Behringer 1006 Quick Start Guide

0 (0)
Behringer 1006 Quick Start Guide

Quick Start Guide

FILTAMP MODULE 1006

Legendary 2500 Series 24 dB Low-Pass VCF and VCA Module for Eurorack

Controls

(1) (2) (3)

(4)

(9)

(5)

(10)

(6)

 

(7)

(11)

(8)

 

(9)EXPONENTIAL/LINEAR switch – Select between a linear or more natural exponential VCA response.

(10)CV 2 to VCA knob – Attenuate the voltage that is passed from the CV 2 input to the VCA.

(11)CV 1 to VCA knob – Attenuate the voltage that is passed from the CV 1 input to the VCA.

(12)IN A – Connect an input signal via 3.5 mm TS cable.

(13)IN B – Connect an input signal via 3.5 mm TS cable.

(14)KYBD – Connect a voltage that can be used to control the VCF frequency.

(15)CV 1 – Connect a voltage that can be used to control the VCF frequency or VCA level.

(16)CV 2 – Connect a voltage that can be used to control the VCF frequency or VCA level.

(17)OUT – Send the processed signal to other modules via 3.5 mm TS cable.

Power Connection

(12) (13) (14) (15) (16) (17)

(1)FILTER – Adjusts the cutoff frequency for the filter.

(2)FILTER RESONANCE – Boosts the resonance frequencies selected with the Filter knob, potentially causing

VCF oscillation.

(3)AMPLIFIER GAIN – Controls the level of the VCA.

(4)KEYBOARD knob – Attenuate the voltage connected to the KYBD input, which controls the cutoff frequency of the filter.

(5)IN B knob – Adjusts the level of the signal connected to the IN B input.

(6)CV 2 to VCF knob – Attenuate the voltage that is passed from the CV 2 input to the VCF.

(7)IN A knob – Adjusts the level of the signal connected to the IN A input.

(8)CV 1 to VCF knob – Attenuate the voltage that is passed from the CV 1 input to the VCF.

The unit comes with the required power cable for connecting to a standard Eurorack power supply system. Follow these steps to connect power to the module. It is easier to make these connections before the module has been mounted into a rack case.

1.Turn the power supply or rack case power off and disconnect the power cable.

2.Insert the 16-pin connector on the power cable into the socket on the power supply or rack case. The connector has a tab that will align with the gap in the socket, so it cannot be inserted incorrectly. If the power supply does not have a keyed socket, be sure to orient pin 1 (-12 V) with the red stripe on the cable.

3.Insert the 10-pin connector into the socket on the back of the module. The connector has a tab that will align with the socket for correct orientation.

4.After both ends of the power cable have been securely attached, you may mount the module in a case and turn on the power supply.