Air Purifiers
Installation Instructions
WARNING
1.High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation.
2.Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal.
CAUTION
1.To prevent component failure, do not install the air purifier on the warm air supply or in an area where the temperature may exceed 140°F. This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns.
2.Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation.
3.Do not install air purifier downstream of a UV light. UV lamps will cause degradation of the filtering media.
SPECIFICATIONS
MODEL |
1110 |
1210, 2210, 2216, 3210 |
1310, 2310, 3310 |
1410, 2410, 2416, 3410 |
1910 |
|
|
|
|
|
|
|
|
Replacement Filter |
Model 110 or 113 |
Model 210, 213, 213CBN |
Model 310 or 313 |
Model 410, 413, 413CBN |
Model 910 or 913 |
|
with SelfSeal™ |
or 216 with SelfSeal™ |
with SelfSeal™ |
or 416 with SelfSeal™ |
with SelfSeal™ |
||
|
||||||
|
|
|
|
|
|
|
Maximum Equipment Weight |
Cabinet will support |
|
Cabinet will support 400 lb. static load |
|
||
250 lb. static load |
|
|
||||
|
|
|
|
|
||
|
|
|
|
|
|
|
Air Purifier Operating Environment |
|
Temperature: 0°F–140°F, Humidity: 0–90% non-condensing |
|
|||
|
|
|
|
|
|
DIMENSIONS |
|
|
|
|
|
|
|
|
|
|
B |
|
|
D |
|
E |
|
|
|
WITHOUT DOOR |
|
|
|
|
WITH DOOR |
|
|
|
|
|
C |
|
|
|
|
F |
|
|
|
A |
|
|
|
|
|
|
|
G |
H |
|
|
|
|
|
|
|
|
90-1333 |
|
TABLE 1 – DIMENSIONS (INCHES) |
|
|
|
|
|
|
|
|
|
Model |
A |
B |
C |
D |
E |
F |
G |
H |
|
1110 |
15-7/16 |
20-1/16 |
17-3/8 |
6-3/4 |
22-1/16 |
17-3/8 |
15-7/16 |
17-3/4 |
|
1210, 2210, 2216, 3210 |
19-3/4 |
25-3/8 |
21-3/16 |
6-3/4 |
27-3/8 |
21-3/16 |
19-3/4 |
22-1/16 |
|
1310, 2310, 3310 |
18-1/16 |
20-1/16 |
15-7/8 |
6-3/4 |
22-1/16 |
15-7/8 |
18-1/16 |
20-3/8 |
|
1410, 2410, 2416, 3410 |
15-7/16 |
28-1/16 |
23-7/8 |
6-3/4 |
30-1/16 |
23-7/8 |
15-7/16 |
17-3/4 |
|
1910 |
22-3/4 |
20-1/16 |
15-7/8 |
6-3/4 |
22-1/16 |
15-7/8 |
22-3/4 |
25-1/16 |
|
|
|
|
|
|
|
|
|
English 1 |
INSTALL THE AIR PURIFIER CABINET
LOCATING THE AIR PURIFIER
1. |
Leave sufficient space in front of the air purifier for the |
|
|
removal of the filter (see FIGURE 1). |
FIGURE 2 – HORIZONTAL INSTALLATION |
|
|
|
2. |
DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. |
|
|
UV lamps will cause degradation of the filtering media. |
|
3. FIGURES 2-4 show typical applications.
AIRFLOW
90-1319
FIGURE 1 – FILTER CLEARANCE
|
30° MAX |
|
|
|
AIRFLOW |
|
|
30° MAX |
|
|
90-2099 |
|
FIGURE 3 – HIGHBOY PLATFORM INSTALLATION |
|
|
AIRFLOW |
AIRFLOW |
|
|
|
SEE DIMENSION E |
|
PLENUM BOX |
|
|
90-1374 |
90-2100 |
90-1318 |
FIGURE 4 – UPFLOW INSTALLATION |
|
AIRFLOW |
AIRFLOW |
|
30°MAX |
|
45°MAX |
|
AIRFLOW |
PLENUM
BOX
90-1320 |
90-2101 |
90-1320 |
2 English
INSTALLATION
1.Disconnect power to the furnace or air handler at the electrical service panel.
WARNING
120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed.
2.Remove the air purifier door from the outer housing and pull out the filter (see FIGURE 5).
3.If replacing an existing filter, remove the filter and thoroughly clean the blower compartment.
4.Use screws (field supplied) to mount the outer housing to the furnace/air handler. There is no inlet or outlet side on the outer housing (the outer housing can be mounted on the left or right side of the furnace/air handler).
NOTE FOR UPFLOW INSTALLATIONS: Provide support under the outer housing to ensure the quality of the seals (see FIGURE 6).
5.Mount the return ductwork to the outer housing.
6.Seal all connections using mastic, foil tape or silicone based caulk.
7.Install the filter (see FIGURE 7).
8.Install the door.
9.Reconnect power to the furnace or air handler at the electrical service panel.
FIGURE 5 |
90-2345 |
FIGURE 6
90-1374
FIGURE 7
EXPAND
CLEAN FILTER.
INSTALL FILTER WITH AIR FLOW POINTING
TOWARD FURNACE OR AIR HANDLER.
ALIGN FILTER IN TOP AND BOTTOM RAILS
AND SLIDE INTO PLACE. REINSTALL DOOR.
90-2344
90-2346
English 3
AprilairePartners.com
P.O. Box 1467
Madison, WI 53701-1467 800.334.6011 F: 608.257.4357 Printed in USA
©2018 Aprilaire – Division of Research Products Corporation
10011245 B2701359C 1.18
4 English