Flowserve Worcester Controls Supplement 3 ACCESS I User Manual

[File]
DescText = “DeviceNet Network”;
CreateDate = 12-6-1999;
CreateTime = 9:04:46;
ModDate = 12-6-1999;
ModTime = 9:04:46;
Revision = 2.0;
[Device]
ProdType = 7;
ProdCode = 2112;
MajRev = 4;
MinRev = 118;
VendName = “Worcester Controls Corporation”;
ProdTypeStr = “General Purpose Discrete I/O”;
ProdName = “ACCESS/DeviceNet”;
Catalog = “07159”;
[IO_Info]
Default = 0x0001;
PollInfo = 0x0001,1,1;
Input1 = 11,0,0x0001, “Producing IO/Data”,6,“20 04 24 65 30 03”,“Help”;
Output1 = 1,0,0x0001, “Consuming IO/Data”,6,“20 04 24 66 30 03”,“Help”;
[Params]
Param1 =
0, $ parameter value slot
6, “20 08 24 01 30 03”, $ link size and path
0x32, $ descriptor
4, 1, $ data type, 1 byte(s)
“Input State Instance 1”, $ parameter name
“”, $ units string
“Discrete Input Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param2 =
0, $ parameter value slot
6, “20 08 24 02 30 03”, $ link size and path
0x32, $ descriptor
4, 1, $ data type, 1 byte(s)
“Input State Instance 2”, $ parameter name
“”, $ units string
“Discrete Input Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
FCD WCAIM2022-01
(Part 14120)
Worcester Controls Supplement 3 ACCESS I and M DeviceNet EDS File
Installation, Operation and Maintenance Instructions
$ Advanced DeviceNet Monitor Electronic Data Sheet
$ Complies with EDS File Syntax Checking Utility – 02.02
2 Supplement 3: ACCESS I and M DeviceNet EDS File WCAIM2022
Flow Control
Worcester Controls
Param3 =
0, $ parameter value slot
6, “20 08 24 03 30 03”, $ link size and path
0x32, $ descriptor
4, 1, $ data type, 1 byte(s)
“Input State Instance 3”, $ parameter name
“”, $ units string
“Discrete Input Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param4 =
0, $ parameter value slot
6, “20 09 24 01 30 03”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“State Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param5 =
0, $ parameter value slot
6, “20 09 24 01 30 04”, $ link size and path
0x32, $ descriptor
4, 1, $ data type, 1 byte(s)
“Status Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param6 =
0, $ parameter value slot
6, “20 09 24 01 30 05”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“Fault Action Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param7 =
0, $ parameter value slot
6, “20 09 24 01 30 06”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“Fault Value Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param8 =
0, $ parameter value slot
6, “20 09 24 01 30 07”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“Idle Action Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param9 =
0, $ parameter value slot
6, “20 09 24 01 30 08”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“Idle Value Instance 1”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;
Param10 =
0, $ parameter value slot
6, “20 09 24 02 30 03”, $ link size and path
0x03, $ descriptor
4, 1, $ data type, 1 byte(s)
“State Instance 2”, $ parameter name
“”, $ units string
“Discrete Output Point\n\n”,
0,1,0,
1,1,1,0,0,0,0,0,0;