Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
Trademarks
EXFO’s trademarks have been identified as such. However, the presence
or absence of such identification does not affect the legal status of any
trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and
practices.
Patents
Feature(s) of this product is/are protected by pending design patents.
Version number: 6.0.0.1
iiFIP-400B
Contents
Certification Information ........................................................................................................v
1 Introducing the FIP-400B Fiber Inspection Probe and
ConnectorMax2 Mobile ................................................................................ 1
Service and Repairs ...............................................................................................................81
EXFO Service Centers Worldwide ..........................................................................................82
A Technical Specifications ..............................................................................83
B Fiber Inspection Probe Tip Compatibility Chart .......................................85
Index .................................................................................................................89
ivFIP-400B
Certification Information
Certification Information
North America Regulatory Statement
This unit was certified by an agency approved in both Canada and the
United States of America. It has been evaluated according to applicable
North American approved standards for product safety for use in Canada
and the United States.
Electronic test and measurement equipment is exempt from FCC part 15,
subpart B compliance in the United States of America and from ICES-003
compliance in Canada. However, EXFO Inc. makes reasonable efforts to
ensure compliance to the applicable standards.
The limits set by these standards are designed to provide reasonable
protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the user guide, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Modifications not expressly approved by the manufacturer could void the
user's authority to operate the equipment.
Fiber Inspection Probev
Certification Information
Your unit comes with an internal wireless module and antenna for which
the following information applies:
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
This device complies with the US/Canada portable RF exposure limit
set forth for an uncontrolled environment and is safe for intended
operation as described in this user documentation. The further RF
exposure reduction can be achieved if the device can be kept as far as
possible from the user’s body.
This device does not contain any user-serviceable components. Any
unauthorized product changes or modifications will invalidate
warranty and all applicable regulatory certifications and approvals.
viFIP-400B
Certification Information
European Community Declaration of Conformity
Warning: This is a class A product. In a domestic environment, this product
may cause radio interference in which case the user may be required to
take adequate measures.
Hereby, EXFO declares that the radio equipment type “Wide Band Data
Transmission” is in compliance with Directive 2014/53/EU.
An electronic version of the complete declaration of conformity for your
product is available on our website at www.exfo.com. Refer to the
product’s page on the Web site for details.
The information about the Wi-Fi frequency bands is as follows:
Between the frequencies 2400.0 MHz - 2483.5 MHz.
The maximum output power is 15 dBm.
This device is a 2.4 GHz wideband transmission system (transceiver),
intended for use in all EU member states and EFTA countries, except in
France and Italy where restrictive use applies.
In Italy, the end-user should apply for a license at the national spectrum
authorities in order to obtain authorization to use the device for setting up
outdoor radio links and/or for supplying access to telecommunications
and/or network services.
This device may not be used for setting up radio links in France, and in
some areas the RF output power may be limited to 10 mW EIRP in the
frequency range of 2454 - 2483.5 MHz. For detailed information, the
end-user should contact the national spectrum authority in France.
Fiber Inspection Probevii
1Introducing the FIP-400B Fiber
Status LED
Retaining nut
Focus
Magnification control
Capture control
Interchangeable
adapter tips
Micro USB adapter
connector
Battery compartment door
Battery LED
Wi-Fi LED
Inspection Probe and
ConnectorMax2 Mobile
The FIP-400B Fiber Inspection Probe is a portable video microscope used
to inspect fiber ends. Unlike traditional microscopes, the FIP-400B
facilitates the examination of patchcord connectors and also hard-to-reach
connectors on the back of patch panels and bulkhead adapters.
Probe
The FIP-400B is designed to be an intuitive, easy-to-use piece of
equipment. This video microscope is used for inspecting fiber ends.
Fiber Inspection Probe1
The focus knob can be turned in either direction to focus the image.
The magnification control button allows you to shift between three
levels of magnification. When pressed for one second, it activates the
auto focus.
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
Probe
The capture control button allows you to capture an image, perform an
analysis, or return to the Live Video mode.
The retaining nut holds tips securely in place, ensuring they are always
fastened in the correct position.
The status LED gives you information about the probe or the analysis
results.
The interchangeable adapter tips give you the possibility to use various
tips depending on the type of connector you are inspecting.
The micro USB adapter connector recharges the battery of the probe
when it is low. You can recharge the battery with the provided USB
cable and the adapter/charger that you connect to a power outlet. You
can also use the provided USB cable alone that you connect to a USB
port of a computer.
When the probe is connected to a power outlet or to a USB port, it still
works via Wi-Fi.
The battery compartment door is for battery replacement.
The probe comes equipped with a protective cap that fits over basic tips;
therefore, you do not need to remove the tip before putting the cap on.
2FIP-400B
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
Available Models
Available Models
The features available for your probe are automatically detected when you
connect it to your smart device. The table below shows which feature is
available for each model.
ModelsInspectionAuto analysis Auto centeringAuto focus Auto capture
FIP-425BXXX--
FIP-435BXXXXX
Note: When the internal temperature of the FIP-435B is too low, the probe
performs a warm-up that can last up to a minute.
Probe Tips
The FIP-400B comes with two interchangeable tips included in two
different packages (UPC or APC). Additional models are also available.
UPC package:
FIPT-400-FC-SC: FC-SC Bulkhead tip
FIPT-400-U25M: Universal patchcord tip (2.5 mm ferrule)
APC package:
FIPT-400-SC-APC: SC APC tip for bulkhead adapter
FIPT-400-U25MA: Universal patchcord tip for 2.5 mm ferrules
Other tip models are available for various bulkhead adapters and
patchcord connectors. For more information about tips and their use, see
the Fiber Inspection Probe Tip Compatibility Chart on page 85, or visit the
EXFO Web site.
Fiber Inspection Probe3
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
Status LED
Battery LED
Wi-Fi LED
LED Indicators
LED Indicators
The LED located on the probe gives you information about the probe or the
analysis results.
Status LEDStatus
Flashing blueProcessing in progress
Flashing red
There is a problem with the probe.
Follow the instructions on screen.
The auto focus is in timeout
There is an analysis error
BlueThe probe is ready and operational
RedIn Capture mode, current FIP result
status is Fail
GreenIn Capture mode, current FIP result
status is Pass
4FIP-400B
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
LED Indicators
Battery LEDStatus
Flashing blueUSB connected, battery charging
BlueUSB connected, battery fully charged
RedBattery error (only visible when
connected to a USB cable)
Flashing yellowUSB connected, battery not charging
because the battery temperature does
not allow the battery to charge
YellowUSB not connected, critical battery
level
Not litUSB not connected, battery above low
level
Wi-Fi LEDStatus
Blue Ready to transmit
Wireless transmission in progress
RedTransmission error
Not lit
Probe is off
OR
Probe is initializing
Fiber Inspection Probe5
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
Battery status
Name of the file
resulting from the
autonaming
Archive icon
User Preferences
Can be found in
the menu button
depending on the
smart device used.
Auto focus
ConnectorMax2 Mobile Software
ConnectorMax2 Mobile Software
ConnectorMax2 Mobile is the application used to view the fiber
inspections. You can also use specific test configurations and analyze the
fibers automatically upon capturing a picture.
6FIP-400B
Introducing the FIP-400B Fiber Inspection Probe and ConnectorMax2 Mobile
Conventions
Conventions
Before using the product described in this guide, you should understand
the following conventions:
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. Do not proceed unless you
understand and meet the required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in component damage. Do not proceed unless you
understand and meet the required conditions.
IMPORTANT
Refers to information about this product you should not overlook.
Note: The appearance and the orientation (portrait or landscape) of the
application may vary depending on the smart device used.
Fiber Inspection Probe7
2Safety Information
WARNING
Do not install or terminate fibers while a light source is active.
Never look directly into a live fiber and ensure that your eyes are
protected at all times.
WARNING
The use of controls, adjustments and procedures, namely for
operation and maintenance, other than those specified herein may
result in hazardous radiation exposure or impair the protection
provided by this unit.
IMPORTANT
When you see the following symbol on your unit , make sure
that you refer to the instructions provided in your user
documentation. Ensure that you understand and meet the required
conditions before using your product.
IMPORTANT
Other safety instructions relevant for your product are located
throughout this documentation, depending on the action to
perform. Make sure to read them carefully when they apply to your
situation.
CAUTION
Do not use the fiber probe outdoors in wet locations.
Fiber Inspection Probe9
Safety Information
Other Safety Symbols on Your Unit
Other Safety Symbols on Your Unit
One or more of the following symbols may also appear on your unit.
SymbolMeaning
Direct current
Alternating current
The unit is equipped with an earth (ground) terminal.
The unit is equipped with a protective conductor terminal.
The unit is equipped with a frame or chassis terminal.
On (Power)
Off (Power)
OR On/Off (Power)
Fuse
10FIP-400B
Safety Information
Electrical Safety Information
Electrical Safety Information
If you need to ensure that the unit is completely turned off, disconnect the
power cable and remove the battery.
WARNING
Use the external electrical power supply indoors only.
Position the unit so that the air can circulate freely around it.
Operation of any electrical instrument around flammable gases
or fumes constitutes a major safety hazard.
To avoid electrical shock, do not operate the unit if any part of
the outer surface (covers, panels, etc.) is damaged.
Only authorized personnel should carry out adjustments,
maintenance or repair of opened units under voltage. A person
qualified in first aid must also be present. Do not replace any
components while the power cable and battery are connected.
Capacitors inside the unit may be charged even if the unit has
been disconnected from its electrical supply.
Use only the listed and certified AC adapter/charger provided by
EXFO with your unit. It provides reinforced insulation between
primary and secondary, and is suitably rated for the country
where the unit is sold.
Fiber Inspection Probe11
Safety Information
Electrical Safety Information
Equipment Ratings
Tem pe ra tu re
Operation
Unit powered by batteries: -10 °C to 40 °C
(14 °F to 104 °F)
Unit connected to USB adapter: 0 °C to 40 °C
(32 °F to 104 °F)
Storage Unit without batteries: -40 °C to 70 °C
(-40 °F to 158 °F)
Unit with batteries: -20 °C to 60 °C
(-4 °F to 140 °F)
Relative humidity
a
unit: 95 % non-condensing
USB adapter: 5 % to 95 % for storage and 8 % to 90 %
for operating temperature
Maximum operation altitude
Pollution degree
2000 m (6562 ft) (unit connected to USB adapter)
3000 m (9843 ft) (unit operated from batteries)
2 (unit connected to external power supply)
3 (unit operated from batteries)
b
Overvoltage category unit: I
AC adapter: II
Measurement categoryNot rated for measurement categories II, III, or IV
Input power
c
unit: 5 VDC; 1.8 A
USB adapter: 100 - 240 Vac; 50 Hz to 60 Hz;
0.4 A Max
a. Measured in 0 °C to 31 °C (32 °F to 87.8 °F) range, decreasing linearly to 50 % at 40 °C (104 °F).
b. Equipment must be normally protected against exposure to direct sunlight, precipitation and full wind
pressure.
c. Not exceeding ± 10 % of the nominal voltage.
12FIP-400B
3Setting up Your Fiber
Inspection Probe and
ConnectorMax2 Mobile
When you receive your wireless probe, and before you start working, you
need to download the ConnectorMax2 Mobile application on your smart
device. The application is available for smart devices supporting
Android 4.2, mainly Samsung Galaxy Note 3 and 4, as well as Samsung
Galaxy Tab 4 with an 8-inch screen.
You can change various settings in ConnectorMax2 Mobile, such as the
automated file name or the way you want to share files with third party
applications. These settings are kept for future work sessions.
Preparing to Use the Mobile Application
Before you start working with your wireless probe, there are two steps to
perform.
You need to install ConnectorMax2 Mobile on your smart device.
IMPORTANT
The ConnectorMax2 Mobile application is available for free in
Google Play Store. You need to have a Google account to download
the application. For more information, refer to www.google.com.
Once the application is installed, you have to connect your wireless
probe by Wi-Fi.
When your wireless probe is connected, it is added to the list of the
available probes. It remains available for future tests.
Note: You need to have access to an external Wi-Fi network to install
ConnectorMax2 Mobile. The Wi-Fi needs to be set to ON on your smart
device.
Fiber Inspection Probe13
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Connecting or Disconnecting the Wireless Probe
To install ConnectorMax2 Mobile:
1. Ensure you have access to an Internet connection.
2. Ta p th e Google PlayStore icon.
3. In the Google Play Store (or Play Store) application, search for EXFO
or ConnectorMax2 Mobile.
4. Follow the instructions on-screen.
Once the ConnectorMax2 Mobile is installed, you can now activate the
wireless probe.
Connecting or Disconnecting the Wireless
Probe
When the ConnectorMax2 Mobile is installed on your smart device, you
have to connect your wireless probe by Wi-Fi. When your wireless probe is
connected it is added to the list of the available probes. It remains available
for future tests.
You have to disconnect the probe first if you want to perform the following:
work with another probe
use the probe with another smart device
share files with third-party applications
14FIP-400B
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Connecting or Disconnecting the Wireless Probe
To connect the wireless probe:
1. Ensure the power saving mode is disabled on your smart device.
2. Turn on the probe by pressing the ON button.
3. Ensure the Wi-Fi is activated on your smart device.
4. Start the ConnectorMax2 Mobile application.
5. Select the wireless probe you want to work with.
Note: When a wireless probe is selected, the 3G, 4G and LTE communications are
disabled automatically.
Note: The probes are identified by their serial numbers and type.
Note: The probe can be selected from the Wi-Fi configuration on the smart
device.
Fiber Inspection Probe15
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Connecting or Disconnecting the Wireless Probe
To disconnect the wireless probe:
1. From the main window, tap .
Note: Depending on the smart device you are using, the application settings can
be found in the menu button instead.
2. Select Disconnect probe.
16FIP-400B
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Changing the Fiber Inspection Probe Tip
Changing the Fiber Inspection Probe Tip
You can use various tips depending on the type of connector you are
inspecting. For more information about tips you can use, see the Fiber Inspection Probe Tip Compatibility Chart on page 85, or contact your
vendor for additional information.
To change a tip:
1. Untighten the tip’s retaining nut.
2. Remove the tip.
3. Insert a new tip.
4. Adjust the tip to the notch.
5. Retighten the retaining nut.
Fiber Inspection Probe17
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Setting up Autonaming
Setting up Autonaming
The autonaming feature is useful to make a relevant naming scheme for
your tests. This also ensures that you do not overwrite files by mistake. You
can select which item goes in the file name, as well as the type of separator
you want to use in between.
A preview is available to show you the final output of the file name.
In Live Video mode, the autonaming parameters can be set. You will only
see the parameters for the current and next capture (when the test is done
but not saved yet), or for the next capture only (test is not done yet).
Otherwise, the parameters will not be displayed.
In Capture and Archive modes, it is possible to change the name of the file
without changing the settings.
18FIP-400B
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Setting up Autonaming
To configure the automatic file naming:
1. From the main window, tap the at the end of the Identification row.
Note: You can also tap the at the end of the Measurement Name row.
Fiber Inspection Probe19
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Setting up Autonaming
2. Select the Autonaming tab.
3. Move the identifiers from the Inactive Identifiers to the Active
Identifiers space by tapping . You can remove the identifiers by
tapping . You can also move the identifiers with the drag and drop
gesture.
Note: Only the identifiers with values are displayed.
4. Under Filename Edition, you can customize the information displayed
next to Custom Filename.
Note: You can edit information either with the virtual keyboard or with the
microphone. A microphone is part of the virtual keyboard on your smart
device.
20FIP-400B
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Setting up Autonaming
5. If you want to select the separator in the automatic numbering section,
tap the line next to Separator.
5a. Navigate through the separators by scrolling through the words
that are greyed.
5b. Tap OK to confirm your choice.
6. Tap to confirm your new settings and to return to the main window.
The new settings will apply the next time you perform a capture.
Fiber Inspection Probe21
Setting up Your Fiber Inspection Probe and ConnectorMax2 Mobile
Setting up Identification
Setting up Identification
In order to have information on the tests to be performed, it is possible to
customize some fields such as the cable ID, the fiber ID, the location (A
and/or B), the Connector ID, or the Frame.
To configure the identification:
1. From the main window, tap the at the end of the Identification row.
Note: You can also tap the at the end of the Measurement Name row.