Chapter 1 updated, motor choke added, DeviceNet, SynqNet and EtherCat expansion cards added, chap
ter 6 restructured, feedback section updated, cross section (awg)
Part number scheme new, shock-hazard protection new, servo system graphics / different mains supply
06/07
networks expanded&removed, feedback expanded, enc. emulation, switch-on and switch-off behavior ex
panded, AS expanded, accessories removed, DC Bus link expanded, timing diagramm motor brake, dispo
sal acc. to WEEE-2002/96/EG, new structure, SynqNet removed, Quickstart integrated, warnings updated
-
-
-
WINDOWS is a registered trademark of Microsoft Corp.
HIPERFACE is a registered trademark of Max Stegmann GmbH
EnDat is a registered trademark of Dr. Johannes Heidenhain GmbH
Technical changes which improve the performance of the equipment may be made without prior notice !
Printed in the Federal Republic of Germany
All rights reserved. No part of this work may be reproduced in any form (by printing, photocopying, microfilm or
any other method) or stored, processed, copied or distributed by electronic means without the written permission of
BECKHOFF.
BECKHOFF
06/2007Contents
1General
1.1About this manual ....................................................................... 7
1.2Hints for the online edition (PDF format) ...................................................... 7
This manual describes the digital servo amplifiers of the AX2040/2070 series (standard version).
A more detailed description of the expansion cards which are currently available and the digital
connection to automation systems can be found on the accompanying CD-ROM in Acrobat-Reader
format (system requirements: WINDOWS with Internet browser, Acrobat Reader) in several
language versions.
You can print this documentation on any standard printer. A printed copy of the documentation is
available from us at extra cost.
This manual makes the following demands on qualified personnel :
Transport :only by personnel with knowledge in handling electrostatically
sensitive components.
Unpacking:only by electrically qualified personnel.
Installation :only by electrically qualified personnel
Setup :only by personnel with extensive knowledge of electrical
engineering / drive technology
06/2007General
1.2Hints for the online edition (PDF format)
Bookmark:
Table of contents and index are active bookmarks.
Table of contents and index in the text:
The lines are active cross references. Click on the desired line and the appropriate page is indicated.
Page/chapter numbers in the text:
Page/chapter numbers with cross references are active. Click at the page/chapter number to reach
the indicated target.
1.3Symbols used
ð p.
Danger to personnel
from electricity and its
effects effects
see pagelspecial emphasis
Danger to maschinery,
general warning
Important no
tes
-
AX2040/2070 Product Manual7
General
1.4Abbreviations used
The abbreviations used in this manual are explained in the table below.
AbbreviationMeaning
AGNDAnalog ground
ASRestart Lock, option
BTB/RTOReady to operate
CANFieldbus (CANopen)
CECommunité Européenne (EC)
CLKClock signal
COMSerial interface for a PC-AT
DGNDDigital ground
DINGerman Institute for industrial Standards
DiskMagnetic storage (diskette, hard disk)
EEPROMElectrically erasable programmable memory
EMCElectromagnetic compatibility
EMIElectromagnetic interference
ENEuropean standard
ESDElectrostatic discharge
F-SMAFiber Optic Cable connector according to IEC 60874-2
IECInternational Electrotechnical Commission
IGBTInsulated Gate Bipolar Transistor
INCIncremental Interface
ISOInternational Standardization Organization
LEDLight-emitting diode
MBMegabyte
NIZero pulse
NSTOPLimit-switch input for CCW rotation (left)
PELVProtected low voltage
PGNDGround for the interface
PSTOPLimit-switch input for CW rotation (right)
PWMPulse-width modulation
RAMVolatile memory
R
regen(RB
R
Bext
R
Bint
RESResolver
ROD 426 (EEO)A quad B encoder
PLCProgrammable logic controller
SRAMStatic RAM
SSISynchronous serial interface
ULUnderwriters Laboratory
VACAC voltage
VDCDC voltage
VDEVerein deutscher Elektrotechniker
XGNDGround for the 24V supply
)Regen resistor
External regen resistor
Internal regen resistor
06/2007BECKHOFF
8AX2040/2070 Product Manual
BECKHOFF
2Safety
2.1Safety Instructions
Only properly qualified personnel are permitted to perform activities such as trans
l
port, installation, setup and maintenance. Properly qualified persons are those who
are familiar with the transport, assembly, installation, setup and operation of the pro
duct, and who have the appropriate qualifications for their job. The qualified person
nel must know and observe:
IEC 60364 or DIN VDE 0100
IEC 60664 or DIN VDE 0110
national accident prevention regulations or BGV A3
06/2007Safety
-
-
-
Read this documentation before carrying out installation and setup. Incorrect hand
l
ling of the servo amplifier can lead to personal injury or material damage. It is vital
that you keep to the technical data and information on connection requirements (on
the nameplate and in the documentation).
The servo amplifiers contain electrostatically sensitive components which may be
l
damaged by incorrect handling. Ground yourself before touching the servo amplifier
by touching any unpainted metal surface. Avoid contact with highly insulating mater
ials (artificial fabrics, plastic film etc.). Place the servo amplifier on a conductive sur
face.
The manufacturer of the machine must produce a hazard analysis for the machine
l
and take appropriate measures to ensure that unforeseen movements do not result in
personal injury or material damage.
lDo not open or touch the equipment during operation. Keep all covers and cabinet
doors closed during operation. Touching the equipment is allowed during installation
and commissioning for properly qualified persons only. Otherwise, there are deadly
hazards, with the possibility of death, severe injury or material damage.
—During operation, servo amplifiers may have uncovered live
components, depending on their level of enclosure protection.
—Control and power connections may be live, even though the
motor is not rotating.
—Servo amplifiers may have hot surfaces during operation.
Surface can reach temperatures above 80°C.
-
-
-
l
Never undo any electrical connections to the servo amplifier while it is live. There is a
danger of electrical arcing with damage to contacts and personal injury.
Wait at least five minutes after disconnecting the servo amplifier from the main
supply power before touching potentially live sections of the equipment (e.g. con
tacts) or undoing any connections. Capacitors can still have dangerous voltages pre
sent up to five minutes after switching off the supply power. To be sure, measure the
voltage in the DC Bus link and wait until it has fallen below 40V.
Safety instructions
-
AX2040/2070 Product Manual9
-
Safety
2.2Use as directed
The servo amplifiers are components which are built into electrical equipment or machines,
l
and can only be used as integral components of such equipment.
The manufacturer of the machine must generate a hazard analysis for the machine, and
l
take appropriate measures to ensure that unforeseen movements cannot cause injury or
damage to any person or property.
The AX2040/2070 family of servo amplifiers can be connected directly to symmetrically eart
l
hed(grounded) three-phase industrial mains supply networks [TN-system, TT-system with
earthed(grounded) neutral point, not more than 5000rms symmetrical amperes, 480VAC
maximum] when protected by fuses type Fusetron FRS-R-50 for AX20 640 or FRS-R-80
class RK5 for AX20 670, manufactured by Bussman, or equivalent, 480VAC min.
The use of external mains chokes and mains filters is required.
The servo amplifiers must not be operated directly on power supply networks >230V without
l
an earth (ground) or with an asymmetrical earth (ground).
Connection to other mains supply networks ð p. 46.
Periodic overvoltages between outer conductor (L1, L2, L3) and housing of the servo ampli
l
fier may not exceed 1000V (peak value).
Transient overvoltages (< 50µs) between the outer conductors may not exceed 1000V.
Transient overvoltages (< 50µs) between outer conductors and housing may not exceed
2000V.
The regen resistors have to be protected by fuses type Limitron KLM, rated for 500VAC/DC
l
06/2007BECKHOFF
-
-
The AX2040/2070 family of servo amplifiers is only intended to drive specific brushless syn-
l
chronous servomotors with closed-loop control of torque, speed and/or position. The rated
voltage of the motors must be at least as high as the DC bus link voltage of the servo amplifier. The motor must have integral thermal protection.
l
The servo amplifiers may only be operated in a closed switchgear cabinet, taking into
account the ambient conditions defined on page 19 and the dimensions shown on page 34.
Ventilation or cooling may be necessary to prevent enclosure ambient from exceeding 45°C
(113°F).
l
Use copper wire only. Wire size may be determined from EN 60204 (or table 310-16 of the
NEC 60°C or 75°C column for AWG size).
l
We only guarantee the conformance of the servo amplifiers with the standards for industrial
areas (page 11), if the components are delivered by BECKHOFF.
l
Consider the specifications on page 70 when you use the personnel safe restart lock -AS-.
10AX2040/2070 Product Manual
BECKHOFF
06/2007Standards
3Standards
3.1European directives and standards
Servo amplifiers are components that are intended to be incorporated into electrical plant and
machines for industrial use. When the servo amplifiers are built into machines or plant, the amplifier
must not be used until it has been established that the machine or equipment fulfills the require
ments of the EC Machinery Directive (98/37/EC), the EC EMC Directive (89/336/EEC) and the EC
Low Voltage Directive (73/23/EEC.)
Standards to be applied for conformance with the EC Machinery Directive (98/37/EEC):
EN 60204-1 (Safety and Electrical Equipment in Machines)
EN 12100(Safety of Machines)
The manufacturer of the machine must generate a hazard analysis for the machine,
and take appropriate measures to ensure that unforeseen movements cannot
cause injury or damage to any person or property.
Standards to be applied for conformance with the EC Low Voltage Directive (73/23/EEC):
EN 60204-1 (Safety and Electrical Equipment in Machines)
EN 50178(Electronic Equipment in Power Installations)
EN 60439-1 (Low Voltage Switchgear Combinations)
-
Standards to be applied for conformance with the EC EMC Directive (89/336/EEC):
EN 61000-6-1 / EN 61000-6-2 (Interference Immunity in Residential & Industrial Areas)
EN 61000-6-3 / EN 61000-6-4 (Interference Generation in Residential & Industrial Areas)
The manufacturer of the machine/plant is responsible for ensuring that it meets the limits required
by the EMC regulations. Advice on the correct installation for EMC (such as shielding, grounding,
treatment of connectors and cable layout) can be found in this documentation.
The machine/plant manufacturer must check whether other standards or EC
Directives must be applied to the machine/plant.
3.2American Directives and Standards
Chapter in process
3.3Asian Directives and Standards
Chapter in process
AX2040/2070 Product Manual11
Standards
3.4Approvals
3.4.1CE - conformance
Conformance with the EC EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC)
is mandatory for the supply of servo amplifiers within the European Community. Product standard
EN 61800-3 is applied to ensure conformance with the EMC Directive. The Declaration of Confor
mity form can be found on our website (download area).
Concerning noise immunity the servo amplifier meets the requirements to the 2nd environmental
category (industrial environment). For noise emission the amplifier meets the requirement to a pro
duct of the category C2 (motor cable £ 25m).
This product can cause high-frequency interferences in non industrial
environments which can require measures for interference suppression.
With a motor cable length from 25m onwards, the servo amplifier meets the requirement to the
category C3.
The servo amplifiers have been tested in a defined configuration, using the system components that
are described in this documentation. Any divergence from the configuration and installation descri
bed in this documentation means that you will be responsible for carrying out new measurements to
ensure conformance with regulatory requirements. The standard EN 50178 is applied to ensure
conformance with the Low Voltage Directive.
06/2007BECKHOFF
-
-
-
3.4.2UL and cUL- Conformance
This servo amplifier is listed under UL file number E195162.
UL (cUL)-certified servo amplifiers (Underwriters Laboratories Inc.) fulfill the relevant U.S. and
Canadian standard (in this case UL 840 and UL 508C).
This standard describes the fulfillment by design of minimum requirements for electrically operated
power conversion equipment, such as frequency converters and servo amplifiers, which is intended
to eliminate the risk of fire, electric shock, or injury to persons, being caused by such equipment.
The technical conformance with the U.S. and Canadian standard is determined by an independent
UL (cUL) inspector through the type testing and regular check-ups.
Apart from the notes on installation and safety in the documentation, the customer does not have to
observe any other points in direct connection with the UL (cUL)-certification of the equipment.
UL 508C
UL 508C describes the fulfillment by design of minimum requirements for electrically operated
power conversion equipment, such as frequency converters and servo amplifiers, which is intended
to eliminate the risk of fire being caused by such equipment.
UL 840
UL 840 describes the fulfillment by design of air and insulation creepage spacings for electrical
equipment and printed circuit boards.
12AX2040/2070 Product Manual
BECKHOFF
4Handling
4.1Transport
Only by qualified personnel in the manufacturer’s original recyclable packaging
l
Avoid shocks
l
Temperature–25 to +70°C (-13...158°F), max. 20K/hr rate of change
l
Humiditymax. 95% relative humidity, no condensation
l
The servo amplifiers contain electrostatically sensitive components which can be
l
damaged by incorrect handling. Discharge yourself before touching the servo ampli
fier. Avoid contact with highly insulating materials (artificial fabrics, plastic films etc.).
Place the servo amplifier on a conductive surface.
If the packaging is damaged, check the unit for visible damage. In this case, inform the ship
l
per and the manufacturer.
4.2Packaging
Cardboard box, can be recycled
l
Dimensions:(HxWxD) 410x470x490 mm
l
06/2007Handling
-
-
Weight incl. accessories approx. ca. 25 Kg
l
Labeling : nameplate outside at the box
l
4.3Storage
l
Storage only in the manufacturer’s original recyclable packaging
l
Max. stacking height3 cartons
l
Storage temperature-25 to +55°C, max. rate of change 20°C / hour
l
Storage humidity5 ... 95% relative humidity, no condensation
l
Storage durationLess than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC for
about 30 minutes to the terminals L1 / L2.
4.4Maintenance
The instruments do not require any maintenance, opening the instruments invalidates the warranty.
Cleaning :— if the casing is dirty: clean with Isopropanol or similar
— if there is dirt inside the unit it must be cleaned by the manufacturer
— dirty protective grill on fan must be cleaned with a dry brush
do not immerse or spray
4.5Disposal
In accordance to the WEEE-2002/96/EG-Guidelines we take old devices and accessories back for
professional disposal, if the transport costs are taken over by the sender. Send the devices to:
Beckhoff Automation GmbH
Eiserstr. 5
D-33415 Verl
AX2040/2070 Product Manual13
Package
5Package
5.1Package supplied
When you order a AX2040/2070 series amplifier, you will receive:
—AX2040/2070
—mating connectors X3, X4
The mating SubD connectors are not part of the package!
—Online documentation on CD-ROM
—Setup software DRIVE.EXE on CD-ROM
06/2007BECKHOFF
Accessories:
—Mains filter 3EF required
—Mains choke 3L required
—AC Servomotor (linear or rotary)
—motor cable as a cut-off length
—brake cable as a cut-off length
—feedback cable (pre-assembled) or
both feedback connectors separately, with feedback cable as length
—external regen resistor BAS, usually required
—communications cable to the PC (ð p.67) or Y-adapter (ð p.88) for parameter setting of up
to 6 servo amplifiers from one PC
—power cable, control cables, fieldbus cables (as lengths)
5.2Nameplate
The nameplate depicted below is attached to the side of the servo amplifier.
The information described0 below is printed in the individual fields.
Synchronous servomotors, linear motors and asynchronous motors can be used
l
Power supply
With external mains filter and mains choke directly off grounded 3~ system,
l
230V
208V
-10%
-10%
... 480V
... 480V
+10%
+10%
,50Hz,
,60Hz,
+10%
)
TN-system, TT-system with earthed (grounded) neutral point, not more than 5000 rms symmetrical amperes, 480VAC maximum; when protected by fuses type Fusetron FRS-R-80
(Class RK5), manufactured by Bussman, or equivalent 480VAC min
Connection to other mains supply networks only with insulating transformer ð p. 46
l
BB6 rectifier bridge, off 3-phase earthed (grounded) supply, integral inrush circuit
l
Fusing (e.g. fusible cutout) provided by the user
l
All shielding connections directly on the amplifier
l
Output stage: IGBT- module with isolated current measurement
l
Regen circuit: with dynamic distribution of the regen power between several
amplifiers on the same DC bus link circuit, external regen resistor
l
DC bus link voltage 260 ... 900 VDC, can be switched in parallel
l
Interference suppression filter for the 24V aux. supply (to category C2) is integrated
External interference suppression filter for the supply input (to category C2)
required. External mains choke required.
Integrated safety
l
Safe electrical separation to EN 50178 between the power input / motor connections and the
signal electronics, provided by appropriate insulation/creepage distances and complete elec
trical isolation
Temperature monitoring of servo amplifier and motor
(when using our motors with our pre-assembled cables)
-
Auxiliary supply voltage 24VDC
l
Electrically isolated, internal fusing, from an external 24VDC psu, e.g. with isolating transfor
mer
16AX2040/2070 Product Manual
-
BECKHOFF
06/2007Technical description
Operation and parameter setting
With our user-friendly software for setup through the serial interface of a PC
l
Direct operation by means of two keys on the servo amplifier and a 3-character LED display
l
for status display in case of no PC available
Fully programmable via RS232 interface
l
Completely digital control
Digital current controller (space vector pulse-width modulation, 62.5 µs)
l
Freely programmable digital speed controller (62.5 µs or 250 µs)
l
Integral position controller with adaptation possibilities for customer needs (250 µs)
l
Pulse direction interface integrated for connection of a servomotor to a stepping motor
l
control
Evaluation of the resolver signals and sine-cosine signals of a high-resolution encoder
l
Encoder simulation (incremental or SSI)
l
Comfort functions
2 analog monitor outputs
l
4 programmable digital inputs (normally, two are defined as limit-switch inputs)
l
2 programmable digital outputs
l
Freely programmable combinations of all digital signals
l
Expansions
-I/O-14/08- expansion card, ð p. 96
l
l
PROFIBUS DP expansion card, ð p. 99
l
SERCOS expansion card, ð p. 100
l
DeviceNet expansion card, ð p. 102
l
EtherCat expansion card, ð p. 105
l
-2CAN- Expansion module, separated connectors for CAN bus and RS232, ð p. 106
AX2040/2070 Product Manual17
Technical description
6.2Technical data
Rated dataDIMAX2040AX2070
Rated-supply voltage (grounded system)
Rated installed load for S1 operationkVA3050
Rated DC bus link voltageV=290...675
Rated output current (rms value, ± 3%)
at 230VArms4085
at 400VArms4080
at 480VArms4070
Peak output current (max. ca. 5s, ± 3%)
at 230V80160
at 400V80160
at 480V80140
Clock frequency of the output stagekHz8
Technical data of the regen circuit—ð p.22
Overvoltage protection thresholdV450...900
Form factor of the output current
(at rated data and min. load inductance)
Bandwidth of subordinate current controllerkHz> 1.2
Residual voltage drop at rated currentV5
Quiescent dissipation, output stage disabledW40
Dissipation at rated current (incl. power
supply losses, without regen dissipation)
Inputs/Outputs
Setpoint 1/2, resolution 14bit/12bitV
Common-mode voltage max.V
Input resistance to AGND
Digital inputs
Digital outputs, open collector
BTB/RTO output, relay contacts
Aux. power supply, electrically isolatedV24 (-0% +15%)
without brakeA2 (max. 16)
Aux. power supply, electrically isolatedV24 (-0% +15%)
with brake (consider voltage loss!)A5 (max. 16)
Min/max. output current, brakeA0.75 / 3
Connections
Control signals—Combicon 5,08 / 18 pole , 2,5mm²
Power signals—Terminals 10mm² — 50mm²
Resolver input—SubD 9pole (socket)
Sine-cosine encoder input—SubD 15pole (socket)
PC-interface, CAN—SubD 9pole (plug)
Encoder simulation, ROD (EEO) / SSI—SubD 9pole (plug)
Thermal control, Motor—min. 15VDC, 5mA
Mechanical
Weightkg19.521
Height without shield sheet, w/o eyes (w. eyes)mm345 (375)
Height with shield sheet, w/o eyes (w. eyes)mm484 (495)
Widthmm250
Depth without connectorsmm300
Depth with connectorsmm325
06/2007BECKHOFF
V~3 x 230V-10% ... 480V+10%, 50 Hz
V~3 x 208V-10% ... 480V+10%, 60 Hz
—1.01
W400700
±10
±10
kW
Vlow 0...7 / high 12...36
mA7
Vmax. 30
mA10
VDC max. 30, AC max. 42
mA500
20
18AX2040/2070 Product Manual
BECKHOFF
6.2.1Recommended torques
ConnectorRecommended torque
X3, X40.3 Nm (2.25 in lb)
X100,3 Nm (2.25 in lb)
X06...8 Nm (45... 60 in lb)
6.2.2Fusing
Internal fusing
CircuitInternal fuse
Auxiliary supply 24V4 AT
Regen resistorelectronic
External fusing
Fusible cutouts or similar
(Fuse UL time delay)
AC supplyF
Type of branch circuit fuses:
Class RK5, 480V min
Regen resistorF
* (x=SorS-Rfor480V applicationsx=NorN-Rfor230V applicationsð p. 10)
Note: The AX2040/2070 drives are suitable for use on a circuit capable of delivering not more
than 5000rms symmetrical amperes, 480VAC max.
N1/2/3
B1/2
06/2007Technical description
AX2040AX2070
50 AT (FRx-50) *80 AT (FRx-80) *
KLM 20KLM 30
6.2.3Ambient conditions, ventilation, mounting position
Storage, hints
Transport, hints
Supply voltage tolerances
Input power (ð p.46)
Aux. power supply
Ambient temperature in operation
Humidity in operation
Site altitude
Pollution levelPollution level 2 to EN60204/EN50178
Vibrations
Noise emission
Enclosure protectionIP 20
Mounting position
Ventilation
Make sure that there is sufficient forced ventilation within the switchgear cabinet.
ð p.13
ð p.13
min 3x230V
min 3x208V
AC / max 3x 480V
-10%
AC / max 3x 480V
-10%
24 VDC (-0% +15%), check voltage drop
0to+45
o
C (32 to 113 °F) at rated data
+45 to +55°C (113 to 131 °F) with power derating
rel. humidity 85%, no condensation
up to 1000m a.m.s.l. without restriction
1000...2500m a.m.s.l. with power derating 1.5%/100m
Class 3111 according to IEC 721-3-3
max. 45 dB(A)
generally vertical. ð p.34
forced convection by built-in fans
+10%
,50Hz
+10%
,60Hz
2.5% / K
AX2040/2070 Product Manual19
Technical description
6.2.4Conductor cross-sections
Observe the technical data for connection cables ð p. 41.
Following EN 60204 (for AWG: table 310-16 of the NEC 60°C or 75°C column), we recommend for
single-axis systems:
AC connection
DC bus link25 mm² (2 awg), shielded for lengths > 20 cm, 600V,105°C (221°F)
+24 V / XGND
Regen resistorð p.41, min. 10 mm² (6 awg), shielded, 1000V,105°C (221°F)
For multi-axis systems, please note the special operating conditions in your installation
To reach the max. permitted cable length, observe cable requirements ð p. 41.
25 mm² (2 awg), shielded between filter and amplifier, 600V,105°C
(221°F)
ð p.41, cross section see manual of the used motor series,
capacitance <250pF/m, 600V,105°C (221°F)
4x2x0.25 mm² (22awg) twisted pairs, shielded, max.100m,
capacitance <120pF/m
7x2x0,25 mm² (22awg) twisted pairs, shielded, max.50m,
capacitance <120pF/m
min. 1.5 mm² (14 awg), 600V,105°C (221°F), shielded,
check voltage drop
max. 2.5 mm² (12 awg), check voltage drop
06/2007BECKHOFF
6.3LED display
A 3-character LED display shows the amplifier status after switching on the 24V supply
(ð p.91). During operation and parameter setting of the amplifier via the keys on the front panel, the
parameter and function numbers (ð p.91) are displayed, as well as the numbers of any errors
which occur (ð p.92).
6.4Grounding system
AGND — ground for analog inputs/outputs, internal analog/µC ground
DGND — ground for digital inputs/outputs, optically isolated
XGND — ground for external 24V aux. voltage, optically and inductively isolated
PGND — ground for encoder emulation, RS232, CAN, PROFIBUS, optically isolated
The potential isolation is shown in the block diagram (ð p. 43).
20AX2040/2070 Product Manual
BECKHOFF
06/2007Technical description
6.5Control for motor holding brake
A 24 V / max. 3 A holding brake in the motor can be controlled directly by the servo amplifier.
Check voltage drop, measure the voltage at brake input and check brake function
(brake and no brake). This function does not ensure personnel safety!
The brake function must be enabled through the BRAKE parameter (setting: WITH BRAKE). In the
diagram below you can see the time and functional relationships between the ENABLE signal,
speed setpoint, speed and braking force.
During the internal ENABLE delay time of 100 ms (DECDIS) the speed setpoint of the servo ampli
fier is internally driven down a 10 ms ramp to 0. The brake output is switched on when a speed of
5rpm is reached or after 5s (EMRGTO) the latest.
The rise (tbrH) and fall (tbrL) times of the holding brake which is built into the motors are different
for the various types of motor (see motor manual).
A description of the interface can be found on page 48.
A safe (for personnel) operation of the holding brake requires an additional “make” (n.o.) contact in
the brake circuit and a suppressor device (varistor) for the brake.
Recommended brake circuit diagram :
AX2040/2070
AX2040/2070 Product Manual21
-
Technical description
6.6Regen circuit
During braking with the aid of the motor, energy is fed back to the servo amplifier. This energy is
converted into heat in the regen resistor (ð p. ). The regen resistor is switched into circuit by the
regen circuit. The regen circuit (thresholds) are adjusted to the supply voltage with the help of the
setup software.
Our customer service can help you with the calculation of the regen power which is required. A des
cription of the interface can be found on page 48.
Functional description:
1.- Individual amplifiers, not coupled through the DC bus link (DC+, DC-)
The circuit starts to respond at a DC bus link voltage of 400V, 720V or 840V (depending on the
supply voltage). If the energy which is fed back from the motor, as an average over time or as a
peak value, is higher than the preset regen power, then the servo amplifier will output the status
“regen power exceeded” and the regen circuit will be switched off. At the next internal check of the
DC bus link voltage (after a few ms) an overvoltage will be detected and the servo amplifier will be
switched off with the error message “Overvoltage F02” (ð p. 92).
The BTB/RTO contact (terminal X3/2,3) will be opened at the same time (ð p. 66).
2.- Several servo amplifiers coupled through the DC bus link circuit (DC+, DC-)
Thanks to the built-in regen circuit with its patented power distribution, several amplifiers (even with
different current ratings) can be operated off a common DC bus link. This is achieved by an auto
matic adjustment of the regen thresholds (which vary, because of tolerances).
The regen energy is distributed equally among all the amplifiers. The combined power of all the
amplifiers is always available, as continuous or peak power. The switch-off takes place as described
under 1. (above) for the servo amplifier with the lowest switch-off threshold (resulting from tolerances).
The RTO (BTB) contact of this amplifier (terminals X3/2,3) will be opened at the same time
(ð p. 66).
Switch-off level of regen circuitV800 - 830
Overvoltage F02V900
Continuous power of regen circuit (R
Pulse power, external (R
max. 1s)kW4570
Bext
) max.kW6
Bext
22AX2040/2070 Product Manual
BECKHOFF
06/2007Technical description
6.7Switch-on and switch-off behavior
This chapter describes the switch-on and switch-off behavior of the AX2040/2070 and the steps
required to achieve operational stopping or emergency stop behavior that complies with standards.
The servo amplifier’s 24 V supply must remain constant. The ASCII commands
ACTFAULT (error response) and STOPMODE (ENABLE signal response) dictate
how the drive will behave.
STOPMODEACTFAULT
0 (default)0
11 (default)
Behavior during a power failure
The servo amplifiers use an integrated circuit to detect if one or more input phases (power supply
feed) fail. The behavior of the servo amplifier is set using the setup software: Under “Response to
Loss of Input Phase” (PMODE) on the Basic Setup screen, select:
Warning if the higher-level control system is to bring the drive to a standstill: Warning n05 is
l
output if an input phase is missing, and the motor current is limited to 4 A. The servo ampli
fier is not disabled. The higher-level control system can now selectively end the current cycle
or start bringing the drive to a standstill. Therefore, the error message “MAINS BTB, F16" is
output on a digital output of the servo amplifier and evaluated by the control system, for ins
tance.
Error message if the servo amplifier is to bring the drive to a standstill: Error message F19
l
is output if an input phase is missing. The servo amplifier is disabled and the BTB contact
opens. Where the factory setting is unchanged (ACTFAULT=1), the motor is braked using
the set “EMERGENCY STOP RAMP”.
Behavior when undervoltage threshold is reached
If the undervoltage threshold is undershot in the DC bus link (the threshold value depends on the
type of servo amplifier), the error message “UNDERVOLTAGE, F05" is displayed. The drive
response depends on the ACTFAULT/STOPMODE setting.
Behavior (see also ASCII reference in the online help of the se
tup software)
Motor coasts to a standstill in an uncontrolled manner
Motor is braked in a controlled manner
-
-
-
Behavior with enabled “holding brake” function
Servo amplifiers with an enabled holding brake function have a special procedure for switching off
the output stage ( ð p. 21). Removing the ENABLE signal triggers electrical braking. As with all
electronic circuits, the general rule applies that there is a possibility of the internal “holding brake”
module failing. Bringing a motor to a standstill using a holding brake in a way that is personnel safe
also requires an electromechanical “make” contact for the holding equipment and a suppressor
device for the brake.
Behavior of the restart lock -AS-
With the personnel safe restart lock –AS-, the drive can be secured on standstill using its internal
electronics so that even when power is being supplied, the drive shaft is protected against uninten
tional restart. The chapter “Personnel safe restart lock -AS-” describes how to use the restart lock
–AS-. See page 69 onwards.
-
AX2040/2070 Product Manual23
Technical description
06/2007BECKHOFF
6.7.1Behavior in standard operation
The behavior of the servo amplifier always depends on the current setting of a number of different
parameters (e.g., ACTFAULT, VBUSMIN, VELO, STOPMODE, etc.; see online help). The diagram
below illustrates the correct functional sequence for switching the servo amplifier on and off.
DC bus link
Motor speed
Power stage
Enable (internal)
Devices which are equipped with a selected “Brake” function use a special sequence for switching
off the output stage (ð p. 21).
The built-in restart lock -AS- can be used to switch off the drive via a positive-action (approved by
Trade Liability Association) safety relay, so that personnel safety is ensured at the drive shaft
(ð p. 69).
24AX2040/2070 Product Manual
BECKHOFF
06/2007Technical description
6.7.2Behavior in the event of an error (with standard setting)
The behavior of the servo amplifier always depends on the current setting of a number of different
parameters (e.g., ACTFAULT, VBUSMIN, VELO, STOPMODE, etc.; see online help). The diagram
shows the startup procedure and the procedure that the internal control system follows in the event
of one or more electrical supply phases failing, assuming that the standard parameter settings
apply.
Even if there is no intervention from an external control system (in the example, the ENABLE signal
remains active), the motor is immediately braked using the emergency stop ramp if an input phase
error is detected and assuming that no changes have been made to the factory setting (ACT
FAULT=1).
-
AX2040/2070 Product Manual25
Technical description
06/2007BECKHOFF
6.8Stop/Emergency Stop Function to EN 60204
With the personnel safe restart lock –AS- (see page 69 onwards) the drive can be
secured on standstill (torque-free) using its internal electronics so that even when
power is being supplied, the drive shaft is protected against unintentional restart.
6.8.1Stop: Standards
The Stop function is used to shut down the machine in normal operation. The Stop functions are
defined by EN 60204 (VDE 0113), paragraphs 9.2.2 and 9.2.5.3.
Category 0:Shut-down by immediate switching-off of the energy supply to the
drive machinery (i.e. an uncontrolled shut-down);
Category 1:A controlled shut-down , whereby the energy supply to the drive
machinery is maintained to perform the shut-down, and the energy
supply is only interrupted when the shut-down has been completed;
Category 2:A controlled shut-down, whereby the energy supply to the drive
machinery is maintained.
The parameters “STOPMODE” and “ACTFAULT” must be set to 1 in order to
implement the stop categories. If necessary, change the parameters via the
terminal screen of the setup software and store the data in the EEPROM.
The Stop Category must be determined by a risk evaluation of the machine. In addition, suitable
means must be provided to guarantee a reliable shut-down.
Category 0 and Category 1 Stops must be operable independently of the operating mode, whereby
a Category 0 Stop must have priority. Stop functions must be implemented by disconnection of the
appropriate circuitry, and have priority over assigned start functions.
If necessary, provision must be made for the connection of protective devices and lock-outs. If
applicable, the Stop function must signal its status to the control logic. A reset of the Stop function
must not create a hazardous situation.
26AX2040/2070 Product Manual
BECKHOFF
06/2007Technical description
6.8.2Emergency Stop: Standards
The emergency Stop function is used for the fastest possible shut-down of the machine in a dan
gerous situation. The Emergency Stop function can be triggered by the actions of a single person. It
must be fully functional and available at all times. The user must not have to work out how to ope
rate this mechanism.
The Emergency Stop function is defined by EN 60204 (VDE 0113), paragraph 9.2.5.4.
In addition to the requirements for Stop, the emergency Stop must fulfil the following requirements:
emergency stop must have priority over all other functions and controls in all operating situa
l
tions;
the energy supply to any drive machinery that could cause dangerous situations must be
l
switched off as fast as possible, without causing any further hazards (e.g. by using mechani
cal latching devices that do not require an external supply of energy, by counter-current bra
king in Stop Category 1);
the reset must not initiate a restart.
l
If necessary, provision must be made for the additional connection of emergency stop devices (see
EN 60204, "Requirements for emergency stop devices").
The Emergency Stop must be effective as a stop of either Category 0 or Category 1.
The Emergency Stop Category must be determined by a risk evaluation of the machine.
Category 0
Only hard-wired, electromechanical components may be used for the Category 0 Emergency Stop
function. It must not be triggered using switching logic (hardware or software), by transferring commands via a communication network, or via a data link.
The drive must be shut down using an electromechanical circuit. If the connected servo motor has
an integrated brake, this must always be controlled by an electromechanical circuit as well.
-
-
-
-
-
Category 1
With the Category 1 Emergency Stop function, there must be absolute certainty in terms of the
power supply for the machine drives being switched off (i.e., secured) using electromechanical components. Additional Emergency Stop equipment may be connected. Bringing the motor to a standstill by interrupting the mains supply and using controlled electronic braking. The 24 V supply for the
servo amplifier must remain constant. The issue of which circuit should be used is highly dependent
on the requirements of the application at hand.
Usually a brake in a servo motor only has the function of a holding brake. To ensure an emergency
stop function, the braking torque that is required must be checked. If the holding brake fulfills the
dynamic requirements, it must be taken into acount that this application will cause increased wear.
The parameters “STOPMODE” and “ACTFAULT” must be set to 1 in order to
implement the stop categories. If necessary, change the parameters via the
terminal screen of the setup software and store the data in the EEPROM.
AX2040/2070 Product Manual27
Technical description
06/2007BECKHOFF
6.8.3Implementation of the Stop Category 0
Bringing the motor to a standstill by immediately switching off the amplifier power supply (STOP
MODE & ACTFAULT parameters set to 1). The switching sequence is precisely determined by
this circuit in order to avoid undesirable fault messages and servo amplifier failures.
It is not possible to achieve a Category 0 shut-down with the servo amplifier alone, since hard-wired
electromechanical components are compulsory for this type of disconnection.
A brake that is built into the motor must have an additional electromechanical control circuit, as well
as the control through the AX2040/2070, in order to meet Category 0.
Usually a brake in a servo motor only has the function of a holding brake. To ensure an emergency
stop function, the braking torque that is required must be checked. If the holding brake fulfills the
dynamic requirements, it must be taken into acount that this application will cause increased wear.
Circuit suggestion
(with EMERGENCY STOP Category 0, control function with contactor relays)
-
AX2040/2070
28AX2040/2070 Product Manual
BECKHOFF
06/2007Technical description
6.8.4Implementation of the Stop Category 1
Bringing the motor to a standstill by interrupting the mains supply and using controlled electronic
braking (STOPMODE & ACTFAULT parameters set to 1). The 24 V supply for the AX2040/2070
must remain constant.
The drive is braked in a controlled manner during the stopping (disabling) procedure. If the speed
VEL0 (see sequence diagram in chapter 6.5) is undershot, the holding brake is applied and the
output stage is disabled.
As soon as two separate time periods (set at the time relay) have elapsed, the mains supply and
the holding brake are electrically isolated.
Should an internal AX2040/2070 fault occur, the motor is forced to a standstill once
K20 drops out.
Circuit suggestion
(with EMERGENCY STOP Category 1, control function with contactor relays)
AX2040/2070
AX2040/2070 Product Manual29
Technical description
06/2007BECKHOFF
6.8.5Implementation of the Stop Category 2
The machine receives an operational stop (disable) command and brakes the drive using the set
braking ramp (STOPMODE & ACTFAULT parameters set to 1).
The drive is braked in a controlled manner during the stopping (disabling) procedure. If the speed
VEL0 (see sequence diagram in chapter 6.5) is undershot, the holding brake is applied and the
output stage is disabled. In this case, there is no interruption of the electrical supply.
If the electrical supply is switched off, not only will the controlled braking procedure be performed,
but the mains supply and the holding brake will also be electrically isolated following a time period
set at the time relay.
Circuit suggestion
(with EMERGENCY STOP Category 1, control function with contactor relays)
AX2040/2070
30AX2040/2070 Product Manual
BECKHOFF
6.9Shock-hazard protection
6.9.1Leakage current
Leakage current via the PE conductor results from the combination of equipment and cable leakage
currents. The leakage current frequency pattern comprises a number of frequencies, whereby the
residual-current circuit breakers definitively evaluate the 50Hz current. For this reason, the leakage
current cannot be measured using a conventional multimeter.
As a rule of thumb, the following assumption can be made for leakage current on our low-capacity
cables at a mains voltage of 400 V, depending on the clock frequency of the output stage:
Ileak=nx20mA+Lx1mA/m at 8kHz clock frequency at the output stage
Ileak=nx20mA+Lx2mA/m at a 16kHz clock frequency at the output stage
(where Ileak=leakage current, n=number of amplifiers, L=length of motor cable)
At other mains voltage ratings, the leakage current varies in proportion to the voltage.
Example:2 x servo amplifiers + a 25m motor cable at a clock frequency of 8kHz:
2 x 20mA + 25m x 1mA/m = 65mA leakage current.
Since the leakage current to PE is more than 3.5 mA, in compliance with EN50178
the PE connection must either be doubled or a connecting cable with a
cross-section >10mm² must be used.
The following measures can be used to minimise leakage currents.
— Reduce the length of the engine cable
— Use low-capacity cables (see p.41)
06/2007Technical description
6.9.2Residual-current circuit breakers (FI)
In conformity with DIN IEC 60364-4-41 – Regulations for installation and EN 60204 – Electrical
equipment of machinery, residual-current circuit-breakers (called FI below) can be used provided
the requisite regulations are complied with.
The AX2040/2070 is a 3-phase system with a B6 bridge. Therefore, FIs which are sensitive to allcurrents must be used in order to detect any d.c. fault current. Refer to chapter 6.9.1 for the rule of
thumb for determining the leakage current.
Rated residual currents in the FI
10 -30 mA
50 -300 mA
Recommendation: In order to protect against direct contact (with motor cables
<5m) we recommend that each servo amplifier be protected individually using a
30mA residual-current circuit-breaker which is sensitive to all currents.
If you use a selective FI circuit-breaker, the more intelligent evaluation process will prevent spurious
tripping of the circuit-breakers.
Protection against "indirect contact" (personal fire protection) for stationary and mo
bile equipment, as well as for "direct contact".
Protection against "indirect contact" (personal fire protection) for stationary equip
ment
-
-
AX2040/2070 Product Manual31
Technical description
6.9.3Isolating transformers
If protection against indirect contact is absolutely essential despite a higher leakage current, or if an
alternative form of shock-hazard protection is sought, the AX2040/2070 can also be operated via an
isolating transformer.
A ground-leakage monitor can be used to monitor for short circuits.
We would advise you to keep the length of wiring between the transformer and the
servo amplifier as short as possible.
06/2007BECKHOFF
32AX2040/2070 Product Manual
BECKHOFF
06/2007Mechanical Installation
7Mechanical Installation
7.1Important notes
Protect the servo amplifier from impermissible stresses. In particular, do not let any compo
l
nents become bent or any insulation distances altered during transport and handling. Avoid
contact with electronic components and contacts.
Ensure that there is an adequate flow of cool, filtered air into the bottom of the switchgear
l
cabinet or use heat exchangers. Observe page 19.
Take care that the servo amplifier and motor are earthed (grounded) properly. Do not use
l
painted (non-conductive) mounting plates.
Don't mount devices, which produce magnetic fields, directly beside the servo amplifier.
l
Strong magnetic fields could directly affect internal components. Install devices which pro
duce magnetic field with distance to the servo amplifiers and/or shield the magnetic fields.
7.2Guide to mechanical installation
The following notes should assist you to carry out the mechanical installation in a sensible
sequence, without overlooking anything important.
In a closed switchgear cabinet. Observe page 19 .
Site
Ventilation
The site must be free from conductive or corrosive materials.
For the mounting position in the cabinet ð p. 34
Check that the ventilation of the servo amplifier is unimpeded
and keep within the permitted ambient temperature ð p. 19 .
Keep the required space clear above and below the servo amplifier ð p34.
-
-
Assembly
Grounding
Shielding
Assemble the servo amplifier and power supply, filter and choke close
together on the conductive, grounded mounting plate in the cabinet.
EMC-compliant (EMI) shielding and grounding (ð p. 45)
Earth (ground) the mounting plate, motor housing and CNC-GND of the controls.
Notes on connection techniques are on page 40
AX2040/2070 Product Manual33
Mechanical Installation
7.3Assembly
Ask our customer service for information for pass through mounting
Material :4 hexagon socket screws to DIN 912, M6
Tool required :5 mm Allen key
06/2007BECKHOFF
- A.4.038.4/12
AX2040/2070
34AX2040/2070 Product Manual
BECKHOFF
7.4Dimensions
06/2007Mechanical Installation
AX2040/2070 Product Manual35
Mechanical Installation
06/2007BECKHOFF
This page has been deliberately left blank.
36AX2040/2070 Product Manual
BECKHOFF
8Electrical Installation
8.1Important Notes
Check the combination of servo amplifier and motor. Compare the rated voltage and current
l
of the units. Carry out the wiring according to the connection diagram on page 39.
Make sure that the maximum permissible rated voltage at the terminals L1, L2, L3 or +DC,
l
–DC is not exceeded by more than 10% even in the most unfavourable case
(see EN 60204-1 Section 4.3.1). An excessive voltage on these terminals can lead to
destruction of the regen circuit and the servo amplifier.
The use of external mains chokes and mains filters is required.
l
The fusing of the AC supply input and the 24V supply is installed by the user (ð p. 19).
l
Route power and control cables separately. We recommend a separation of at least 200mm.
l
This improves the interference immunity required by EMC regulations.
Install all shielding with large areas (low impedance), with metallised connector housings or
l
shield connection clamps where possible. Earth (ground) the shielding at both ends (ðp.45).
Notes on connection techniques can be found on page 40.
Feedback lines may not be extended, since thereby the shielding would be interrupted and
l
the signal processing could be disturbed.
The cable between servo amplifier and regen resistor must be shielded.
l
Install all heavy-current cables with an adequate cross-section, as per EN 60204 (ð p. 20)
l
and use the requested cable material (ð p. 41) to reach max. cable length.
Wire the BTB/RTO contact in series into the safety circuit of the installation. The safety cir-
l
cuit must control the mains relay. Only in this way is the monitoring of the servo amplifier
assured.
l
It is permissible to alter the servo amplifier settings by using the setup software.
Any other alterations will invalidate the warranty.
06/2007Electrical Installation
Never disconnect the electrical connections to the servo amplifier while it is live. In
unfavourable circumstances this could result in destruction of the electronics.
Residual charges in the capacitors can have dangerous levels up to 300 seconds
after switching off the mains supply voltage. Measure the voltage in the DC bus
link (+DC/-DC), and wait until the voltage has fallen below 40V.
Control and power connections can still be live, even when the motor is not
rotating.
AX2040/2070 Product Manual37
Electrical Installation
06/2007BECKHOFF
8.2Guide to electrical installation
The following notes should assist you to carry out the electrical installation in a sensible sequence,
without overlooking anything important.
Cable selec
tion
Grounding
Shielding
Wiring
-
Select cables according to EN 60204 (ð p. 20)
EMC-compliant (EMI) shielding and grounding (ð p. 45)
Earth (ground) the mounting plate, motor housing and CNC-GND of the controls.
Notes on connection techniques are on page 40
Route power leads and control cables separately
Wire the BTB/RTO contact in series into the safety loop
— Connect the digital control inputs to the servo amplifier
— Connect up AGND (also if fieldbuses are used)
— Connect the analog setpoint, if required
— Connect up the feedback unit (resolver and/or encoder)
— Connect the encoder emulation, if required
— Connect the expansion card (see corresponding manual on the CD-ROM)
— Connect the motor cables, connect shielding to EMI connectors at both ends
— Connect motor-holding brake, connect shielding to EMI connectors at
both ends
— Connect the external regen resistor (with fusing)
— Connect aux. supply (for max. permissible voltage values ð p. 19)
— Connect mains choke and mains filter (shielded lines between filter and
servo amplifier)
— Connect main power supply (for max. permissible voltage values ð p. 19)
— Connect PC (ð p. 67).
Final check
— Final check of the implementation of the wiring,
— according to the wiring diagrams which have been used.
38AX2040/2070 Product Manual
BECKHOFF
8.3Wiring
8.3.1Important notes
Only professional staff who are qualified in electrical engineering are allowed to install the
servo amplifier.The installation procedure is described as an example. A different procedure may
be sensible or necessary, depending on the application of the equipment.
We provide further know-how through training courses (on request).
Caution !
Only install and wire up the equipment when it is not live, i.e. when neither the
mains power supply nor the 24 V auxiliary voltage nor the operating voltages of
any other connected equipment is switched on.
Take care that the cabinet is safely disconnected (with a lock-out, warning signs
etc.). The individual voltages will be switched on for the first time during setup.
06/2007Electrical Installation
The ground symbol
that you must take care to provide an electrically conductive connection with the
largest possible surface area between the unit indicated and the mounting plate in
the switchgear cabinet.
This connection is for the effective grounding of HF interference, and must not be
confused with the PE- symbol W (a protective measure to EN 60204).
Use the following connection diagrams:
Overview: page 45
Mains power: page 47
Motor: page 48
Feedback: page 49ff
Electronic Gearing / Master Slave
X, which you will find in all the wiring diagrams, indicates
AX2040/2070 Product Manual39
Electrical Installation
06/2007BECKHOFF
8.3.2Shielding connection to the front panel
AX2040/2070
Remove the outer covering of the
cable and the shielding braid from
the cores for the required length.
Secure the cores with a cable tie.
Remove the outer covering of the
cable over a length of about 30mm,
without damaging the shielding
braid.
Pull a cable tie through the slot in
the shielding rail (front panel) of the
servo amplifier.
Use the cable tie to clamp the
shielding braid of the cable firmly
to the shielding rail.
AX2040/2070
40AX2040/2070 Product Manual
BECKHOFF
8.3.3Technical data for cables
Further information on the chemical, mechanical and electrical characteristics of the cables can be
obtained from out customer service .
Observe the restrictions in the chapter "Conductor cross-sections" on page 20.
To operate the amplifier with the max. permitted cable length, you must use cable
material which meets the requirements on the capacity given below.
Cables drawn bold are shielded. Electrical ground is drawn with
dash-dotted lines.
42AX2040/2070 Product Manual
BECKHOFF
8.5Block diagram
The block diagram below is just an overview.
06/2007Electrical Installation
AX2040/2070 Product Manual43
Electrical Installation
8.6Pin assignments
06/2007BECKHOFF
44AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.7Connection diagram (overview)
Reference Safety Instructions (ð p.9) and
Use As Directed (ð p.10) !
AX2040/2070
ð p.51ff
ð p.50
ð p.48
ð p.47
ð p.63
ð p.64
ð p.65
ð p.66
ð p.48
ð p.47
ð p.69
ð p.61
ð p.62
ð p.56
ð p.59
ð p.68
ð p.67
ð p.96
ð p.99
ð p.100
ð p.102
ð p.105
ð p.106
AX2040/2070 Product Manual45
Electrical Installation
06/2007BECKHOFF
8.8Power supply
8.8.1Connection to various mains supply networks
This page illustrates all the possible connection variations for different electrical supply networks.
An isolating transformer is always required for 400...480V mains networks without
earth(ground) and for networks with asymmetrical earth(ground).
AX2040/2070
208V with 60Hz only
230...480V with 50Hz or 60Hz
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
AX2040/2070
46AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.8.2Mains supply connection (X0)
—EMI filter and mains choke (required) provided by the user
—Fusing (e.g. fusible cut-outs) provided by the user ð p. 19
AX2040/2070
8.8.324V auxiliary supply (X4)
—Electrically isolated, external 24VDC supply, e.g. with insulating transformer
—Required current rating ð p. 18
—Integrated EMI filter for the 24V auxiliary supply
AX2040/2070
8.8.4DC bus link (X0)
Can be connected in parallel, thanks to patented circuit to distribute the regen power among all the
amplifiers connected to the same DC bus link circuit. (Connection example ð p. 89).
Only servo amplifiers with mains supply from the same mains (identical mains
supply voltage) may be connected by the DC bus link.
The sum of the rated currents for all of the servo amplifiers connected in parallel
to an AX2040/2070 must not exceed 300A.
Use unshielded single cores (>=10mm²) with a max. length of 500 mm. Use
shielded cables for longer lengths.
AX2040/2070 Product Manual47
Electrical Installation
06/2007BECKHOFF
8.9Motor connection with brake (X0, X4)
Cable cross section see motor documentation.
AX2040/2070
8.10External regen resistor (X0)
Fusing and regen resistor provided by the user
AX2040/2070
48AX2040/2070 Product Manual
BECKHOFF
8.11Feedback
Every closed servo system will normally require at least one feedback device for sending actual
values from the motor to the servo drive. Depending on the type of feedback device used, informa
tion will be fed back to the servo amplifier using digital or analog means.
06/2007Electrical Installation
-
AX2040/2070 supports the most common types of feedback device whose functions must be assig
ned with the parameters
FBTYPE(screen page FEEDBACK), primary Feedback
EXTPOS(screen page POSITION), secondary Feedback
GEARMODE(screen page GEARING), secondary Feedback
in the setup software. Scaling and other settings must always be made here.
ConfigurationLocationASCII Parameter
One Feedback
Two Feedbacks
For a detailed description of the ASCII parameters, please refer to the online help of the setup soft
ware.
The table below provides an overview of the supported feedback types, their corresponding para
meters and a reference to the relevant connection diagram in each case. On each of these, the pin
assignment shown on the encoder side relates to the BECKHOFF motors.
Hints for combining primary with secondary feedback systems for position
control/electr. gearing can be found from page 56.
AX2040/2070 Product Manual49
Electrical Installation
8.11.1Resolver (X2)
Connection of a Resolver (2 to 36-poles) as a feedback system. The thermostat contact in the
motor is connected via the resolver cable to the AX20 and evaluated there.
If cable lengths of more than 100 m are planned, please contact our customer service .
FBTYPE 0, 3
06/2007BECKHOFF
AX2040/2070
50AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.11.2Sine encoder with BISS (X1)
Wiring of a single-turn or multi-turn sine-cosine encoder with BISS interface as a feedback system
(firmware revision from 6.68). During start-up of the servo amplifier the parameters stored in the
encoder eeprom are uploaded, after that phase only the sine/cosine signals are used.
The thermostat contact in the motor is connected via the encoder cable to X1 and evaluated there.
All signals are connected using our pre-assembled encoder connection cable.
If cable lengths of more than 50m are planned, please consult our customer service.
Frequency limit (sin, cos): 250 kHz
FBTYPE 20
AX2040/2070
AX2040/2070 Product Manual51
Electrical Installation
06/2007BECKHOFF
8.11.3Sine Encoder with EnDat 2.1 or HIPERFACE (X1)
Connection of a single-turn or multiturn sine-cosine encoder. Preferred types are ECN1313 and
EQN1325.
The thermostat contact in the motor is connected via the resolver cable to the AX20 and evaluated
there. All signals are connected using our pre-assembled encoder connection cable.
If cable lengths of more than 50 m are planned, please consult our customer service.
Frequency limit (sin, cos): 250 kHz
Encoder with EnDat: FBTYPE 3, 4
Encoder with HIPERFACE: FBTYPE 2, 3
AX2040/2070
SubD15
17pol.round
52AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.11.4Sine Encoder without data channel (X1)
Connection of a sine-cosine encoder without data channel as feedback unit. Every time the 24V
auxiliary voltage is switched on, the amplifier needs start-up information for the position controller
(parameter value MPHASE). Depending on the feedback type either wake&shake is executed or
the value for MPHASE is read out of the amplifier's EEPROM.
The thermostat contact in the motor is connected via the encoder cable to X1 and evaluated there.
If lead lengths of more than 50 m are planned, please consult our customer service.
Frequency limit (sin, cos): 250 kHz
Encoder typeFBTYPE Remarks
SinCos 5V6MPHASE from EEPROM
SinCos 5V7MPHASE with wake & shake
Resolver+SinCos5V16Commutation with Resolver, speed&position with Encoder
Don't use this feedback type with vertical load (hanging load).
AX2040/2070
AX2040/2070 Product Manual53
Electrical Installation
06/2007BECKHOFF
8.11.5Incremental or sine encoder with hall sensors (X1)
Feedback devices (incremental or sine-cosine), which don't deliver an absolute information for com
mutation, can be used as complete feedback system combined with an additional Hall encoder. All
signals are connected to X1.
If cable lengths of more than 25 m are planned, please consult our customer service.
Frequency limit (A, B): 250 kHz
RS422 with Hall: FBTYPE 12
Encoder with Hall: FBTYPE 11
AX2040/2070
SubD15
-
54AX2040/2070 Product Manual
BECKHOFF
8.11.6Incremental Encoder (X5)
An incremental encoder can be used as standard motor feedback.
Every time the 24V auxiliary voltage is switched on, the amplifier needs start-up information for the
position controller (parameter value MPHASE). Depending on the feedback type either wake&shake
is executed or the value for MPHASE is read out of the amplifier's EEPROM.
The thermostat contact in the motor is connected to X1 (see p.52) or X2 (see p.50).
If lead lengths of more than 50 m are planned and for questions concerning the power supply of the
encoder, please consult our customer service.
AGND and DGND (connector X3) must be joined together !
Frequency limit: 1.5 MHz
Encoder typeFBTYPERemarks
RS422 5V9MPHASE from EEPROM
RS422 5V8MPHASE with wake & shake
Don't use this feedback type with vertical load (hanging load).
06/2007Electrical Installation
AX2040/2070
AX2040/2070 Product Manual55
Electrical Installation
06/2007BECKHOFF
8.12Electronic Gearing, Master-slave operation
In the case of the “electronic gearing” functionality (see setup software and description of GEAR
MODE parameter), the servo amplifier is controlled by a secondary feedback device as a slave.
It is possible to set up master/slave systems, use an external encoder as a setpoint encoder or con
nect the amplifier to a stepper motor control.
The amplifier is parameterized using the setup software (electronic gearing).
Primary Feedback: adjust on screen page "Feedback" (FBTYPE)
Secondary Feedback: adjust on screen pages "Position" and "Gearing" (EXTPOS, GEARMODE)
Master-/Slave adjustment
Master: adjust encoder emulation on screen page "ROD/SSI/Encoder" (ENCMODE)
Slave: adjust on screen pages "Position" and "Gearing" (EXTPOS, GEARMODE)
The following types of external encoder can be used:
Secondary Feedback typeConnector
Incremental Encoder 5VX5
Incremental Encoder 24VX3
Sine/Cosine EncoderX1
SSI EncoderX5
Pulse and Direction 5VX5
Pulse and Direction 24VX3
* adjustable via terminal screen of the setup software
The follwing table shows the allowed feedback combinations:
8.12.1Connection to a AX20 master, 5 V signal level (X5)
You can link several AX20 amplifiers together in master-slave operation. Up to 16 slave amplifiers
can be controlled by the master via the encoder output. The connector X5 must be used.
Frequency limit: 1.5 MHz, slew rate tv £ 0,1 µs
AX2040/2070
AX20
AGND and DGND (connector X3) must be joined together !
8.12.2Connection to incremental encoder master with 24 V signal level (X3)
This interface can be used to operate the AX2040/2070 as a slave, mastered by an encoder with 24
V signal level (master-slave operation). The digital inputs DIGITAL-IN 1 and 2 at connector X3 must
be used.
Frequency limit: 250 kHz, slew rate tv £ 0.1 µs
AX2040/2070
AGND and DGND (connector X3) must be joined together !
AX2040/2070 Product Manual57
Electrical Installation
06/2007BECKHOFF
8.12.3Connection to a sine-cosine encoder master (X1)
You can operate the AX2040/2070 as a slave, mastered by a sine-cosine encoder (master-slave
operation). The connector X1 must be used.
If cable lengths of more than 25 m are planned, please consult our customer service.
Frequency limit: 250 kHz
AX2040/2070
AGND and DGND (connector X3) must be joined together!
58AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.12.4Connection to a SSI encoder (X5)
You can set up the AX2040/2070 as a slave following a synchronous serial absolute-encoder
(master-slave operation). This application uses the SubD connector X5.
If lead lengths of more than 50 m are planned and for questions concerning the power supply of the
encoder, please consult our customer service.
Frequency limit: 1.5MHz
AX2040/2070
AGND and DGND (connector X3) must be joined together!
8.12.5Connection to stepper-motor controllers (step and direction)
This interface can be used to connect the servo amplifier to a third-party stepper-motor controller.
The parameters for the servo amplifier are set up with the aid of the setup software (electrical gearing). The number of steps can be adjusted, so that the servo amplifier can be adjusted to the
pulse-direction signals of any stepper-motor controller. Various monitoring signals can be output.
Observe the frequency limit!
Using an A quad B encoder provides better EMC noise immunity.
Speed profile and signal diagram
AX2040/2070 Product Manual59
Electrical Installation
06/2007BECKHOFF
8.12.5.1Step/Direction with 5 V signal level (X5)
This interface can be used to connect the servo amplifier to a stepper-motor controller with 5 V
signal level. The connector X5 must be used.
Frequency limit: 1.5 MHz
AGND and DGND (connector X3) must be joined together !
AX2040/2070
8.12.5.2Step/Direction with 24 V signal level (X3)
This interface can be used to connect the servo amplifier to a stepper-motor controller with 24 V
signal level. The digital inputs DIGITAL-IN 1 and 2 at connector X3 must be used.
Frequency limit: 250 kHz
AGND and DGND (connector X3) must be joined together!
AX2040/2070
60AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.13Encoder emulations
8.13.1Incremental encoder output - A quad B (X5)
The incremental-encoder interface is part of the package supplied. Select the encoder function
ROD (screen page “Encoder”). In the servo amplifier, the position of the motor shaft is calculated
from the cyclic-absolute signals of the resolver or encoder. Incremental-encoder compatible pulses
are generated from this information. Pulses are output on the SubD-connector X5 as two signals, A
and B, with 90° phase difference and a zero pulse.
The resolution (lines before quadrature) can be changed with the RESOLUTION parameter:
Encoder function
(ENCMODE)
ROD (1)
ROD interpolation (3) Encoder
You can also adjust and store the position of the zero pulse within one mechanical turn
(parameter NI-OFFSET).
Feedback systemResolutionZero position
Resolver256...4096
Encoder
256...524288
8
... 219)
(2
2
7
2
...2
TTL lines per sine line
one per revolution
(only if A=B=1)
one per revolution
(only if A=B=1)
analog pass through
from X1 to X5
The drivers are supplied from an internal supply voltage. PGND must always be
connected to the controls. The max. admissible cable length is 10 m.
Connections and signal description for incremental-encoder interface :
The count direction is upwards when the motor shaft is rotating clockwise (looking at the shaft end).
AX2040/2070
AX2040/2070 Product Manual61
Electrical Installation
8.13.2SSI output (X5)
The SSI interface (synchronous serial absolute-encoder simulation) is part of the delivered
package. Select the encoder function SSI (screen page “Encoder”). In the servo amplifier, the posi
tion of the motor shaft is calculated from the cyclically absolute signals from the resolver or encoder.
This information is used to create a position output in a format that is compatible with the standard
SSI-absolute-encoder format. 24 bits are transmitted.
SINGLE TURN selected: The upper 12 bits are fixed to ZERO, the lower 12 bits contain the posi
tion information. For 2-pole resolvers, the position value refers to the position within one turn of the
motor, for 4-pole resolvers it is within half a turn, and for 6-pole resolvers it is within a third of a turn.
Exception:
bits are set to 1 (data invalid!) until a homing run is performed.
If an encoder with a commutation track is used as the feedback unit, then the upper 12
06/2007BECKHOFF
-
-
MULTI TURN selected: The upper 12 bits contain the number of motor turns, the lower 12 bits con
tain the position information.
The signal sequence can be output in Gray code (standard) or in binary code (parameter
SSI-CODE). The servo amplifier can be adjusted to the clock frequency of your SSI-evaluation with
the SSI-CLOCK parameter (cycle time 200 kHz or 1.5 MHz and inverted).
The drivers are supplied from internal supply voltage. PGND must always be
connected.
Connection and signal description for SSI interface :
The count direction is upwards when the motor shaft is rotating clockwise (looking at the shaft end).
AX2040/2070
-
62AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.14Digital and analog inputs and outputs
8.14.1Analog inputs (X3)
The servo amplifier is equipped with two differential inputs for analog setpoints which are
programmable. AGND (X3/1) must always be joined to the CNC-GND of the controls as a ground
reference.
Technical characteristics
—Differential-input voltage max. ± 10 V
—Resolution 1.25 mV
—Ground reference : AGND, terminal X3/1
—Input resistance 20 kW
—Common-mode voltage range for both inputs ± 10 V
—Update rate 62.5 µs
AX2040/2070
Input Analog-In1 (terminals X3/4-5)
Differential input voltage max. ± 10 V, resolution 14-bit, scalable
Standard setting : speed setpoint
Input Analog-In2 (terminals X3/6-7)
Differential input voltage max. ± 10 V, resolution 12-bit, scalable
Standard setting : torque setpoint
Application examples for setpoint input Analog-In2:
—adjustable external current limit
—reduced-sensitivity input for setting-up/jog operation
—pre-control / override
Fixing the direction of rotation
Standard setting : clockwise rotation of the motor shaft (looking at the shaft end)
—Positive voltage between terminal X3/4 (+ ) and terminal X3/5(-)or
—Positive voltage between terminal X3/6 (+ ) and terminal X3/7(-)
To reverse the direction of rotation, swap the connections to terminals X3/4-5 and. X3/6-7 or
change the ROT. DIRECTION parameter in the “Speed controller” screen.
AX2040/2070 Product Manual63
Electrical Installation
8.14.2Analog outputs (X3)
Technical characteristics
—Reference ground is analog-GND (AGND, terminal X3/1 and X3/10)
—Output resistance : 2.2 kW
—Output voltage ±10 V
—Resolution : 10 bit.
—Update rate 62.5 µs
06/2007BECKHOFF
AX2040/2070
Programmable analog outputs Analog-Out 1 / Analog-Out 2
The terminals X3/8 (Analog-Out 1) or X3/9 (Analog-Out 2) can have the following analog signals
assigned to them:
Standard setting :
Analog-Out 1 : Tachometer voltage n
The output delivers ±10 V at the preset limit speed.
Analog-Out 2 : Current actual value I
The output delivers ± 10 V at the preset peak current (effective r.m.s. value).
You can use the terminals X3/8 (Analog-Out 1) or X3/9 (Analog-Out 2) to output converted analog
values for digital measurements which are contained in the servo amplifier.
You can find a list of pre-programmed functions on the "analog I/O" screen of our setup software.
act
act
(speed)
(torque)
64AX2040/2070 Product Manual
BECKHOFF
8.14.3Digital inputs (X3)
All digital inputs are electrically isolated through optocouplers.
Technical characteristics
—Reference ground is Digital-GND (DGND, terminal X3/18)
—Inputs at X3 meet PLC standards (IEC 61131-2 Typ 1)
—High: 11...30 V / 2...11 mA, Low -3...+5V/<1mA
—Update rate: 250 µs
AX2040/2070
06/2007Electrical Installation
ENABLE input
The output stage of the servo amplifier is activated by the enable signal
(terminal X3/15, input 24 V, active-high).
In the inhibited state (low signal) the motor which is attached does not have any torque.
Programmable digital inputs :
You can use the digital inputs PSTOP / NSTOP / DIGITAL-IN1 and DIGITAL-IN2 to initiate
preprogrammed functions that are stored in the servo amplifier.
You can find a list of pre-programmed functions on the "digital I/O" screen of our setup software.
If an input is freshly assigned to a pre-programmed function, then the data set must be stored in the
EEPROM of the servo amplifier, and the 24 V auxiliary supply of the servo amplifier must be swit
ched off and on again (to reset the amplifier software).
Limit-switches PSTOP / NSTOP
Terminals X3/13 and X3/14 are normally programmed for the connection of limit switches. If these
inputs are not needed for the connection of limit switches, then they are programmable for other
input functions.
Limit-switch positive/negative (PSTOP / NSTOP, terminals X3/13 and X3/14), high level in normal
operation (fail-safe for a cable break).
A low signal (open) inhibits the corresponding direction of rotation, the ramp function remains
effective.
DIGITAL-IN 1 / DIGITAL-IN 2
The digital inputs on terminals X3/11 (DIGITAL-IN 1) or terminal X3/12 (DIGITAL-IN 2) can be logi
cally combined in a pre-programmable function.
-
-
AX2040/2070 Product Manual65
Electrical Installation
8.14.4Digital outputs (X3)
Technical characteristics
—Reference ground is digital-GND (DGND, terminal X3/18)
—All digital outputs are floating
—DIGITAL-OUT1 and 2:Open-collector, max. 30 VDC, 10 mA
BTB/RTO:Relay output, max. 30 VDC or 42 VAC, 0.5 A
—Update rate:250 µs
AX2040/2070
06/2007BECKHOFF
Ready-to-operate contact BTB/RTO
Operational readiness (terminals X3/2 and X3/3 ) is signalled by a floating relay contact.
The contact is closed when the servo amplifier is ready for operation, the signal is not influenced
by the enable signal, the I²t- limit, or the regen threshold.
All faults cause the BTB/RTO contact to open and the switch-off of the output
stage (if the BTB contact is open, the output stage is disabled -> no power). A list
of the error messages can be found on page 92.
Programmable digital outputs DIGITAL-OUT1/2:
You can use the digital outputs DIGITAL-OUT1 (terminal X3/16) and DIGITAL-OUT2 (terminal
X3/17) to outputs messages from pre-programmed functions that are stored in the servo amplifier.
You can find a list of pre-programmed functions on the "digital I/O" screen of our setup software.
If an input is freshly assigned to a pre-programmed function, then the data set must be stored in the
EEPROM of the servo amplifier, and the 24 V auxiliary supply of the servo amplifier must be swit
ched off and on again (to reset the amplifier software).
Evaluate the outputs via inverting interface relays (see connection diagram), for example
Phönix DEK-REL-24/I/1 (turn-on delay 6 ms, turn-off delay 16ms).
-
The described logic in the online help of the setup software refers to the output of
the inverting interface relays. Consider the delay of the applied relay !
66AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.15RS232 interface, PC connection (X6)
The setting of the operating, position control, and motion-block parameters, can be carried out on
an ordinary commercial PC.
Connect the PC interface (X6) of the servo amplifier while the supply to the equipment is swit
ched off via a normal commercial 3-core null-modem cable to a serial interface on the PC.
Do not use a null-modem link cable!
The interface is electrically isolated through an optocoupler, and is at the same potential as the
CANopen interface.
The interface is selected and set up in the setup software.
Further notes can be found on page 76.
With the optional expansion card -2CAN- the two interfaces for RS232 and CAN, which otherwise
use the same connector X6, are separated onto two connectors (ð p. 106).
AX2040/2070
-
Interface cable between the PC and servo amplifiers of the
(View : looking at the face of the built-in SubD connectors, this corresponds to the solder side of the
SubD sockets on the cable)
AX2040/2070 series:
AX2040/2070 Product Manual67
Electrical Installation
8.16CANopen interface (X6)
The interface for connection to the CAN bus (default 500 kBaud). The integrated profile is based on
the communication profile CANopen DS301 and the drive profile DSP402. The following functions
are available in connection with the integrated position controller:
Jogging with variable speed, reference traverse (zeroing), start motion task, start direct task, digital
setpoint provision, data transmission functions and many others.
Detailed information can be found in the CANopen manual. The interface is electrically isolated by
optocouplers, and is at the same potential as the RS232 interface. The analog setpoint inputs can
still be used.
With the optional expansion card -2CAN- the two interfaces for RS232 and CAN, which otherwise
use the same connector X6, are separated onto two connectors (ð p. 106).
AGND and DGND (connector X3) must be joined together !
AX2040/2070
06/2007BECKHOFF
CAN bus cable
To meet ISO 11898 you should use a bus cable with a characteristic impedance of 120 W. The
maximum usable cable length for reliable communication decreases with increasing transmission
speed. As a guide, you can use the following values which we have measured, but they are not to
be taken as assured limits:
Cable data:Characteristic impedance100-120 W
Cable capacitymax. 60 nF/km
Lead resistance (loop)159.8 W/km
Cable length, depending on the transmission rate
Transmission rate / kbaudmax. cable length / m
100020
50070
250115
Lower cable capacity (max. 30 nF/km) and lower lead resistance
(loop, 115 W/km) make it possible to achieve greater distances.
(Characteristic impedance 150 ± 5 WÞterminating resistor 150 ± 5 W).
For EMC reasons, the SubD connector housing must fulfil the following conditions:
—metal or metallized housing
—provision for cable shielding connection in housing, large-area connection
68AX2040/2070 Product Manual
BECKHOFF
8.17Restart lock -AS-
A frequently required application task is the protection of personnel against the restarting of drives.
This can not be achieved by an electronic inhibit, but must be implemented with mechanical ele
ments (positively driven relay contacts).
To get round this problem, up to now either the main contactor in the mains supply line was swit
ched off, or another contactor was used to disconnect the motor from the servo amplifier.
The disadvantages of this method are :
—the DC bus link has to be charged up again at restart
—wear on the contacts of the contactors, caused by switching under load
—extensive wiring required, with additional switching components
The restart lock -AS- avoids these disadvantages. A safety relay in the servo amplifier is activated
either by the PLC or manually. Positively driven contacts provide a safe disconnection of the ampli
fier, the setpoint input of the servo amplifier is inhibited, and a signal is sent to the safety circuit.
The suggested circuits (ð p. 73) fulfills safety category 1 (EN 954-1) or category 3 with additional
safety relay (e.g. PNOZ of PILZ company).
Advantages of the restart lock -AS- :
—the DC bus link remains charged up, since the mains supply line remains active
—only low voltages are switched, so there is no contact wear
—very little wiring is required
—the functionality and the personnel safety when using the circuit recommendations in
this documentation have been approved by the Trade Liability Association.
06/2007Electrical Installation
-
-
-
Moving single axis-groups in setting-up operation
In setting-up operation, people will frequently be within the danger zone of the machinery. Axes will
normally be moved under the control of permission switches. An additional switch-off of the unused
axes, by means of the restart lock, increases the safety margin and avoids the repeated switching
of main contactors or motor contactors.
Switching off grouped axes with separate working areas
Even when several AX2040/2070 are operating off a common mains supply and DC bus link, it is
possible to set up groups for separate working areas. These groups can then be switched off separately for personnel safety.
8.17.1Safety instructions
l
Observe the chapter "use as directed" for the restart lock -AS- (ð p. 70)
l
The monitoring contacts (KSO1/2) for each amplifier must be looped into the control
circuit. This is vital, so that a malfunction of the internal safety relay or a cable break
can be recognized.
l
If the restart lock -AS- is automatically activated by a control system (KSI1/2), then
make sure that the output of the control is monitored for possible malfunction. This
can be used to prevent a faulty output from activating the restart lock -AS- while the
motor is running.
l
Keep to the following functional sequence when the restart lock -AS- is used :
1.Brake the drive in a controlled manner (speed setpoint = 0V)
3.If there is a suspended load, block the drive mechanically
4.Activate the restart lock -AS-
AX2040/2070 Product Manual69
Electrical Installation
8.17.2Use as directed
06/2007BECKHOFF
The restart lock -AS- is exclusively intended to provide safety for personnel, by preventing the res
tart of a system. To achieve this personnel safety, the wiring of the safety circuits must meet the
safety requirements of EN60204, EN12100 and EN 954-1..
The -AS- restart lock must only be activated,
—when the motor is no longer rotating (setpoint = 0V, speed = 0rpm, enable = 0V).
Drives with a suspended load must have an additional safe mechanical blocking
(e.g. by a motor-holding brake).
—when the monitoring contacts (KSO1/2) for all servo amplifiers are wired into
the control signal loop.
The -AS- restart lock may only be controlled by a CNC if the control of the internal safety relay is
arranged for redundant monitoring.
The -AS- restart lock must not be used if the drive is to be made inactive for the following reasons :
1.- cleaning, maintenance and repair operations
- long inoperative periods
In such cases, the entire system should be disconnected from the supply by the personnel,
and secured (main switch).
2.- emergency-stop situations
In an emergency-stop situation, the main contactor is switched off (by the emergency-stop
button).
8.17.3Block diagram
-
70AX2040/2070 Product Manual
BECKHOFF
8.17.4Functional description
The connector (X10) is mounted on the front panel of the AX2040/2070.The coil connections and a
make (n.o.) contact of a safety relay are made available through 4 terminals on this connector.
06/2007Electrical Installation
The 24VDC safety relay in the servo amplifier (approved) is controlled externally. All the relay con
tacts have positive action.
Two contacts switch off the driver supply of the output stage in the servo amplifier, and short the
internal setpoint signal to AGND (0 V).
The make (n.o.) contact used for monitoring is looped into the control circuit.
If the safety relay is not energized, then the monitoring contact is open and the servo amplifier is
ready for operation.
If the drive is electronically braked, the servo amplifier is disabled and the motor-holding brake is
on, then the safety relay is energized (manually or by the controls).
The supply voltage for the driver circuit of the output stage is switched off in a safe manner, the
internal setpoint is shorted to 0V, and the monitoring contact bridges the safety logic in the control
circuit of the system (monitoring of protective doors etc.)
Even if the output stage or driver is destroyed, it is impossible to start the motor.
If the safety relay itself is faulty, then the monitoring contact cannot bridge the safety logic of the
system. Opening the protective devices will then switch off the system.
8.17.5Signal diagram (sequence)
-
AX2040/2070 Product Manual71
Electrical Installation
06/2007BECKHOFF
8.17.6Functional test
The functioning of the restart lock must be tested during setup, after every
alteration in the wiring of the system, or after exchanging one or more components
of the system.
1.Stop all drives, with setpoint 0V, disable drives, mechanically block any suspended loads
2.Activate the restart lock -AS-.
3.Open protective screens (but do not enter hazardous area)
4.Pull off the X10 connector from an amplifier: the mains contactor must drop out
5.Reconnect X10. Switch on mains contactor again.
6.Repeat steps 4 and 5 for each individual servo amplifier.
8.17.7Connection diagram (principle)
AX2040/2070
Application examples for category 1 see chapters 8.17.8.
72AX2040/2070 Product Manual
BECKHOFF
06/2007Electrical Installation
8.17.8Application example category 1 according to EN 954-1
8.17.8.1Control circuit
8.17.8.2Mains supply circuit
AX2040/2070 Product Manual73
Electrical Installation
06/2007BECKHOFF
8.17.9Application example category 3 according to EN 954-1
Please contact our customer service.
74AX2040/2070 Product Manual
BECKHOFF
9Setup
9.1Important notes
Only professional personnel with extensive knowledge in the fields of electrical/
drive technology are allowed to setup the servo amplifier.
The setup procedure is described as an example. Depending on the application,
a different procedure may be sensible or necessary. In multi-axis systems, setup each
servo amplifier individually.
The manufacturer of the machine must generate a hazard analysis for the machine,
and take appropriate measures to ensure that unforeseen movements cannot
cause injury or damage to any person or property.
Check that all live connecting elements are protected from accidental contact.
Deadly voltages can be present, up to 900V.
Never disconnect any of the electrical connections to the servo amplifier while it is
live. Capacitors can still have residual charges with dangerous levels up to 300
seconds after switching off the supply power.
Heat sinks of the amplifier can reach a temperature of up to 80°C (176°F) in
operation. Check (measure) the heat sink temperature. Wait until the heat sink has
cooled down below 40°C (104°F) before touching it.
06/2007Setup
If the servo amplifier has been stored for longer than 1 year, then the DC bus link
capacitors will have to be re-formed.
To do this, disconnect all the electrical connections.
Supply the servo amplifier for about 30 min. from single-phase 230VAC to the
terminals L1 / L2. This will re-form the capacitors.
Further setup information:
The adaptation of parameters and the effects on the control loop behavior are
described in the online help.
The setup of the expansion card (if present) is described in the corresponding
manual on the CD-ROM.
We can provide further know-how through training courses (on request).
AX2040/2070 Product Manual75
Setup
9.2Setup software
9.2.1General
This chapter describes the installation of the setup software for the AX2040/2070 digital servo
amplifiers.
We offer training and familiarisation courses on request.
9.2.1.1Use as directed
The setup software is intended to be used for setting up and storing the operating parameters for
the AX2040/2070 series of servo amplifiers. The attached servo amplifier can be setup with the
assistance of the software - during this process the drive can be controlled directly by the service
functions.
Only professional personnel who have the relevant expertise described on page 7
are permitted to carry out online parameter setting for a drive which is running.
Sets of data which are stored on data media are not safe against unintended
alteration by other persons. After loading a set of data you must therefore check all
parameters thoroughly before enabling the servo amplifier.
06/2007BECKHOFF
9.2.1.2Software description
The servo amplifiers must be adapted to the requirements of your installation. Usually you will not
have to carry out this parameter setting yourself on the amplifier, but on a PC, with the assistance of
the setup software. The PC is connected to the servo amplifier by a null-modem cable (ð p. 67).
The setup software provides the communication between AX2040/2070 and the PC.
You will find the setup software on the accompanying CD-ROM and at our web site in the download
area.
With very little effort you can alter parameters and instantly observe the effect on the drive, since
there is a continuous (online) connection to the amplifier.
Simultaneously, important actual values are read out from the amplifier and displayed on the PC
monitor (oscilloscope function).
Any interface modules (expansion cards) which may be built into the amplifier are automatically
recognized, and the additional parameters which are required for position control or motion-block
definition are made available.
Sets of data can be stored on data media (archived) and loaded again. Sets of data which are
stored on data media can be printed.
We supply you with motor-specific default sets of data for the most common combinations of servo
amplifier and motor. In most applications you will be able to use these default values to get your
drive running without any problems.
An extensive online help with integrated description of all variables and functions supports you in
each situation.
76AX2040/2070 Product Manual
BECKHOFF
9.2.1.3Hardware requirements
The PC interface (X6, RS232) of the servo amplifier is connected to the serial interface of the PC by
a null-modem cable (not a null-modem link cable !)(ð p. 67).
Connect / disconnect the interface cable only when the supply is switched off for
both the PC and the servo amplifier.
The interface in the servo amplifier is electrically isolated by an optocoupler, and is at the same
potential as the CANopen interface.
Minimum requirements for the PC:
Processor:Pentium I or higher
Operating system:WINDOWS 95(c) / 98 / 2000 / ME / NT4.0 / XP
Graphics adapter:Windows compatible, color
Drives:hard disk with at least 10 MB free space
Main memory:at least 8MB
Interface:one free serial interface (COM1...COM10)
9.2.1.4Operating systems
WINDOWS 95(c) / 98 / 2000 / ME / NT / XP
06/2007Setup
CD-ROM drive
DRIVE.EXE is executable under WINDOWS 95(c) / 98 / 2000 / ME / NT 4.0 / XP.
The HTML help system is not available under WINDOWS 95a and 95b.
WINDOWS FOR WORKGROUPS 3.xx, DOS, OS2
DRIVE.EXE is not executable under WINDOWS 3.xx, DOS and OS2.
In emergency, operation is possible through an ASCII terminal emulation (without user-interface).
Interface settings : 9600 bps, no parity, no handshake
Unix, Linux
The software function has not been tested running within Unix or Linux.
9.2.2Installation under WINDOWS 95 / 98 / 2000 / ME / NT / XP
The CD-ROM includes an installation program for the setup software.
Installation
Autostart function activated:
Insert the CD-ROM into a free drive. A window with the start screen opens. There you find a link to
the setup software DRIVE.EXE. Click it and follow the instructions.
Autostart function deactivated:
Insert the CD-ROM into a free drive. Click on START (task bar), then on Run. Enter the program
call: x:\index.htm (x = correct CD drive letter).
Click OK and proceed as described above.
Connection to the serial interface of the PC
Connect the interface cable to a serial interface on your PC and the PC interface (X6) of the
AX2040/2070 (ð p. 67).
AX2040/2070 Product Manual77
Setup
06/2007BECKHOFF
9.3Quickstart Guide
9.3.1Preparation
9.3.1.1Unpacking, Mounting and Wiring the Servo Amplifier
1. Unpack servo amplifier and accessories
2. Observe safety instructions in the manuals
3. Mount the servo amplifier as described in chapter 7.3
4. Wire the servo amplifier as described in chapter 8.3 or apply the minimum wiring for drive testing
as described in chapter 9.3.1.3
5. Install the software as described in chapter 9.2
9.3.1.2Documents
You need access to these documents (located on the product CD-ROM, you can download the
latest editions from our website):
Product Manual (this manual)
l
CANopen Communication Profile Manual
l
Depending on the installed expansion card you need one of these documents:
PROFIBUS DP Communication Profile Manual
l
DeviceNet Communication Profile Manual
l
l
SERCOS Communication Profile Manual
l
EtherCat Communication Profile Manual (in process)
You need Acrobat Reader to read the PDFs, an installation link is on every screen of the product
CD-ROM.
78AX2040/2070 Product Manual
BECKHOFF
06/2007Setup
9.3.1.3Minimum Wiring for Drive Test
This wiring does not fulfill any requirements to safety or functionality of your
application, it just shows the required wiring for drive testing without load.
PC
2
X3
RES
CAN
Motor-Feedback
ENC
3
Power ON
24V DC
Enable
15
18
24V ON
X4
+
-
Power
3
5
ChokeFilter
4
Motor-Power
Motor
Brake Res.
AX2040/2070 Product Manual79
Setup
9.3.2Connect
Connect the interface cable to a serial interface on your PC and to the serial interface X6 of
l
the servo amplifier. USB to serial converter can be used optionally.
Switch on the 24 V power supply for the servo amplifier.
l
Wait about 30 seconds, until the front display of the servo amplifier displays the current
l
classe (e.g.for 40 amps). If the power supply voltage is switched on, too, a leading
P is displayed (e.g.for Power, 40 amps).
If a fault code () or a warning () or a status message (./_ / E/S) appears
in the display, you will find the description on page 92ff. If there is fault, fix the
problem.
06/2007BECKHOFF
Double-Click the DRIVE.EXE icon on your Windows desktop to start the software.
You can work offline or online with .
Work ONLINE now. Select the interface where the servo am
plifier is connected to.
-
The software tries to communicate with the
drive and to upload the parameters. If it's
not successful, you receive this error mes
sage.
- wrong interface chosen
- wrong connector chosen at the servo amplifier
Frequent causes:
Click OK to remove the error message. Detect and remove the error source. Restart the software.
- interface is used by another software
- 24 V auxiliary voltage for the servo amplifier not working
- interface cable broken or wrong wiring
-
80AX2040/2070 Product Manual
BECKHOFF
If communication works, parameters are transmitted from the servoamplifier to the computer.
Then you see the start screen.
9.3.3Important Screen Elements
06/2007Setup
Make sure, that the amplifier is
disabled (Input HW-Enable con
nector X3 pin 15 must be
0 V or open)!
-
Help Function
The Online-Help gives detailed information to all parameters the servo amplifier can work with.
Key F1
Menu Bar ? or
Online HTML Help
Tool Bar
Save to EEPROM,
required if you changed parameters.
Reset (coldstart),
required if you changed important configuration parameters.
Starts Online Help for the actual screen page.
Starts Online Help with table of contents.
Operation Mode, use Digital Velocity mode for drive testing.
Disable and Enable of the amplifier's output stage via software.
Status Bar
AX2040/2070 Product Manual81
Setup
9.3.4Basic Setup
On the start screen click "Basic Setup" button.
Regen Resistor: Select "external" regen resistor
06/2007BECKHOFF
max.Regen Power: Fill in the power of the connected regen resistor.
max. Mains Voltage: Select the nominal mains AC voltage
Mains Phase Missing: You can select either warning "n05" or error "F19" in case of phase loss.
The setting "F19" disables the output stage, "n05" is just a message.
Units: Acceleration, Velocity, Position
Select usable units for your application referring to the moved load.
Leave all other fields unchanged.
Click OK. On the start screen click "Motor" button.
82AX2040/2070 Product Manual
BECKHOFF
9.3.5Motor (synchronous)
Press function key F12 (SW disable) before changing motor parameters.
Motor Type: Select Synchronous Motor. If you use a linear motor or an induction motor, please
contact our support department.
Number-Name: Click the list to start uploading the motor parameter table, which is stored in the
servo amplifier. Search and select the connected motor. If your motor is not listed, please contact
our support department.
06/2007Setup
Leave all other fields unchanged.
Click OK.
If your motor has a built-in brake, click Yes,
otherwise "No".
If Software Enable is active, a warning appe
ars. You can proceed, but after the amplifier is
restarted, you must check whether the holding
brake configuration is correct.
Click OK.
Parameters are uploaded to the amplifier's
RAM now (takes some seconds). When this is
done, you have to accept the changed confi
guration with "Yes" or to discard the changes
in the appearing screen.
If you click "Yes", the parameters are saved in
the EEPROM and the amplifier makes a cold
start (reset). This takes some seconds.
-
-
-
On the start screen, click "Feedback" button.
AX2040/2070 Product Manual83
Setup
9.3.6Feedback
06/2007BECKHOFF
Press function key F12 (disable) before chan
ging feedback parameters.
Feedback Type:
Select the feedback type used.
Leave all other fields unchanged.
If Software Enable is active, a warning appears.
The configuration change cannot be performed.
Click OK on the warnings, press F12 (SW disab
le) and start the Feedback procedure again.
If everything was ok, the same procedure (para
meter upload) that has been described for the
motor selection starts.
If you click "Yes", the parameters are saved in
the EEPROM and the amplifier makes a coldstart (reset). This takes some seconds.
-
-
-
84AX2040/2070 Product Manual
BECKHOFF
06/2007Setup
9.3.7Save Parameters and Restart
You are going to finish setup and you have changed several basic parameters. Depending on the
parameters you changed, two possible reactions can occur:
Configuration parameters changed
A warning appears, that you have to restart the amplifier. This is called "coldstart". Click "YES". The
parameters are saved to the amplifier's EEPROM automatically and a reset command restarts the
amplifier (takes a few seconds). For example, this happens after motor or feedback selection.
Other parameters changed
No warning appears. Parameters are saved in the volatile RAM only. Save the parameters to the
EEPROM of the servo amplifier manually by clicking the symbolin the tool bar. A coldstart
of the amplifier is not necessary.
Reset the amplifier
You can reset the amplifier manually (e.g. in case of an error). Click the icon.
AX2040/2070 Product Manual85
Setup
06/2007BECKHOFF
9.3.8Jogging the Motor (Speed Control)
Be aware that the actual position of the load permits the subsequent moving
operations. The axis could move to the hardware limit-switch or the mechanical
stop. Make sure that a jerk or a fast acceleration of the load cannot cause any
damage.
Switch on the power supply for the drive.
l
Hardware-Enable: +24 VDC to Enable [connector X3 pin 15].
l
Software-Enable: Click the "Enable" buttonon the start screen or use key
l
combination Shift+F12. Now, the front display shows an E and the current rating (e.g.
for Enable, 40 amps)
Click the icon "Oscilloscope"
l
l
Select Service-Mode "Speed F6", then click "Parameter" button
l
Enter a safe speed. The sign defines the direction of movement.
Observe the "safe reduced speed" requirements for your application!
l
Click OK.
l
Start the service function ("Start" button or press F6).
Click OK on the warning notice.
Opmode is switched to "0" and the output stage is enabled automatically. The symbol's color
changes to green as long as the function is active.
l
The function is active until you click the "Stop" button or press F9.
l
The output stage can be disabled by pressing function key F12.
86AX2040/2070 Product Manual
BECKHOFF
9.3.9Status
Actual warnings and errors are listed on the Status screen, which can be accessed on the start
screen by clicking the "Status" button. This button monitors the current status of the amplifier and
can appear with different text.
06/2007Setup
The Reset button can be used to clear some actual error messages. A description of errors/warnings can be found on page 92.
Now you have setup and tested the basic functions of the drive successfully.
9.3.10Monitor
9.3.11Additional Setup Parameters
Detailed information on all setup functions can be found in the Online Help systemand and the inte
grated command reference.
Click the icon "Monitor"
The Monitor screen shows all
important electrical and me
chanical actual values
-
-
AX2040/2070 Product Manual87
Setup
9.4Multi-axis system
Using a special multilink cable, you can connect up to six servo amplifiers together and to your PC :
Cable type -SR6Y- (for 4 amplifiers) or -SR6Y6- (for 6 amplifiers).
06/2007BECKHOFF
X6
PC/CAN
PC
COMx
RS232
Baud rates are the same for all amplifiers,
see table below
With the PC connected to just one servo amplifier you can now use the setup software to select all
amplifiers through the preset station addresses and set up the parameters.
Add.:01
Cable -SR6Y-
9.4.1Node address for CAN-bus
During setup it makes sense to preset the station addresses for the individual amplifiers and the
baud rate for communication by means of the keypad on the front panel (ð p. 91).
Add.:02
Add.:03
Add.:04
9.4.2Baud rate for CAN-bus
After changing the station address and baud rate you must turn the 24V auxiliary
supply of the servo amplifier off and on again.
Coding of the baud rate in the LED display :
CodingBaud rate in kbit/sCodingBaud rate in kbit/s
0105250
1206333
2507500
31008666
41259800
101000
88AX2040/2070 Product Manual
BECKHOFF
06/2007Setup
9.4.3Example of connections for a multi-axis system
Reference Safety Instructions (ð p.9) and
Use As Directed (ð p.10) !
AX2040/2070
AX2040/2070
AX2040/2070 Product Manual89
Setup
06/2007BECKHOFF
9.5Key operation / LED display
In this chapter the two possible operation menus and the use of the keys in the front panel are
shown. Normally, the AX2040/2070 only places the standard menu at your disposal. If you want to
attend the amplifier via the detailed menu, you must keep the right key pressed while switching on
the 24V-supply.
9.5.1Key operation
The two keys can be used to perform the following functions:
Key symbol Functions
press once : go up one menu item, increase number by one
press twice in rapid succession : increase number by ten
press once : go down one menu item, decrease number by one
press twice in rapid succession : decrease number by ten
press and hold right key, then press left key as well :
enters a number, return function
9.5.2Status display
90AX2040/2070 Product Manual
BECKHOFF
9.5.3Standard menu structure
9.5.4Extended menu structure
Keep the right key pressed while switching on the 24V-supply.
06/2007Setup
see p.88
the entry will be stored automatically,
when you exit the input field.
see p.88
see p.88
AX2040/2070 Product Manual91
Setup
9.6Error messages
Errors which occur are shown in coded form by an error number in the LED display on the front
panel. All error messages result in the BTB/RTO contact being opened, and the output stage of the
amplifier being switched off (motor loses all torque). If a motor-holding brake is installed, it will be
activated.
NumberDesignationExplanation
E/S/A/P
...
-
F01*
F02*
F03*
F04
F05*
F06
F07
F08*
F09
F10
F11
F12
F13*
F14
F15
F16*
F17
F18
F19*
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30
F31
F32
* = These error messages can be cancelled by the ASCII command CLRFAULT, without executing a reset. If
only these errors are present, and the RESET button or the I/O-function RESET is used, the CLRFAULT com
mand is also all that is carried out.
Status MessagesStatus messages, no error, see p. 90
Status MessageUpdating the startup configuration
Status MessageProgramming mode
Heat sink temperature
Overvoltage
Following errorMessage from the position controller
FeedbackCable break, short-circuit, short to ground
Undervoltage
Motor temperature
Internal voltage supply Internal amplifier supply voltages are out of tolerance
OverspeedMotor runs away, speed is too high
EEPROMChecksum error
Flash-EPROMChecksum error
BrakeCable break, short-circuit, short to ground
Motor phaseMotor phase missing (cable break or similar)
Internal temperatureInternal temperature too high
Output stageFault in the power output stage
I²t max.I²t maximum value exceeded
Supply BTB/RTO2 or 3 phases missing in the mains supply feed
A/D converter
RegenRegen circuit faulty or incorrect setting
Supply phase
Slot faultSlot error (hardware fault on expansion card)
Handling errorSoftware error on the expansion card
Earth short circuitShort-circuit between motor phase and ground
CAN-bus offSevere CAN bus communication error
WarningWarning is displayed as fault
Commutation errorCommutation error
Limit switchHoming error (machine has driven onto hardware limit switch)
AS
External Trajectory
Slot Faultdepends on expansion card, see online help
Emergency timeoutTimeout emergency stop
MacroMacro program error
System Errorsystem software not responding correctly
06/2007BECKHOFF
Heat sink temperature too high
limit is set by manufacturer to 80°
Overvoltage in DC bus link
limit depends on the electrical supply voltage
Undervoltage in DC bus link
limit is set by manufacturer to 100V
Motor temperature too high or temp. sensor defect
limit is set by manufacturer to 145°C
Error in the analog-digital conversion, normally caused by extreme electromagnetic interferences.
A phase is missing in the mains supply power feed
(can be switched off for 2-phase operation)
Operational error with -AS- , input for AS-Enable and ENAB
LE have been set at the same time
External position profile generator created a step, that excee
ded the maximum value
-
-
-
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter ERRCODE. Hints for removal can be found in section
"Trouble-Shooting" of the online help.
92AX2040/2070 Product Manual
BECKHOFF
9.7Warning messages
06/2007Setup
Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO con
tact remains closed), are indicated in the LED display on the front panel by a coded warning
number.
* = These warning messages lead to a controlled shut-down of the drive (braking with the emergency ramp)
Status MessagesStatus messages, no error, see p. 90
Status MessageUpdating the startup configuration
Status MessageProgramming mode
I²tI²t threshold exceeded
Regen powerReached preset regen power limit
S_faultExceeded preset following error limit
Response monitoringResponse monitoring (fieldbus) has been activated
Supply phaseMains supply phase missing
SW limit switch 1Underrun software limit switch 1
SW limit switch 2Overrun software limit switch 2
Motion task errorA faulty motion task was started
No reference pointNo reference point (Home) set at start of motion task
PSTOPPSTOP limit-switch activated
NSTOPNSTOP limit-switch activated
Motor default values
loaded
Slot warning24V supply of the I/O expansion board is missing
SinCos feedback
Table errorFault according to speed/current table INXMODE 35
Summarized warningSummarized warning for n17 to n31
Fielbus Synchronization
Multiturn overrun
Motion task ramps are limited Range overflow on motion task data
Wrong GMT dataWrong "Graphical Motion Task" data
PLC program errorFor details see plc code
max. motor temperatur rea
ched
reservedreserved
firmware beta versionFirmware is an unreleased beta version
Only for ENDAT or HIPERFACE
discrepancy between motor number saved in the en
coder and the amplifier, motor default values loaded
SinCos commutation (wake & shake) not completed,
will be canceled when amplifier is enabled and
wake&shake carried out
The mode synchronization SYNCSRC is selected but
the drive isn’t in synchronies cycle
Using Multiturn encoder feedback, an overrun over
the maximum number of resolutions was detected
-
The user can shut down the process before the tem
perature eror will interrupt the process immediately
®
:
-
-
-
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter STATCODE. Hints for removal can be found in section
"Trouble-Shooting" of the online help.
AX2040/2070 Product Manual93
Setup
06/2007BECKHOFF
9.8Removing faults / warnings
Depending on the conditions in your installation, there may be a wide variety of reasons for the
fault. In multi-axis systems there may be further hidden causes of a fault.
Detailled hints for removal of faults can be found in the Online help chapter
"Trouble-Shooting".
Our customer service can give you further assistance with problems.
Faultpossible causes
HMI message:
communicati
on fault
— wrong cable used
— cable plugged into wrong position
-
in servo amplifier or PC
— wrong PC interface selected
— servo amplifier not enabled
— break in setpoint cable
motor does
not rotate
— motor phases swapped
— brake not released
— drive is mechanically blocked
— no. of motor poles set incorrectly
— feedback set up incorrectly
motor
oscillates
drive reports
following error
motor overheating
— gain too high (speed controller)
— shielding in feedback cable broken
— AGND not wired up
or I
—I
rms
is set to low
peak
— setpoint ramp is too long
—I
rms/Ipeak
set too high— reduce I
— Kp (speed controller) too low
— Tn (speed controller) too high
drive too soft
— PID-T2 too high
— T-Tacho too high
— Kp (speed controller) too high
drive runs
roughly
— Tn (speed controller) too low
— PID-T2 too low
— T-Tacho too low
— offset not correctly adjusted for analog
axis drifts at
setpoint = 0V
setpoint provision
— AGND not joined to the CNC-GND of
the controls
Measures to remove the cause of
the fault
— use null-modem cable
— plug cable into the correct sockets
on the servo amplifier and PC
— select correct interface
— apply enable signal
— check setpoint cable
— correct motor phase sequence
— check brake control
— check mechanism
— set no. of motor poles
— set up feedback correctly
— reduce Kp (speed controller)
— replace feedback cable
— join AGND to CNC-GND
— increase I
rms
or I
peak
(keep within motor data !)
— shorten setpoint ramp +/-
rms/Ipeak
— increase Kp (speed controller)
— use motor default value for
Tn (speed controller)
— reduce PID-T2
— reduce T-Tacho
— reduce Kp (speed controller)
— use motor default value for
Use a suitable screwdriver to unscrew
the cover of the option slot.
Take care that no small items (such
as screws) fall into the open option
slot.
l
Press the expansion card firmly into
the slot, until the front cover touches
the fixing lugs. This ensures that the
connectors make good contact.
l
Screw the screws on the front cover
into the threads in the fixing lugs.
Push the expansion card carefully
l
into the provided guide rails of the
main slot, without twisting it.
AX2040/2070 Product Manual95
Expansion Cards
06/2007BECKHOFF
10.2Expansion card -I/O-14/08-
This chapter describes the I/O-expansion card -I/O-14/08-. It only describes the additional features
that the expansion card makes available for the AX2040/2070.
If you ordered the expansion card together with the servo amplifier, then it will be delivered already
inserted into the expansion slot of the servo amplifier and screwed fast.
The -I/O-14/08- provides you with 14 additional digital inputs and 8 digital outputs. The functions of
the inputs and outputs are fixed. They are used to initiate the motion tasks that are stored in the
servo amplifier and to evaluate signals from the integrated position control in the higher-level
control.
The functions of the inputs and signal outputs correspond exactly to the functions that can be assig
ned to the digital-I/O on connector X3 of the AX2040/2070.
All inputs and outputs are electrically isolated from the servo amplifier by optocoupler.
10.2.1Front view
10.2.2Technical data
Control inputs
Signal outputs
Supply inputs, to IEC 1131
Fusing (external)
Connectors
Cables
Waiting time between 2 motion
tasks
Addressing time (min.)
Starting delay (max.)
Response time of digital outputs
-
24V / 7mA, PLC-compatible
24V / max. 500mA, PLC-compatible
24V (18 ... 36V) / 100mA plus total current of the outputs
(depends on the input wiring of the controls)
The 24VDC voltage has to be supplied by an electrically
isolated power supply, e.g. with insulating transformer.
4AT
MiniCombicon, 12-pole, coded on PIN1 and 12 respectively
Data– up to 50m long : 22 x 0.5mm², unshielded,
Supply– 2 x 1mm², check voltage drop
depends on the response time of the control system
4ms
2ms
max. 10ms
10.2.3Light emitting diodes (LEDs)
Two LEDs are mounted next to the terminals on the expansion card. The green LED signals that
the 24V auxiliary supply is available for the expansion card. The red LED signals faults in the out
puts from the expansion card (overload, short-circuit).
Polls the reference switch. If a digital input on the basic unit
is used as a reference input, then the input on the I/O expan
sion card will not be evaluated.
Clear the warning of a following error or the response moni
toring.
The following task, that is defined in the motion task by “Start
with I/O” is started. The target position of the present motion
task must be reached before the following task can be start
ed. The next motion block can also be started by an appro
-
priately configured digital input on the basic unit.
Start of the setup mode "Jog Mode" with a defined speed. Af
ter selecting the function, you can enter the speed in the au
xiliary variable “x”. The sign of the auxiliary variable defines
the direction. A rising edge starts the motion, a falling edge
cancels the motion.
-
Connector X11B
Continues the motion task that was previously interrupted.
1InMT_Restart
The motion task can also be continued by an appropriately
configured digital input on the basic unit.
Start of the motion task that has the number that is presented, bit-coded, at the digital inputs (A0 to A7).
2InStart_MT I/O
The digital function with the same name, in the basic unit,
starts the motion task with the address from the digital inputs
on the basic unit.
When the target position for a motion task has been reached
3OutInPos
(the InPosition window), this is signalled by the output of a
HIGH-signal.
A cable break will not be detected
The start of each motion task in an automatically executed
sequence of motion tasks is signalled by an inversion of the
output signal. The output produces a Low signal at the start
of the first motion task of the motion task sequence.
4Out
Next-InPos
The form of the message can be varied by using ASCII com
mands.
PosReg0Can only be adjusted by ASCII commands.
5OutFError
Following-error (low-active).
6OutPosReg1
7OutPosReg2
8OutPosReg3
The preset function of the corresponding position register is
indicated by a HIGH-signal.
9OutPosReg4
10OutPosReg5Can only be adjusted by ASCII commands.
11Supply24VDCauxiliary supply voltage
12SupplyI/O-GNDDigital-GND for the controls
-
AX2040/2070 Product Manual97
Expansion Cards
10.2.6Connection diagram
AX2040/2070
-I/O-14/08
06/2007BECKHOFF
AGND and DGND (connector X3) must be joined together !
98AX2040/2070 Product Manual
BECKHOFF
06/2007Expansion Cards
10.3Expansion cards -PROFIBUS-
This chapter describes the PROFIBUS expansion card for the AX2040/2070.
Information on the range of functions and the software protocol can be found in the manual
"Communication profile PROFIBUS DP". The PROFIBUS expansion card has two 9-pin Sub-D
sockets wired in parallel. The supply voltage for the expansion card is provided by the servo ampli
fier.
10.3.1Front view
10.3.2Connection technology
Cable selection, cable routing, shielding, bus connector, bus termination and transmission times are
described in the “Installation guidelines for PROFIBUS-DP/FMS” from PNO, the PROFIBUS User
Organization.
10.3.3Connection diagram
-
AX2040/2070
AGND and DGND (connector X3) must be joined together !
AX2040/2070 Product Manual99
Expansion Cards
06/2007BECKHOFF
10.4Expansion card -SERCOS-
This chapter describes the SERCOS expansion card for AX2040/2070.
Information on the range of functions and the software protocol can be found in the manual
"IDN Reference Guide SERCOS".
10.4.1Front view
10.4.2Light emitting diodes (LEDs)
indicates whether SERCOS telegrams are being correctly received. In the final Communi
RT
cation Phase 4 this LED should flicker, since cyclical telegrams are being received.
indicates that SERCOS telegrams are being transmitted. In the final Communication
Phase 4 this LED should flicker, since cyclical telegrams are being transmitted.
Check the stations addresses for the controls and the servo amplifier if:
TT
- the LED never lights up in SERCOS Phase 1 or
- the axis cannot be operated, although the RT LED is lighting up cyclically.
indicates that SERCOS communication is faulty or suffering from interference.
If this LED is very bright, then communication is suffering strong interference,
or is non-existent.
Check the SERCOS transmission speed for the controls and the servo amplifier
(BAUDRATE) and the fibre-optic connection.
If this LED flickers, this indicates a low level of interference for SERCOS communication,
ERR
or the optical transmitting power is not correctly adjusted to suit the length of cable.
Check the transmitting power of the (physically) previous SERCOS station.
The transmitting power of the servo amplifier can be adjusted in the setup software
DRIVE.EXE on the SERCOS screen page, by altering the parameter for
the cable length.
10.4.3Connection technology
For the fiber optic cable connection, only use SERCOS components to the SERCOS Standard
IEC 61491.
-
Receive data
The fiber optic cable carrying receive data for the drive in the ring structure is connected to X13 with
an F-SMA connector.
Transmit data
Connect the fiber optic cable for the data output to X14 with an F-SMA connector.
100AX2040/2070 Product Manual