Intrusion Alarm Systems | B444 Conettix Plug-in 4G LTE Cellular Communicator
B444 Conettix Plug-in 4G LTE Cellular
Communicator
www.boschsecurity.com
The cellular communicator enables secure two-way IP communication over the Verizon 4G LTE cellular network by plugging into a compatible control panel or communicator interface.
Typical applications are:
•Alarm reporting to a central station
•Remote control panel programming through Remote Programming Software with supported control panels
•Remote monitoring and control through a mobile application with supported control panels
•Personal notification using SMS for compatible control panels
Notice
Cellular capability requires an Installer Services account and appropriate data plan.
uSecure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon 4G LTE cellular network
uRemote programming and monitoring of compatible Bosch panels
uPersonal SMS message and e-mail notification options
uDirect configuration from Bosch Remote Programming Software (RPS) eliminating the need for separate configuration
uSimple LED status information and advanced keypad diagnostics available with easy 2 step plug-in installation, troubleshooting, and maintenance
System overview
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Callout Description |
Callout Description |
||||||||||||||||||
|
|
|
|
||||||||||||||||
1 |
Cellular communicator |
7 |
Remote PC’s network |
||||||||||||||||
|
|
|
|
|
|
|
connection |
||||||||||||
|
|
|
|
||||||||||||||||
2 |
Compatible control panel |
8 |
Remote PC running RPS |
||||||||||||||||
|
|
|
|
||||||||||||||||
3 |
Antenna cable |
9 |
Personal SMS notification |
||||||||||||||||
|
|
|
|||||||||||||||||
4 |
Magnetic base antenna |
10 Ethernet connection |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | B444 Conettix Plug-in 4G LTE Cellular Communicator
5 |
Base station on wireless |
11 Central monitoring station |
carrier’s network |
|
|
|
|
|
6 |
IP network cloud |
|
|
|
|
Functions
Activation
The B444 module is shipped pre-activated.
The B444-C module needs to be activated. Activate the module by emailing: installer.services@us.bosch.com, or by call Bosch Installer Services at: 800-289-0096, option 6.
Conettix IP communication via Cellular
In addition to the security provided by the network operator, the cellular communicator uses our Conettix IP protocol that supports:
•Flexible polling intervals
•Resistance to Denial of Service attacks
•128-bit to 256-bit AES encryption with Cypher Block Chaining
•Anti-replay/anti-substitution keys
Easy Installation, troubleshooting, and maintenance
•No networking expertise required at field site (no firewall or router settings)
•No PC or special tools required for installation and troubleshooting
•Service plans and settings managed through RPS
•Diagnostic LEDs for on-site troubleshooting
LED |
Function |
Blue (heartbeat) |
System status indicator |
|
|
Red |
Unacceptable signal strength |
|
|
Yellow |
Marginal signal strength |
|
|
1 Green |
Good signal strength |
|
|
2 Green |
Very good signal strength |
|
|
Remote programming of Bosch control panels
The cellular communicator supports secure RPS programming of compatible Bosch control panels.
Personal notification and control
The cellular communicator supports the Bosch Remote Security Control mobile application and can be configured for SMS personal notification reports to mobile phones or e-mail addresses.
Remote Connect Service Support
Remote Connect Service enables a secure control panel connection to remote programming software (RPS) using Bosch Cloud services. The service allows a secure TLS connection to a control panel without specific port and router settings and without a static IP or DNS.
Certifications and approvals
Region |
Certification |
|
USA |
Verizon |
Open Development Certified |
|
|
|
|
|
|
Region |
Regulatory compliance/quality marks |
|
|
|
|
USA |
UL |
UL 864 - Standard for Control Units and |
|
|
Accessories for Fire Alarm Systems |
|
UL |
UL 1076 - Proprietary Burglar Alarm |
|
|
Units and Systems |
|
UL |
UL 1610 - Central Station Burglar Alarm |
|
|
Units |
|
UL |
UL 365 - Police Station Connected Bur- |
|
|
glar Alarm Units |
|
UL |
UL 609 - Standard for Local Burglar |
|
|
Alarm Units and Systems |
|
UL |
UL 636 - Holdup Alarm Units and Sys- |
|
|
tems |
|
UL |
UL 985 - Household Fire Warning Sys- |
|
|
tem Units |
|
UL |
UL 1023 - Household Burglar Alarm Sys- |
|
|
tem Units |
|
CSFM |
see www.boschsecurity.com (the Bosch |
|
|
website) |
|
FCC |
Part 15 Class B |
Canada |
ULC |
S1871-20121210 |
|
|
|
Installation/configuration notes
Mounting considerations
The module plugs into any compatible control panel, available in a variety of enclosures.
Wiring considerations
The module connects to any compatible control panel without tools or physical wiring for power. When used with the B450, the B450 is wired to the control panel data bus. The cellular module has a screw on SMA antenna connection.
Compatibilities
Devices |
B9512G/B9512G-E, B8512G/B8512G-E |
|
B6512 |
|
B6512/B5512/B4512/B3512, B5512E/ |
|
B4512E/B3512E control panel with firmware |
|
v3.05 or higher (direct insertion) |
|
The module is compatible with most Bosch |
|
control panels when used with a B450 Conettix |
|
Plug-in Communicator Interface with firmware |
|
v3.05 or higher. Refer to the B450 datasheet |
|
for complete control panel compatibility listings. |
|
B465 Conettix Universal Dual Path |
|
Communicator with firmware v2.0 or higher. |
|
B40 antennas |
|
|
Cellular |
4G LTE - Cat 1 |
|
|