Denon AVR-3300 Service Bulletin

100 Corporate Drive Mahwah, NJ 07430
Service Bulletin
No. : OST-620 Date:
January 23, 2007
_____________________________________________________________
Model: AVR-3300
Symptom: The customer complains the cooling fan is too noisy. The noise
level increases at a high-speed rotation due to the metal-bearings on the Fan. Also, the noise will increase when the Fan is driven at a high-speed.
Solution:
fan.
The Metal bearing fan has been replaced with the Ball Bearing type
Parts:
Ref# Description Part Number
ZD901 MTZJ12A 2760644 966
FAN FAN (80*80) 24V (H) 421 0769 001
Serial Number:
The modification differs depending on the production date of the unit as outlined below:
1) For units that were produced in April 2000 and the before. (Serial Number 004**** and before): Replace the Cooling Fan only.
2) The units that were produced in May 2000 and the after. (Serial Number005**** and after):
Note: The JV23 Wire on the 1U-2301-1, Regulator Unit has been replaced with a 82 resistor for reducing the rotation speed.•••• Replace the JV23, 82 resistor with a Jumper Wire and replace the Fan with the new one.
______________________________________________________________________________________
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.
CONFIDENTIALITY NOTICE:
3) For the units whose ZD901, MTZJ12A has been temporarily replaced with a MTZJ9.1C for the countermeasure. Replace the ZD901, MTZJ9.1C with the original MTZJ12A, and replace the Fan with the improved style.
4) The units to which the modification for thermal protector has been applied Note: The TR921, 2SD1763A has been cut off, and Jumpers JV52 and JV53 have been connected and short circuited by means of a wire so that the Fan rotates at a high speed regardless of the signal level. For these units, replace the Fan with the improved one.
______________________________________________________________________________________
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.