOTICE
concentrate the cable load on the bindings, which can result
in cable damage or short circuit.
• The controller and optional devices are precision
components. To maintain performance do not subject them
to vibration or shock.
Measures to be taken when an abnormality occurs
In the following cases, turn the power OFF immediately. Using
the unit in an abnormal condition may cause fire, electric shock,
or product malfunction. Contact your local Keyence office for
repair.
• If water or debris enters the system
• If the system is dropped or the case is damaged
• If smoke or a burning smell emits from the controller
Usage
• Before making any connections/disconnections, be sure to
turn off the power of this unit and connected devices. Failure
to do so may result in a malfunction of the controller or
connected devices.
• Do not turn the power off while you are programming.
Otherwise, all or part of the program settings may be lost.
• Do not block the ventilation holes. Otherwise, the inside
temperature may rise and a malfunction may occur.
• Do not allow an excessive amount of sunlight or bright indoor
light to enter the camera for a long period of time. Doing so
may cause damage to the image capture surface inside the
camera.
Maintenance
• Do not clean with benzene, thinner, or alcohol. Doing so may
NOTICE
cause discoloration or deformation of the unit.
• If the unit has any dirt on it, wipe it off with a cloth moistened
with a mild detergent, then wipe with a dry cloth.
Precautions on Regulations and Standards
CE Marking
KEYENCE evaluates compliance with the requirements of the EC
directive according to how products fulfill the below conditions. KEYENCE
has confirmed that this product meets these requirements. When this
product is used in EU nations, take note of the following precautions.
EMC Directive (2004/108/EC)
• Applicable standard EMI: EN61326-1, Class A
EMS: EN61326-1
• Use cables shorter than 30 m to connect the controller and its external
devices.
However, these precautions do not guarantee that the customer’s entire
machinery installation is compliant with the EMC Directive. The customer
is responsible for determining the compliance of the overall machinery
installation.
2
Identifying Controls and Connectors
NOTICE
NOTICE
With CA-EC80L installed
With CA-EC80LJ installed
햿Power and ground terminals
Use to connect power (24 V DC) and the ground wire.
헀Expansion unit connector 2 (left side)
Use to connect the illumination expansion unit CA-DC10E, CA-DC21E, or
CA-DC30E.
헁CAMERA1 connector
Use to connect the LJ-V as camera 1.
Installing the Controller Unit
Install the controller unit to DIN rail, or use the holes on the bottom of the
controller to secure it with screws.
• Do not install the controller in a location with lots of dust or
water vapor.
The controller does not have a mechanism to protect it from
dust or water. Dust or water entering the controller can cause
damage to the controller.
• Turn off the power to the controller when connecting or
removing an expansion unit, a cable, or a terminal block.
Connecting or removing the camera expansion unit, the
cable, or the terminal block while the power is being supplied
may damage the controller or peripheral devices.
• When an expansion unit is not connected, place the
connector protection cover back on the controller. Using the
controller with the connector exposed may cause damage to
the controller.
Caution on Direction of Controller Mounting
• Install the controller in the direction indicated by the circle shown below.
Do not install the controller in any other direction.
햲 Parallel I/O connector
Use to connect the parallel input/output signals.
햳 SD2 slot (upper), SD1 slot (lower)
Insert an SD card.
The lower slot (SD1) holds the included SD card (1 GB) by factory default.
Important
SD Card 1 must be inserted while the device is operating.
햴Camera slot
Use to connect the camera input unit.
(At the time of shipping, nothing is inserted in the slot.)
햵USB connector for the dedicated mouse
Use to connect the included dedicated mouse.
The USB port is used exclusively for the dedicated mouse (OP-
87506).
Connecting other equipment including a commercial USB
mouse can cause a malfunction or damage to the controller or
connected devices.
햶RGB output terminal
Use to connect to an external monitor.
햷USB connector
Use to connect a USB cable.
햸Expansion unit connector 1 (right side)
Use to connect the camera expansion unit (CA-E800).
햹Camera 1 connector
Use to connect camera 1.
햺TOUCH PANEL port
Use to connect an optional RS-232C cable for the touch panel (OP87258: 3m/OP-87259: 10m).
햻RS-232C port
Use to connect an optional RS-232C communication cable (OP-26487:
2.5m) or an optional RS-232C modular cable for touch panels
(OP-87264: 3m/OP-87265: 10m).
햽ETHERNET connector
Use to connect an Ethernet cable.
햾Terminal block
Use for signal input and output.
• For ventilation, keep the space free of objects for 50 mm or more above
the controller and 50 mm or more for both sides. Keep the space free of
objects for 90 mm or more in the front of the connector panel in order to
connect the cables safely.
• When two or more controllers are installed side by side, maintain 50
mm or more of space between the controllers, and 50 mm or more
above both controllers.
(Provide the same space when the controller and an LJ-V controller are
installed side by side.)
50 mm
50 mm
NOTICE
50 mm
50 mm50 mm
• Do not block the ventilation openings on the top and bottom
of the controller. If the vents are blocked, heat will
accumulate inside the controller and can cause a system
failure.
• When installing the controller on a surface, pierce holes in
the surface at the positions of the ventilation openings on the
bottom of the controller or perform similar operations to
ensure that there is ventilation from the bottom of the
controller to the top.
• If the temperature inside the control panel (temperature at
the bottom of the controller) exceeds the rating, use forced
air-cooling or increase the free space around the system to
improve ventilation until the operating ambient temperature
decreases below the rating.
3
Installing the Expansion Unit
When connecting
multiple units
OUT
IN
PO
WER
LIGHT 2
4
3
2
1
LIGHT 1
4
3
2
1
OUT
IN
PO
WER
LIGHT 2
4
3
2
1
LIGHT 1
4
3
2
1
Attachment
(supplied with
the CA-DC21E/CA-DC30E only)
Illumination
expansion unit
OUT
IN
PO
WER
LIGHT 2
4
3
2
1
LIGHT 1
4
3
2
1
NOTICE
NOTICE
Reference
Installing the Camera Expansion Unit
Use a camera expansion unit CA-E800
(sold separately) to which a camera
input unit has been connected in order
to increase the number of cameras to
connect.
Remove the protective cover of
connector 1 from the right side of the
controller, and then install the camera
expansion unit as shown on the right.
Installing the Illumination Expansion Unit
To control lighting from a controller, use an illumination expansion unit (sold
separately). One CA-DC10E unit (two individual lighting units), up to four
CA-DC21E units (eight individual lighting units), or up to two CA-DC30E
units (four individual lighting units) can be connected (you cannot connect a
mixture of the CA-DC10E with the CA-DC21E, or the CA-DC10E with the
CA-DC30E). Remove the protective cover of connector 2 from the left side
of the controller and install the illumination expansion unit as shown below.
Installing the Camera Input Unit
Install an optional camera input unit (the CA-EC80L for high-pixel cameras,
the CA-EC80HX for HX Series cameras, the CA-EC80LJ for the LJ-V, or the
CA-EC80 for area cameras) to the camera slot for the controller.
Make sure that there is no power to the controller before
NOTICE
connecting the camera input unit. Connecting the camera input
unit while connected to a power source may damage the unit or
controller.
The figure below explains the installation procedure for the
optional camera input unit CA-EC80L (for high-pixel cameras).
Use the same procedure to install the CA-EC80LJ (for the
LJ-V), the CA-HX80 (for CV-HX cameras), and the CA-EC80
(for area cameras).
1Remove the protective cover from the camera slot, and install
the camera input unit.
• Turn off the power to the controller when connecting or
removing a unit. Connecting or removing a unit while the
power is being supplied may damage the controller or
peripheral devices.
• If you will not connect units to the controller, do not remove
the connector protective cover from the controller. Using the
controller with the connector exposed may cause damage to
the controller.
• When mounting the illumination expansion unit (CA-DC21E
and CA-DC30E), always mount the supplied attachments.
The main unit and the illumination expansion unit can be
damaged if the supplied attachments are not mounted (the
CA-DC10E mounts directly to the controller without using the
attachments).
• Turn off the power to the illumination expansion unit when
removing the illumination head for the illumination expansion
unit CA-DC30E. Removing the illumination head while the
power is being supplied may damage the controller or
peripheral devices.
Installing the Controller
The controller unit and other units are
designed to be mounted on a DIN rail.
Pull the tab on the bottom in the direction
of the arrow to mount or dismount the
controller.
2Tighten the upper and lower screws of the camera input unit to
fix the unit.
NOTICE
Connecting the Camera Cables
Connect the camera to the camera connector of the controller unit using
one of the optional camera cables.
If connecting only a single camera, attach it to the CAM1 connector.
When connecting area cameras with the camera input unit CA-EC80
(for area cameras) attached
Tighten the screws to a torque of 1.5 Nm.
4
Ta b
Mount the controller in a stable location that is free from
vibration.
To CAM2 connector
To CAM1 connector
CAM1
CAM2
When connecting LJ-V with the camera input unit CA-EC80LJ (for
NOTICE
NOTICE
5.8 mm or
smaller
Circular connector
Connect 24 VDC here. Connect 0 V here.
Connect the ground wire
D-type ground (third ground)
(ground resistance 100 Ω)
A = B
D-type ground (third ground)
(ground resistance 100 Ω)
A > B
A < B
Device
Peripheral
Device
Peripheral
A
B
Device
Peripheral
A
B
Reference
Reference
LJ-V) attached
LJ-V Series Controller
(sold separately)
To CAM1
connector
• Bundle cables with spiral tubing material. Direct bundling will
concentrate the cable load on the bindings, which can result
in cable damage or a short circuit.
• In the absence of other specifications, the minimum cable
flexibility (R) should be 3 times the external diameter (5 times
is recommended). Additionally, repeated curvature and
screw stress should be avoided. The minimum bend radius is
the same, even when using high-flex cable. Unless otherwise
stated, use R100 or greater.
• Use the Ethernet cable for LJ-V connection (OP-87736) or a
commercial Ethernet cable (category 7 or above, or
10GBASE-T-compatible one) when connecting LJ-V.
• Do not connect the cables to other cameras. Doing so may
result in a malfunction.
Connecting the 24 VDC Power Source
• Use electrical wiring AWG14 to AWG22.
• Make sure to connect the frame ground terminal for the 24
VDC power source to a type D ground.
• The sizes of solderless connectors are shown below. Use
connectors that fit M3 screws.
• Tighten the screws with a torque of 0.5 to 0.75 Nm.
Y connector
5.8 mm or smaller
1Connect 24 VDC and 0 V to the power supply terminals.
2Connect the ground wire to the ground port.
• Ground each device separately.
• Use a D type ground.
• Keep ground resistance to 100 . or less.
NOTICE
• Keep the ground wire as shor t as possible.
• If it is not possible to ground each device separately,
ground them together. However, make sure that the
electrical cables are the same as shown below.
LJ-V Series Head
(sold separately)
Parallel I/O Interface
Connector Specifications
The specifications of the parallel
I/O connector for the controller
are as follows.
In normal situations, use the specialized parallel connection cable
(3 m) OP-51657 (option).
Pin layout: The cable colour when the OP-51657
(option) is used.
*1 It is the default assigned value on the terminal where the
signal assignment can be changed. These assignments
may vary if the Global settings have been changed.
*2 For more details about the signal description, see the "CV-X
Series User's Manual
No. Te r m in a l
name
1COMIN2–Connector input common
2IN0CMD_PARAM0Command parameter bit 0BRed
3IN1CMD_PARAM1Command parameter bit 1BOrange
4IN2CMD_PARAM2Command parameter bit 2BYellow
5IN3CMD_PARAM3Command parameter bit 3BGreen
6IN4CMD_PARAM4Command parameter bit 4BBlue
7IN5CMD_PARAM5Command parameter bit 5BPurple
8IN6CMD_PARAM6*1Command parameter bit 6 *1BGray
9IN7CMD_PARAM7*1Command parameter bit 7 *1BWhite
10IN8CMD_CODE0Command input bit 0BBlack
11IN9CMD_CODE1Command input bit 1BBrown
12IN10CMD_CODE2Command input bit 2BRed
13IN11CMD_CODE3Command input bit 3BOrange
14IN12CSTCommand execution inputBYellow
15IN13RESETResetBGreen
16IN14PST
17COMOUT2–Connector output common
18OUT0ACK
19OUT1NACK
20OUT2BUSY
21OUT3CMD_READYCommand input permissionDBrown
22OUT4READY1Trigger 1 input permissionDRed
23OUT5READY2Trigger 2 input permissionDOrange
24OUT6OUT_DATA0
25OUT7OUT_DATA1
26OUT8OUT_DATA2Data output bit 2DBlue
27OUT9OUT_DATA3Data output bit 3DPurple
28OUT10OUT_DATA4Data output bit 4DGray
29OUT11OUT_DATA5Data output bit 5DWhite
30OUT12OUT_DATA6Data output bit 6DBlack
31OUT13OUT_DATA7Data output bit 7DBrown
32OUT14OUT_DATA8Data output bit 8DRed
33OUT15OUT_DATA9Data output bit 9DOrange
34OUT16OUT_DATA10Data output bit 10DYellow
35OUT17OUT_DATA11Data output bit 11DGreen
36OUT18OUT_DATA12*1Data output bit 12
37OUT19OUT_DATA13*1Data output bit 13
38OUT20OUT_DATA14*1Data output bit 14
39OUT21OUT_DATA15*1Data output bit 15
40COMOUT2–Connector output common
SignalSignal Description
*1
*1
*1
*1
*1
*1
".
*2
terminal
Output data cycle input
terminal
Verification of successfully
executed command input
Verification of unsuccessfully
executed command input
Busy signal
Data output bit 0
Data output bit 1
terminal
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
Circuit
diagram
–Brown
BBlue
–Purple
DGray
DWhite
DBlack
DYellow
DGreen
DBlue
DPur ple
DGray
DWhite
–Black
Cable
colour
5
• COMOUT2 for Pin 17 and Pin 40 are common.
Reference
NOTICE
Reference
Reference
Reference
Reference
COM
OUT
Poly S
witch
• COMIN2 is a common terminal for input for the parallel I/O
connector.
• COMOUT2 is a common terminal for output for the parallel I/O
connector.
• Power source 0 V and COMIN1, COMIN2, COMOUT1,
COMOUT2, COMOUT_F+, and COMOUT_F- are all isolated.
Terminal Block Interface
Standard Specifications
Terminal block specifications for the controller are as follows.
Tightening with a force above the standard torque may cause
damage to the terminal block.
OUTPUT connector
• Socket block:
MC1.5/9-ST-3.5BK
(Phoenix Contact)
• Suitable wiring
AWG 16 - 28
• Terminal block screw torque
0.25 Nm or less
INPUT connector
• Socket block:
MC1.5/6-ST-3.5BK
(Phoenix Contact)
• Suitable wiring
AWG 16 - 28
• Terminal block screw torque
0.25 Nm or less
Pin Settings
*1: It is the default assigned value on the terminal where the
signal assignment can be changed. These assignments may
vary if the Global settings have been changed.
*2: For more details about the signal description, see the
Series User's Manual
OUTPUT connector
Term ina l
No.
name
1OUT22STOSTOOutput timing indicatorD
2OUT23ORORTotal status outputD
3F_OUT2 ERROR*1ERRError output
4F_OUT3 RUN
5COMOUT1–COMOUTCommon for terminal
6F_OUT0FLASH 1FLS1Strobe light output for
7F_OUT1FLASH 2FLS2Strobe light output for
8COMOUT_F+–(COMF+)+ common for terminal
9COMOUT_F-–(COMF-)- common for terminal
SignalTerminal block
display at time
of shipment
*1
RUNRun mode output
• Power source 0V, COMOUT1, COMOUT_F+, and
COMOUT_F- are all isolated.
• COMOUT1 is the common terminal for output for OUTPUT
connectors 1 to 2.
• COMOUT_F+ and COMOUT_F- are the common terminals for
OUTPUT connectors 3 to 4 and 6 to 7.
INPUT connector
Term ina l
No.
name
1COMIN1–COMINCommon for terminal
2IN15 PLC*1PLCCommand read request
3F_IN0TRG1TRG1Trigger 1 inputA
4F_IN1TRG2TRG2Trigger 2 inputA
5F_IN2TEST
6F_IN3EXT
SignalTerminal block
display at time
of shipment
*1
TESTTrial run input
*1
EXTDisable trigger input
• Power source 0V and COMIN1 are all isolated.
• COMIN1 is the common terminal for inputs 2 to 6.
".
Signal
description
block outputs
trigger 1
trigger 2
output
output
Signal
description
block inputs
from PLC
Input/Output Circuit
Input Circuit
Input circuit diagram
Circuit A (F_IN0 to 3 only, EV compatible)
• Max. imposed voltage: 26.4 V
• ON voltage: 10.8 V or greater
• ON current: 3 mA or greater
• OFF voltage: 5 V or less
• OFF current: 1 mA or less
COMIN1
Circuit B (other inputs)
• Max. imposed voltage: 26.4 V
• ON voltage: 10.8 V or greater
• ON current: 2 mA or greater
INPUT
• OFF voltage: 3 V or less
• OFF current: 0.3 mA or less
COMIN1
See "Parallel I/O Interface" (page 5) and "Terminal Block
Interface" (page 6) for common connections.
Output Circuit
6
Output circuit diagram (NPN output type)
NOTICE
Circuit C (F_OUT0 to 3 only)
• Max. imposed voltage: 30 V
• Leakage current: 50 mA
• Leakage current: 0.1 mA or
less
• Residual voltage:
"CV-X
1.4 V or less (50 mA)
1.0 V or less (20 mA)
Circuit D (Other outputs)
*2
Circuit
diagram
• Max. imposed voltage: 30 V
• Leakage current: 50 mA
• Leakage current: 0.1 mA or
less
*1
C
*1
C
–
C
C
–
–
• Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
Output circuit diagram (PNP output type, controllers with a "P" at
the end of the part number)
Circuit C (F_OUT0 to 3 only)
• Max. imposed voltage: 30 V
• Leakage current: 50 mA
• Leakage current: 0.1 mA or
less
• Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
Circuit D (Other outputs)
• Max. imposed voltage: 30 V
• Leakage current: 50 mA
*2
*1
*1
Circuit
diagram
–
B
A
*1
A
• Leakage current: 0.1 mA or
less
• Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
The overcurrent protective Poly Switch is set to trip at 1 A. Use a
power supply with an output rated 1 A or more.
COMOUT_F+
OUT
COMOUT_F-
COMOUT_F+
OUT
COMOUT_F-
COM
OUT
INPUT
Poly S
Poly Switch
witch
Poly S
3.3 kΩ
10 kΩ
6.2 kΩ
4.7 kΩ
witch
6
Main Specifications
Model name
Number of pixels
Camera input
Main processor for image processingMulti-core DSP (High-Speed)
Number of setting registrationsUp to 1000 settings (depending on SD card capacity and setting contents) for SD card 1 and SD card 2 individually and external switching is possible
Number of reference images
Memory card
Interface
Illumination control
Language
Rating
Environmental
resistance
WeightApprox. 1600g
*1 The letter at the end of the model number means the difference of the installed software function. For details, see the "CV-X Series User's Manual".
*2 The PNP open collector is used for model types with P at the end.
*3 Models that have an Ethernet port installed on the CPU unit support Ethernet port direct connections.
*4 The CA-DC21E supports switching between PWM and DC methods. The CA-DC30E is Constant current control method and the CA-DC10E is fixed to the PWM method.
*1*2
External trigger
Control input
Control output
Monitor output
Operation indicatorPower supply, operation, ERROR LED display
RS-232C
PLC-Link
Ethernet
USB
EtherNet/IP
PROFINET
MousePossible to control various menus via an optional dedicated mouse (OP-87506: included with the controller)
Touch panel
Power supply voltage24 V DC ± 10%
Current consumption
Ambient temperature0 to +45°C
Relative humidity35 to 85% RH (no condensation)
input
Control input16 points (4 of which support special function assignment) Input rating: 26.4 V max., 2 mA min.
Common output27 points (11 of which support special function assignment, includes 4 high speed outputs), NPN open collector, 50 mA max. (30 V max.)
Total status output 1 point, NPN open collector, 50 mA max. (30 V max.) Supports total status hold control, one-shot output (1 to 9999 ms)
• With CA-EC80LJ installed: 1 LJ-V or up to 2 with the expansion unit CA-E800 (Supports LJ-V7001/7001P)
• With CA-EC80L installed: 1 Colour/monochrome area camera or up to 2 with the expansion unit CA-E800 (Supports CA-H2100C/H2100M and
CA-HX500C/HX500M/HX200C/HX200M/HX048C/HX048M, mixed connection possible)
• With CA-EC80HX installed: 1 Colour/monochrome area camera or up to 2 with the expansion unit CA-E800 (Supports CA-HX500C/HX500M/
HX200C/HX200M/HX048C/HX048M, mixed connection possible)
• With CA-EC80 installed: 2 Colour/monochrome area cameras or up to 4 with the expansion unit CA-E800 (Supports CA-HX500C/HX500M/HX200C/
HX200M/HX048C/HX048M and CV-H500C/200C/S200C/H200C/H100C/035C/S035C/H035C/H500M/200M/S200M/H200M/H100M/035M/S035M/
H035M, mixed connection possible)
Each setting supports 400 images/LJ-V, 900 images/area camera (depending on SD card capacity), compress and save functions and image
registration of position adjusted images.
• SD card slot x2 (SDHC compatible)
• Supports OP-87133 (512 MB), CA-SD1G (1 GB: standard equipment on the SD1 slot), CA-SD4G (4 GB)
4 points (2 of which support special function assignment)
Input rating: 26.4 V max., 3 mA min., simultaneous/individual capture with up to 4 cameras is possible
Can set individual trigger delays (0 to 999 ms) for each trigger input
Analogue RGB output
XGA 1024 x 768 (24 bit colour, 60Hz)
Can perform numerical value output and control input/output or interface the CA series touch panel, supports a max. baud rate of up to 230400 bps
(Cannot be used with PLC-Links using the RS-232C port)
• Can output numerical values and perfor m control input/output using the Ethernet or RS-232C port
(Cannot be used in conjunction with EtherNet/IP and PROFINET. When using the RS-232C port, nonprocedural RS-232C communication cannot
be used in conjunction.)
• The following PLCs are supported via link unit:
KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series
Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series, FX Series (RS-232C only)
OMRON: SYSMAC C Series (RS-232C only), CJ/CS1/CP1 Series
YASKAWA Electric Corporation: MP900 Series (RS-232C only)/MP2000 Series
• Can output numerical values and perfor m control input/output
• Can output measured value and image data via the included PC programme, upload and download settings
• Supports FTP client and FTP server function
• VNC server (for non-PC clients, only displaying the monitor screen is supported)
• Supports BOOTP function
• 1000BASE-T/100BASE- TX/10BASE-T
• Can output measured value and image data via the included PC programme, upload and download settings
• USB 2.0 only.
• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / PROFINET).
• Cyclic (implicit) communication (max. 1436 bytes) possible. Message communication possible.
• Maximum connections: 32.
• In conformity with conformance test Version.CT10.
• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / EtherNet/IP).
• Cyclic communication (max. 1408 bytes) possible. Record data communication possible.
• In conformity with Conformance Class A
Possible to operate settings via CA series touch panel using TOUCH PANEL port or RS-232C por t
(When RS-232C is used, the nonprocedural communication and PLC-Links that use the RS-232C port cannot be used.)
By connecting the optional Illumination Expansion Unit CA-DC30E/21E/10E, lighting and intensity control for the LED illumination is possible.
CA-DC30E: 2ch/unit, up to 2 units can be connected, only suppor ts dedicated illumination unit.
CA-DC21E: 2ch/unit, up to 4 units can be connected, Output voltage 12V/24V.
CA-DC10E: 2ch/unit, up to 1 unit can be connected, Output voltage 12V only, mixed connection with CA-DC30E/21E is not possible.
Switched among English, Japanese, Simplified Chinese, Traditional Chinese, Korean, Thai, German, French, Italian, Mexican Spanish, Indonesian,
Vietnamese and Portuguese (Brazilian)
With area camera
3.6A (When 2 cameras are connected), 4.6A (When 4 cameras are connected)
With LJ-V connected
2.6A (1 unit connected), 2.8A (2 units connected)
Figures indicate maximum load including rush current at start-up.
*3
*4
7
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.
13191E 1104-1 96M13191 Printed in Japan
Dimensions
Depth:
Depth:
Depth:
Depth:
DIN-rail
mount
112
13223.5
35.965.3
83.3
116.7(85)
6
153
134.6
M4
Depth:11.0Depth:11.0
Depth: 6.0Depth: 6.08016.5
M4
M4M4
DIN-rail
mount
Controller Unit (CV-X290 + CA-EC80L)
Controller Unit (CV-X290 + CA-EC80LJ)
Unit: mm
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were used
merely to illustrate the general type and quality of the Products and not to
represent that the Products would necessarily conform to said models or
samples. Any Products found to be defective must be shipped to KEYENCE
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting
from any action of Buyer, including but not limited to improper installation,
improper interfacing, improper repair, unauthorized modification,
misapplication and mishandling, such as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not
warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF
PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM
LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE
COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS,
EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED
OF A POSSIBLE THIRD PARTY'S CLAIM FOR DAMAGES OR ANY OTHER
CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing
warranty disclaimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third
party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to
Buyer pertaining to the Products/Samples.
E 1101-3
With camera expansion unit CA-E800 and illumination
expansion unit CA-DC21E connected
8
Unit: mm
Unit: mm