BE CAREFUL! Never use sharp instruments, such as a pencil
M29343
or pen, to press touchscreen keys. To prevent damage to the
thermostat, always press keys with your fingertip.
This manual covers the following models
ENGLISH
This thermostat contains a Lithium battery which may contain Perchlorate material.
Perchlorate Material—special handling may apply,
See www.dtsc.ca.gov/hazardouswaste/perchlorate
TH8110U: For 1 Heat/1 Cool systems
TH8320U: For up to 3 Heat/2 Cool systems
TH8321U: For up to 3 Heat/2 Cool systems with dehumidification
(Pull thermostat from wallplate and turn over to find model number)
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions.
® U.S. Regi stered Tradem ark.
69-1894 EFS -01
US Patent No. 6595430, D509151 and other patents pending.
Your new thermostat is preprogrammed and ready to go.
See page 3 to check settings.
CAUTION: EQUIPMENT DAMAGE
HAZARD. To prevent possible
compressor damage, do not operate cooling system when outdoor
temperature is below 50˚F (10˚C).
1
69-1894 EFS -01
ENGLISH
Operating Manual
About your new thermostat
Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermostat. It has been designed to give you many years of reliable service and touchscreen climate control.
Features
ENGLISH
• 7-day program schedules maximize comfort and economy.
• Armchair programming: Just pull thermostat from the wall to set schedules.
• EnergyStar® compliant to greatly reduce your heating/cooling expenses.
• One-touch temp control overrides program schedule at any time.
• Precise comfort control keeps temperature within 1°F of the level you set.
• Change/check reminders let you know when to service or replace filters,
batteries and other critical components.
• Large touchscreen display with backlight is easy to read—even in the dark.
• Select models display and control summer humidity.
• Select models accommodate optional outdoor or indoor remote sensors.
69-1894 EFS -01
2
VisionPRO® TH8000 Series
About your new thermostat
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go. Just set the time and day.
Then check the settings below and change if needed:
1. Set clock ........................................................................................................See page 6
2. Select fan setting: Preset to Auto ..............................................................See page 7
3. Select system setting: Preset to Heat ......................................................See page 8
4. Program schedules: Preset to energy-saving levels
while you’re at work or asleep (assumes you
wake at 6 am, leave at 8 am, return at 6 pm
and go to bed at 10 pm) .......................................................................See pages 10-13
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time,
and manually adjust the temperature (see pages 12-14).
ENGLISH
3
69-1894 EFS -01
Operating Manual
SCHED HOLD CLOCK SCREEN MORE
MON
TUEWEDTHUFRISATSUN
AM
FAN
AUTO
SYSTEM
HEAT
Following
Schedule
Inside
Set To
OK TO PICK MULTIPLE DAYS
70
6:01
70
M29344
Quick reference to controls
Press day(s) to set program schedule (see page 11)
Press to select fan
operation (see page 7)
ENGLISH
Press to select system
type (see page 8)
Press to set program
schedule (see page 11)
Press to override
program schedule
(see pages 12-14)
69-1894 EFS -01
Press to set clock
(see page 6)
4
Press to adjust
temperature settings
(see pages 11-14)
Press for more options
(select models only)
Press to lock keypad for 30
seconds to clean screen
(see page 17)
VisionPRO® TH8000 Series
SCHEDHOLD CLOCKSCREEN MORE
WED
AM
FAN
AUTO
SYSTEM
HEAT
Following
Schedule
Inside
Set To
Recovery
70
6:01
70
M29345
Quick reference to status display
Current inside temperatureCurrent day of weekTemperature setting
Fan setting
System setting
Current time
Other display messages:
• Cool On: Cooling system is activated
• Heat On: Heating system is activated
• Aux Heat On: Auxiliary heating system is activated
ENGLISH
Program schedule on
(does not display
when off)
Adaptive Intelligent
Recovery in effect
(see page 15)
5
69-1894 EFS -01
Operating Manual
DONECANCEL
AM
6:02
M29347
SCHED HOLD CLOCK SCREEN MORE
AM
6:01
M29346
Clock setting
Press CLOCK
ENGLISH
Adjust time, then press DONE
69-1894 EFS -01
To set the current time display, press CLOCK,
then press s or t to adjust the time. Press
and hold s or t to advance the time more
quickly.
Press DONE to save & exit (or press CANCEL to
exit without changing the time).
Note: The real-time clock should never require
adjustment since it automatically updates for
daylight savings time, and stores all date/time
information.
Note: To change the current week day display, see
page 22.
6
SCHEDHOLDCLOCK SCREEN MORE
WED
AM
SYSTEM
HEAT
Following
Schedule
Inside
Set To
70
6:01
70
FAN
AUTO
M29348
Fan setting
PressFAN
Note: If a fan schedule is programmed,
“Auto” will run the fan schedule.
VisionPRO® TH8000 Series
Press FAN to select fan operation, then press
DONE.
• On: Fan is always on.
• Auto: Fan runs only when the heating or
cooling system is on.
• Circ: Fan runs randomly, about 35% of the
time, not counting any run time with the
heating or cooling system.
You can press FAN to override the fan settings
you’ve programmed for different time periods
(see page 11). If you select On or Circ, the
setting you select will remain active until you
press FAN again to select Auto (see page 27
for more information).
7
69-1894 EFS -01
ENGLISH
Operating Manual
SCHED HOLD CLOCKSCREEN MORE
WED
AM
Following
Schedule
Inside
Set To
70
6:01
70
FAN
AUTO
SYSTEM
HEAT
M29349
System setting
ENGLISH
69-1894 EFS -01
Press the SYSTEM button to select, then press
DONE.
• Heat: Thermostat controls only the
heating system.
• Cool: Thermostat controls only the
cooling system.
• Off: Heating and cooling systems are off.
• Auto: Thermostat automatically selects
heating or cooling depending on the
indoor temperature.**
• Em Heat (only for heat pumps with
auxiliary heat): Thermostat controls
Emergency and Auxiliary Heat.
Compressor is locked out.**
** Select models only
8
VisionPRO® TH8000 Series
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four
time periods each day, with different settings for weekdays and weekends.
WAKE
6:00 am
°
70
LEAVE
8:00 am
°
62
RETURN
6:00 pm
°
70
SLEEP
10:00 pm
°
62
Set to the time you awaken and the temperature you want
during the morning, until you leave for the day.
Set to the time you leave home and the temperature you
want while you are away (usually an energy-saving level).
Set to the time you return home and the temperature you
want during the evening, until bedtime.
Set to the time you go to bed and the temperature you want
overnight (usually an energy-saving level).
9
69-1894 EFS -01
ENGLISH
Operating Manual
EnergyStar® settings for maximum cost savings
This thermostat is pre-set to use EnergyStar® program settings. We recommend these settings, since
they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times
5. Press other time periods (LEAVE, RETURN,
SLEEP) to set time and temperatures for
each.
6. Press DONE to save & exit (or press CANCEL
to exit without saving changes).
Note: You can press CANCEL PERIOD to eliminate any
unwanted time period.
Note: Press FAN to customize fan settings for any
time period (see page 7).
11
69-1894 EFS -01
ENGLISH
Operating Manual
Heat On
SCHEDHOLDCLOCK SCREEN MORE
CANCEL
WED
Inside
Hold Temperature
Until
Set To
73
AM
8:00
70
FAN
AUTO
SYSTEM
HEAT
M29353
Program schedule override (temporary)
ENGLISH
Press to set timer
69-1894 EFS -01
Adjust temperature
Press CANCEL (or SCHED) to
resume program schedule
Press s or t to immediately adjust the temperature. This will temporarily override the
temperature setting for the current time period.
The new temperature will be maintained only
until the time you set. When the timer expires,
the program schedule will resume and set the
temperature to the level you’ve programmed
for the current time period.
To cancel the temporary setting at any time,
press CANCEL (or SCHED). The program schedule
will resume.
12
Heat On
SCHED HOLD CLOCKSCREEN MORE
CANCEL
WED
AM
Inside
Set To
Permanent
Hold
73
8:00
70
FAN
AUTO
SYSTEM
HEAT
M29354
Program schedule override (permanent)
VisionPRO® TH8000 Series
Press HOLD Adjust temperature
Press CANCEL (or SCHED) to
resume program schedule
Press HOLD to permanently adjust the
temperature. This will turn off the program
schedule.
Whatever temperature you set will be
maintained 24 hours a day until you manually
change it or press CANCEL (or SCHED) to cancel
“Hold” and resume the program schedule.
13
69-1894 EFS -01
ENGLISH
Operating Manual
SCHEDHOLDCLOCK SCREEN MORE
CANCEL
AM
Inside
Hold Temperature
Until
Set To
55
6:00
70
FAN
AUTO
SYSTEM
HEAT
M29355
SCHED HOLD CLOCKSCREEN MORE
CANCEL
DAYS
Hold Temperature
Until
14
SYSTEM
HEAT
M29356
Vacation hold
1. Set temperature
ENGLISH
2. Press to set time for
schedule to resume
3. Press HOLD twice
4. Press to select number of days
69-1894 EFS -01
This feature can suspend the program sched-
ule for extended periods of time.
Press s or t to set the temperature you want,
then press s or t to set the time of day you
want the schedule to resume when you return.
Press HOLD twice, then press s or t to select
the number of days.
Whatever temperature you set will be maintained 24 hours a day for the number of days
you select. After this number of days have
elapsed, the previously programmed schedule
will resume at the time you set.
If you return earlier than expected, press
CANCEL (or SCHED) to cancel “Hold” and resume
the program schedule.
14
VisionPRO® TH8000 Series
Special features
Auto Changeover: When set to Auto, the thermostat automatically selects heating or
cooling depending on the indoor temperature.
Adaptive Intelligent Recovery: This feature allows the thermostat to “learn” how
long the furnace and air conditioner take to reach programmed temperature settings,
so the temperature is reached at the time you set. For example: Set the Wake time to
6 am, and the temperature to 70°. The heat will come on before 6 am, so the tempera-
ture is 70° by the time you wake at 6. The message “Recovery” is displayed when the
system is activated before a scheduled time period.
Compressor Protection: This feature forces the compressor to wait a few minutes
before restarting, to prevent equipment damage. During the wait time, the message
“Wait” is displayed on screen.
ENGLISH
15
69-1894 EFS -01
Operating Manual
M29357
SCHED HOLD CLOCK SCREEN MORE
WED
PM
Following
Schedule
Inside
Set To
SCREEN LOCKED
70
6:00
70
FAN
AUTO
SYSTEM
HEAT
Screen lock
ENGLISH
See advanced function
0670 (page 25) for
screen lock options
69-1894 EFS -01
To prevent tampering, the screen can be partially or fully locked.
When partially locked, the screen displays
SCREEN LOCKED for several seconds if a locked
key is pressed. To unlock the screen, press any
unlocked key while SCREEN LOCKED appears on
the screen.
When the screen is fully locked, no keys
function. To lock or unlock the screen, see
advanced function 0670 on page 25.
16
SCHEDHOLDCLOCK SCREEN MORE
PM
6:00
M29358
OK TO
CLEAN
SCREEN
30
M29359
Screen cleaning
VisionPRO® TH8000 Series
Press SCREEN
Screen lock timer (30 seconds)
Press SCREEN to lock the screen for cleaning.
The screen will remain locked for 30 seconds
so you can clean the screen without changing
any settings.
After 30 seconds, press DONE to resume normal
operation, or press SCREEN again if you require
more time for cleaning.
Note: Do not spray any liquid directly on the
thermostat. Spray liquids onto a cloth, then use
the damp cloth to clean the screen. Use water or
household glass cleaner. Avoid abrasive cleansers.
17
69-1894 EFS -01
ENGLISH
Operating Manual
SCHED HOLD CLOCK SCREEN MORE
WED
PM
FAN
AUTO
SYSTEM
HEAT
Following
Schedule
Inside
Set To
Humidity
70
6:00
70
43
M29360
About your new thermostat
Humidity level display (select models)
Select models can display the current indoor
humidity level.
(If an optional outdoor sensor is installed,
ENGLISH
the outdoor temperature is shown instead of
the humidity level. Press MORE to display the
humidity level.)
Indoor humidity level
69-1894 EFS -01
18
About your new thermostat
SCHEDHOLDCLOCK SCREEN MORE
PM
6:00
M29361
DONECANCEL
DEHUMIDIFIER
Inside
Humidity
52
45
M29362
Dehumidification control (select models)
VisionPRO® TH8000 Series
Press MORE until humidity is displayed
Press to set desired humidity
Press to save & exit
Select models allow you to decrease summer
humidity.
The thermostat monitors humidity. When
humidity increases, the thermostat runs the air
conditioner longer to reduce humidity (up to
3°F below your cooling temperature setting).
Press MORE until the humidity screen is displayed, then press s or t to set the desired
humidity level.
Press DONE to save and exit, or press CANCEL to
exit without saving changes.
19
69-1894 EFS -01
ENGLISH
Operating Manual
M29364
M29363
About your new thermostat
Battery replacement
Grasp thermostat and pull to remove
fom wallplate
ENGLISH
Insert 3 fresh AAA alkaline batteries
69-1894 EFS -01
Batteries are optional (to provide backup
power) if your thermostat was wired to run on
AC power when installed.
Install fresh batteries immediately when the
LOBATT warning begins flashing. The warning flashes about 30 days before batteries are
depleted.
Even if the warning does not appear, you
should replace batteries once a year, or before
leaving home for more than a month.
20
About your new thermostat
DONECANCEL
AM
6:01
SYSTEM
HEAT
DONE
0120
20
M29366
SCHED HOLD
TUE
AM
Inside
6:01
70
FAN
AUTO
SYSTEM
HEAT
M29365
Advanced functions
VisionPRO® TH8000 Series
1. Press SYSTEM.
2. Press and hold
blank center key
until the display
changes.
3. Change settings as
required (see pages
22-25).
4. Press DONE to exit &
save changes.
21
Function Setting
Press s/t to
select function
Press s/t to
change setting
69-1894 EFS -01
ENGLISH
Operating Manual
About your new thermostat
Advanced functions
Year setting (first two digits)
Function
0120
Options:20 = Year 20xx
ENGLISH
Press s/t to change the first two digits of the year:
21 = Ye ar 21xx
Year setting (second two digits)
Function
0130
Options:01 - 99 (i.e., 2001 - 2099)
Press s/t to change the last two digits of the year:
Month setting
Function
0140
Options:1 - 12 (i.e., January - December)
Press s/t to change the current month:
Date setting
Function
0150
Options:1 - 31
Press s/t to change the current date:
69-1894 EFS -01
22
VisionPRO® TH8000 Series
Advanced functions
Program schedule on/off
Function
0160
Options:0 Program schedule is off. Thermostat is non-programmable.
Temperature format (°F/°C)
Function
0320
Options:0 Fahrenheit
Daylight savings time on/off
Function
0330
Options:0 Off: No adjustment for daylight savings time
Press s/t to turn the program schedule on or off:
4 Program schedule is on (7-day programmable).
Press s/t to set the temperature display format:
1 Celsius
The thermostat is pre-programmed to automatically adjust to daylight savings time.
Press s/t to select an option:
1 On: Auto-change to daylight savings time (through 2006, and for areas that
do not use the new 2007 DST calendar)
2 On: Auto-change to daylight savings time (2007 and beyond, for areas that
use the new 2007 DST calendar)
ENGLISH
23
69-1894 EFS -01
Operating Manual
About your new thermostat
Advanced functions
Furnace filter change reminder
Function
0500
Options:0 Off (no reminder to change furnace filter)
ENGLISH
This feature displays an alert to remind you to change the furnace filter.
Press s/t to set the desired reminder interval:
1 Reminder after 10-day run time (about 1 month)
2 Reminder after 30-day run time (about 3 months)
3 Reminder after 60-day run time (about 6 months)
4 Reminder after 90-day run time (about 9 months)
5 Reminder after 120-day run time (about 1 year)
6 Reminder after 365-day run time (about 3 years)
Humidifier pad change reminder
Function
0510
Options:0 Off (no reminder to change humidifier pad)
This feature displays an alert to remind you to change the humidifier pad.
Press s/t to set the desired interval:
1 Reminder after 3 months
2 Reminder after 6 months
3 Reminder after 1 year
Note: Press RESET
to cancel the aler t
Note: Press RESET
to cancel the aler t
69-1894 EFS -01
24
Advanced functions
UV lamp change reminder
Function
0520
Options:0 Off (no reminder to change UV lamp)
Program schedule periods
Function
0540
Options:2 Two program periods (Wake, Sleep)
Clock format
Function
0640
Options:12 12-hour clock (i.e., “3:30 pm”)
Screen lock
Function
0670
Options:0 Screen is unlocked (fully functional)
This feature displays an alert to remind you to change the ultraviolet lamp.
Press s/t to set the desired interval:
1 Reminder after 1 year
Press s/t to set the number of program periods:
4 Four program periods (Wake, Leave, Return, Sleep)
Press s/t to set the clock display format:
24 24-hour clock (i.e., “15:30”)
Press s/t to choose a screen lock setting (see page 16):
1 All functions locked except temperature controls and CANCEL key
2 Screen is fully locked
25
VisionPRO® TH8000 Series
Note: Press RESET
to cancel the aler t
69-1894 EFS -01
ENGLISH
Operating Manual
In case of difficulty
If you have difficulty with your thermostat, please try the following suggestions.
Most problems can be corrected quickly and easily.
Display is blank • Check circuit breaker and reset if necessary.
ENGLISH
• Make sure power switch at heating & cooling system is on.
• Make sure furnace door is closed securely.
• If thermostat is battery powered, make sure fresh AAA alkaline
batteries are correctly installed (see page 20).
No response to
key presses (or
temperature will
not change)
Backlight is dim• If thermostat is battery powered, make sure fresh AAA alkaline
69-1894 EFS -01
• Check to make sure the thermostat is not locked (see page 25).
Make sure heating and cooling temperatures are set to acceptable ranges:
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
batteries are correctly installed (see page 20).
• If thermostat is AC powered, a dim display is normal. The backlight
remains on at a low level, and brightens when a key is pressed.
26
In case of difficulty
VisionPRO® TH8000 Series
Heating or
cooling system
does not respond
Display shows
Fan Auto and On
or Auto and Circ
at the same time
• Press SYSTEM to set system to Heat. Make sure the temperature is set
higher than the Inside temperature.
• Press SYSTEM to set system to Cool. Make sure the temperature is set
lower than the Inside temperature.
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is on.
• Make sure furnace door is closed securely.
• If “Wait” is displayed, the compressor protection timer is on. Wait
5 minutes for the system to restart safely, without damaging the
compressor (see page 15).
• This is normal operation. Auto indicates the thermostat is following the
programmed fan setting. If Auto and On is shown, the fan is scheduled
for “On” during this period (see page 7).
27
69-1894 EFS -01
ENGLISH
Loading...
+ 67 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.