Karcher HDS 995, HDS 1295 User Manual

HDS Super HDS 695 S HDS 745 HDS 895 S HDS 995 HDS 1195 HDS 1295
www.karcher.com
5.959 - 788 A2002029 (07/01)
HD S Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 2
HD S Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 3
10
11
13
14
15
12
16
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 4
CONTENTS
Environmental protection 4
Faults 11 Illustration of the unit 5 Operating controls 5 Note on the operating
instructions 6 Commissioning 6
Check the oil level 6 Filling with scale inhibitor 6 Filling with fuel 6 Filling with cleaning agent 6 Mounting handgun 6 Mounting handle 6 Water connection 6 Drawing in water from tank 7 Mains connection 7
Operation 7
Switching the unit on 7 Setting cleaning temperature 7 Setting operating pressure and flow rate 7 Measuring out the cleaning agent 8 Intended use 8 Cleaning 8 Operation with cold water 8 Operation with hot water 8 Operation with steam 8 Safety shut-off 9
Each time after usage 9 Reading the operating hours 9 Shut-down 9
Warranty 13
General information 13
Technical data 14
Spare Parts List 16
Prior to initial operation it is mandatory to
read the operating instructions and the
notes on safety no. 5.951-949!
Inform retailer immediately of any transport ation
damage.
ENVIRONMENTAL PROTECTION
Items used when working, such as fuel, oil,
cleaning agent and contaminated maintenance
materials, are to be deposited at a special
collection point.
Packaging materials, metal and plastic
containers are to be set aside for recycling as
appropriate.
Disposal of used units
Your Kärcher retailer will provide you with
information on disposal means harmless to the
environment.
Maintenance 9
Maintenance intervals 9
Maintenance tasks 10
Indicator lamp (item 28) motor/electronics module is lit 10 Cleaning strainer in water connection 10 Cleaning strainer in low water connection 10 Cleaning filter at cleaning-agent suction hose 10 Changing oil 10
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 5
ILLUSTRATION OF THE UNIT
CONTROL ELEMENTS
1 Fuel tank inlet 2 Handle 3 Instrument panel 4 Window with the maintenance/fault display (only HDS 995, HDS 1295) 5 Cover latch 6 Compartment für accessories 7 Short operating instructions 8 Cover for compartment 9 Unit cover 10 Cover for tank inlet 11 Tank inlet für scale inhibitor 12 tank inlet for cleaning agent 13 High-pressure nozzle 14 Handle grips in the chassis 15 Steel pipe 16 Pressure and flow control 17 Swivel caster with parking brake 18 Water inlet with strainer (coarse) 19 High-pressure connection 20 Handgun with high-pressure hose 22 Electric power cord
23 Unit switch
24 Temperature regulator
25 Fuel indicator lamp
26 Scale inhibitor indicator lamp
27 Indicator lamp-CHEM 1 , CHEM 2
(only HDS 1295)
28 Indicator lamp-engine
(all machines, except HDS Super)
29 Ready for working indicator lamp
30 Pressure gauge
31 Metering valve for cleaning agent
English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 6
NOTE ON THE OPERATING INSTRUCTIONS
All of the item numbers described below in the
Figure 3
operating instructions are referenced in the illustration of the unit.
Only fill with diesel fuel or light fuel oil.
It is forbidden to use unsuitable fuels,
COMMISSIONING
e.g. benzine (explosion hazard, damage to
unit).
Close tank cap
Wipe off excess fuel – Unit, piping, high-pressure hose and
connections must be in perfect working order!
Filling with cleaning agent
Lock the hand brake.
Checking oil level Figure 1
Contact Kärcher AFTER-SALES SERVICE immediately if oil is opaque!
If oil level is approaching MIN mark, fill up with oil as far as MAX mark. Seal oil filler inlet. Refer to technical data for oil grade.
Filling with scale inhibitor
Figure 2
(sample pack included with scope of delivery) Scale inhibitor stops heating coil becoming
calcified when using hard tap water. Is is metered in at the inlet in the water reservoir one drop at a time. The metering is set at the factory to medium­hard water. For other water hardness classes, call in Kärcher AFTER-SALES SERVICE to perform adjustment to local conditions.
Filling with fuel
* Only use Kärcher products.
* Never pour in solvent (petrol, acetone, thinner
etc.)!
* Avoid contact with eyes and skin
* Pay attention to cleaning-agent
manufacturer's instructions on saf ety and handling
Kärcher can provide an individual range of
cleaning and treatment agents.
Your dealer will be pleased to advise you.
Figure 4
Fill with cleaning agent
Mounting handgun
– Connect steel pipe (item 15) with handgun
(item 20)
Insert high-pressure nozzle in union nut
Mount and tighten unit nut
Mount the high-pressure hose to the high-
pressure connection.(Figure 6)
Mounting of spare high-pressure hose
Figure 5
Mounting handle
Figure 7
– Never operate unit with fuel tank empty! Fuel
pump would otherwise be destroyed!
Water connection
For connected loads, refer to Technical Data.
Install the supply hose to the water inlet
(item 18) of the unit.
(supply hose is not part of scope of delivery)