SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
AS07GS1ERA
AS09GS1ERA
AS12GS1ERA
Contents
PARTS AND FUNCTIONS |
|
|
|
|
|
|
2 |
|||||
|
|
|
|
|
|
|||||||
OPERATION |
|
|
|
|
|
|
|
|
3 |
|||
|
|
|
|
|
||||||||
INDOOR UNIT INSTALLAION |
|
|
|
|
5 |
|||||||
|
||||||||||||
MAINTENANCE |
|
|
|
|
9 |
|||||||
|
|
|||||||||||
CAUTIONS |
|
|
|
10 |
||||||||
|
|
|||||||||||
TROUBLE SHOOTING |
|
|
11 |
|||||||||
|
|
●Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010535380
Parts and Functions
|
|
Indoor Unit |
|
|
|
Remote controller |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18
|
2 |
|
|
|
3 |
|
|
|
|
4 |
6 |
|
|
7 |
|
|
|
5 |
|
|
|
|
|
1 |
Inlet |
6 |
Display board |
2 |
Inlet grille |
7 |
Emergency Switch |
3 |
Outlet |
8 |
Air Purifying Filter |
4 |
Vertical blade |
|
(inside) |
|
|
(adjust left and right air flow)
5 Horizontal flap
(adjust up and down air flow.
Don't adjust it manually)
Please be subject to the actual produce purchased the above picture is just from your reference
Outdoor Unit
|
4 |
OUTLET |
CONNECTING PIPING AND ELECTRICAL WIRING |
INLET |
DRAIN HOSE |
Please be subject to the actual produce purchased the above picture is just from your reference
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Pressor
to set correct time. Each press will increase or decrease 1min. If the button is kept pressed,time will change quickly. After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
POWER/SOFT
TIMER
CLOCK
LIGHT
SET SLEEP
LOCK RESET
1 |
10 |
|
6 |
||
2 |
||
7 |
||
|
||
5 |
8 |
|
3 |
9 |
|
4 |
||
ON/OFF |
||
13 |
11 |
|
|
||
FAN |
|
|
18 |
|
|
MODE |
|
|
SWING |
15 |
|
|
|
POWER/SOFT |
23 |
|
TIMER |
|
|
12 |
|
|
|
|
|
20 |
|
21 |
CLOCK |
|
14 |
LIGHT |
|
||
19 |
|
16 |
|
SET |
SLEEP |
||
17 |
LOCK |
RESET |
22 |
|
|
1. Mode display
Operation mode AUTO COOL DRY HEAT FAN
Remote controller
2.SWING display
3.FAN SPEED display
AUTO LO MED HI
4.SLEEP display
5.LOCK display
6.SIGNAL SENDING
7.TIMER OFF display
8.TIMER ON display
9. CLOCK display 10.TEMP display
11.POWER ON/OFF button
12.MODE button
13.FAN button
14.HOUR button
15.SWING button
16.SLEEP button
17.LOCK button
Used to lock buttons and LCD display.
18.TEMP.SETTIN button
19.SET / LIGHT button
20.TIMER button
21.CLOCK button
Used to set correct time. 22. RESET button
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
23. HOUR / POWER/SOFT button Used to set clock and timer setting. Every time the button is pressed, display changes as follows:
BLANK
POWER SOFT
Loading of the battery
|
|
1Remove the battery cover; |
|
|
2 Load the batteries as illustrated. |
||
|
|
2 R-03 batteries, resetting key |
|
|
|
(cylinder); |
|
|
|
3 Be sure that the loading |
|
4 |
is in line with the" + "/"-"; |
||
|
|||
Load the battery,then put on the cover again. |
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or changeover type fluorescent lamp or wireless telephone is installed in the room, the recei ver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the batteries have been used up.Please change batteries.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
2
Operation
Base Operation
Remote controller |
ON/OFF |
||
|
|
||
|
|||
|
|
FAN |
|
|
|
|
|
|
|
MODE |
|
|
|
|
|
|
|
SWING |
|
|
|
POWER/SOFT |
|
|
TIMER |
||
|
CLOCK |
||
|
LIGHT |
|
|
|
SET |
SLEEP |
LOCK RESET
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
|
AUTO |
COOL DRY |
HEAT |
FAN |
|
3.Select temp.setting |
|
|
|
||
Press |
|
button |
|
|
|
|
Every time the button is pressed, temp.setting |
||||
|
increase 1oC,if kept depressed, it will increase |
||||
|
rapidly |
|
|
|
|
|
Every time the button is pressed, temp.setting |
||||
|
decrease 1oC,if kept depressed, it will |
|
|||
|
decrease |
rapidly |
|
|
|
Select a desired temperature. |
|
|
|
||
4.Fan speed selection |
|
|
|
||
Press FAN button. For each press, fan speed |
|
||||
changes as follows: |
|
|
|
||
Remote controller: |
|
|
|
||
|
|
AUTO |
LO |
MED |
HI |
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation |
Remote |
Note |
|||||
Mode |
Controller |
||||||
|
|||||||
|
|
|
|
|
|
Under the mode of auto operation, air conditioner |
|
AUTO |
|
|
|
|
|
will automatically select Cool or Heat operation |
|
|
|
|
|
|
according to room temperature When FAN is set |
||
|
|
|
|
|
|
to AUTO the air conditioner automatically adjusts |
|
|
|
|
|
|
|
the fan speed according to room temperature. |
|
COOL |
|
|
|
|
|
|
|
|
|
|
|
|
|
In DRY mode, when room temperature becomes |
|
DRY |
|
|
|
|
|
lower than temp.setting+2o C, unit will run |
|
|
|
|
|
|
intermittently at LOW speed regardless of FAN |
||
|
|
|
|
|
|
setting. |
|
|
|
|
|
|
|
In HEAT mode, warm air will blow out after a short |
|
HEAT |
|
|
|
|
|
period of the time due to cold-draft prevention function. |
|
|
|
|
|
|
When FAN is set to AUTO, the air conditioner automatically |
||
|
|
|
|
|
|
adjusts the fan speed according to room temperature. |
|
|
|
|
|
|
|
In FAN operation mode , the unit will not operate in |
|
FAN |
|
|
|
|
|
COOL or HEAT mode but only in FAN mode , |
|
|
|
|
|
|
AUTO is not available in FAN mode. And temp. |
||
|
|
|
|
|
|
setting is disabled. In FAN mode, sleep operation |
|
|
|
|
|
|
|
is not available. |
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while.
When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room |
Designated |
Timer |
Fan |
Operation |
emergency |
temperature |
temperature |
mode |
speed |
mode |
operation switch |
|
|
|
|
|
Above 23oC |
26oC |
|
AUTO |
Pi |
No |
COOL |
|||
Below 23oC |
23oC |
No |
AUTO |
HEAT |
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16oC, do not use it in the
normal operation.
Continue to press the test operation
switch for more than 5 seconds. After
you hear the "Pi" sound twice, release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor unit will run in high speed.
test operation switch
Pi
Pi
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1 blank Pos.2 Pos.3
Pos.4 (Auto swing)
2.Left and right air flow adjustment(manual)
Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.
'
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
3
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
1OC higher than temp.setting.After another 1 hours, temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts |
SLEEP operation stops |
|
|
Approx.6hrs |
|
1 hr |
Rises 1OC |
1 hr |
Rises 1OC |
|
|
|
|
Temp.setting |
|
Unit stop |
In COOL, DRY mode
2. In HEAT mode
1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2OC futher.After more another 3hours,temp.rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
Temp.setting |
Unit stop |
|
1 hr |
Decreases 2OC |
|
|
1 hr |
|
|
Decreases 2OC |
|
|
|
3 hrs |
|
3 hrs |
Rises 1OC |
SLEEP |
|
SLEEP |
operation starts |
operation stops |
In HEAT mode
3.In AUTO mode
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5. When quiet sleeping function is set to 8 hours, the quiet sleeping time can not be adjusted. When TIMER function is set , the quiet sleeping function can't be set up. After the sleeping function
is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first, the unit will stop automatically, and the other mode will be cancelled.
Power Failure Resume Function
1. If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running.
2. Note to the power failure resume:
press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.
POWER/SOFT Operation
(1) POWER Operation
When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode.
(2) SOFT Operation
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed automatically takes low speed of AUTO fan mode.
Note
During POWER operation, in rapid HEAT or COOL mode the room will show uniform temperature distribution. Long period
SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again, POWER or SOFT disappears.
4