OWNER’S USE AND CARE GUIDE
GUIDE D’UTILISATION ET SOINS DE
PROPRIÈTAIRE
PORTABLE AIR CONDITIONER
CLIMATISEUR PORTATIF
MODEL MODÈLE DPA120B3WDB
-ODELs-ODÕLEs-ODELO
Danby Products Limited, Ontario, Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio, USA 45840
08.01.14
TO OBTAIN WARRANTY SERVICE YOU MUST PROVIDE A VALID PROOF OF
PURCHASE. PLEASE STAPLE YOUR RECEIPT TO THIS PAGE FOR FUTURE
REFERENCE.
------------------------------------------------------------------------------------------------------------------POUR OBTENIR LE SERVICE SUR GARANTIE VOUS DEVEZ FOURNIR UNE
PREUVE D’ACHAT VALIDE. VEUILLEZ AGRAFER VOTRE REÇU À CETTE PAGE
POUR RÉFÉRENCE FUTURE.
This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must
be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and
applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the
responsibility and obligation of the customer to exchange the existing receptacle in accordance with the
National Electrical Code and applicable local codes and ordinances. The third ground prong should not,
under any circumstances, be cut or removed. Never use the cord, the plug or the appliance when they show
any sign of damage. Do not use your appliance with an extension cord unless it has been checked and tested by a qualifi ed electrician or electrical supplier.
IMPORTANT - MÉTHODE POUR LA MISE À LA TERRE
Ce produit arrive d’origine avec un cordon d’alimentation équipé d’une prise à trois fi ches. Il doit être
branché dans une prise avec une fi che de mise à la terre en conformité avec le Code National de l’Électricité
et les codes et règles locales applicables. Si le prise murale n’a pas de mise à la de terre, il est de la
responsabilité et l’obligation du client de changer la prise existante pour la rendre conforme aux Codes
Nationaux de l’Électricité, aux codes et règles locaux applicables. La fi che de la mise à la terre ne doit pas,
en aucune circonstance, être coupée ou retirée. Si vous apercevez des signes de dommage, n’utilisez jamais
le cordon d’alimentation, la prise ou l’appareil. N’utilisez jamais l’appareil avec une rallonge sauf si elle a été
vérifi ée et testée par un électricien qualifi é ou un fournisseur de matériel électrique.
Contents
PORTABLE AIR CONDITIONER
Owner’s Use and Care Guide
Read and follow all safety rules and
operating instructions before first use of this
product.
PRECAUTION:
Veuillez lire attentivement les consignes de
sécurité et les instructions d’utilisation avant
l’utilisation initiale de ce produit.
Model Modèle DPA120B3WDB
1
Welcome
Welcome to the Danby family. We are proud of our quality products, and we believe in dependable service, like you will
¿ nd in this Owner’s Use and Care Guide, and like you will receive from our friendly customer service department. Best of
all, you will experience these values each and every time you use your Danby appliance. That is important, because your
new appliance will be a part of your family for a long time.
Note the information below; you will need this information to obtain service under warranty.
To receive service, you must provide the original receipt.
Model No:
Serial No:
Date Purchased:
NEED HELP?
Before you call for service, here are a few things you can do to
help us serve you better:
Read this Owner’s Use and Care Guide:
It contains instructions to help you use and maintain your
appliance properly.
If you received a damaged appliance:
Immediately contact the retailer (or builder) that sold you the
appliance.
Save time and money:
Check the Troubleshooting section at the end of the guide
before calling. This section helps you solve common problems
that may occur.
If you do need service, you can relax, knowing help is only a
phone call away.
WARNING
Tel: 1-800-26-
(1-800-263-2629)
Improper connection of the grounding plug can result in risk of
¿ re, electric shock and/or injury to persons associated with the
appliance. Check with a quali¿ ed service representative if in doubt
that the appliance is properly grounded.
2
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation resulting from to ignoring these instructions may cause harm or damage.
SAFETY
PRECAUTIONS
ALWAYS DO THIS
Your air conditioner should be used in such a way that it is protected
from moisture. e.g. condensation, splashed water, etc. Do not place or
store your air conditioner where it can fall or be pulled into water or
any other liquid. Unplug unit immediately if this occurs.
Always transport your air conditioner in a vertical position and place
on a stable, level surface during use. If the unit is transported laying
on it’s side it should be stood up and left unplugged for 4 hrs.
Turn off the unit when not in use.
Always contact a qualified person to perform repairs. If the power cord
is damaged it must be repaired by a qualified technician.
Keep clearance of at least 30cm (1 foot) all around the unit from walls,
furniture and curtains, to allow for adequate air flow.
If the air conditioner is knocked over during use, turn off the unit and
unplug it immediately.
Always use the switch on the control panel to turn the unit on or off.
Portable air conditioners exhaust large amounts of room air. Always
ensure an adequate supply of make-up air to operate efficiently.
NEVER DO THIS
Do not operate your air conditioner in a wet room such as a bathroom
or laundry room.
Do not touch the unit with wet or damp hands.
Do not press the buttons on the control panel with anything other than
your fingers.
Do not remove any fixed components. Never use this appliance if it is
not working properly, or if it has been dropped or damaged.
Never use the plug to start and stop the unit.
Do not cover or obstruct the inlet or outlet grilles.
Do not use hazardous chemicals to clean or come into contact with
the unit. Do not use the unit in the presence of inflammable
substances or vapour such as alcohol, insecticides, petrol,etc.
Do not allow children to operate the unit unsupervised.
Do not use this product for functions other than those described in this
instruction manual.
3
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation resulting from to ignoring these instructions may cause harm or damage.
ENERGY SAVING
TIPS
OPERATING
CONDITION
TOOLS FOR WINDOW
KIT INSTALLATION
Use the unit in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out
(cooling mode).
The air conditioner must be operated within the temperature range
indicated below:
MODE
COOL
DRY
*HEAT (heat pump type)
*HEAT (electrical or heat pump)
(*) Optional feature, some models may not have this feature.
Note: Performance may be reduced outside of these operating
temperatures.
1. Screwdriver (medium size, Phillips)
2. Tape measure or ruler
3. Knife or scissors
4. Saw (In the event that the window kit needs to be cut down in size
because the window is too narrow for direct installation).
See www.danby.com for general instruction guide.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord
or an adaptor plug. Do not remove any prong from the power
cord.
WARNING
Be sure the electrical supply is adequate for the model you have
chosen. This information can be found on the serial plate, which
is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The
power cord is equipped with a three-prong grounding plug for
protection against shock hazards.
Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or circuit
breaker, have a qualified electrician install the proper receptacle.
Ensure the receptacle remains accessible after the unit is
installed.
4
Identifying Parts
ACCESSORIES
PARTS
PART NAME
Exhaust hose and adaptor
B (round mouth); Window
QUANTITY
1 set
slider kit and screws
Foam seal
A
C
D
H
U
O
R
E
T
O
A
Y
L
T
O
I
O
IWS
N
EDOM
N
G
F
O
L
M
RESE
L
E
O
ET
O
M
W
N
P
T
/
L
OC
D
I
YMONOCE
L
FFO
S
K
E
P
D
L
A
F
Y
A
T
N
I
M
F
H
M
S
I
E
OL
P
REMIT
NA
G
D
E
W
BRUT
H
E
O
O
FORE
D
N
F
Remote Controller and
Battery (For remote control
models only)
Drain hose
6/pc
1set
1pc
NOTE:
Check all the accessories are included in the package and please refer to the installation
instructions for their usage.
NOTE: All the illustrations in this manual are for explanation purpose only. Your air conditioner
may be slightly different.
UNIT STRUCTURE
Fig.1
FRONT
5
1
Control Panel
Horizontal louver blade
2
(adjusts automatically)
Caster
3
Carrying handle
4
(both sides)
Identifying Parts
REAR
Upper air filter (Behind the grille)
5
Fig.2
Features
ELECTRONIC CONTROL
INSTRUCTIONS
Upper air intake
6
7
Air outlet
8
Drain outlet (only for pump heating model)
9
Power cord outlet
Power cord buckle (used only when storing
10
the unit)
11
Bottom tray drain outlet
Power plug socket (use only when storing
12
the unit)
Lower air filter (behind the grill)
13
14
Lower air intake
15
Drain outlet
Before you begin, thoroughly familiarize yourself with the control panel
and remote controller and all its functions, then use the icons to change
the functions you desire.
Fig.3
The unit can be controlled by the unit control panel alone or with the
remote controller .
NOTE: This manual does not include Remote Controller Operations, see
the <<Remote Controller Instructions>> packed with the unit for details.
6
Features
ELECTRONIC CONTROL
INSTRUCTIONS
POWER button
1
Turns power on/off.
2
SLEEP button
Used to initiate the SLEEP operation.
3
FAN button
Controls the fan speed. Press to toggle between three fan speeds: LOW
(press 1 time), MEDIUM (press 2 times) and HIGH (press 3 times). The
fan speed indicator light indicates the corresponding fan setting. Press the
button a fourth time to initiate AUTO-FAN mode. In this mode, all three
indicator lights will light up.
4
Used to adjust (increase /decrease) temperature settings (1°C/2°F
increments) in a range of 17°C(62°F) to 30°C(86°F) or the TIMER setting in a range of 0~24hrs. The control is capable of displaying
temperature in degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and Down buttons at the
same time for 3 seconds.
MODE select button
5
Selects the appropriate operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL,
DRY, FAN and HEAT(select models only). The mode indicator light
illuminates depending on the mode settings.
TIMER button
6
Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the UP and DOWN buttons.
SWING button
7
Used to initiate the Auto swing feature. When
SWING button to stop the louver at the desired angle.
8
LED DISPLAY
Shows the set temperature in °C or °F and the Auto-timer settings.
While on DRY and FAN modes, it shows the room temperature.
UP and DOWN buttons
operating press the
Error codes:
E1 - Room temperature sensor error-Unplug the unit and plug
it back in. If error repeats, call for service.
E2 - Evaporator temperature sensor error- Unplug the unit and
plug it back in. If error repeats, call for service.
E3 - Condenser temperature error - Unplug the unit and plug it
back in. If error repeats call for service.
E4 - Display panel communication error - Unplug the unit and
plug it back in. If error repeats call for service.
P1 - Bottom tray is full - Connect the drain hose and drain the
collected water away. If error repeats, call for service.
7
Operating Instructions
ELECTRONIC CONTROL
INSTRUCTIONS (con’t)
OPERATING MODES
COOL mode
- Press the "MODE" button until the "COOL" indicator light comes on.
- Press the ADJUST buttons "up + " or "down - " to select your desired
room temperature. The temperature can be set within a range of
17°C-30°C / 62°F-86°F.
- Press the "FAN SPEED" button to choose the fan speed.
HEAT mode (select models only)
- Press the "MODE" button until the "HEAT" indicator light comes on.
- Press the ADJUST buttons "up +" or "down -" to select your desired
room temperature. The temperature can be set within a range of
17°C-30°C / 62°F-86°F.
- Press the "FAN SPEED" button to choose the fan speed. For some
models, the fan speed can not be adjusted under HEAT mode.
AUTO mode
- When you set the air conditioner in AUTO mode, it will automatically
select cooling, heating (select models only) or fan only operation
depending on what temperature you have selected and the room
temperature.
- The air conditioner will adjust the room temperature automatically to
the temperature point set by you.
- Under AUTO mode, you can not select the fan speed.
FAN operation
- Press the "MODE" button until the "FAN” indicator light comes on.
- Press the "FAN SPEED" button to choose the fan speed (1 time for LOW,
2 times for MEDIUM, 3 times for HIGH, 4 times for AUTO-FAN).
- The corresponding fan speed indicator light for each speed lights up. All
three indicators are lit up when AUTO-FAN is selected.
- The temperature cannot be adjusted.
- Do not use the window hose in this mode.
TIMER operation
- To initiate the “Auto-stop” program: When the unit is on, press the Timer
button, the TIMER OFFindicator light will illuminate.
- To initiate the “Auto-start” program: When the unit is off, press the Timer
button, the TIMER ON indicator light will illuminate.
- Press or hold the “UP ” or “DOWN ” button to change the Auto time by
0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24
hours.The control will count down the time remaining until the unit starts.
- The selected time will register in 5 seconds and the system will
automatically revert back to display the previous temperature setting.
- Turning the unit ON or OFF at any time or adjusting the timer setting
to 0.0 will cancel the Auto Start/Stop timed program.
- When a malfunction (E1, E2, E3, E4, or P1) occurs, the Auto Start/Stop
timed program will also be cancelled.
8
Operating Instructions
OPERATING MODES
(con’t)
POWER OUTAGE
AIR FLOW DIRECTION
ADJUSTMENT
SLEEP cycle
This unit features an operation mode that is designed to keep you
comfortable while sleeping, and save you money on your energy bill.
Simply press the sleep button. Depending on whether the unit is in heating or cooling mode, the temperature will either increase (cooling mode)
or decrease (heating mode) by 1°C / 2°F every half hour for 1 hour. It will
then hold this new temperature for 7 hours before returning to the original
temperature setting and resuming normal operation.
NOTE: This feature is unavailable in FAN and DRY mode.
In case of a power outage or interruption, the unit will automatically restart in the default settings after the power is restored.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not operate for 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
Adjust the air flow direction automatically (Fig. 4):
- The louver can be adjusted automatically, to change the airflow
direction. (Fig.4)
- When the power is ON, the louver opens fully.
- Press the SWING button on the panel or remote controller to initiate the
Auto swing feature.
- The louver willl swing up and down automatically.
Please do not adjust the louver manually.
Swing automatically
Fig.4
9
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.