This quick start guide is intended for users of the models below:
It includes instructions on how to use the Product. The software embodied in the Product is governed by the user license
agreement covering that Product.
About this Manual
This Manual is subject to domestic and international copyright protection. Hangzhou Hikvision Digital Technology Co., Ltd.
(“Hikvision”) reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, partially or
wholly, by any means, without the prior written permission of Hikvision.
Trademarks
and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of
applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their
respective owners. No right of license is given to use such trademarks without express permission.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, REGARDING THIS MANUAL. HIKVISION
DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR
RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE WHOLLY AT YOUR
OWN RISK AND RESPONSIBILITY.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. OUR COMPANY SHALL NOT
TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF
REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER
TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. OUR COMPANY SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED
WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Support
Should you have any questions, please do not hesitate to contact your local dealer.
i
Page 3
Warnings Follow
these safeguards to
prevent serious
injury or death.
Cautions Follow these
precautions to prevent
potential injury or
material damage.
Access Control Terminal·Quick Start Guide
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his
own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the
applicable harmonized European standards listed under the Low Voltage Directive 2006/95/EC, the EMC Directive
2004/108/EC, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal
waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentation for specific battery information. The battery is
marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For
proper recycling, return the battery to your supplier or to a designated collection point. For more information see:
www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss.
The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings
All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and
other related regulations in your local region.
Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required
value.
Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard.
Please make sure that the power has been disconnected before you wire, install or dismantle the device.
When the product is installed on wall or ceiling, the device shall be firmly fixed.
If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact
the service center.
ii
Page 4
Access Control Terminal·Quick Start Guide
If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the
device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
Cautions
Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the
equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold,
dusty or damp locations, and do not expose it to high electromagnetic radiation.
The device cover for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can
cause fire danger).
Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction
however), and affecting the endurance of sensor at the same time.
Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic
sweat of the fingers may erode the surface coating of the device cover.
Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents.
Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the
factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to
additional costs.
Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only.
Dispose of used batteries according to the instructions provided by the battery manufacturer.
1.2 Main Features ........................................................................................................................................................... 3
1.2.1 Main Features of DS-K1T105 Series Model ........................................................................................................ 3
1.2.2 Main Features of DS-K1T200 Series Model ........................................................................................................ 4
2.1 Appearance of DS-K1T105 Series Model ................................................................................................................... 5
2.2 Appearance of DS-K1T200Series Model .................................................................................................................... 5
2.2.1 Description of Components ................................................................................................................................ 5
2.3 Appearance of Keys ................................................................................................................................................... 6
2.3.1 Description of Items ........................................................................................................................................... 6
4.2 The Wiring of External Card Reader ........................................................................................................................ 11
4.2.1 The Wiring of External RS-485 Card Reader ..................................................................................................... 11
4.2.2 The Wiring of External Wiegand Card Reader .................................................................................................. 11
4.3 The Wiring of Electric Lock and Door Contact ......................................................................................................... 12
4.3.1 The Wiring of Electric Lock ............................................................................................................................... 12
4.3.2 The Wiring of Door Contact .............................................................................................................................. 12
4.4 The Wiring of Exit Button ........................................................................................................................................ 13
4.5 The Wiring of Alarm Input ....................................................................................................................................... 13
4.6 The Wiring of External Alarm Device ....................................................................................................................... 14
4.7.1 The Wiring of Wiegand ..................................................................................................................................... 14
4.7.2 The Wiring of RS-485 Output ............................................................................................................................ 15
5 Activating the Access Control Terminal ...................................................................................................................16
5.1 Activating via SADP Software .................................................................................................................................. 16
5.2 Activating via Client Software ................................................................................................................................. 17
6.1 User Management .................................................................................................................................................. 20
6.1.2 Adding User ...................................................................................................................................................... 20
6.1.2 Managing User .................................................................................................................................................. 21
6.2 Communication Settings ......................................................................................................................................... 23
6.2.2 Serial Port Settings ............................................................................................................................................ 24
6.3 System Settings ....................................................................................................................................................... 27
6.3.1 Setting System .................................................................................................................................................. 27
6.3.2 Managing Data .................................................................................................................................................. 28
6.3.4 Door Settings .................................................................................................................................................... 29
6.3.5 Setting the Camera ........................................................................................................................................... 29
6.4 Time Settings ........................................................................................................................................................... 30
6.8 System Information ................................................................................................................................................. 32
Appendix: Tips for Scanning Fingerprint ....................................................................................................................34
2
Page 7
Figure 1-1 DS-K1T105 Series Standalone Access Control Terminal Front Panel
DS-K1T105 is a series of standalone access control terminal with picture capturing function. DS-K1T105 is designed with a
2.8-inch LCD display screen, and HD camera (2 MP optional). It supports two network communication methods (TCP/IP, and
Wi-Fi), and supports offline operation.
Figure 1-2 DS-K1T200 Series IP-Based Fingerprint Access Control Terminal Front Panel
DS-K1T200 is a series optical IP-based fingerprint access control terminal with multiple advanced technologies including fingerprint
recognition, face detection, Wi-Fi, smart card recognition, LCD display screen, and picture capturing technology. It is designed with a 2.8-inch
LCD display screen, and HD camera (2 MP optional). It is equipped with optical fingerprint recognition module (supporting 1:1
mode and 1:N mode), and supports offline operation.
Access Control Terminal·Quick Start Guide
1 Overview
1.1 Introduction
1.2 Main Features
1.2.1 Main Features of DS-K1T105 Series Model
Doorbell ringtone settings function
Touch mode and blue light display technique for keypad
Stand-alone settings for the terminal
2.8-inch LCD display screen
Transmission modes of wired network (TCP/TP) and Wi-Fi
Face detection and picture capturing function implemented by built-in camera (2 MP optional, only supports DS-K1T105E/M
-C)
Supports multiple door opening modes (card, card + password, exit button, etc.)
Supports RS-485 communication for connecting to external card reader
Supports working as a card reader, and supports Wiegand interface and RS-485 interface for accessing the controller
Max. 100,000 valid card No., and Max. 300,000 access control events records storage
Supports EM card reading (DS-K1T105E/E-C)
Supports Mifare card reading, including card No. reading, & writing function (DS-K1T105M/M-C)
Tampering detection, unlocking overtime alarm, invalid card swiping over times alarm, and duress card alarm
Accurate data and time display provided by built-in electronic clock and watchdog program to ensure the basic function of the
terminal
3
Page 8
Access Control Terminal·Quick Start Guide
Data can be permanently saved after power-off
1.2.2 Main Features of DS-K1T200 Series Model
Doorbell ringtone settings function
Touch mode and blue light display technique for keypad
Stand-alone settings for the terminal
2.8-inch LCD display screen
Transmission modes of wired network (TCP/TP) and Wi-Fi
Face detection and picture capturing function implemented by built-in camera (2 MP optional, only supports
DS-K1T200EF/MF-C)
Supports RS-485 communication for connecting external card reader
Supports working as a card reader, and supports Wiegand interface and RS-485 interface for accessing the controller
Max. 100,000 card No., Max. 300,000 access control events records, and Max. 9500 fingerprints storage
Adopts the optical fingerprint module, supporting 1:N mode (fingerprint, card + fingerprint) and 1:1 mode (card + fingerprint)
Supports multiple authentication modes (card, fingerprint, card + fingerprint, card + password, fingerprint + password, card +
fingerprint + password, and so on.)
Supports EM card reading (DS-K1T200EF/EF-C)
Supports Mifare card reading, including card No. reading, and sector reading & writing (DS-K1T200MF/MF-C)
Tampering detection, unlocking overtime alarm, invalid card swiping over times alarm, duress card alarm, and so on
Accurate data and time display provided by built-in electronic clock and watchdog program to ensure the basic function of the
terminal
Data can be permanently saved after power-off
4
Page 9
No.
Description
1
2.8-Inch LCD Display Screen
2
HD Camera with 2 MP (only DS-K1T105E/M/ -C
support)
3
Keypad
4
USB 2.0 Interface
5
Power Interface
6
PSAM Card Slot
7
External Wiring Terminals
8
Serial Port
9
Ethernet Port
10
Tampering Prevention Switch
No.
Description
1
2.8-Inch LCD Display Screen
Access Control Terminal·Quick Start Guide
2 Appearance
2.1 Appearance of DS-K1T105 Series Model
Please refer to the following content for detailed information of the DS-K1T105 series model.
Figure 2-1 Appearance of DS-K1T105 Series Model
Table 2-1 Description of DS-K1T105 Series Model
2.2 Appearance of DS-K1T200Series Model
Please refer to the following content for detailed information of DS-K1T200 series model
Figure 2-2 Appearance of DS-K1T200 IP-Based Fingerprint Access Control Terminal
2.2.1 Description of Components
Table 2-2 DS-K1T200 IP-Based Fingerprint Access Control Terminal Components
5
Page 10
No.
Description
2
HD Camera with 2 MP (only DS-K1T200EF/MF
-C support)
3
Keypad
4
Optical Fingerprint Reading Module
5
USB 2.0 Interface
6
Power Interface
7
PSAM Card Slot
8
External Wiring Terminals
9
Serial Port
10
Ethernet Port
11
Tampering Prevention Switch
No.
Description
1
Numeric Keys: Enter number in the textbox.
Direction Keys: Select icons in the menu.
2
Editing Key: Click the key to enter/exit the editing status.
3
Exiting Key: Click the key to exit the menu.
4
Confirming Key: Click the key to confirm operations.
Long-click the key to enter the login interface.
5
Deleting Key: Click the key to delete contents in the textbox.
6
Status Indicator:
Indicator for
power, ring, and
connection status
POWER
Power Status
Solid Blue: Normal Power.
Off:Power Exception.
Doorbell Ring
LINK
Normal Card/
Illegal Card
Normal Card: Solid Blue
Illegal Card: Solid Red
Connection
Status
Off: Network or Wi-Fi Disconnected.
Solid Blue: Network or Wi-Fi
connected, but client unarmed.
Flicker Blue: Network or Wi-Fi
connected, but client armed.
Flicker blue in the card reader mode.
Access Control Terminal·Quick Start Guide
2.3 Appearance of Keys
2.3.1 Description of Items
Figure 2-3 Appearance of Keys
Table 2-3 Description of Keys
6
Page 11
Access Control Terminal·Quick Start Guide
In the Event Card Interact interface in the iVMS-4200 Client Software, choose the alarm output of Event Bell. You can connect a bell
at the alarm output terminal. For details about configuring the Event Bell alarm output, see the User Manual of iVMS- 4200 Client Software.
7
Page 12
Access Control Terminal·Quick Start Guide
3 Terminal Connection
3.1 Terminal Description
Figure 3-1 Terminal Diagram of Access Control Terminal
Set the dial-up of the external card reader as 2 when connected to the access control terminal.
The external power supply and the access control terminal should use the same GND cable.
11
Page 16
Access Control Terminal·Quick Start Guide
4.3 The Wiring of Electric Lock and Door Contact
4.3.1 The Wiring of Electric Lock
Figure 4-4 The Installation of Electric Dropbolt, Magnetic Lock, and Electric Strike
Signal input interface of the door status (DOOR_NC, DOOR_COM, DOOR_NO) is used to recognize whether the door is locked. If the
NC interface is connected for opening door, the NO interface can only be connected for locking door.
4.3.2 The Wiring of Door Contact
Figure 4-5 The Installation of Door Contact
12
Page 17
Access Control Terminal·Quick Start Guide
4.4 The Wiring of Exit Button
Figure 4-6 The Installation of Exit Button
4.5 The Wiring of Alarm Input
Figure 4-7 Alarm Input Connection
13
Page 18
Access Control Terminal·Quick Start Guide
4.6 The Wiring of External Alarm Device
Figure 4-8 The Installation Diagram of External Alarm Device
4.7 Card Reader Connection
The access control terminal can be switched into the card reader mode. It can access to the access control as a card reader, and
supports Wiegand communication port and RS-485 communication port.
When the access control terminal works as a card reader, it only supports being connected to the controller, but does not support
alarm input or output, or the connection of external devices.
4.7.1 The Wiring of Wiegand
Figure 4-9 Wiegand Connection Diagram
When the access control terminal works as a card reader, you must the WG_ERR, BUZZER and WG_OK interfaces if you want
to control the LED and buzzer of the Wiegand card reader.
Set the working mode of the terminal as card reader, which can be configured in System Parameter –> Mode Switch, if the
terminal is required to work as a card reader. The card reader mode support to communicate by Wiegand or RS-485.
The distance of Wiegand communication should be no longer than 80 m.
The external power supply and the access control terminal should use the same GND cable.
14
Page 19
Access Control Terminal·Quick Start Guide
4.7.2 The Wiring of RS-485 Output
Figure 4-10 RS-485 Connection Diagram
Set the working mode of the terminal as card reader, which can be configured in System Parameter –> Mode Switch, if the
terminal requires working as a card reader.
When the access control terminal works as a RS-485 card reader, the default RS-485 address is 1. RS-485 address can also be
configured in System Parameter -> Serial Port Settings.
The external power supply and the access control terminal should use the same GND cable.
15
Page 20
Access Control Terminal·Quick Start Guide
5 Activating the Access Control Terminal
Purpose:
You are required to activate the terminal first before using it.
Activation via SADP, and Activation via client software are supported.
The default values of the control terminal are as follows.
The default IP address: 192.0.0.64.
The default port No.: 8000.
The default user name: admin.
5.1 Activating via SADP Software
SADP software is used for detecting the online device, activating the device, and resetting the password.
Get the SADP software from the supplied disk or the official website, and install the SADP according to the prompts. Follow the
steps to activate the control panel.
Steps:
1. Run the SADP software to search the online devices.
2. Check the device status from the device list, and select an inactive device.
Figure 5-1 SADP Interface
3. Create a password and input the password in the password field, and confirm the password.
STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing
(using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in
order to increase the security of your product. And we recommend you reset your password regularly, especially in the
high security system, resetting the password monthly or weekly can better protect your product.
4. Click OK to save the password.
You can check whether the activation is completed on the pop-up window.
If activation failed, please make sure that the password meets the requirement and then try again.
5. Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking
the checkbox of Enable DHCP.
16
Page 21
Access Control Terminal·Quick Start Guide
Figure 5-2 Modify Network Parameters Interface
6. Input the password and click the Save button to activate your IP address modification.
5.2 Activating via Client Software
The client software is versatile video management software for multiple kinds of devices.
Get the client software from the supplied disk or the official website, and install the software according to the prompts. Follow the
steps to activate the control panel.
Steps:
1. Run the client software and the control panel of the software pops up, as shown in the figure below.
2. Click the icon on the upper-left side of the page, select AccessControl to enter the control panel.
Figure 5-3 Control Panel Interface
3. Click the Controller Management icon to enter the Controller Management interface, as shown in the figure below.
17
Page 22
Access Control Terminal·Quick Start Guide
Figure 5-4 Device List
4. Check the device status from the device list, and select an inactive device.
5. Click the Activate button to pop up the Activation interface.
Figure 5-5 List Selecting Interface
6. Create a password and input the password in the password field, and confirm the password.
STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing
(using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters)
in order to increase the security of your product. And we recommend you reset your password regularly, especially in
the high security system, resetting the password monthly or weekly can better protect your product.
7. Click OK button to start activation.
8. Click the button to pop up the Network Parameter Modification interface.
9. Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking
the checkbox of Enable DHCP.
10. Input the password to activate your IP address modification.
18
Page 23
Access Control Terminal·Quick Start Guide
6 Basic Operation
Before You Start:
You should activate the device before the first login. Otherwise, after powered on, the system will switch into activate
notifying interface. For detailed information about activation, see Chapter5 Activating the Access Control Terminal.
Figure 6-1 Activation Notifying Interface
You should enter the default password for the first login.
Enter System Settings -> System Parameter –> Login Password to reset the login password.
The default password is 12345.
The working flow is as follows:
Steps:
1. Power on the device to enter the initial interface.
Figure 6-2 Initial Interface
2. Long-tap the # key to enter the password authentication interface.
19
Page 24
Access Control Terminal·Quick Start Guide
Figure 6-3 Password Authentication Interface
3. Enter the default configuration password. Tap the # key to confirm the settings. If the configuration password authentication failed, the system will return to the initial
interface, and if the configuration password is successfully authenticated, the system will enter the menu operation interface
Figure 6-4 Menu Operation Interface
On the menu operation interface, you can manage users, set communication parameters, set system parameters, and so on.
6.1 User Management
Purpose:
On the user management interface, you can add and manage users.
Steps:
1. Move the cursor to User (user management) by using the direction keys.
2. Tap the # key to enter the User interface.
Figure 6-5 User Management Interface
6.1.2 Adding User
Purpose:
In the Adding User menu, you can add users, register card, and record fingerprints optionally for the corresponding person.
Steps:
1. Move the cursor to Add (add user) by using the direction keys.
2. Tap the # key to enter the Add interface.
20
Page 25
Access Control Terminal·Quick Start Guide
Figure 6-6 Card Registration Interface
3. Register the card.
Register the card by swiping the card.
1) Place the card on the induction area.
2) The system displays the card No. in the textbox automatically with a beep sound if the card No. has been recognized. .
Register the card by entering the card number into the or enter the Card No. textbox.
1) Tap the key to enter the editing mode.
2) Enter the card number into the textbox.
3) Tap the key to exit the editing mode.
4. After registering the card, a dialog box about whether to register the fingerprint pops up.
Figure 6-7 Card Registration Pop-up Window
1) Move the cursor to the OK button, and tap the # key to enter the fingerprint registration interface.
Figure 6-8 Fingerprint Registration Interface
2) Place the finger on the fingerprint scanner, rise and rest your finger by following the corresponding voice prompts.
The fingerprint registration function only supports device with fingerprint module.
The same fingerprint cannot be repeatedly registered.
For the optical access control terminal, you should place your finger twice to register the fingerprint. For details about
scanning fingerprints, refer to Appendix.
6.1.2 Managing User
2. Move the cursor to the Manage (edit user) by using the direction keys.
21
Page 26
Access Control Terminal·Quick Start Guide
3. Tap the # key to enter the Management interface.
Searching User
Steps:
1. Move the cursor to a user by using the direction keys.
2. Tap the # key to pop up an interface for selecting corresponding operations.
Figure 6-9 Managing User Interface
3. Move the cursor to Search User by using the direction keys.
4. Tap the # key to enter the searching interface.
Figure 6-10 Searching Interface
5. Enter the card number to Please enter card No. textbox.
6. Tap the # key to view the basic information about the card holder.
Editing User
Steps:
1. Move the cursor to a user by using the direction keys.
2. Tap the # key to popup an interface for selecting corresponding operations. (Figure 6-9)
3. Move the cursor to Editing User.
4. Tap the # key to enter the editing interface.
Figure 6-11 Editing Interface
5. Edit the user information.
22
Page 27
Access Control Terminal·Quick Start Guide
Adding the Fingerprint
Move the cursor to Add to enter the fingerprint registration interface. See details in step 4 of adding user.
DS-K1T105 series model does not support this function.
Changing the Password
1) Move the cursor to Change PWD to enter the password changing interface.
2) Enter a new password.
3) Confirm the new password.
Figure 6-12 Password Changing Interface
Changing the valid date.
You can set the start/end time of the user’s permission.
Tap the key to enter/exit the editing mode.
Enabling first card
Tap the # key to enable first card.
After enabling first card, the door remains open during the pre-defined valid duration.
6. Move the cursor to the OK button, and tap the # key to confirm the settings.
Deleting the User
Steps:
1. Move the cursor to a user by using direction keys.
2. Tap the # key to pop up an interface for selecting corresponding operations. (Figure 6-9)
3. Move the cursor to Delete User, and tap the # key to enter the deleting interface.
4. Move the cursor to Delete User, Delete PWD only or Delete FP only,.
Delete User: Delete the user and the overall information.
Delete PWD only: Only delete the password set by the user.
Delete FP only: Only delete the fingerprint information of the user.
DS-K1T105 series model does not support this function.
5. Tap the # key to finish the deleting operation.
You can tap the * key to return to the main menu.
6.2 Communication Settings
Purpose:
On the communication settings interface, you can set network parameters, the serial port, Wiegand parameters, and Wi-Fi.
Steps:
1. Move the cursor to Comm (communication settings) by using direction keys.
2. Tap the # key to enter the communication settings interface.
23
Page 28
Access Control Terminal·Quick Start Guide
Figure 6-13 Communication Settings Interface
Network Settings: It refers to network parameters of the device, including IP address, subnet mask, and gateway address.
Serial Port Settings: When the access control terminal works as a RS-485 card reader, serial port parameters include working
mode, Baud Rate, and RS-485 address.
Wiegand Settings: When the access control terminal works as a Wiegand card reader, Wiegand parameters involve the Wiegand
direction, and the Wiegand mode.
Wi-Fi: You can enable the Wi-Fi function.
6.2.1 Network Settings
Purpose:
On the network settings interface, you can set network parameters of the device.
Steps:
1. Move the cursor to Network (network settings) by using direction keys.
2. Tap the # key to enter the network settings interface.
Figure 6-14 Network Settings Interface
3. Modify network parameters of the device, including IP address, subnet mask, and gateway address.
Tap the key to enter/exit the editing mode.
4. Move the cursor to the OK button, and tap the # key.
6.2.2 Serial Port Settings
Purpose:
When the access control terminal works as the RS-485 card reader, you should set serial port parameters.
Steps:
1. Move the cursor to Serial (serial port settings) by using direction keys on the communication settings interface.
2. Tap the # key to enter the serial port settings interface.
24
Page 29
Access Control Terminal·Quick Start Guide
Figure 6-15 Serial Port Settings Interface
3. Modify parameters of the serial port, including working mode, Baud Rate, and RS-485 address.
Working Mode: When the access control terminal works as the terminal, you can connect it to Card Reader, Client Software
and Control Unit.
Set the working mode of the serial port as Connect to Card Reader if the access control terminal is connected to the
external card reader.
If the terminal is worked as the card reader, Working Mode cannot be used.
Baud Rate: It will display the Baud Rate configured on the client software.
RS-485 Address: When the access control terminal works as a card reader, the RS-485 address should be configured.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
4. Move the cursor to the OK button, and tap the # key.
Reboot the device after changing the working mode.
6.2.3 Wiegand Settings
Purpose:
When the access control terminal works as the Wiegand card reader, you should set Wiegand parameters.
Steps:
1. Move the cursor to Wiegand (Wiegand settings) by using direction keys on the communication settings interface.
2. Tap the # key to enter the Wiegand settings interface.
Figure 6-16 Wiegand Settings Interface
3. Edit parameters of the serial port, including the Wiegand direction and the Wiegand mode.
Wiegand Direction:
1) In the terminal mode, select whether to Receive or to Send. In the Receive mode, the mode cannot be changed.
2) In the card reader mode, only Send is supported.
Wiegand Mode: The default Wiegand mode is Wigand 34.
25
Page 30
Access Control Terminal·Quick Start Guide
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
4. Move the cursor to the OK button, and tap the # key.
Reboot the device after changing the Direction.
6.2.4 Wi-Fi Settings
Steps:
1. Move the cursor to Wi-Fi (Wi-Fi settings) by using direction keys on the communication settings interface.
2. Tap the # key to enter the Wi-Fi settings interface.
Figure 6-17 Wi-Fi Enabling
3. Move the cursor to and tap the # key to enable the WLAN.
Figure 6-18 Wi-Fi Selection
4. Move the cursor to a network, and tap # key to enter the network connection interface.
Figure 6-19 Wi-Fi Settings
5. Enter the password of the network. The password supports numbers, letters (uppercase and lowercase) and symbols.
6. Edit the IP mode, IP address, subnet mask, and gateway address.
7. Move the cursor to the OK button, and tap the # key.
26
Page 31
Access Control Terminal·Quick Start Guide
Tap the key to enter and exit the editing mode.
6.3 System Settings
Purpose:
On the system settings interface, you can set system parameters, manage the data, restore default settings, set access control
parameters, and set cameras.
Steps:
1. Move the cursor to System (system parameters) by using direction keys.
2. Tap the # key to enter the system parameters interface.
Figure 6-20 System Settings Interface
System Parameters: System parameters of the device include the device running mode, login password, and prompt sound.
Data Management: It is used to manage the storage data of the device, including Delete Card Parameters, Delete Event Only, and
Delete Picture Only.
Restore Settings: The device can be restored into factory defaults or default settings.
Access Control Settings: You can set parameters of the access control terminal, including Controller Authentication, Card Reader
Authentication, Door Action Time, Delayed Door Alarm, and Anti-passing Back.
Camera Settings: You can set the camera for the access control terminal (only supported by terminal with the model of -C).
Camera Settings will be displayed on the screen when the access control terminal has the function.
6.3.1 Setting System
Steps:
1. Move the cursor to System (system parameters) by using direction keys on the system settings interface.
2. Tap the # key to enter the system parameters interface.
Figure 6-21 System Parameters Interface
3. Modify system parameters, including switching the mode, entering the login password, and enabling voice prompts.
Mode: The device mode can be switched between Controller and Card Reader. After switching the mode, the system can
automatically reboot and enter into the interface of the new mode.
If the access control terminal works as a card reader, you should configure the serial port setting and the Wiegand
setting. See details in Chapter 6.2.2.
27
Page 32
Access Control Terminal·Quick Start Guide
If the access control terminal is in the card reader mode, the terminal works as a card reader to access to the access
controller or another access control terminal via RS-485 and Wiegand.
If the access control terminal is in the card reader mode, the terminal will send the fingerprint via RS-485, the client
software and the local.
If the access control terminal is in the card reader mode, the terminal supports swiping card and scanning fingerprint.
When scan the fingerprint, the bound card No. should contain 10 numbers. Or the fingerprint scanning will be failed.
Login Password: To reset the login password of the device, you should enter a new password, and confirm it.
Voice Prompts: After enabling voice prompts, you can hear the voice prompts to notify you the card status when you swipe the
card. Otherwise, you will hear the beeper in place of the voice prompts.
Beep three times: legal card.
Beep four times: illegal card.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
4.Move the cursor to the OK button, and tap the # key.
6.3.2 Managing Data
Purpose:
On the data management interface, you can delete the storage data of the device.
Steps:
1. Move the cursor to Data (data management) by using direction keys in the system settings Interface.
2. Tap the # key to enter the data management interface.
Figure 6-22 Data Management Interface
Move the cursor to Delete Card Parameters, Delete Event Only, or Delete Picture Only.
Delete Card Parameters: Delete all cards parameters registered in the device.
Delete Event Only: Delete all access events in the system.
Delete Picture Only: Delete all captured pictures in the system.
This function is only supported by terminal with the model of –C.
3. Tap the # key.
6.3.3 Restoring Settings
Purpose:
On the restore settings interface, you can restore Factory Defaults or Default Settings.
Steps:
1. Move the cursor to Reset (restore settings) by using direction keys on the system settings interface.
2. Tap the # key to enter the restore settings interface.
28
Page 33
Access Control Terminal·Quick Start Guide
Figure 6-23 Restore Settings Interface
3. Move the cursor to Factory Defaults or Default Settings.
Factory Defaults: After restoring factory defaults, all parameters of the device are returned to the factory defaults.
Default Settings: After restoring defaults settings, parameters, excluding network parameters and event parameters, are
returned to the factory defaults.
4. Tap the # key.
5. Move the cursor to the OK button, and tap the # key.
6.3.4 Door Settings
Purpose:
On the door settings interface, you can set door parameters, including Controller Authentication, Card Reader Authentication, Door
Action Time, Delayed Door Alarm, and Anti-passing Back.
Steps:
1. Move the cursor to ACS (door settings) by using direction keys in the system settings interface.
2. Tap the # key to enter the door settings interface.
Figure 6-24 Door Settings Interface
3. Edit door parameters.
Controller Authentication: Set the controller authentication mode for opening the door, that is, Card Only, Fingerprint Only,
Card/Fingerprint, Card & Fingerprint, Card & Password, Fingerprint & Password, Card & Fingerprint & Password.
Card Reader Authentication: Set the card reader authentication mode for opening the door, that is, Card Only, Fingerprint Only,
Card/Fingerprint, Card & Fingerprint, Card & Password, Password & Fingerprint, Card & Password & Fingerprint.
Door Action Time: Set the door action time: 1 ~ 255 s.
Delayed Door Alarm: Set the delayed door alarm threshold: 1 ~ 255 s.
Anti-Passing Back: Set whether to enable the function of anti-passing back.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
4.Move the cursor to the OK button, and tap the # key.
6.3.5 Setting the Camera
Purpose:
On the camera settings interface, you can set camera parameters.
29
Page 34
Access Control Terminal·Quick Start Guide
This function is only supported by terminal with the model of –C.
Steps:
1. Move the cursor to Camera (camera settings) by using direction keys in the system settings Interface.
2. Tap the # key to enter the camera settings interface.
Figure 6-25 Camera Settings Interface
3. Edit camera parameters.
Enable Face Detection: When enabling face detection, the system can detect the face.
Enable Card No. Overlay: When enabling card No. overlay, captured pictures can be overlaid on the card information.
Display Picture: When enabling to display the picture, captured pictures can display on the screen.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
The captured pictures can be saved in the SD card.
4.Move the cursor to the OK button, and tap the # key.
6.4 Time Settings
Steps:
1. Move the cursor to Time (time settings) by using direction keys.
2. Tap the # key to enter the time settings interface.
Figure 6-26 Time Settings Interface
3. Edit time parameters.
Date/Time: Edit the data and the time of the device.
DST (Daylight Saving Time): When enabling DST, you should set the bias time, the start time, and the end time of DST.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between “Yes” mode and “No” mode.
4. Move the cursor to the OK button, and tap the # key.
30
Page 35
Access Control Terminal·Quick Start Guide
6.5 Upload/Download Settings
Purpose:
On the upload/download interface, you can upgrade the device, upload the door parameters, download access parameters,
download captured pictures, and download attendance record.
Steps:
1. Plug a USB disk into the access control terminal.
2. Move the cursor to Transfer (upload/download) by using direction keys.
3. Tap the # key to enter the upload/download interface.
Figure 6-27 Upload/Download Interface
4. Move the cursor to Device Upgrade, Upload Access Settings, Download Access Settings, Download Attendance Record, or
Download Captured Picture.
Device Upgrade: The system can automatically read the upgrading information from the USB, and upgrade the device.
The upgrading file should be put in the root directory.
Upload Access Settings: The system can automatically read the access parameters from the USB, and upload them to the
device.
Download Access Settings: The system can automatically download access parameters into the USB.
Download Attendance Record: The system can automatically download attendance records into the USB.
Download Captured Picture: The system can automatically download captured pictures into the USB. Click the # key.
The supported USB format is FAT32 and NTFS.
6.6 Testing
Purpose:
On the test interface, you can do voice test, keypad test, RTC test, and camera test.
Steps:
1. Move the cursor to Test by using direction keys.
2. Tap the # key to enter the test interface.
Figure 6-28 Test Interface
3. Move the cursor to select Voice Test, Keypad Test, RTC Test, or Camera Test to do corresponding test.
Voice Test: You can hear a voice prompt “Voice prompt succeeds” after click the # key.
31
Page 36
Access Control Terminal·Quick Start Guide
Keypad Test: On the keypad test interface, if the keypad test succeeds, the screen will display corresponding numbers or
functions of the keypad you click.
RTC Test: On the RTC test interface, if the test succeeds, the screen will display the synchronization time.
Camera Test: On the camera test, if the camera test succeeds, the screen will display the real-time picture the camera
captures.
This function is only supported by terminal with the model of –C.
6.7 Log Query Settings
Steps:
1. Move the cursor to Log (log query settings) by using direction keys.
2. Tap the # key to enter the log query interface.
Figure 6-29 Log Query Interface
3. Enter the card number.
Enter the card number by swiping the card.
Place the card close to the screen.
Enter the card number manually.
1) Tap the key to enter the text editing mode.
2) Enter the card number in the textbox.
3) Tap the key to exit the text editing mode.
4. Set the start/end time.
Tap the key to enter and exit the editing mode.
5. Move the cursor to the OK button, and tap the # key.
On the log query display interface, you can view the card number, swiping time, and card reader ID.
6.8 System Information
Steps:
1. Move the cursor to Info (system information) by using direction keys.
2. Tap the # key to enter the system information interface.
Figure 6-30 System Information Interface
3. Move the cursor to Record Capacity or Information by using Left/Right direction keys.
32
Page 37
Access Control Terminal·Quick Start Guide
Record Capacity
Card Capacity: It refers to the maximum amount of cards.
The default maximum card amount is 100,000.
Fingerprint Capacity: It refers to the maximum amount of fingerprints.
Fingerprint capacity only supports devices with fingerprint registration function.
The default maximum fingerprint amounts of devices with fingerprint registering function are as follows.
Optical device: 9500
DS-K1T105 series model does not support this function.
Device Information
In the device information interface, you can view the device name, the serial No., Mac address, and so on.
Figure 6-31 Device Information Interface
33
Page 38
Side
Edge II
Vertical
Edge I
Access Control Terminal·Quick Start Guide
Appendix: Tips for Scanning Fingerprint
Recommended Finger
Forefinger, middle finger or the third finger.
Correct Scanning
The figure displayed below is the correct way to scan your finger:
You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
Incorrect Scanning
The figures of scanning fingerprint displayed below are wrong:
Environment
The scanner should avoid direct high light, high temperature, humid conditions and rain.
When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your finger and scan again after drying the
finger.
Others
If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods.
If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again.
0101001060602
34
Page 39
Access Control Terminal·Quick Start Guide
35
Loading...
+ hidden pages