Bosch B444-C Specsheet

Bosch B444-C Specsheet

Intrusion Alarm Systems | B444 Conettix Plug-in 4G LTE Cellular Communicator

B444 Conettix Plug-in 4G LTE Cellular

Communicator

www.boschsecurity.com

The cellular communicator enables secure two-way IP communication over the Verizon 4G LTE cellular network by plugging into a compatible control panel or communicator interface.

Typical applications are:

Alarm reporting to a central station

Remote control panel programming through Remote Programming Software with supported control panels

Remote monitoring and control through a mobile application with supported control panels

Personal notification using SMS for compatible control panels

Notice

Cellular capability requires an Installer Services account and appropriate data plan.

uSecure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon 4G LTE cellular network

uRemote programming and monitoring of compatible Bosch panels

uPersonal SMS message and e-mail notification options

uDirect configuration from Bosch Remote Programming Software (RPS) eliminating the need for separate configuration

uSimple LED status information and advanced keypad diagnostics available with easy 2 step plug-in installation, troubleshooting, and maintenance

System overview

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Callout Description

Callout Description

 

 

 

 

1

Cellular communicator

7

Remote PC’s network

 

 

 

 

 

 

 

connection

 

 

 

 

2

Compatible control panel

8

Remote PC running RPS

 

 

 

 

3

Antenna cable

9

Personal SMS notification

 

 

 

4

Magnetic base antenna

10 Ethernet connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 | B444 Conettix Plug-in 4G LTE Cellular Communicator

5

Base station on wireless

11 Central monitoring station

carrier’s network

 

 

 

 

6

IP network cloud

 

 

 

 

Functions

Activation

The B444 module is shipped pre-activated.

The B444-C module needs to be activated. Activate the module by emailing: installer.services@us.bosch.com, or by call Bosch Installer Services at: 800-289-0096, option 6.

Conettix IP communication via Cellular

In addition to the security provided by the network operator, the cellular communicator uses our Conettix IP protocol that supports:

Flexible polling intervals

Resistance to Denial of Service attacks

128-bit to 256-bit AES encryption with Cypher Block Chaining

Anti-replay/anti-substitution keys

Easy Installation, troubleshooting, and maintenance

No networking expertise required at field site (no firewall or router settings)

No PC or special tools required for installation and troubleshooting

Service plans and settings managed through RPS

Diagnostic LEDs for on-site troubleshooting

LED

Function

Blue (heartbeat)

System status indicator

 

 

Red

Unacceptable signal strength

 

 

Yellow

Marginal signal strength

 

 

1 Green

Good signal strength

 

 

2 Green

Very good signal strength

 

 

Remote programming of Bosch control panels

The cellular communicator supports secure RPS programming of compatible Bosch control panels.

Personal notification and control

The cellular communicator supports the Bosch Remote Security Control mobile application and can be configured for SMS personal notification reports to mobile phones or e-mail addresses.

Remote Connect Service Support

Remote Connect Service enables a secure control panel connection to remote programming software (RPS) using Bosch Cloud services. The service allows a secure TLS connection to a control panel without specific port and router settings and without a static IP or DNS.

Certifications and approvals

Region

Certification

USA

Verizon

Open Development Certified

 

 

 

 

 

Region

Regulatory compliance/quality marks

 

 

 

USA

UL

UL 864 - Standard for Control Units and

 

 

Accessories for Fire Alarm Systems

 

UL

UL 1076 - Proprietary Burglar Alarm

 

 

Units and Systems

 

UL

UL 1610 - Central Station Burglar Alarm

 

 

Units

 

UL

UL 365 - Police Station Connected Bur-

 

 

glar Alarm Units

 

UL

UL 609 - Standard for Local Burglar

 

 

Alarm Units and Systems

 

UL

UL 636 - Holdup Alarm Units and Sys-

 

 

tems

 

UL

UL 985 - Household Fire Warning Sys-

 

 

tem Units

 

UL

UL 1023 - Household Burglar Alarm Sys-

 

 

tem Units

 

CSFM

see www.boschsecurity.com (the Bosch

 

 

website)

 

FCC

Part 15 Class B

Canada

ULC

S1871-20121210

 

 

 

Installation/configuration notes

Mounting considerations

The module plugs into any compatible control panel, available in a variety of enclosures.

Wiring considerations

The module connects to any compatible control panel without tools or physical wiring for power. When used with the B450, the B450 is wired to the control panel data bus. The cellular module has a screw on SMA antenna connection.

Compatibilities

Devices

B9512G/B9512G-E, B8512G/B8512G-E

 

B6512

 

B6512/B5512/B4512/B3512, B5512E/

 

B4512E/B3512E control panel with firmware

 

v3.05 or higher (direct insertion)

 

The module is compatible with most Bosch

 

control panels when used with a B450 Conettix

 

Plug-in Communicator Interface with firmware

 

v3.05 or higher. Refer to the B450 datasheet

 

for complete control panel compatibility listings.

 

B465 Conettix Universal Dual Path

 

Communicator with firmware v2.0 or higher.

 

B40 antennas

 

 

Cellular

4G LTE - Cat 1

 

 