JBSYSTEMS LIGHT EC102, X0210 User Manual

0 (0)

Operation Manual EN

Mode d'emploi FR

Gebruiksaanwijzing NL

Bedienungsanleitung DU

Manual de instrucciones ES

Manual do utilizador PT

WWW.BEGLEC.COM

Copyright © 2007 by BEGLEC cva.

Reproduction or publication of the content in any manner, without express permission of the publisher, is prohibited.

Version: 1.0

EN - DISPOSAL OF THE DEVICE

Dispose of the unit and used batteries in an environment friendly manner according to your country regulations.

FR - DÉCLASSER L’APPAREIL

Débarrassez-vous de l’appareil et des piles usagées de manière écologique Conformément aux dispositions légales de votre pays.

NL - VERWIJDEREN VAN HET APPARAAT

Verwijder het toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften.

DU - ENTSORGUNG DES GERÄTS

Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes.

ES - DESHACERSE DEL APARATO

Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais.

PT - COMO DESFAZER-SE DA UNIDADE

Tente reciclar a unidade e as pilhas usadas respeitando o ambiente e em conformidade com as normas vigentes no seu país.

ENGLISH

 

 

 

 

 

 

OPERATION MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thank you for buying this JB Systems® product. To take full advantage of all possibilities, please read these operating instructions very carefully.

FEATURES

This unit is radio-interference suppressed. This appliance meets the requirements of the current European and national guidelines. Conformity has been established and the relevant statements and documents have been deposited by the manufacturer.

2-way stereo or 3-way mono crossover

Full scale frequency selection between 45 to 9600Hz

24dB/oct. Linkwitz - Riley filters

All inputs and outputs are balanced or unbalanced with XLR connections

Subsonic filter (40Hz) with ON/OFF switch

Gain control on all inputs and outputs

Phase inverter switch

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do not use the device and consult your dealer first.

Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user manual.

To protect the environment, please try to recycle the packing material as much as possible.

Check the contents:

Check that the carton contains the following items:

User manual

Power Cable

EC102/XO210 unit

SAFETY INSTRUCTIONS:

CAUTION

CAUTION: To reduce the risk of electric shock, do not remove

the top cover. No user-serviceable parts inside. Refer

 

servicing to qualified service personnel only.

 

The lightning flash with arrowhead symbol within the

 

equilateral triangle is intended to alert the use or the presence

of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance.

This symbol means: indoor use only.

This symbol means: Read instructions.

ENGLISH

OPERATION MANUAL

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be placed on this appliance. Electric shock or malfunction may result. If a foreign object enters the unit, immediately disconnect the mains power.

No naked flame sources, such as lighted candles, should be placed on the appliance.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 45°C. Don’t use this unit at higher ambient temperatures.

Always unplug the unit when it is not used for a longer time or before you start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The socket inlet shall remain operable for disconnection from the mains.

The power cord should always be in perfect condition. Switch the unit immediately off when the power cord is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Never let the power-cord come into contact with other cables!

When the power switch is in OFF position, this unit is not completely disconnected from the mains!

This appliance must be earthed to in order comply with safety regulations.

In order to prevent electric shock, do not open the cover. Apart from the mains fuse there are no user serviceable parts inside.

Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same type and electrical specifications!

In the event of serious operating problems, stop using the appliance and contact your dealer immediately.

Please use the original packing when the device is to be transported.

Due to safety reasons it is prohibited to make unauthorized modifications to the unit.

INSTALLATION GUIDELINES:

Install the unit in a well-ventilated location where it will not be exposed to high temperatures or humidity.

Placing and using the unit for long periods near heat-generating sources such as amplifiers, spotlights, etc. will affect its performance and may even damage the unit.

The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes on the front panel. Be

sure

to

use

screws

of

the

appropriate

size.

(screws

not

provided)

Take care to minimize shocks and vibrations during transport.

 

 

 

 

When installed in a booth or flight case, please make sure to have good ventilation to improve heat evacuation of the unit.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance.

CLEANING THE APPLIANCE:

Clean by wiping with a polished cloth slightly dipped with water. Avoid getting water inside the unit. Do not use volatile liquids such as benzene or thinner which will damage the unit.

JB SYSTEMS®

1/30

EC102/XO210

JB SYSTEMS®

2/30

EC102/XO210

JBSYSTEMS LIGHT EC102, X0210 User Manual

ENGLISH

OPERATION MANUAL

CONNECTIONS

Use good quality cables to prevent bad audio quality.

For more information on connections, please refer to the next chapter and the picture below. Be sure to turn off the equipment before you make changes to the different connections.

In this manual we talk about “line inputs”. This is a global name for inputs with a level between 750mV and 2V. This includes tuners, videos, CD-players, etc.

FUNCTIONS (FRONT)

1.Input Gain: Controls the INPUT level with +/- 12dB.

2.Low Cut Switch: Push this button to select the 40 Hz high pass filter. Use this filter to protect your speakers and amplifier from unwanted subfrequencies that only consume power but don’t necessarily add more punch

3.Crossover Point selection: Selects the crossover point between:

In Stereo mode: LOW and HIGH frequencies

In Mono mode: LOW and MID frequencies on the Channel 1

MID and HIGH frequencies on the Channel 2 4. X10 LED: X10 LED off: you can control the x-over frequency from 45Hz to 960Hz

X10 LED on: you can control the x-over frequency from 450Hz to 9.6kHz

ENGLISH

OPERATION MANUAL

5.LOW/MID Output: Controls the:

In Stereo mode: LOW frequency output level from - ∞ to +6dB ( both channels )

In Mono mode:

LOW frequency output level from - ∞ to +6dB on Channel 1 MID frequency output level from - ∞ to +6dB on Channel 2

6.LOW/MID Phase Invert Switch: Switch for inversing the polarity. A LED indicates your selection:

In Stereo mode: you can inverse the polarity on the LOW output

In Mono mode:

you can inverse the polarity on the LOW output on Channel 1 you can inverse the polarity on the MID output on Channel 2

Remark: Use this switch with care. This switch is most effective on the low frequencies: switch the inverter on/off while listening to the music. Choose the position with the most bass reproduction

7.HIGH Output: controls the HIGH frequency output level from - ∞ to +6dB. When you work in Mono mode, you can only use the Channel 2 knob.

8.HIGH Phase Invert Switch: Switch for inversing the polarity on the HIGH output. A LED indicates your selection. When you work in Mono mode, you can only use the switch on Channel 2.

Remark: In most cases you don’t need to use this switch. When the setting is wrong, it can bring you more bad then good

9.MONO/STEREO LED: This LED indicates if you are working in MONO or STEREO Mode:

MONO Mode: Both channels work together to obtain a 3-way mode crossover

STEREO Mode: Both channels work independently to obtain an 2x2-way crossover

10.Power Switch: Switch for turning the unit ON/OFF

FUNCTIONS (rear)

11.Mains Input: with IEC socket and integrated fuse holder, connect the supplied mains cable here

12.Ground Lift Switch: In some cases nasty hum noises can occur due to ground loops in your setup. Setting the Ground Lift Switch to the position “lift” breaks the ground loop between the EC102/XO210 and the chassis grounds of various other components in your setup. As a result the hum noises will disappear.

13.XLR Inputs: Balanced inputs using XLR cables. When you work in Mono Mode, you only have to connect an XLR cable on Channel one

14.LOW/MID XLR Output: Balanced outputs using XLR cables:

In Stereo Mode: When you work in Normal mode ( see number 17 for more information ), you have to connect an XLR cable to Channels 1 and 2. When you work in Summed mode, you only have to connect an XLR cable to Channel 1.

In Mono Mode: Channel 1 operates the LOW output.

Channel 2 operates the MID output.

15.HIGH XLR Output: Balanced outputs using XLR cables:

In Stereo Mode: You have to connect an XLR cable to both channels

In Mono Mode: Only Channel 2 is used

16.MONO/STEREO Switch: With this switch, you can choose between MONO 3-way or STEREO 2x2-way Mode

17.LF SUM Switch: With this switch, you can choose if you want your LOW frequencies in normal mode ( 2 outputs ), or summed ( uses only channel 1 output ) ( see number 14 for more information ). In summed mode the low frequency from Channels 1&2 are put together so you don’t have to use a splitter cable in case you have only 1 subwoofer.

JB SYSTEMS®

3/30

EC102/XO210

JB SYSTEMS®

4/30

EC102/XO210

ENGLISH

OPERATION MANUAL

18.Crossover Frequency Switch: With this switch, you can choose between x1/x10 frequency range ( see number 4 for more information )

SPECIFICATIONS

Power Supply:

AC 230 V, 50Hz

Fuse:

20mm glass fuse 250V 500mA slow

Frequency response:

20Hz to 20kHz, +0/-0.5 dB

THD + noise:

<0.004% @ 1kHz, 4dB

S/N Ratio (IHF-A):

>90dB @ 1kHz.

Line inputs:

1V @ 10kΩ

Outputs:

1V @ 600Ω

CrossoverFrequencies:

45 – 960 Hz ( normal mode )

 

450 – 9600 Hz ( x10 mode )

Dimensions:

483(W) x 44(H) x 136(D) mm

Weight:

2kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

FRANCAIS

 

MODE D’EMPLOI

 

 

 

 

 

 

Nous vous remercions d’avoir acheté ce produit JB Systems®. Veuillez lire ce mode d’emploi très attentivement afin de pouvoir exploiter toutes les possibilités de cet appareil.

CARACTERISTIQUES

Cet appareil ne produit pas d’interférences radio. Il répond aux exigences nationales et européennes. La conformité a été établie et les déclarations et documents correspondants ont été déposés par le fabricant.

Filtre actif: 2-voies stereo ou 3-voies mono

Sélection complète des fréquences de 45 Hz à 9600 Hz

Filtres Linkwitz-Riley 24dB/oct.

Chaque entrée et sortie en XLR ( toujours balance ou non-balancée )

Filtre subsonique 40 Hz ( avec interrupteur marche/arrêt )

Réglage du GAIN pour chaque entrée et chaque sortie

Interrupteur pour inversion de ‘Phase’

AVANT L’UTILISATION

Quelques instructions importantes:

Avant d’utiliser cet appareil, assurez-vous de l’absence de dommage lié au transport. En cas d’endommagement, n’utilisez pas l’appareil et contactez le vendeur.

Important: Cet appareil a quitté notre usine en parfaite condition et bien emballé. Il est primordial que l’utilisateur suive les instructions de sécurité et avertissements inclus dans ce manuel. La garantie ne s’applique pas en cas de dommage lié à une utilisation incorrecte. Le vendeur ne prend pas la responsabilité des défauts ou de tout problème résultant du fait de n’avoir pas tenu compte des mises en garde de ce manuel.

Conservez ce manuel dans un endroit sûr pour toute consultation future. Si vous vendez l’appareil, assurez-vous d’y joindre ce manuel également.

Afin de protéger l’environnement, merci de recycler les emballages autant que possible.

Vérifiez le contenu:

Vérifiez si la boite contient les articles suivants :

Mode d’emploi

Câble secteur.

EC102/XO210

INSTRUCTIONS DE SECURITE:

ATTENTION: afin de réduire le risque d’électrocution, CAUTION n’enlevez jamais le couvercle de l’appareil. Il n’y a aucune pièce à l’intérieur de l’appareil que vous pouvez remplacer vous-même. Confiez l’entretien uniquement à des techniciens

qualifiés.

La flèche dans un triangle met l'utilisateur en garde contre la présence de haute tension sans isolation dans l'appareil qui peut causer un risque d'électrocution.

Un point d'exclamation dans un triangle prévient de la présence d'instructions de fonctionnement et de maintenance se trouvant dans le manuel, fourni avec l'appareil.

Ce symbole signifie : uniquement pour usage à l'intérieur

Ce symbole signifie : Lire le mode d’emploi.

JB SYSTEMS®

5/30

EC102/XO210

JB SYSTEMS®

6/30

EC102/XO210

FRANCAIS

MODE D’EMPLOI

Afin d’éviter tout risque d’incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou l’humidité.

Pour éviter la formation de condensation à l’intérieur de l’appareil, patientez quelques minutes pour laisser l’appareil s’adapter à la température ambiante lorsqu’il arrive dans une pièce chauffée après le transport. La condensation empêche l’unité de fonctionner en performance optimale et peut même causer des dommages.

Cette unité est destinée à une utilisation à l’intérieur uniquement.

Ne pas insérer d’objet métallique ou verser un liquide dans l’appareil. Aucun objet rempli de liquides, tels que des vases, ne peut être placé sur cet appareil. Risque de choc électrique ou de dysfonctionnement. Si un corps étranger est introduit dans l’unité, déconnectez immédiatement de la source d’alimentation.

Aucune source de flamme nue, telle que les bougies allumées, ne peut être placée sur l'appareil.

Ne pas couvrir les ouvertures de ventilation, un risque de surchauffe en résulterait.

Ne pas utiliser dans un environnement poussiéreux et nettoyez l’unité régulièrement.

Ne pas laisser l’unité à portée des enfants.

Les personnes non expérimentées ne doivent pas utiliser cet appareil.

La température ambiante maximum d’utilisation de l’appareil est de 45°C. Ne pas l’utiliser au-delà de cette température.

Débranchez toujours l’appareil si vous ne l’utilisez pas de manière prolongée ou avant d’entreprendre des réparations.

Les installations électriques ne peuvent être faites que par du personnel qualifié et conformément aux régulations de sécurité électrique et mécanique en vigueur dans votre pays.

Assurez-vous que la tension d’alimentation de la source d’alimentation de la zone dans laquelle vous vous trouvez ne dépasse pas celui indiqué à l’arrière de l’appareil.

La prise sera toujours accessible pour que le cordon secteur puisse être enlevé à chaque moment.

Le cordon d’alimentation doit toujours être en parfait état. Mettez immédiatement l’unité hors tension si le

cordon devait être écrasé ou endommagé. Pour éviter tout risque de choc électrique, le cordon doit être remplacé par le constructeur, son agent ou un technicien qualifié.

Ne laissez jamais le cordon d’alimentation entrer en contact avec d’autres câbles !

Quand l’interrupteur principal est dans la position OFF, cet appareil n'est pas complètement isolé du courant 230V!

L’appareil doit être à la masse selon les règles de sécurités.

Utilisez toujours les câbles appropriés et certifiés lorsque vous installez l’unité.

Pour éviter tout choc électrique, ne pas ouvrir l’appareil. En dehors du fusible principal, il n’y a pas de pièces pouvant être changées par l’utilisateur à l’intérieur.

Ne jamais réparer ou court-circuiter un fusible. Remplacez systématiquement un fusible endommagé par un fusible et de mêmes type et spécifications électriques !

En cas de problèmes de fonctionnement sérieux, arrêtez toute utilisation de l’appareil et contactez votre revendeur immédiatement.

Utilisez l’emballage d’origine si l’appareil doit être transporté.

Pour des raisons de sécurité, il est interdit d’apporter toute modification à l’unité non spécifiquement autorisée par les parties responsables.

CONSEILS D'INSTALLATION:

Installer l'appareil dans un lieu bien aéré, à l'abri de l'humidité et des fortes températures.

Placer et utiliser l'appareil à proximité de sources de chaleur telles que spots, amplis,… pourrait affecter ses performances et même endommager l'appareil.

L'appareil peut être installé dans un rack 19''. Fixer l'appareil en utilisant les 4 trous pour vis sur la face avant. Assurez-vous d'utiliser des vis de la bonne dimension (vis non fournies). Essayez d'éviter les vibrations et les coups lors du transport.

En cas d'installation dans un 'flight case', assurer une bonne ventilation afin d'évacuer la chaleur produite par l'appareil.

Pour éviter la condensation à l'intérieur, laisser l'appareil s'adapter à la nouvelle température ambiante après le transport. La condensation peut altérer les performances de l'appareil.

NETTOYAGE:

Nettoyez l’appareil à l’aide d’un chiffon doux, légèrement humide. Evitez d’introduire de l’eau à l’intérieur de l’appareil. N’utilisez pas de produits volatiles tels que le benzène ou le thinner qui peuvent endommager l’appareil.

FRANCAIS

MODE D’EMPLOI

CONNEXIONS

Utilisez des câbles de bonne qualité afin d'éviter un son de mauvaise qualité. Pour plus d'informations sur les connexions, voyez le chapitre suivant.

Assurez-vous d'éteindre l’appareil avant d'effectuer les différentes connexions. Dans ce mode d'emploi, il est question d'entrée ligne ou “line inputs”. Il s'agit en fait d'un terme générique pour désigner des entrées avec un niveau compris entre 750mV et 2V. Ceci inclus les lecteurs de CD, tuners, vidéos,…

FONCTIONS (FACE AVANT)

1.Input Gain : contrôle le niveau d'entrée à concurrence de +/- 12dB.

2.Low Cut Switch : appuyez sur ce bouton pour sélectionner le filtre passe-haut de 40 Hz. Utilisez ce filtre pour protéger vos haut-parleurs et votre amplificateur des infrasons dangereux : il ne font que consommer de la puissance, mais ils n'ajoutent pas nécessairement plus de punch au son.

3.Crossover Point selection : sélectionne le point de coupure entre :

En mode stéréo : fréquences basses et aiguës ;

En mode mono : fréquences basses et médiums sur le canal 1 ;

fréquences médiums et aiguës sur le canal 2.

4. LED X10 : si la LED X10 est éteinte : vous pouvez faire varier la fréquence de coupure de 45 Hz à 960 Hz ;

si la LED X10 est allumée : vous pouvez faire varier la fréquence de coupure de 450 Hz à 9,6 kHz.

JB SYSTEMS®

7/30

EC102/XO210

JB SYSTEMS®

8/30

EC102/XO210

Loading...
+ 11 hidden pages