▪ Read the documentation carefully before operating the user
interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used
to configure your system. Check if he has filled in the installer
settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Target audience
Endusers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before operating your
system
▪ Format: Paper (in the box of the outdoor unit)
Operation manual
2
2About the system
Depending on the system layout, the system can:
▪ Cool down a space
▪ Heat up a space (if a heating/cooling heat pump model is
installed)
2.1Components in a typical system
layout
A Living room.
B Bedroom.
C Main LWT zone with multiple rooms (A and B).
D Technical room. Example: Garage.
a Outdoor unit heatpump
b Control box EKCB07CAV3
c Fan coil units
d User interface connected to the control box
e User interface in the living room, used as room thermostat
f Underfloor heating
g Option box EK2CB07CAV3
EWAQ+EWYQ004+005BAVP
Packaged air-cooled water chillers and packaged air to water heat
pumps
4P469108-1 – 2017.01
3 Operation
a
ef
b
d
c
3Operation
3.1Overview: Operation
You can operate the system via the user interface. This part
describes how to use the user interface:
PartDescription
At a glance▪ Buttons
▪ Status icons
Space heating/cooling
control
SchedulesHow to select and program schedules
Menu structureOverview of menu structure
Installer settings tableOverview of installer settings
3.2The user interface at a glance
3.2.1Buttons
a
HOME PAGES
▪ Switches between home pages (when you are on a home
page).
▪ Goes to the default home page (when you are in the menu
structure).
b
MALFUNCTION INFORMATION
If a malfunction occurs,
Press to display more information about the malfunction.
c
ON/OFF
Turns ON or OFF one of the controls (room temperature,
leaving water temperature).
d
MENU STRUCTURE/BACK
▪ Opens the menu structure (when you are on a home
page).
▪ Goes up a level (when you are navigating through the
menu structure).
▪ Goes back 1step (example: when you are programming a
schedule in the menu structure).
e
NAVIGATING/CHANGING SETTINGS
▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.
f
OK
How to control space heating/cooling:
▪ Setting the space operation mode
▪ Controlling the temperature
is displayed on the home pages.
▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or
between displaying actual and offset values (if applicable)
on the home pages.
▪ Goes to the next step (when you are programming a
schedule in the menu structure).
INFORMATION
If you press or while changing settings, the changes
will NOT be applied.
3.2.2Status icons
IconDescription
Space operation mode = Heating.
Space operation mode = Cooling.
Unit is operating.
Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
On the room temperature home page: Desired room
temperature = according to the selected schedule.
Actual temperature.
Desired temperature.
At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Button lock mode and/or function lock mode is active.
An external heat source is active. Example: Gas
burner.
A malfunction occurred. Press to display more
information about the malfunction.
Weather-dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
3.3Space heating/cooling control
3.3.1Setting the space operation mode
About space operation modes
Depending on your heat pump model, you have to tell the system
which space operation mode to use: heating or cooling.
If a… heatpump model
is installed
Heating/coolingThe system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
Then…
EWAQ+EWYQ004+005BAVP
Packaged air-cooled water chillers and packaged air to water heat
pumps
4P469108-1 – 2017.01
Operation manual
3
3 Operation
15:20
20.0°C
Mon
Room
Actual temperature
15:20
20.0°C
17:30
Actual temperature
Room
Scheduled
Mon
Tue
20.0°C
Actual temperature
22.0°C
Desired temperature
If a… heatpump model
Cooling onlyThe system can cool down a space, but
To tell the system which space operation to use, you can do the
following:
Check which space operation mode is
currently used.
Set the space operation mode.Menu structure
Restrict when automatic changeover is
possible.
To set the space operation mode
1 Go to [4]: > Operation mode.
2 Select one of the following options and press :
To restrict automatic changeover operation mode
Prerequisite: You switched the permission level to Advanced end
user.
Prerequisite: You switched the space operation mode to automatic.
1 Go to [7.5]: > User settings > Allowed operation mode.
2 Select a month and press .
3 Select Heating only, Cooling only or Heating/Cooling, and press
3.3.2Room thermostat control - Using the
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To set the user profile, refer to
Configuring user profile and home pages in the user reference
guide.
To read out the actual and desired room
temperature
1 Go to the room temperature home page (Room).
Operation manual
4
Then…
is installed
NOT heat up a space. You do NOT have
to tell the system which space operation
mode to use.
You can…Location
Home pages:
▪ Room temperature
▪ Leaving water
temperature (main)
If you select…Then the space operation mode is…
HeatingAlways heating mode.
CoolingAlways cooling mode.
AutomaticAutomatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
taking monthly restrictions into
account.
Note: Automatic changeover is only
possible under certain conditions.
.
room temperature home page
User profile = BasicUser profile = Detailed
Result: You can read out the actual temperature.
2 Press .
Result: You can read out the desired temperature.
To temporarily overrule the room temperature
schedule
1 Go to the room temperature home page (Room).
2 Use or to adjust the temperature.
To change the mode from scheduled to preset
value
Prerequisite: User profile = Detailed.
1 Go to the room temperature home page (Room).
2 Press or to select a preset value ( or ).
Result: The mode will return to Scheduled according to the overrule
period.
To set the overrule period
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.2]: > User settings > Temperature lock.
2 Select a value and press :
▪ Permanent
▪ hours (2, 4, 6, 8)
3.3.3Room thermostat control - Using the
leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water temperature than radiators and/or fan coil units. You
only have to adjust leaving water temperature settings in
case of problems.
For more information about the leaving water temperature, see the
user reference guide.
3.4Advanced usage
3.4.1About changing the user permission level
The amount of information you can read out in the menu structure
depends on your user permission level:
▪ End user (= default)
▪ Adv. end user: You can read out more information.
To set the user permission level to Advanced end user
1 Go to the main menu or any of its submenus: .
2 Press for more than 4seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set
otherwise.
To set the user permission level to End user
1 Press for more than 4 seconds.
Packaged air-cooled water chillers and packaged air to water heat
EWAQ+EWYQ004+005BAVP
4P469108-1 – 2017.01
pumps
Loading...