Safety4
About this Manual4
Legal Information4
Safety Precautions5
Important Safety Instructions6
Customer Support and Service8
Unpacking9
Parts List9
Parts List9
Additional Parts Required9
Tools Required10
Additional Parts Recommended But Not Required11
System overview12
Installation (Indoor models)13
Installation (Outdoor model)15
Installation overview15
Connect the midspan to ground16
Install the midspan directly to a wall17
Install the midspan to a pole mount adapter19
Connect the AC cable24
Connect the RJ45 cable25
Connection26
Troubleshooting29
Disposal33
Bosch Security Systems2020-11 | 1.0 |
4en | SafetyPoE midspans for PTZ cameras
1Safety
1.1About this Manual
This manual has been compiled with great care and the
information it contains has been thoroughly verified. The text
was complete and correct at the time of printing. Because of the
ongoing development of products, the content of the manual
may change without notice. Bosch Security Systems accepts no
liability for damage resulting directly or indirectly from faults,
incompleteness, or discrepancies between the manual and the
product described.
1.2Legal Information
Copyright
This manual is the intellectual property of Bosch Security
Systems, and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document
are likely to be registered trademarks and must be treated
accordingly.
2020-11 | 1.0 |Bosch Security Systems
PoE midspans for PTZ camerasSafety | en5
!
!
i
1.3Safety Precautions
In this manual, the following symbols and notations are used to
draw attention to special situations:
Danger!
High risk: This symbol indicates an imminently hazardous
situation such as “Dangerous Voltage” inside the product. If not
avoided, this will result in an electrical shock, serious bodily
injury, or death.
Warning!
Medium risk: Indicates a potentially hazardous situation. If not
avoided, this may result in minor or moderate injury.
Caution!
Low risk: Indicates a potentially hazardous situation. If not
avoided, this may result in property damage or risk of damage
to the unit.
Notice!
This symbol indicates information or a company policy that
relates directly or indirectly to the safety of personnel or
protection of property.
Bosch Security Systems2020-11 | 1.0 |
6en | SafetyPoE midspans for PTZ cameras
1.4Important Safety Instructions
Important safety information
–The unit should be connected to PoE networks only,
without routing to the outside plant.
–Only qualified personnel can install or remove the unit.
–Follow basic electricity safety measures whenever
connecting the unit to its power source.
–A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
unit to this power outlet.
–Read the installation instructions before connecting the
unit to its power source.
EMC compliance
–FCC Part 15 class B and EN 55022 class B
–EN55024
–VCCI
Safety compliance
–UL/cUL per 60950-1
–GS mark
–Installation and removal of the midspan must be carried out
by qualified personnel only.
–Follow basic electricity safety measures whenever
connecting the midspan to its power source.
–A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
midspan to this power outlet.
–The PoE injector "Data In" and "Data & Power Out" ports
are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets.
Only RJ45 data connectors can be connected to these
sockets.
2020-11 | 1.0 |Bosch Security Systems
PoE midspans for PTZ camerasSafety | en7
–The Data In and Data & Power Out interfaces are qualified
as SELV (Safety Extra-Low Voltage) circuits according to
IEC 60950-1. These interfaces can only be connected to
SELV interfaces on other equipment.
–This product is not intended to become a permanent part
of the building structure.
–Do not attach the power supply cord to the building
surface.
–Do not run the power supply cord through walls, ceilings,
floors, or similar openings in the building structure.
–Take appropriate measures to prevent physical damage to
the power supply cord, including proper routing.
–This device is not suitable for installation in corrosive
environments with salt water. Installers must make sure
that the installation location does not expose the device
housing directly to salt water.
–This device is not suitable for installation or operation in an
environment with SO₂.
For more information, refer to the installation manual, available
at http://www.boschsecurity.com/catalog_overview.htm
Bosch Security Systems2020-11 | 1.0 |
8en | SafetyPoE midspans for PTZ cameras
1.5Customer Support and Service
If this unit needs service, contact the nearest Bosch Security
Systems Service Center for authorization to return and shipping
instructions.
USA and Canada
Telephone: 800-289-0096, option 5
Fax: 800-366-1329
Email: repair@us.bosch.com
Telephone: 800-289-0096, option 4
Fax: 800-315-0470
Email: technical.support@us.bosch.com
Europe, Middle East, Africa, and Asia Pacific Regions
Please contact your local distributor or Bosch sales office. Use
this link:
https://www.boschsecurity.com/corporate/where-to-buy/
index.html
More Information
For more information, please contact the nearest Bosch Security
Systems location or visit www.boschsecurity.com.
2020-11 | 1.0 |Bosch Security Systems
PoE midspans for PTZ camerasUnpacking | en9
2Unpacking
2.1Parts List
The package containing the midspan should include the
following items:
QuantityComponent
160W midspan
1120 V power cord
1230 V power cord
1Quick installation guide
QuantityComponent
1High PoE Midspan 95 W, indoor model
1120 VAC power plug
1230 VAC power plug
1Quick Installation Guide
Quantity Component
1High PoE Midspan 95 W, outdoor model
1120 -240 VAC power plug
2Waterproof cap covers for male RJ45 port plugs
1Quick Installation Guide
2.2Parts List
2.3Additional Parts Required
The following table lists additional parts (not supplied by
Bosch) required to install the midspan:
Bosch Security Systems2020-11 | 1.0 |
10en | UnpackingPoE midspans for PTZ cameras
QuantityPartSizeNotes
2Mounting
screws;
Select either
size
(but not both).
2CAT5 cablesNot to exceed
QuantityPartSizeNotes
4Mounting
screws
2CAT5 cablesNot to exceed
Head diameter:
5.8 mm
(0.23 in.)
Head diameter:
7 mm
(0.27 in.)
Head height:
2 mm
(0.08 in.)
100 m (333 ft)
each
100 m (333 ft)
each
1.5 mm (0.059 in.)
clearance from mounting
surface
2.5 mm (0.098 in.)
clearance from mounting
surface
1 cable to connect to the
“Data & Power Out“
port.
1 cable to connect to the
“Data In” port.
1 cable to connect to the
“Data & Power Out“
port.
1 cable to connect to the
“Data In” port.
2RJ45
connectors,
male
2.4Tools Required
Screwdriver
2020-11 | 1.0 |Bosch Security Systems
PoE midspans for PTZ camerasUnpacking | en11
2.5Additional Parts Recommended But Not
Required
The following table lists additional parts (not supplied by
Bosch) recommended to install the midspan:
Quantity Part
1Surge suppressor
1Splitter
1Universal Power Supply (UPS)
Bosch Security Systems2020-11 | 1.0 |