Fubag BS 2200, BS 3300 User Manual [ru]

0 (0)

Operator's Manual

Инструкция поэксплуатации

Электростанция бензиновая

Power station

BS 2200

BS 3300

www.fubag.ru

Operator's manual

www.fubag.ru

WARNING! BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!

Our generators FUBAG are designed to give safe anddependable service if operated according to instructions.

Read and understand the manual before operating the generator FUBAG. Failure to do so could result in personal injury or equipment damage.

1. General safety

WARNING!

WARNING!

Exhaust gas contains poisonous carbon monoxide.

Never run the generator in an enclosed area. Be sure to provide adequate ventilation. When installed in ventilated protection are to be observed.

The muffler becomes very hot during operation and remains hot for a while after stopping the engine.

Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine.

To prevent scalding, pay attention to the warning marks attached to the generator.

WARNING! Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped.

Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location.

Wipe up spilled gasoline at once.

WARNING! Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn or cause fires in the building's electrical system.

- 1 -

Operator's manual

 

www.fubag.ru

WARNING!

- Always make a pre-operation inspection before you start the engine. You

may prevent an accident or equipment damage.

 

-Place the generator at least 5m away from buildings or other equipment during operation.

-Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.

-Know how to stop the generator quickly and understand operation of all the controls.Never permit anyone to operate the generator without proper instructions.

-Keep children and pets away from the generator when it is in operation.

-Keep away from rotating parts while the generator is running.

-The generator is a potential source of electrical shocks when misused; do not operate with wet hands.

-Do not operate the generator in rain or snow and do not let it get wet.

-The power generator is a mains replacement that generates electrical power for supply to a mobile distribution system.

-The power generator must be operated outdoors within the prescribed voltage, output and rated speed limits (see type plate).

-The power generator must not be connected to other electrical supply systems or electric generation systems (e.g. other power generators).

-The power generator may not be used in environments where there is a risk of explosion.

-The power generator may not be used in environments where there is a risk of fire.

-The power generator must be operated in accordance with the conditions set out in the technical documentation.

-All improper use of the power generator including all uses not described in these instructions will constitute unauthorized incorrect usage for which the manufacturer is not legally liable.

-Operation in environments where there is a risk of explosion and fire.

-Operation in enclosed areas and under direct exposure to rain or snowfall.

-Operation without the requisite safety precautions and connected to existing supply network systems.

-Spraying with high-pressure cleaners or fire extinguishing equipment.

-Non-compliance with regular servicing requirements.

-Failure to carry out measurements and checks for early detection of defects.

-Know and apply the Prevention of Injury regulations and the safety instructions for the power generator.

-Understand and be able to practically implement the technical documentation.

-The operator must know the functions of, and be able to use, the components of the power generator.

-The operator must wear the appropriate personal safety equipment.

-The labelling on the electrical generator must be complete and maintained in a readable condition.

-Constructive changes may not be carried out on the electrical generator.

-The rated speed of the motor has been set during manufacture and may not be changed.

-The operating safety and correct functioning must be checked before and after each use.

-No naked flames, lights or spark-emitting appliances may be used within the hazard area of the power generator.

-Smoking within the hazard area of the power generator is strictly forbidden.

-During operation, the power generator must be protected from dirt and foreign matter.

-The power generator may only be transported when cold.

-The power generator may only be lifted using the carry handles intended for this purpose.

-The electrical safety must be checked before each operational use.

-The appliance may not be covered. The air intake may not be blocked or obstructed.

-When starting, the load may not be connected.

-Only certified and approved cables may be used for the wired network.

-The power drawn may not exceed the maximum rated power.

-2 -

Operator's manual

www.fubag.ru

-The power generator may not be operated without the sound absorber.

-The power generator may not be operated without the air filter or with the air filter cover open.

-The generator's tank may not be refilled during operating.

-The tank may not be refilled when the power generator is hot.

-The power generator may not be cleaned and serviced when in operation; when hot.

-Always remove spark plug connector prior to commencing servicing and repair work.

-The power generator must be shut down when not required for periods longer than 30 days.

-The power generator must be stored in a dry enclosed room.

2.Safety symbols

1. Precautions that involve your safety.

2.Start and run the generator outdoors. Do not run the generator in an enclosed area, even if doors or windows are open.

3.To reduce the risk of serious injury, avoid attempting to touch the hot

surface.

4.Units should not be operated or stored in wet or damp conditions or on highly conductive locations such as metal decking and steel work.

5.Could not use under the rain.

6.Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

7.Ear protection.

8.Read carefully and understand operator manual prior to operation of this

product. Follow all warnings and instructions.

- 3 -

Operator's manual

 

 

 

 

www.fubag.ru

3. Specifications

 

 

 

 

 

 

 

 

 

 

 

Model

BS 2200

 

BS 3300

 

 

Generator type

 

Synchro

 

 

Rated frequency/ IP

50 Hz / IP 23

 

50 Hz / IP 23

 

 

Rated voltage

230 V 1~

 

230 V 1~

 

 

Max. output

2,2 kWA

 

3,3 kWA

 

 

Rated output

2,0 kW

 

3,0 Kw

 

 

Cos φ

 

1

 

 

Motor type

1-cylinder, 4-stroke, air-cooled

 

 

Starter

recoil starter

 

 

Motor power

5,8 hp

 

5,8 hp

 

 

Tank capacity

15 l

 

15 l

 

 

Noise level

97dB(A)

 

97dB(A)

 

 

Relative humidity

 

0-75%

 

 

Dimension, LxWxH

600х450х460 mm

 

600х450х460 mm

 

 

Weight

42 kg

 

49 kg

 

The manufacturer reserves himself the right to make the manual's content or power generator function change without any preliminary notification of the users.

4. Description

1. SOCKET

2. CIRCUIT BREAKER

3. FUEL GAUGE

4. DIGITAL DISPLAY

5. FUEL TANK CAP

6. ENGINE SWITCH

7. FUEL VALVE

8. CHOKE LEVER

9. RECOIL STARTER

10. OIL DRAIN PLUG

11. OIL FILLER CAP

12. EARTH TERMINAL

- 4 -

Operator's manual

www.fubag.ru

14. AIR CLEANER

15. SPARKPLUG

16. FUELTANK

17. MUFFLER

DIGITAL DISPLAY

A - Digital display

B - AC voltage indicator

C - Frequency indicator

D - Hour indicator

E - Low lubricant alert

F - Select button

- 5 -

Fubag BS 2200, BS 3300 User Manual

Operator's manual

www.fubag.ru

5. Pre-Operation checks

Check engine oil

-Before checking or refilling oil, be sure the generator is put on a stable and level surface with engine stopped.

-Remove oil filler cap and check the engine oil level.

-If oil level is below the lower level line, refill with suitable oil (see table below) to upper level line. Do not screw in the oil filler cap when checking oil level.

-Change oil if contaminated.

Single grade

Multi grade

Ambient temperature

- 6 -

Operator's manual

www.fubag.ru

Check engine fuel

WARNING!

-Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur.

-Close fuel cock before refueling with fuel.

-Do not refill tank while engine is running or hot.

-Be careful not to admit dust, dirt, water or other foreign objects into fuel.

-Wipe off spilt fuel thoroughly before starting engine.

-Keep open flames away.

EMPTY

FULL

-Check fuel level at fuel gauge.

-If fuel level is low, refill with unleaded automotive gasoline.

-Be sure to use the fuel filter screen on the fuel filter

neck.

Fuel tank capacity 15l.

Checking components

Check following items before starting engine:

-fuel leakage from fuel hose.

-bolts and nuts for looseness.

-components for damage or breakage.

- 7 -

Operator's manual

www.fubag.ru

Checking generator surroundings

WARNING!

Make sure you review each warning in order to prevent fire hazard.

-Keep area clear of inflammables or other hazardous materials.

-Keep generator at least 3 feet (1 meter) away from buildings or other structures.

-Only operate generator in a dry, well ventilated area. Keep exhaust pipe clear of foreign objects.

-Keep generator away from open flame.

-Keep generator on a stable and level surface.

-Do not block generator air vents with paper or other material.

6. Operating procedures

Starting

(а) Set the engine switch to "ON" position.

(b) Open the fuel cock.

ОPEN

(с) Set the choke lever to "CLOSE" (arrow mark). Not necessary if the engine is warm.

CLOSE

- 8 -

Operator's manual

www.fubag.ru

(d) Pull the starter handle slowly until resistance is felt. This is the "Compression" point. Return the handle to its original position and pull swiftly.

Do not fully pull out the rope. After starting, allow the starter return to its original position while still holding the handle. If the engine fails to start after several attempts, repeat above procedures with choke lever returned "OPEN" position.

(е) After the engine started, return the choke lever gradually to "OPEN" position.

ОPEN

(f) Warm up the engine without load for a few minutes.

Using electric power

(а) Check the digital display for proper voltage. This generator is thoroughly tested and adjusted in the factory.

If the generator does not produce the specified voltage, consult your nearest FUBAG generator dealer.

(b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.

(с) lnsert the plug(s) of the electrical appliance(s) into the receptacle.

WARNING:

-Be sure to ground the generator if the connected electrical equipment is grounded.

-9 -

Loading...
+ 23 hidden pages