Intrusion Alarm Systems | B6512 IP control panel, 96 points
B6512 IP control panel, 96 points
www.boschsecurity.com
u Provides up to 96 points using a combination of
hardwired or wireless devices for installation
flexibility and up to 6 areas with perimeter and
interior control
The B6512 integrates intrusion and residential fire,
providing one simple user interface for both systems.
The B6512 provides up to 96 individually identified
points that can be split into 6 areas.
The control panel can communicate through its built-in
Ethernet port, or through compatible plug-in modules
that can send events over the public switched
telephone network (PSTN) or over cellular network
communications.
With the B6512, you can monitor doors, windows, and
motion within areas like showrooms or those that hold
inventory. Each user can have a personalized
passcode, a wireless keyfob, and a credential to
control the system.
u On-board Ethernet port for Conettix IP alarm
communication and remote programming,
compatible with modern IP networks including IPv6/
IPv4, Auto-IP, and Universal Plug and Play
u Installer-friendly features for simple installation and
communications, including on-board USB for easy
on-site RPS programming, plus support for Remote
Connect Service (not available in Europe, the Middle
East, or Africa), and plug-in PSTN and cellular
communication modules for simple installation and
communications
u Remote Security Control (RSC) app which allows
users to control their security systems – and view
system cameras - remotely from mobile devices
such as phones and tablets
u Provides up to 4 access doors
Use programmable authority levels with restricted
privileges to provide service, security, and cleaning
personnel with full or limited access. Use the three
programmable outputs (expandable up to 91) to turn
on lights or lock and unlock doors. Users can:
• Turn on the system to secure the stock room while
you conduct daily business.
• Perform tests to ensure your system is working
properly.
• Set your system to alarm immediately if a door opens.
• Activate the Watch feature so a tone sounds
whenever a customer enters.
• Set a schedule for your system to automatically turn
on at closing time.
• Use wireless security options to customize your
system.
| B6512 IP control panel, 96 points
2
• Add up to 4 doors of access control using the B901
Access Control Module.
Central monitoring stations provide 24-hour system
monitoring with access to vital services. Professional
security personnel can test the system, monitor
system activity, and alert the police, fire department,
or other emergency response teams if necessary.
Functions
Programmable outputs
• Three programmable on-board outputs; one high
current using a relay, and two trigger outputs
• Output A, with a contact rating of 3 Amps, can supply
up to 1.0 A total current from AUX PWR
• Outputs B and C sink up to 50 mA at 12 VDC
• Four alarm-output patterns
• Programmable bell test
Point response
• 20 custom point indexes
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Dangerous gas indicator includes carbon monoxide
(NFPA 720)
• Watch mode
User interface
• Supervision of up to 12 keypads
• Custom keypad text is fully programmable through
RPS
• Full function menu including custom functions
• Authority by area and 32 character name for each
user
• 14 custom authority levels to restrict system features
that each user can access
• Programmable primary and secondary language by
user and keypad; select from English, Spanish,
French, and Portuguese
Area configurations
Link multiple areas to a shared area such as a lobby or
common entryway. The shared area then automatically
turns On (arms) when all associate areas are armed
and turns Off (disarms) when any one associate area
is disarmed. For higher security applications, the Area
Re-Arm feature guarantees that areas are always
rearmed, and are disarmed for no longer than a
specific, configurable, amount of time (for example,
service time).
Custom functions
For added convenience, the installer can program
custom functions that allow customers to complete
complex tasks with one simple action. For example, a
custom function can bypass a group of points and arm
the system, allowing the user to perform these
functions with one easy command. Users can activate
custom functions with a keypad, keyfob, token, or
card, or the control panel can activate a function in
reaction to a faulted point, or automatically through a
scheduled event (SKED).
Passcode security
• Two-man rule. Requires two people with two unique
passcodes to be present at the time of opening.
• Early ambush. Allows users to verify that the facility is
safe by requiring two passcodes. The control panel
sends a duress event if the user does not enter the
passcode a second time after inspecting the
premises.
• Dual authentication. Requires two forms of
identification before processing certain system
commands, including turning off the system and
opening doors. A standard system user must have a
passcode, a credential (token or card), and
appropriate command authority permissions.
Door control
Using the B901 Access Control Module, the control
panel provides a fully supervised access control
solution. The solution offers 14 programmable levels
of access authority. Authority for door access is
controlled by the user level, the group of the user, the
time of day, the door state, and the area armed (On/
Off) state.
Easy exit control
The control panel changes from one On (armed) state
to another without turning off (disarming) the system.
For example, if you change the state from Part On
(Perimeter Arm) to All On (Master Arm), the control
panel complies and reports the change. Easy Exit
Control reduces the number of keystrokes, simplifying
system operation.
Programmable passcode-controlled menu list
Passcode-controlled shortcuts provide users only with
the options and information pertinent to them,
simplifying system operation.
Flexible control
The system provides the flexibility to choose added
convenience or high security. For example, you can
restrict to a keypad's immediate local area turning on
(arming) and turning off (disarming) the system with a
passcode, even if the user has access to other areas.
This is particularly useful for high security areas,
where a user may have access to the area, but would
prefer to only turn off (disarm) the area individually
rather than with the rest of the system.
Monitor Delay/Delayed Response
Create a special point index that delays the reaction of
a point for a specified time (up to 1 hour in minutes
and seconds). This delay provides time for the
specified condition to reset before activating any
annunciation. The system can annunciate locally and
send a report, if desired. When the system is armed,
the point can respond like a normal point – providing
dual functionality. Use this feature to ensure that
perimeter doors have not been propped open, or to
monitor critical areas such as computer rooms and
safes, for example.
| B6512 IP control panel, 96 points
3
System users
The system supports up to 100 users. Each user can
have a personalized passcode, a wireless keyfob, and a
credential to control the system. You can assign
passcodes to one of 14 customized authority levels in
each area that can be restricted to operate only during
certain times. Programmable primary and secondary
language by user and keypad; select from English,
Spanish, French, and Portuguese.
Communication formats
The control panel prioritizes and sends reports to four
route groups. Network and phone communications can
use one of two communication formats: Modem4,
Contact ID. Each group has a programmable primary
and backup destination.
The control panel provides flexible communications for
most central stations with reporting capabilities such
as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
IP communication
The control panel can use on-board Ethernet to
communicate with a Conettix D6600 or a Conettix
D6100IPv6 Communications Receiver/Gateway.
The control panel can optionally use a Conettix Plug-in
Cellular Communicator (B440/B441/B442/B443).
Using Conettix IP communication offers a secure path
that includes anti-replay/anti-substitution features and
provides enhanced security with up to AES 256-bit
encryption (using Cipher Block Chaining (CBC)).
The control panel supports Domain Name System
(DNS) for both remote programming and central
station communication. DNS provides ease of use,
eliminating the need to use static IP addresses as your
reporting destination, and accommodates a simple
solution for central station disaster recovery. The
control panel supports both IPv6 and IPv4 networks.
Communication paths
The control panel accommodates up to four separate
phone and four separate network paths to the central
station receiver. When resetting alarms or turning a
system on and off, the user is identified by name and
number.
Personal notification
The control panel can send text messages and emails
for personal notification over Ethernet or using a
cellular communicator. You can configure up to 16
destinations using a combination of cellular phone
numbers and email addresses. The control panel sends
notifications in the user’s programmed primary
language.
Bosch Remote Connect (Cloud)
Remote Connect simplifies connections from RPS, and
the Remote Security Control app, using Bosch Cloud
services. This service creates a secure connection to
the control panel without specific router settings or
the need for a static IP address or DNS.
Notice
The Bosch Remote Connect service is not
available in Europe, the Middle East, or Africa.
Firmware updates
The system allows remote firmware updates through
Remote Programming Software (RPS) using the RPS
Firmware Update Wizard. The Firmware Update Wizard
uses the on-board USB connection or the on-board
Ethernet (IP) connection to transfer firmware updates.
The control panel can optionally receive firmware
updates from RPS using a Conettix Plug-in Cellular
Communicator (B440/B441/B442/B443). Notice!
Cellular firmware updates require more time than
Ethernet updates and carrier data rates apply.
• Control panel updates. Remotely update the control
panel firmware for easy feature enhancements
without replacing ROM chips.
• Module update support. Remotely update the
firmware on connected SDI2 modules for easy feature
enhancements without visiting each individual
module.
A wide variety of input options
Each point:
• Single 1 kΩ, single 2 kΩ, dual 1 kΩ (1 kΩ + 1 kΩ), and
No EOL (end-of-line) (EOL) resistor options (for onboard and B208 inputs)
• Programmable for Fire, Intrusion, Access, Gas, and
Supervisory devices
• Supports hardwired and wireless devices
• Supports IP cameras by Bosch as point and output
devices
IP camera support
The control panel can integrate directly with Bosch IP
cameras, using them as fully supervised points and
outputs.
Integration of cameras allows the camera’s video
motion detection to activate points on the control
panel. The control panel’s virtual outputs can be
configured to trigger camera actions, including
sending video snapshots via email.
Video verification
Ensure priority response by law enforcement and
elimination of fines for false alarms through a
subscription to Bosch CBS video verification services.
The services also optionally enable your monitoring
center to speak real-time to an intruder to deter
further damage to your site.