Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the
information below for definitions of the signal words.
DANGER
Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or
both.
!
Part No. 1145810
IMPORTANT
Indicates a hazardous situation that could result in damage to property if it is not avoided.
Gives useful tips, recommendations and information for efficient, trouble-free use.
5Electric Portable Patient Lift
1 GENERAL
1.2Limited Warranty
This warranty is extended only to the original purchaser/user of our products.
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.
Invacare warrants the products manufactured to be free from defects in materials and workmanship for a period of three years on the lift and one year
on the slings and electric components from the date of purchase. If within such warranty period any such product shall be proven to be defective, such
product shall be repaired or replaced, at Invacare’s option. This warranty does not include any labor or shipping charges incurred in replacement part
installation or repair of any such product. Invacare’s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and/or
replacement.
For warranty service, please contact the dealer from whom you purchased your Invacare product. In the event you do not receive satisfactory warranty
service, please write directly to Invacare at the address on the back cover, provide dealer’s name, address, date of purchase, indicate nature of the
defect.
Invacare Corporation will issue a serialized return authorization. The defective unit or parts MUST be returned for warranty inspection using the serial
number, when applicable as identification within 30 days of return authorization date. Do not return products to our factory without our prior consent.
C.O.D. shipments will be refused; please prepay shipping charges.
LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL
NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION,
MAINTENANCE OR STORAGE, PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT (INCLUDING, BUT NOT
LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS; PRODUCTS DAMAGED BY REASON
OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY
CIRCUMSTANCES BEYOND INVACARE’S CONTROL, AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE
WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE INSTRUCTIONS IN
THIS MANUAL.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, IF ANY,
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND
BEYOND THE DURATION OF THE EXPRESSED WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED
WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED
HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.
SOME STATES DO NOT ALLOW EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE, OR LIMITATION ON
HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU.
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE OR PROVINCIAL LAWS AND REQUIREMENTS.
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW
APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.
Electric Portable Patient Lift
6Part No. 1145810
2 SAFETY
2 Safety
The Safety section contains important information for the safe operation and use of this product.
2.1General Guidelines
WARNING
!
Check all parts for shipping damage before using. In case of damage, DO NOT use the equipment. Contact the Dealer for further instructions.
2.2Operating Information
General
DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and
any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional
equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical
personnel before attempting to use this equipment - otherwise, injury or damage may occur.
ACCESSORIES WARNING
Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by
other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products.
NOTICE
THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.
WARNING
The Invacare patient lift is NOT a transport device. It is intended to transfer an individual from one resting surface to another (such as a bed
to a wheelchair). Otherwise injury or damage may occur.
DO NOT attempt any transfer without approval of the patient’s physician, nurse or medical assistant. Thoroughly read the instructions in
this Owner’s Manual, observe a trained team of experts perform the lifting procedures and then perform the entire lift procedure several
times with proper supervision and a capable individual acting as a patient.
Use common sense in all lifts. Special care MUST BE taken with people with disabilities who cannot cooperate while being lifted.
Invacare slings and patient lift accessories are specifically designed to be used in conjunction with Invacare patient lifts. Slings and accessories
designed by other manufacturers are not to be utilized as a component of Invacare’s patient lift system.
If the patient lift is exposed to extreme temperature (above 100°F or below 32°F), high humidity and/or becomes wet, prior to use, ensure
handgrips do not twist on patient lift handle - otherwise damage or injury may occur.
Part No. 1145810
7Electric Portable Patient Lift
2 SAFETY
Between Boom
and hanger bar
Base of Lift
Pinch Points and Positioning
WARNING
Assembling the Lift
Operating the Lift
Pinch points exist between boom and hanger bar. Pinch
points also exist at base of lift. When positioning lift, be
aware of the position of the hanger bar and the patient.
Injury could occur.
WARNING
DO NOT overtighten mounting hardware. This will damage mounting brackets.
WARNING
Although Invacare recommends that two assistants be used for all lifting preparation, transferring from and transferring to procedures, our
equipment will permit proper operation by one assistant. The use of one assistant is based on the evaluation of the health care professional
for each individual case.
Make sure there is an audible click when mounting battery on the battery charger to confirm proper mounting. Otherwise, injury or
damage may occur.
DO NOT exceed maximum weight limitation of the patient lift. The weight limitation for the RPL450-2 is 450 lbs. The weight limitation for
the RPL600-2 is 600 lbs.
ALWAYS keep hands and fingers clear of moving parts to avoid injury.
Electric Portable Patient Lift
8Part No. 1145810
Using the Sling
WARNING
Lifting the Patient
Use an Invacare approved sling that is recommended by the individual’s doctor, nurse or medical assistant for the comfort and safety of the
individual being lifted.
DO NOT use any kind of plastic back incontinence pad or seating cushion between patient and sling material that may cause the patient to
slide out of the sling during transfer.
After each laundering (in accordance with instructions on the sling), inspect sling(s) for wear, tears, and loose stitching.
Bleached, torn, cut, frayed, or broken slings are unsafe and could result in injury. Discard immediately.
DO NOT alter slings.
Be sure to check the sling attachments each time the sling is removed and replaced, to ensure that it is properly attached before the patient
is removed from a stationary object (bed, chair or commode).
If the patient is in a wheelchair, secure the wheel locks in place to prevent the chair from moving forwards or backwards.
When connecting slings equipped with color coded straps to the patient lift, the shortest of the straps MUST be at the back of patient for
support. Using long section will leave little or no support for patient's back. The loops of the sling are color coded and can be used to place
patient in various positions. The colors make it easy to connect both sides of the sling equally. Make sure that there is sufficient head
support when lifting a patient.
WARNING
When using an adjustable base lift, the legs MUST be in the maximum Opened/Locked position before lifting the patient.
When elevated a few inches off the surface of the stationary object (wheelchair, commode, or bed) and before moving the patient, check
again to make sure that the sling is properly connected to the hooks of the hanger bar. If any attachments are not properly in place, lower
the patient back onto the stationary object (wheelchair, commode, or bed) and correct this problem.
Adjustments for safety and comfort should be made before moving the patient. Patient's arms should be inside of the straps.
Invacare slings are made specifically for use with Invacare Patient Lifts. For the safety of the patient, DO NOT intermix slings and patient
lifts of different manufacturers. Warranty will be voided.
During transfer, with patient suspended in a sling attached to the lift, DO NOT roll caster base over uneven surfaces that could cause the
patient lift to tip over. Use steering handle on the mast at all times to push or pull the patient lift.
Invacare does not recommend locking of the rear casters of the patient lift when lifting an individual. Doing so could cause the lift to tip and
endanger the patient and assistants. Invacare does recommend that the rear casters be left unlocked during lifting procedures to allow the
patient lift to stabilize itself when the patient is initially lifted from a chair, bed or any stationary object.
2 SAFETY
Part No. 1145810
9Electric Portable Patient Lift
2 SAFETY
Transferring the Patient
WARNING
Performing Maintenance
When elevated a few inches off the surface of the stationary object (wheelchair, commode, or bed) and before moving the patient, check
again to make sure that the sling is properly connected to the hooks of the hanger bar. If any attachments are not properly in place, lower
the patient back onto the stationary object (wheelchair, commode, or bed) and correct this problem.
Wheelchair wheel locks MUST be in a locked position before lowering the patient into the wheelchair for transport.
Before transferring, check that the wheelchair weight capacity can withstand the patient's weight.
Be sure to check the sling attachments each time the sling is removed and replaced, to ensure that it is properly attached before the patient
is removed from the bed or chair.
Mast pivot under the rubber boot must be tight to ensure safe use of the patient lift. Bolt must be checked at least every six months in
conjunction with periodic maintenance.
WARNING
Maintenance MUST be performed ONLY by qualified personnel.
After the first year of use, the hooks of the hanger bar and the mounting brackets of the boom should be inspected every three months to
determine the extent of wear. If these parts become worn, replacement must be made.
Casters and axle bolts require inspections every six months to check for tightness and wear.
After the first twelve months of operation, inspect the hanger bar and the eye of the boom (to which it attaches) for wear. If the metal is
worn, the parts MUST be replaced. Make this inspection every six months thereafter.
Regular maintenance of patient lifts and accessories is necessary to assure proper operation.
DO NOT overtighten mounting hardware. This will damage mounting brackets.
After the first six months of operation, inspect all pivot points and fasteners for wear. If the metal is worn, the parts MUST be replaced.
Make this inspection every six months.
Electric Portable Patient Lift
10Part No. 1145810
Electrical and Grounding
WARNING
Ꮨ
Disposal
2.3Radio Frequency Interference
GROUNDING INSTRUCTIONS
DO NOT, under any circumstances, cut or remove the round grounding prong from any plug used with or for Invacare products. Some
devices are equipped with three-prong (grounding) plugs for protection against possible shock hazards. Where a two-prong wall receptacle
is encountered, it is the personal responsibility and obligation of the customer to contact a qualified electrician and have the two-prong
receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. If you must use
an extension cord, use ONLY a three-wire extension cord having the same or higher electrical rating as the device being connected. In
addition, Invacare has placed RED/ORANGE warning tags on some equipment. DO NOT remove these tags.
Carefully read battery/battery charger information prior to installing, servicing or operating your patient lift.
WARNING
This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic
Equipment (WEEE) Directive 2002/96/CE.
DO NOT dispose of batteries in normal household waste. Device contains lead acid batteries. They MUST be taken to a proper disposal
site. Contact your local waste management company for information.
This product may contain substances that could be harmful to the environment if disposed of in places (landfills) that are not appropriate
according to legislation.
Please be environmentally responsible and recycle this product through your recycling facility at its end of life.
WARNING
Most electronic equipment is influenced by Radio Frequency Interference (RFI). CAUTION should be exercised with regard to the use of
portable communication equipment in the area around such equipment. If RFI causes erratic behavior, PUSH the Red Power Switch OFF
IMMEDIATELY. DO NOT turn the Power Switch ON while transmission is in progress.
2 SAFETY
Part No. 1145810
11Electric Portable Patient Lift
3 PRODUCT LABELING
BEFORE using the Patient
Lift, READ and
UNDERSTAND the Owner’s
Manual for proper
operation and safety
procedures.
WEIGHT LIMITATION 600 lbs.
The Invacare Patient lift is
NOT a transport device.
DO NOT roll casterbase over
uneven surfaces that may
cause the Patient Lift to tip
over.
DO NOT lock the casters of
the Patient Lift when lifting an
individual. Casters MUST be
left unlocked to allow Patient
Lift to stabilize during lifting
procedures.
USE ONLY Invacare slings
and lift accessories.
For maintenance and
replacement, use only
components designed for this
patient lift model. See the
product label for model
information.
Customer Service
1-800-333-6900
1070965 Rev B
3 Product Labeling
Electric Portable Patient Lift
12Part No. 1145810
4 TECHNICAL DATA
4 Technical Data
4.1Patient Lift
450 LB. ELECTRIC600 LB. ELECTRIC
LOW PROFILE
RPL450-2
Height at Sling Hook-up - MAX.:74 inches68 inches
Height at Sling Hook-up - MIN.:24 inches28 inches
Base Width OPEN:41.0 inches
Base Width CLOSED:26.5 inches
Base Height (Clearance):4.5 inches
Base Length:48.0 inches
Caster Size (FRONT/REAR):3.0/5.0 inches
Sling Options:3 Styles1 Style
Weight Capacity:450 lbs600 lbs
Weight IN Carton:136 lbs141 lbs
Weight OUT of Carton:109 lbs115 lbs
Battery:24V DC (RCHBL)
Charger Input:100-240V AC
Charger Output/Charging Time:29.5V DC Max 6 hrs
Accessories:Digital Scale
Audio Low Battery Alarm:Yes
Motor Safety Devices:Anti-Entrapment
Approx. Lifts per Charge
(Varies depending upon load and stroke):
*Slings made of a mesh material.
All dimensions are in inches except where noted.
R111
R114R115R116R117* R100PR100R101R102R121R140*R141*
R113*
450450450450450450450450450450450600600
DIVIDED LEGTOILETINGHEAVY
DUTY W/O
COMMODE
HEAVY
DUTY W/
COMMODE
4.3Reliant Scale RLS6
Weight Range:Up to 600 Lbs. (272.7 Kg)
Resolution:+/- 0.2 Lbs (.1 Kg)
Display:Liquid Crystal Digital
Automatic Power Down:Two (2) minutes
Size:5-3/4 L X 3-5/8 W X 4 H
Weight:.55 Lbs
Power:Nine (9) Volt Alkaline battery (included)
Battery Life:Approximately 1500 readings
Temperature Range:50° To 104°F (10° To 40°C)
Electric Portable Patient Lift
14Part No. 1145810
5 Assembly
DO NOT remove
plastic wrap at this time
5.1Introduction
WARNING
5.2Unpacking the Patient Lift
1.Unpack the components from the shipping carton.
Use only Invacare parts in the assembly of this patient lift. The base legs, mast, boom assembly and the hanger bar are manufactured to
specifications that assure correct alignment of all parts for safe functional operation.
5 ASSEMBLY
Part No. 1145810
DO NOT remove the plastic wrap that secures the
boom to the mast. The plastic wrap will be removed in
Assembling the Boom Actuator
on page 17.
15Electric Portable Patient Lift
5 ASSEMBLY
Step here to
LOCK.
Step here to UNLOCK.
Locking
Lever
Washers
Shoulder Bolt
Nut
U-shaped
Cutout
Mast
Mast
Base
5.3Assembling the Mast to the Base
WARNING
1.If locking-type casters are on the patient lift, lock them.
2.Remove the shoulder bolt, nut and washer, that secures the mast
in the U-shape cut-out of the base.
3.Position the mast in an upright position and place the mast into the
U-shaped cut-out of the base.
4.Insert shoulder bolt with washers through the base and mast.
5.Secure with nut.
The mast may be removed from the base for storage or
transporting. Each time the mast is removed and
returned to the base, the mast MUST be properly
secured to the base assembly.