Service Bulletin
Issued by Canon Europa N.V.
COPIER
Model:
Location:
Subject:
Reason:
Detail:
iR1210/iR1230 iR1270F
Installation Procedure
Countermeasure against light image after installation
To notify the countermeasure against light image at an early stage after the installation.
<Symptom>
Light image may occur at an early stage after the machine installation or the developing unit
replacement.
<Cause>
This symptom occurs by the low toner tribo rate when toner is replenished into the new developing
unit. Therefore, densi ty is re covered by making dozens of c opies.
No.:
DATE:
iR1200S-007
(FF-T01-L6-000061-01)
20.12.02
Service Work :
Follow the steps below in order to recove r density with the minimum copy count.
c As mentioned at “13. Checking the Copy Images” in Installation Procedure, carry out Mix
Toner mode once, and make a copy with the NA-3 (test chart) to check the image. If density
recovery is necessary at this time, perform the following.
d Carry out Mix Toner mode twice, and make a copy with the NA-3(test chart) to check the image.
[CAUTION]
If you continuously carry out Mix Toner mode more than 3times, the blade may be curled.
Do not continue the mode more than 3 times.
e Repeat d until density is recovered.
As a guide, density is recovered after performing d a pprox. 10 ∼ 20 times.
In addition, light image may o ccur if user does not operate the machine for a long time.
However, above-mentioned measure is also effective for this case, so repeat the operation, “Mix Toner
mode×2, NA- 3 copy×1” a few times.
- 1 / 1 -