Comfort & Convenience

New design makes controls more accessible

Remote control

24-hour timer

Smart Fan auto-adjusts fan speed to maintain desired temperature

Check filter reminder

3-speed fan

Auto restart

Electronic defrost control

Individually adjustable louvers direct air flow where you need it

Washable, antimicrobial filter

Energy Savings

Money Saver® setting cycles the fan with the compressor

ENERGY STAR® qualified models

R-410A refrigerant

Durability & Quality

Rotary compressor provides quiet, dependable performance

Premium aluminum exterior grille

Dense blower insulation blocks outdoor noise

Rifled copper tubing

Impact resistant front cover

High tech fins with sine wave lanced louvers increase energy efficiency by increasing surface area for heat exchange

Thru-the-wall_WallMaster_Submittal_2016

Installation Features

Mounts flush with the exterior wall for a neat appearance

Ideal for thicker wall installations, where side fins don’t fit

A high efficiency replacement for 27” sleeves including Fedders A and B*. Sleeve measures 27” W x 16 3/4” H

Accessories

AG architectural grille for use with WSE sleeve

Drain kit for condensate disposal

Internal drain kit for new construction applications where condensate drain system is built-in

WSE sleeve ships with inside and outside steel weather panels and standard exterior grille.

Baffle adapter kit for use with deep sleeve installations (Fedders B sleeves).

FITS EXISTING FEDDERS SLEEVES.

Sleeve Dimensions

Friedrich

Fedders

Fedders

WSE Sleeve

A Sleeve

B Sleeve

 

 

 

 

Height (inches)

16 3/4

16 3/4

16 3/4

 

 

 

 

Width (inches)

27

27

27

 

 

 

 

Depth (inches)

16 3/4

16 3/4

19 3/4

 

 

 

 

CHASSIS DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

 

Minimum

 

 

 

 

 

 

 

 

 

Height

Width of

 

with

 

Extension Into Room

 

 

 

Height

Width

Depth

of Front

Front

 

 

Front

 

 

with Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis

 

15 3/4"

26 1/2"

16 1/4"

17 1/4"

27 1/2"

 

23 1/4"

 

 

7 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

WSE SLEEVE DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

Minimum

 

 

Thru-the-wall

 

 

 

 

 

 

 

 

 

 

 

Finished Hole

 

 

 

 

 

 

 

 

with

 

Extension

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Width

Depth

Front

Outside

 

Height

 

Width

Max. Depth

 

 

 

 

 

 

 

 

 

 

WSE Sleeve

16 3/4"

27"

16 3/4"

24 1/4"

9/16"

 

17 1/4"

27 1/4"

15 5/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis requires WSE sleeve (sold and shipped separately)