CEMB USA TA18S User Manual

Page 1
Acceleration transducer mod. TA18S
FUNCTIONING
The TA18S transducer picks up seismically the absolute vibrations of the machine by being fitted directly to the supports of the vibrating part; it supplies an output signal directly proportional to the vibration of the point to which it is fastened. Such signal should subsequently be processed by one of the measuring channel of a CEMB serial “T” or “N” processing unit.
TECHNICAL CHARACTERISTICS
Type of measurement : seismic (absolute vibrations) Dynamic range : ± 50 g Frequency response : ± 3 dB 0,5 ÷ 15000 Hz
± 10 % 0,8 ÷ 6000 Hz
± 5 % 1 ÷ 4000 Hz Direction of vibrations : any Sensitivity : 100 mV/g Tranverse sensitivity : < 5 % Reasonance frequency : 25 kHz Protection against shocks : 5000 g pk Power supply : 2÷20 mA - 18÷28 Vdc Outlet impedance : < 150 ohm Temperature range : -54°C ÷ +121°C External casing material : stainless steel AISI 316-L Mounting screws : standard = ¼”-28UNF-2B or
to be specified along with the order among those shown on dwg 58608-P Weight : 88 g Protection against external : IP65 EN60529/10.91 Connection : 2 pin connector MIL-C-5015 serie 3106/10, supplied as standard
ASSEMBLY
Make a threaded hole on the support to be tested. The surface where the transducer rests must be perfectly smooth and flat. Is is advised to provide a film of silicon between the resting surface and the sensor.
NOTE : avoid hitting violently the transducer housing, the closure couple must be 2,7÷6,8 Nm. MAINTENANCE
Any.
DIMENSIONS, FIXTURE AND CONNECTIONS
As per enclosed dwg. n° 58608-P.
Page 2
CEMB Spa
ASTD45120
Cemb UTS 100312