Introduction

Welcome to the Ultra 1400 Series User’s Guide, designed to help you maximize the usefulness of your new dispenser.

Please spend a few minutes to become familiar with the controls and features. Follow our recommended testing procedures. Review the helpful information we have included, which is based on more than 30 years of industrial dispensing experience.

Most questions you will have are answered in this guide. However, if you need assistance, please do not hesitate to contact EFD or your authorized EFD distributor.

n the USA, call 800-556-3484 between 8:30 a.m. and 5:30 p.m. Eastern time.

In Europe, call +44 (0) 1582 666334.

In Asia, call +86 (21) 5854 2345.

In all other areas, call your authorized EFD distributor or +1-401-434-1680.

The EFD Pledge

We pledge that you will be completely satisfied with our products. We endeavor to ensure that every EFD product is produced to our no-compromise quality standards.

If you feel that you are not receiving all the support you require, or if you have any questions or comments, I invite you to write or call me personally.

Our goal is to build not only the finest equipment and components, but also to build long-term customer relationships founded on superb quality, service, value and trust.

Peter Lambert, President

2

Contents

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11

Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Input/Output Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Vacuum Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Filling the Syringe Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Syringe Barrel Loaders. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18

Schematic / Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Helpful Hints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Productivity Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

This manual is for the express and sole use of EFD dispenser purchasers and users, and no portion of it may be reproduced in any form.

3

Safety

Introduction

Read and follow these safety instructions. Taskand equipment-specific warnings, cautions and instructions are included in equipment documentation where appropriate.

Qualified Personnel

Equipment owners are responsible for making sure that EFD equipment is installed, operated and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations, and are physically capable of performing their assigned tasks.

Intended Use

Use of EFD equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property.

Some examples of unintended use of equipment include:

Using incompatible materials

Making unauthorized modifications

Removing or bypassing safety guards or interlocks

Using incompatible or damaged parts

Using unapproved auxiliary equipment

Operating equipment in excess of maximum ratings

Regulations and Approvals

Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for EFD equipment will be voided if instructions for installation, operation and service are not followed.

Personal Safety

To prevent injury follow these instructions.

Do not operate or service equipment unless you are qualified.

Do not operate equipment unless safety guards, doors or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices.

If you receive even a slight electrical shock, shut down all electrical or equipment immediately. Do not restart the equipment until the problem has been identified and corrected.

Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer’s instructions for safe handling and use of materials, and use recommended personal protection devices.

To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits and moving parts that cannot be enclosed or otherwise guarded for practical reasons.

This equipment is for indoor use only.

Use only the power cord provided with the unit. Contact EFD to purchase a replacement cord.

Always keep dispensing end of syringe barrel pointed away from your face and towards the work piece. Store the syringe barrel in an appropriate holder when not in use.

4

Safety

Fire Safety

To avoid a fire or explosion, follow these instructions.

Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected.

Do not smoke, weld, grind or use open flames where flammable materials are being used or stored.

Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local codes or your material MSDS for guidance.

Do not disconnect live electrical circuits when working with flammable materials. Shut off power at a disconnect switch first to prevent sparking.

Know where emergency stop buttons, shutoff valves and fire extinguishers are located.

Clean, maintain, test and repair equipment according to the instructions in your equipment documentation.

Use only replacement parts that are designed for use with original equipment. Contact your EFD representative for parts information and advice.

Action in the Event of a Malfunction

If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps:

Disconnect and lock out system electrical power.

Identify the reason for the malfunction and correct it before restarting the system.

Disposal

Dispose of equipment and materials used in operation and servicing according to local and national codes.

5

Specifications

Cabinet size: 13.3 W x 15.0 H x 15.2 D cm (5.25 x 5.94 x 6.00")

Weight: 1.37 kg (3.01 lb)

Input voltage: Selectable 100/120/220 VAC

Input frequency: 50/60 Hz

Input power: 14/12 VA

Internal voltage: 24 VDC

Foot pedal voltage: 5.5 VDC

End of cycle feedback circuits: 5 to 24 VDC; 100mA maximum

Initiate circuits: Foot pedal, finger switch or 5 to 24 VDC signal

Cycle rate: Exceeds 600 cycles per minute

Time range: Programmable from .001 to 99.9 seconds

Time control: Microprocessor with 0.0005 second repeatability

Ambient operating conditions

Temperature: 5ºC to 45ºC (41ºF to 113ºF)

Humidity: 85% RH at 30ºC non-condensing

Height above sea level: 2000 meters max (6,562 feet)

Meets or exceeds CE and CSA requirements

Ultra 1400

Air input: 80 to 100 psi (5.5 to 6.9 bar) Air output: 0 to 100 psi (0 to 6.9 bar)

Ultra 1415

Air input: 80 to 100 psi (5.5 to 6.9 bar) Air output: 0 to 15 psi (0 to 1.0 bar)

Note: Specifications and technical details are subject to change without prior notification.

15.0 cm 5.94"

+

+

13.3 cm

15.2 cm

6.00"

5.25"

 

6

Getting

Started

Unpack the Unit / Warranty

1

• Unpack the unit.

 

 

• Now is a good time to activate your Two Year Warranty. Register the

 

warranty online at www.efd-inc.com/warranty/two. Or if you prefer, follow

 

the instructions in the enclosed “Welcome” letter to contact your EFD

 

representative.

Install Barrel Holder

2

• Remove sleeve from barrel holder.

 

• Insert 6 mm screw through wire adapter

 

hose holder, then through barrel holder .

 

• Tighten screw to secure holder to

 

dispenser cover. Holder can be mounted

left or right.

Insert barrel holder sleeve.

Note: If you prefer, the wire adapter hose holder can be mounted on the opposite side of the cabinet, separately from the barrel holder.

Connect Air Input

Note: Clean, dry filtered factory air is required to meet 3 warranty. If your air supply is not filtered, order the EFD

five micron filter regulator (EFD part #2000F755).

Turn air pressure regulator knob to zero before connecting main air input to the Ultra 1400.

Push one end of the 6 mm air input hose into the input fitting on the back of the Ultra 1400.

Connect the other end of the hose to your plant air supply.

A standard 1/4-inch NPT fitting is included with your dispenser.

Set plant air supply at minimum 80 to 100 psi (5.5 to 6.9 bar).

air input

7

Getting

Started

Set Voltage / Connect Power

4

• Check the voltage label to be certain it is set to the available power.

The Ultra 1400 is shipped with the fuse cartridge set for 120 VAC input.

• To change the voltage, remove the voltage selector from the cartridge,

rotate it and position the correct voltage to show through the cartridge

window. Replace the cartridge into the power cord receptacle, making

sure that both sides snap securely into position.

Connect the power cord into the back of the Ultra 1400.

Connect the power cord into your local power source.

Press the power switch on the back panel.

Connect Foot Pedal

spare fuse

voltage value

cartridge window

• The Ultra 1400 Series is normally

 

operated using the foot pedal provided.

Connect the foot pedal to the back of the

5

Ultra 1400.

If you prefer, you can also operate the

Ultra 1400 with an optional finger switch.

Specify EFD part #2015FS.

foot pedal connector

Attach Syringe Barrel / Dispense Tip

6

Attach an EFD syringe barrel filled with your fluid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the adapter assembly.

 

 

 

 

 

 

 

Snap the safety clip on the adapter hose closed to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prevent dripping. Remember to unsnap the clip

 

 

 

 

 

 

 

 

when ready to dispense.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Replace tip cap with an EFD precision dispense tip.

• Place syringe barrel in the barrel holder.

8

Loading...