Bosch AMAX panel 2100, AMAX panel 3000, AMAX panel 3000 BE, AMAX panel 4000 User Manual

AMAX panel
AMAX panel 2100 | AMAX panel 3000 | AMAX panel
3000 BE | AMAX panel 4000
en User Manual
Table of contents
1
Safety 5
2
Short information 6
2.1 Introduction 6
2.2 Keypads 6
2.3 Keypad Indicators 8
2.4 Quick Keypad Operations Instructions 10
2.5 User Menu 15
3
Arming and Disarming the System 16
3.1 Arming the System 16
3.1.1 Arming in AWAY Mode 16
3.1.2 Arming in STAY Mode 18
3.1.3 Forced Arming 19
3.2 Disarming the System 21
3.2.1 Disarming with a Keypad 21
3.2.2 Disarming with a Master Keypad 21
3.2.3 Disarming with Key Switch 21
3.2.4 Disarming with RADION RF Keyfob 21
4
Changing the Menu Language 23
5
System Test 24
5.1 Siren Test 24
5.2 Communication Test 24
5.3 Walk Test Mode 24
6
Bypassing 26
6.1 Bypassing/Unbypassing Zones 26
6.1.1 How to Bypass/Unbypass a Zone via Text Keypad 26
6.1.2 How to Bypass/Unbypass a Zone via LED/LCD Keypad 26
6.2 Bypassing Faults or Tamper Conditions 27
7
Schedules 28
8
Macros 29
8.1 Recording Macros 29
8.2 Playing Macros 31
AMAX panel Table of Contents | en 3
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
9
Codes 32
9.1 Add/Change User Codes 32
9.2 Change Individual Code 34
10
Keypad Alarm Operation Commands 35
10.1 Keypad Panic Alarm 35
10.2 Keypad Fire Alarm 35
10.3 Keypad Medical Alarm 35
11
Domestic Dialing 36
11.1 Domestic Dialing Alarm 36
11.2 Confirming the Domestic Call 36
12
Event Log Recall Mode 37
12.1 How to Select All Event Log Recall Mode 37
12.2 How to Select EN Event Log Recall Mode 37
12.3 How to Select Dialer Event Log Recall Mode 37
13
Faults and Tamper Conditions 38
13.1 System Fault or Tamper Analysis Mode via Text Keypad 38
13.2 System Fault or Tamper Analysis Mode via LED/LCD Keypad
38
14
Resetting the Control Panel 44
15
Troubleshooting 45
4 en | Table of Contents AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
Safety
Danger!
Electricity Injuries due to electricity are possible if the system is not operated correctly or if the system is opened or modified.
Never open or modify the system. –
Please contact your installer if you want to get your system modified.
!
Caution!
Sensitive components Damage of sensitive components is possible if the system is not handled carefully or if the system is opened or modified.
Always handle the system carefully. –
Never open or modify the system.
Please contact your installer if you want to get your system
modified.
1
AMAX panel Safety | en 5
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
Short information
Introduction
This manual contains information on how to operate the system easily and quickly. It describes the main steps required for operation of the AMAX panel 2100/3000/4000 together with a text and/or a LED/LCD keypad described in Keypads, page 6. It is possible to add an optional text keypad as a master keypad. Detailed information about the installation of this and other modules and devices, advanced settings and programming can be found in the installation manual. Information on the main steps required for basic system installation and setup can be found in the quick start manual.
Keypads
The following text keypad can be used for operating AMAX panel 2100/3000/4000.
IUI-AMAX4-TEXT
The following LED/LCD keypads can be used for operating AMAX panel 2100/3000/4000.
2
2.1
2.2
6 en | Short information AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
IUI-AMAX3-LED8 IUI-AMAX3-LED16
IUI-AMAX-LED8 IUI-AMAX-LCD8
Notice!
Only a text keypad can be used as a master keypad.
AMAX panel Short information | en 7
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
Keypad Indicators
The following table shows an overview and a description of the keypad indicator icons.
Keypad Indicator Icons
Status Definition
1 2 3 ….
ZONE (1-8)
on Zone is triggered.
off Zone is normal.
Fast flash (0.25 seconds lights on/0.25 seconds lights off)
Zone was alarmed or is in alarm status.
Slow flash (1 second lights on/1 second lights off)
Zone is manually bypassed or interior Zone is in STAY arm mode.
AWAY
on System is armed in
AWAY mode.
off System not armed in
AWAY mode.
Slow flash (1 second lights on/1 second lights off)
Exit time.
Fast flash (0.25 seconds lights on/0.25 seconds lights off)
Programming mode or code function mode. STAY indicator flashes simultaneously.
on System is armed in
STAY mode.
2.3
8 en | Short information AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
STAY
off System not armed in
STAY mode.
Slow flash (1 second lights on/1 second lights off)
Exit time.
Fast flash (0.25 seconds lights on/0.25 seconds lights off)
Programming mode or code function mode. AWAY indicator flashes simultaneously. When bypass function is performed, only the STAY indicator flashes.
MAINS
on AC main power is
normal.
Slow flash (1 second lights on/1 second lights off)
AC main power supply failed.
FAULTS
on System fault or Tamper
condition is present.
off System is in normal
status.
Flashes System fault or tamper
condition must be acknowledged.
on System is disarmed.
All icons Flashing No communication to
the keypad.
AMAX panel Short information | en 9
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
The following table shows an overview and a description of the keypad sound icons.
Sound Indicator Definition
Short beep A keypad button has been pressed.
Short beep, followed by a one-second beep
The requested operation is refused. Incorrect operation signal.
Two short beeps The system accepted the code. The
system executed the requested function.
One short beep every minute
Fault tone, unacknowledged system failure.
One short beep every two seconds
Exit time started.
Continued sound Last 10 seconds on exit time
Keypad fault or tamper sound (fault or tamper to be acknowledged)
Keypad alarm sound
Continuous 0.5 second beep, stops for 0.5 seconds
Entry delay time (until alarm
ends or system is disarmed)
Exit delay time (stops 10 seconds before exit delay stops)
Quick Keypad Operations Instructions
The following table shows an overview of the quick keypad operations and the corresponding user permissions. For information on changing codes and defining user permission levels, please refer to Codes, page 32.
2.4
10 en | Short information AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
Function Command
Default User Code = 2580 / 2581
D A B S M1M2I
N
Arm/Disarm
AWAY Arm [code] + [#] / [#] for 3 sec.
(quick arm)
√ √ √ √ √ √ √
AWAY Arm All Areas (only on master keypad)
[code] + [0] [0] + [#] √ √ √ √ √ √ √
Direct AWAY Arm (only on master keypad
[code] + [2-digit area no.] + [#]
√ √ √
STAY Arm [code] + [*] / [*] for 3 sec.
(quick arm)
√ √ √ √ √ √ √
STAY Arm All Areas (only on master keypad)
[code] + [0] [0] + [*] √ √ √ √ √ √ √
Direct STAY Arm (only on master keypad
[code] + [2-digit area no.] + [*]
√ √ √
Disarm [code] + [#] √ √ √ √ √ √
Disarm One Area (only on a master keypad)
[code] + [2-digit area no.] + [#]
√ √ √ √ √ √
Disarm All Areas (only on master keypad)
[code] + [#] √ √ √ √ √ √
AMAX panel Short information | en 11
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
Display
Display Info (Fault/Tamper Analysis)
[code] + [2] [1] + [#] √ √ √
Bypass
Bypass/Unbypass Zone
[code] + [3] [1] + [#] + [2­digit zone no.] + [#]
√ √ √ √ √
Bypass Fault/ Tamper
[code] + [3] [4] + [#] √ √ √
Reset
Reset Fault/ Tamper (In some country versions only the installer can reset a tamper alarm)
[code] + [6] + [#] √ √ √ √
Macros
Record Macro 1 [code] + [8] [1] + [#] +
sequence to be recorded + [#] for 3 sec.
√ √ √ √
Record Macro 2 [code] + [8] [2] + [#] +
sequence to be recorded + [#] for 3 sec.
√ √ √ √
Record Macro 3 [code] + [8] [3] + [#] +
sequence to be recorded + [#] for 3 sec.
√ √ √ √
Play Macro 1 [code] + long press [1] /
[1] for 3 sec. (quick macro)
* * * * * * √
12 en | Short information AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
Play Macro 2 [code] + long press [2] /
[2] for 3 sec. (quick macro)
* * * * * * √
Play Macro 3 [code] + long press [3] /
[3] for 3 sec. (quick macro)
* * * * * * √
Alarm commands
Keypad Emergency Alarm
long press [1] and [3] or [*] and [#]
√ √
Keypad Fire long press [4] and [6] √ √
Keypad Medical Alarm
long press [7] and [9] √ √
Other Commands
Switch to Master Keypad
[code] + [0] [0] [0] + [#] (only on text keypad)
√ √ √ √
Switch to Area 01-16
[code] + [0] [2-digit area no.] + [#] (only on text keypad)
√ √ √ √
Display all Event Log
[code] + [2] [2] + [#] (only on text keypad)
√ √
Display EN Event Log
[code] + [2] [3] + [#] (only on text keypad)
√ √
Display Dialer Event Log
[code] + [2] [4] + [#] (only on text keypad)
√ √
Siren Test [code] + [4] [1] + [#] √ √ √
Communication Test
[code] + [4] [2] + [#] √ √ √
Walk Test [code] + [4] [3] + [#] √ √ √
AMAX panel Short information | en 13
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
Daylight Saving Time (+1h)
[code] + [5] [2] + [#] √ √ √
Daylight Saving Time (-1h)
[code] + [5] [3] + [#] √ √ √
Add/Change User Code
[code] + [5] [4] + [#] √ √ √
Change Individual Code
[code] + [5] [5] + [#] √ √ √
Call Back [code] + [5] [7] + [#] √ √ √
Change Language [code] + [5] [8] + [#] + [2-
digit no. for available languages] + [#] 01=EN; 02=DE; 03=ES; 04=FR ; 05=PT; 06=PL; 07=NL; 08=SE; 09=TR
√ √ √
Installer Access [code] + [7] [1] + [#]
(enable) [code] + [7] [2] + [#] (disable)
√ √
System Reset [code] + [9] [9] [8] [9] +
[#]
√ √ √
D = Duress User A = Arming User B = Basic User S = Super User M1 = Master User 1 M2 = Master User 2 IN = Installer * This function can be enabled/disabled individually for every user. For further information, please refer to Add/Change User Codes, page 32.
14 en | Short information AMAX panel
2015.05 | 04 | F.01U.295.569 Bosch Sicherheitsysteme GmbH
User Menu
The following table shows an overview of the user menu.
FAULT/TAMP INQUIRE
[ / ]USER MENU
ARM/DISARM
ARM AWAY ARM STAY DISARM
ZN/FLT/TAMP BYPASS
ZONE BYPASS BYPASS INQUIRE BYPASS FLT./ TAMP.
INQUIRE
ALL EVENT RECALL EN EVENT RECALL DIAL EVENT RECALL EVENT PRINT PRINTER ENABLE
RESET
SYSTEM TEST
SIREN TEST COMMUNICATIN TEST WALK TEST
RECORD :END # 3s
AREA SWITCH
SYSTEM SETTINGS
DAYL.SAV.TIME +1h DAYL.SAV.TIME -1h ADD/CHG USER CODE CHANGE INDIV CODE INITIATE CALL BACK CHANGE LANGUAGE MACRO START
INPUT MACRO No 1-3
START PLAY
SCHEDULE ENABLE
INSTALLER ACCESS
ENABLE INSTALLER DISABLE INSTALLER
2.5
AMAX panel Short information | en 15
Bosch Sicherheitsysteme GmbH 2015.05 | 04 | F.01U.295.569
Loading...