Bosch D7212GV3 Specsheet

Intrusion Alarm Systems | D7212GV3 Control Panel
D7212GV3 Control Panel
www.boschsecurity.com
u Fully integrated intrusion and fire functions allow
users to interface with one system instead of two
u Conettix IP‑based communication options provide
The D7212GV3 Control Panel delivers a powerful new solution for intrusion (commercial and residential) and residential fire alarm system applications. Monitor alarm points for intruder or fire alarms while operating user command centers and other outputs. The D7212GV3 Control Panel includes a communicator that sends event reports to selected public switched telephone network (PSTN), IP network, or general packet radio service (GPRS) destinations through four programmable route groups. Program all system functions locally or remotely (attended or unattended) through Remote Programming Software (RPS); program critical parameters on site through a keypad. The D7212GV3 Control Panel provides up to 40 individually identified points. Each point accommodates normally-open and normally-closed devices with end-of-line (EOL) resistor supervision. Each point is programmable for fire, fire supervisory, or intrusion applications.
Functions
Programmable Outputs
• 2 A alarm power at 12 VDC
• 1.4 A auxiliary power at 12 VDC
• Four alarm output patterns
u Four programmable areas with perimeter and
interior partitioning
u 40 points with flexible configuration options to meet
application specific requirements
u Commercial Wireless allows up to 32 RF points
• Automatic bell test
• Three on-board outputs, 24 off-board programmable outputs
System Response
• High performance micro‑controller provides industry leading system response
• 31 custom point indexes, including fire supervisory
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Watch mode
• Scheduled events (skeds) arm, disarm, bypass and unbypass points, control relays, and control authority levels
Area Configurations
Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate are for this function.
| D7212GV3 Control Panel
2
User Interface
• Supervises up to eight command centers (up to 32 non-supervised command centers can be used)
• Custom keypad text is fully programmable, including remote programming
• Four custom functions
• Full function command menu including custom functions
• Each user has authority by area and 16-character name
• 14 custom authority levels control user’s authority to change, add, delete passcodes, delete access control tokens, delete cards, disarm, bypass points, and initiate system tests
• Up to 40 programmable, scheduled events and up to 16 event functions for controlling relays, enabling passcodes and windows, and automatically arming and disarming areas
• Adjustable brightness or volume for command center display or sounder
• One parallel printer
The D7212GV3 provides on-premises point and system status annunciation. The fully selectable user interface customizes command center displays and allows users to create appropriate menu items and functions. Function lists can help a user become familiar with the operation of the control panel and custom functions allow users to perform complex functions with a few keystrokes. Each function can be programmed and identified by sixteen characters of custom text and can contain up to 32 keystrokes.
Notice
At least one command center per system is recommended.
Two Man Rule
Two Man Rule requires two unique passcodes on the same command center to disarm an area. Without the second passcode, the system denies entry. Two Man Rule requires the presence of two people at opening, providing added security.
Early Ambush
Early Ambush requires two passcode entries on the same command center. Enter the same passcode twice or have two unique passcodes, depending on the configuration. The first entry disarms the area and the second entry stops a timer programmed to send a duress event. If the second entry does not occur within the programmed time, the system generates a duress event. Early Ambush allows users to inspect the premises and use the system to confirm that the area is safe to enter, providing added security.
Easy Exit Control
The D7212GV3 Control Panel changes from one armed state to another armed state without disarming. For example, if you change the state from Master Arm to
Perimeter Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation.
Programmable Passcode-controlled Menu List
The system prompts users to enter a passcode prior to viewing the command center menu. The command center display shows the user the menu options allowed according to the user’s authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation.
Passcode Follows Scope
Use Passcode Follows Scope to restrict passcode arming and disarming only to the command center's immediate local area, even if the command center can report events from other areas. Passcode Follows Scope simplifies the arming and disarming procedure without limiting any other command center command capabilities.
Passcodes
User passcodes contain three to six digits. Assign each user one of 14 customized authority levels in each area. Restrict passcodes to operate only during certain times. The Two Man Rule and Early Ambush options require two passcodes, providing additional security in financial establishments such as banks.
Communications
The D7212GV3 prioritizes and sends reports to four route groups. Each group has a programmable primary and backup destination. The D7212GV3 provides flexible communications for most central stations with reporting capabilities such as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
The D7212GV3 uses the DX4020 Ethernet Network Interface Module and/or the ITS‑DX4020‑G GPRS/GSM Communicator to communicate with the Conettix D6600 and D6100i Communications Receiver/ Gateways. Using Conettix IP communication offers a secure path that includes anti-replay/anti-substitution features and provides enhanced security with encryption. Both the DX4020 and ITS‑DX4020‑G can be used for remote programming.
Security and Fire Detection
The D7212GV3 Control Panel provides eight on-board points, and up to 32 additional off-board points (depending on model and expansion interfaces). You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices.
Commercial Wireless
The Commercial Wireless platform, powered by Inovonics wireless mesh network technology, ensures superior range, reliability, and scalability for
3 | D7212GV3 Control Panel
commercial applications. Using a wide range of transmitters and repeaters, this proven technology provides flexibility and performance to meet the most stringent requirements. This exclusive protocol is available only on Commercial Wireless products. The Commercial Wireless platform sends redundant information on several multi-frequency channels within the FCC Part 15 900 MHz band, providing superior range and reliability. In comparison, systems that use a single frequency technology can only send information on one narrow band channel. Any interference within the band can cause missed signals. With wireless registration, it is easy to add this technology to any application.
Event Log
The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, and user number. View the event log from select command centers or remotely retrieve event information using RPS. RPS operators can retrieve events periodically using one phone call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver.
Scheduled Events (Skeds)
The internal clock and calendar start individually scheduled events (skeds). Skeds perform functions such as arm or disarm, relay control, or point bypassing. The D7212GV3 Control Panel offers:
• 40 scheduled events with up to 16 different functions available
• Eight opening windows and eight closing windows
• Eight user windows
• Day-of-week, date-of-month, or holiday only schedules
• Four holiday schedules of 366 days each (leap year)
Fire Test
When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The command center and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the command center shows the number of untested points.
Programming, Diagnostics and Controls
Installers can do limited programming on-site with a keypad (critical parameters; such as, .Account IDs, Central Station and RPS IP addresses and phone numbers, reporting formats, and such).They can also do full programming on-site or remotely (attended or unattended) with RPS. A programmable system passcode prevents unauthorized remote programming. D7212GV3 Control Panels accommodate up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming or disarming a system, the user is identified by name and number.
ROM Updates
An on‑site flash update key provides for easy feature enhancements without replacing ROM chips.
Certifications and approvals
FCC Designed to comply with Part 15
Region Certification
USA UL AMCX: Central Station Alarm Units (AN-
SI/UL 1610 and 1635); AMTB: Control Panels, SIA False Alarm Reduction (UL 864 and ANSI/SIA CP-01-2000); AOTX: Local Alarm Units (ANSI/UL 609 and AN­SI/UL 464); APAW: Police Station Alarm Units (ANSI/UL 365 and ANSI/UL 464); APOU: Proprietary Alarm Units (ANSI/UL
1076); NBSX: Household Burglar Alarm System Units (ANSI/UL 1023); UTOU: Control Units and Accessories, House­hold System Type (ANSI/UL 985)
CSFM see our website
Installation/configuration notes
Compatible Products
Keypads
D1260 Series Keypads (D1260, D1260W, D1260R, D1260BLK, D1260B)
D720 Series Keypads (D720, D720W, D720R, D720B)
D1255 Series Keypads (D1255, D1255W, D1255B)
D1265 Touch Screen Keypad
D279A Independent Zone Control
Detectors
D278S Four-wire Addressable Detector Base
D285/TH Photoelectric Smoke Detector Heads
D298S Addressable Detector Base
D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads
F220-B6PM/S Addressable Detector Bases with POPITs
MX775i Addressable PIR Detector
MX794i Long Range Multiplex PIR Detector
MX934i Addressable PIR Detector
MX938i Addressable PIR Detector
ZX776Z PIR Detector
ZX794Z Long Range PIR Detector
ZX835 TriTech Microwave/PIR Detector
ZX935Z PIR Detector
ZX938Z PIR Detector
Loading...