Bosch B6512 Specsheet

Intrusion Alarm Systems | B6512 IP control panel, 96 points
B6512 IP control panel, 96 points
www.boschsecurity.com
u Provides up to 96 points using a combination of
hardwired or wireless devices for installation flexibility and up to 6 areas with perimeter and interior control
The B6512 integrates intrusion and residential fire, providing one simple user interface for both systems. The B6512 provides up to 96 individually identified points that can be split into 6 areas. The control panel can communicate through its built-in Ethernet port, or through compatible plug-in modules that can send events over the public switched telephone network (PSTN) or over cellular network communications. With the B6512, you can monitor doors, windows, and motion within areas like showrooms or those that hold inventory. Each user can have a personalized passcode, a wireless keyfob, and a credential to control the system.
u On-board Ethernet port for Conettix IP alarm
communication and remote programming, compatible with modern IP networks including IPv6/ IPv4, Auto-IP, and Universal Plug and Play
u Installer-friendly features for simple installation and
communications, including on-board USB for easy on-site RPS programming, plus support for Remote Connect Service (not available in Europe, the Middle East, or Africa), and plug-in PSTN and cellular communication modules for simple installation and communications
u Remote Security Control (RSC) app which allows
users to control their security systems – and view system cameras - remotely from mobile devices such as phones and tablets
u Provides up to 4 access doors
Use programmable authority levels with restricted privileges to provide service, security, and cleaning personnel with full or limited access. Use the three programmable outputs (expandable up to 91) to turn on lights or lock and unlock doors. Users can:
• Turn on the system to secure the stock room while you conduct daily business.
• Perform tests to ensure your system is working properly.
• Set your system to alarm immediately if a door opens.
• Activate the Watch feature so a tone sounds whenever a customer enters.
• Set a schedule for your system to automatically turn on at closing time.
• Use wireless security options to customize your system.
| B6512 IP control panel, 96 points
2
• Add up to 4 doors of access control using the B901 Access Control Module.
Central monitoring stations provide 24-hour system monitoring with access to vital services. Professional security personnel can test the system, monitor system activity, and alert the police, fire department, or other emergency response teams if necessary.
Functions
Programmable outputs
• Three programmable on-board outputs; one high current using a relay, and two trigger outputs
• Output A, with a contact rating of 3 Amps, can supply up to 1.0 A total current from AUX PWR
• Outputs B and C sink up to 50 mA at 12 VDC
• Four alarm-output patterns
• Programmable bell test
Point response
• 20 custom point indexes
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Dangerous gas indicator includes carbon monoxide (NFPA 720)
• Watch mode
User interface
• Supervision of up to 12 keypads
• Custom keypad text is fully programmable through RPS
• Full function menu including custom functions
• Authority by area and 32 character name for each user
• 14 custom authority levels to restrict system features that each user can access
• Programmable primary and secondary language by user and keypad; select from English, Spanish, French, and Portuguese
Area configurations
Link multiple areas to a shared area such as a lobby or common entryway. The shared area then automatically turns On (arms) when all associate areas are armed and turns Off (disarms) when any one associate area is disarmed. For higher security applications, the Area Re-Arm feature guarantees that areas are always rearmed, and are disarmed for no longer than a specific, configurable, amount of time (for example, service time).
Custom functions
For added convenience, the installer can program custom functions that allow customers to complete complex tasks with one simple action. For example, a custom function can bypass a group of points and arm the system, allowing the user to perform these functions with one easy command. Users can activate custom functions with a keypad, keyfob, token, or card, or the control panel can activate a function in reaction to a faulted point, or automatically through a scheduled event (SKED).
Passcode security
• Two-man rule. Requires two people with two unique passcodes to be present at the time of opening.
• Early ambush. Allows users to verify that the facility is safe by requiring two passcodes. The control panel sends a duress event if the user does not enter the passcode a second time after inspecting the premises.
• Dual authentication. Requires two forms of identification before processing certain system commands, including turning off the system and opening doors. A standard system user must have a passcode, a credential (token or card), and appropriate command authority permissions.
Door control
Using the B901 Access Control Module, the control panel provides a fully supervised access control solution. The solution offers 14 programmable levels of access authority. Authority for door access is controlled by the user level, the group of the user, the time of day, the door state, and the area armed (On/ Off) state.
Easy exit control
The control panel changes from one On (armed) state to another without turning off (disarming) the system. For example, if you change the state from Part On (Perimeter Arm) to All On (Master Arm), the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation.
Programmable passcode-controlled menu list
Passcode-controlled shortcuts provide users only with the options and information pertinent to them, simplifying system operation.
Flexible control
The system provides the flexibility to choose added convenience or high security. For example, you can restrict to a keypad's immediate local area turning on (arming) and turning off (disarming) the system with a passcode, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only turn off (disarm) the area individually rather than with the rest of the system.
Monitor Delay/Delayed Response
Create a special point index that delays the reaction of a point for a specified time (up to 1 hour in minutes and seconds). This delay provides time for the specified condition to reset before activating any annunciation. The system can annunciate locally and send a report, if desired. When the system is armed, the point can respond like a normal point – providing dual functionality. Use this feature to ensure that perimeter doors have not been propped open, or to monitor critical areas such as computer rooms and safes, for example.
| B6512 IP control panel, 96 points
3
System users
The system supports up to 100 users. Each user can have a personalized passcode, a wireless keyfob, and a credential to control the system. You can assign passcodes to one of 14 customized authority levels in each area that can be restricted to operate only during certain times. Programmable primary and secondary language by user and keypad; select from English, Spanish, French, and Portuguese.
Communication formats
The control panel prioritizes and sends reports to four route groups. Network and phone communications can use one of two communication formats: Modem4, Contact ID. Each group has a programmable primary and backup destination. The control panel provides flexible communications for most central stations with reporting capabilities such as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
IP communication
The control panel can use on-board Ethernet to communicate with a Conettix D6600 or a Conettix D6100IPv6 Communications Receiver/Gateway. The control panel can optionally use a Conettix Plug-in Cellular Communicator (B440/B441/B442/B443). Using Conettix IP communication offers a secure path that includes anti-replay/anti-substitution features and provides enhanced security with up to AES 256-bit encryption (using Cipher Block Chaining (CBC)). The control panel supports Domain Name System (DNS) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination, and accommodates a simple solution for central station disaster recovery. The control panel supports both IPv6 and IPv4 networks.
Communication paths
The control panel accommodates up to four separate phone and four separate network paths to the central station receiver. When resetting alarms or turning a system on and off, the user is identified by name and number.
Personal notification
The control panel can send text messages and emails for personal notification over Ethernet or using a cellular communicator. You can configure up to 16 destinations using a combination of cellular phone numbers and email addresses. The control panel sends notifications in the user’s programmed primary language.
Bosch Remote Connect (Cloud)
Remote Connect simplifies connections from RPS, and the Remote Security Control app, using Bosch Cloud services. This service creates a secure connection to the control panel without specific router settings or the need for a static IP address or DNS.
Notice
The Bosch Remote Connect service is not available in Europe, the Middle East, or Africa.
Firmware updates
The system allows remote firmware updates through Remote Programming Software (RPS) using the RPS Firmware Update Wizard. The Firmware Update Wizard uses the on-board USB connection or the on-board Ethernet (IP) connection to transfer firmware updates. The control panel can optionally receive firmware updates from RPS using a Conettix Plug-in Cellular Communicator (B440/B441/B442/B443). Notice! Cellular firmware updates require more time than Ethernet updates and carrier data rates apply.
• Control panel updates. Remotely update the control panel firmware for easy feature enhancements without replacing ROM chips.
• Module update support. Remotely update the firmware on connected SDI2 modules for easy feature enhancements without visiting each individual module.
A wide variety of input options
Each point:
• Single 1 kΩ, single 2 kΩ, dual 1 kΩ (1 kΩ + 1 kΩ), and No EOL (end-of-line) (EOL) resistor options (for on­board and B208 inputs)
• Programmable for Fire, Intrusion, Access, Gas, and Supervisory devices
• Supports hardwired and wireless devices
• Supports IP cameras by Bosch as point and output devices
IP camera support
The control panel can integrate directly with Bosch IP cameras, using them as fully supervised points and outputs. Integration of cameras allows the camera’s video motion detection to activate points on the control panel. The control panel’s virtual outputs can be configured to trigger camera actions, including sending video snapshots via email.
Video verification
Ensure priority response by law enforcement and elimination of fines for false alarms through a subscription to Bosch CBS video verification services. The services also optionally enable your monitoring center to speak real-time to an intruder to deter further damage to your site.