Bosch D7212GV3K1, DS151I Quick Selection Guide

Intrusion Detectors
Quick Guide
June 2015
Security you can rely on
With decades of experience and an unwavering dedication to high-quality and high-performing products, Bosch detectors provide best-in-class false alarm immunity and catch performance while minimizing false alarms.
Ideal for any application
Intelligent intrusion detection is a delicate balance between responding to real security breachers and ignoring costly false alarm sources. Bosch offers a choice of detector models that set the standard for reliability and rapid detection.
Our intrusion detectors suit the requirements of virtually any application—from larger warehouses to long corridors and high ceilings. They stand up to multiple challenges, including strong drafts, moving objects and the presence of pets.
2
Residential and Small Commercial
Blue Line Gen 2 Series
PIR TriTech® (PIR+MW)
Standard Pet Friendly® Quad Standard Pet Friendly®
Commercial Type Number
Overview Application risk level Low to moderate risk Low to moderate risk Moderate risk Low to Moderate risk Low to Moderate risk Low to Moderate risk
Environment * Standard Standard Difficult Difficult Difficult Difficult
Specifications Optics 77 Zone Fresnel 77 Zone Fresnel 77 Zone Fresnel 77 Zone Fresnel 77 Zone Fresnel 77 Zone Fresnel
Coverage/range 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 20 x 20 ft (6 x 6 m) Mounting height 7 to 9 ft (2.2 to 2.75 m) 7 to 9 ft (2.2 to 2.75 m) 7 to 9 ft (2.2 to 2.75 m) 7 to 9 ft (2.2 to 2.75 m) 7 to 9 ft (2.2 to 2.75 m) 7 to 9 ft (2.2 to 2.75 m) Operating temperature **
Operating voltage Current draw (typical)
Features First step processing
Microwave noise adaptive processing Dynamic temperature compensation Wall-to-wall coverage Look-down zone Pet/small animal immunity Alarm output/memory Anti-mask Tamper Sealed optical chamber
Ease of installation *** Enable/disable LED
Enable/disable pet immunity Enable/disable look-down Microwave Doppler range adjustment Remote walk test Remote self test
Certifications AFNOR, CCC, CE,
ISC–BPR2–W12 ISC–BPR2–WP12 ISC–BPQ2–W12 ISC–BDL2–W12x ISC–BDL2–WP12x ISC–BDL2–WP6x
–20° to 130°F
(–29° to 55°C)
9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC
10 mA 10 mA 10 mA 10 mA 10 mA 10 mA
∎ – ∎ ∎ ∎ ∎ ∎ ∎
10 lb (4.5 kg) 45 lb (20 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 100 lb (45 kg) 100 lb (45 kg)
–/– –/– –/– –/– –/– –/–
– ∎ ∎ ∎ ∎ ∎ ∎ – ∎ ∎ – – ∎ – – –
EN50131–2–2 Grade 2,
INCERT, UL
–20° to 130°F
(–29° to 55°C)
AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
INCERT, UL
–20° to 130°F
(–29° to 55°C)
AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
INCERT, UL
–20° to 130°F
(–29° to 55°C)
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
IC, INCERT, UL
–20° to 130°F
(–29° to 55°C)
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
IC, INCERT, UL
–20° to 130°F
(–29° to 55°C)
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
IC, INCERT, UL
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.) ** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use. *** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
Available Not available
3
Small to Medium Commercial
Commercial Series
TriTech® (PIR+MW)
Standard Anti-mask
New
New
Commercial Type Number
Overview Application risk level Moderate risk High risk
Specifications Optics 27 Zone 27 Zone
Features Sensor data fusion
Ease of installation *** Enable/disable look-down
Certifications
Environment * Difficult Difficult
Coverage/range
Mounting height 7.5 to 9 ft
Operating temperature **
Operating voltage Current draw (typical)
Microwave noise adaptive processing Range adaptive radar Active white light suppression Dynamic temperature compensation Look-down zone Pet/small animal immunity Alarm output/memory Anti-mask Tamper Sealed optical chamber
Switchable coverage patterns Microwave Doppler range adjustment Remote walk test Remote self test
AFNOR, CCC, CE, EN50131–2–4 Grade 2, FCC, IC, INCERT, UL, VdS AFNOR, CCC, CE, EN50131–2–4 Grade 3, FCC, IC, INCERT, UL, VdS
ISC–CDL1–W15x ISC–CDL1–WA15x
50 x 50 ft
(15 x 15 m)
(2.3 to 2.75 m)
–20° to 130°F
(–30° to 55°C)
9–15 VDC 9–15 VDC
10 mA 10 mA
– ∎ ∎ – – – – ∎ ∎ ∎
10 lb (4.5 kg) 10 lb (4.5 kg)
∎/∎ ∎/∎
∎ ∎ ∎ ∎ ∎ ∎ ∎ – – ∎ ∎ – – –
50 x 50 ft
(15 x 15 m)
7.5 to 9 ft
(2.2 to 2.75 m)
–20° to 130°F
(–29° to 55°C)
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.) ** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use. *** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
Available Not available
4
Loading...
+ 8 hidden pages