FingerTec AdapTec Plus User Manual

Installer Guide
Adaptability to Enhanced Security
AdapTec Plus combines power supply and door access controller features in a compact metal casing for an encrypted and secure I/O function, en­hancing door access control functionalities and easing installation proc­esses. The AdapTec Plus is an exceptional FingerTec accessory in a small package!
UNDERSTANDING ADAPTEC PLUS FUNCTIONS
It supports FingerTec encrypted 26-bit Wiegand communication output; providing enhanced security level for extra protection.
Power Up Terminals & Door Lock Systems
A single AdapTec Plus can provide power simultaneously to a maximum 2 units of FingerTec terminals and 2 sets of door lock accessories such as EM Lock and drop bolt in one single system installation.
Prolonged Life Span of Hardware
With data encryption, the life span of the terminals could be prolonged without the risk of short circuiting when using AdapTec Plus.
Control IN/OUT Terminals At An Entrance
AdapTec Plus is a perfect choice for an IN/OUT installation, where a door is controlled both, at the entrance and the exit.
Support Rechargeable Backup Battery
Connects well to any 12V rechargeable backup battery, providing power to ensure protection of access during any events of power failure.
2
Emergency Alerts with Siren
Compatible with an NC siren type with a maximum of 0.5A load for emer­gency event e.g if the terminal is being illegally dismantled.
Seamless Integration with FingerTec Terminals
Mix and match the FingerTec terminals via AdapTec Plus for a cost effec­tive access control system suitable for small and medium sized offices.
Choose a DIY Metal Casing for Cleaner Installation
Store an AdapTec Plus and a backup battery in an exclusive FingerTec DIY metal casing, providing a cleaner installation.
SPECIFICATIONS
MODEL AdapTec Plus
PRODUCT DIMENSION (L X W X H), mm 198 x 45 X 131
WEIGHT 1.1 kg
CPU 8 MHz 16-bit microprocessor
POWER INPUT AC 110 ~ 240V (universal input)
POWER OUTPUT DC12V 3A - Supports up to:
2 x FingerTec access control terminals
• 2 x electrical energized locks
BACKUP POWER SYSTEM UPS or DC 12V rechargeable backup battery
INPUT SIGNAL FingerTec encrypted Wiegand signal
OUTPUT SIGNAL 2 x FORM C Relay
1 x 0.5A siren (max)
1 x DC12V 3A EM output (max)
DOOR LOCK • Electromagnetic locks
• Door strike
• Drop bolt/Dead bolt
OPERATING TEMPERATURE 0°C to 55°C
HUMIDITY 10% to 90% RH (non-condensing)
3
UNDERSTANDING THE DESIGN
AdapTec Plus consists of 2 main modules and a timer:
1 2 3
1
Power supply/power input module
2
Access control/power output module
3
Door lock timer
Power supply/power input module
2
1
1
This portion is to be connected to power source with AC110~240V. AC current will
be supplied into this side and a DC 12V 3A current will be generated as output.
2
These two cables, -V and +V are default and are connected to the inner part of
AdapTec. Please do not remove or change these cables.
Access control/power output module
1
1
These cables connect to a DC12V rechargeable backup battery. During a power failure,
the battery will power up the AdapTec Plus.
4
32
2
These are the power outputs from AdapTec. Refer to the wiring diagrams in page 3, for
details.
3
Power LED – a lit LED indicates power supply/power input module is working.
EM lock LED– a lit LED indicates that the AdapTec Plus is working to power up door
lock system.
Contact your local reseller or
support@fingertec.com in case either LED is not lit up.
Door lock timer
This is a Door Lock Timer
Lengthen timing
Shorten timing
Users can adjust the timing for the EM Lock and Drop Bolt to close after opening using the door lock timer. Turn the timer using a screwdriver; turning clockwise will lengthen the time, turning anti-clockwise will shorten the time.
Note: AdapTec Plus can be connected to other devices which have the same power con-
sumption. Please consult FingerTec’s advice through AdapTec with other FingerTec models.
info@fingertec.com before using
5
WIRING DIAGRAMS
AC900
FUNCTION • Time Attendance Only
STEP 1 • Connection Points
Access Control/Power Output Module
To Battery Tamper Siren EM Output Siren Door Wiegand Switch Output 12V Voltage Accept Exit Input
- + Input 12V 0V GND WD0 WD1
GND
DC 12V
Rechargeable
Backup Battery
PWR
Connection Points
AdapTec Plus
STEP 2 • Connect AdapTec Plus to a Power Source
Power Supply/Power Input Module
L N E -V
R B G
AC110~240V
L - Live
N - Neutral
E - Earth
R B G
Red
Blue
Green
STEP 3 • Turn on the power to use FingerTec AC900 for time attendance
only.