For STM-64/OC-192 Jitter Evaluation
The MP1777A is a measurement solution for jitter evaluation. It supports both the STM-16/32/64 and OC-48/96/192 bit rates. In addition to supporting the bit rates of 2488.32, 4976.64, and 9953.28 MHz four additional bit rates used in submarine cable systems can be added as options. The MP1777A can evaluate jitter characteristics, including jitter tolerance, jitter transfer and output jitter, which are par ameters most commonly used to evaluate digital lines. The MX177701A Jitter Performance Test Software (bundled with MP1777A)allows the MP1777A to be controlled remotely from a controller. And when the Jitter Performance Test Software is used together with specified auxiliary measuring instruments, jitter tolerance and jitter transfer characteristics can be measured automatically.
•Conforms to O.172 Recommendations
The MP1777A meets the STM-64/OC-192 measurement standards. It is compatible with bandwidths up to 80 MHz and jitter modulation amplitudes up to 3200 UIp-p.
March, 1999 edition
• Four Optional Series of Bit Rates
Current submarine cable systems add FEC (forward error correction) to signals to enhance quality. The MP1777A can also support two series of bit rates by adding Option 01 (2494.16, 4988.32, 9976.64 MHz), Option 02 (2666.0571,
5332.1142, 10664.2284 MHz), Option 04 (3062.3629,
6124.7259, 12249.4517 MHz) and Option 05 (3069, 6138, 12276 MHz).
• Automatic Jitter Measurement
The MX177701A Jitter Performance Test Software is used for automatic jitter measurement and can be used with the MP1777A to configure an automatic measurement system for jitter tolerance and jitter transfer characteristics
1
.
1: Requires MS4630B Network Analyzer, MP1763B Pulse Pattern Generator and MP1764A Error Detector for automatic measurement of jitter tolerance. Requires MS4630B Network Analyzer and MP1763B Pulse Pattern Generator for automatic measurement of jitter transfer. Also requires controller, MX177701A Jitter Performance Test Software, GPIB card and cables.
*
Application Examples
• Jitter Generation
To generate jitter an external signal generator is required to source a modulation signal. The MX177701A Jitter Performance Test Software and a GPIB card are required for automatic measurement. It is also possible to perform man­ual measurements which does not require these items.
MP1777A 10 GHz Jitter Analyzer MS4630B Network Analyzer
GPIB
• Jitter Measurement
The MP1777A can measure the jitter of input signals directly without using an external BPF. When Option 10 (High Sensitive Input) is installed, it can measure the jitter of input signals with amplitudes down to 150 mVp-p. In this case, it can perform evaluation by direct device connection. The MX177701A Jitter Performance Test Software and a GPIB card are required for automatic measurement. Manual mea­surement is also possible and the measurement results are checked on the MP1777A screen. Fur ther more, UIp-p, UI+p, UI-p, and UIrms can also be measured. By combining the MP9677B E/O and O/E Converter, the MP1777A can measure the jitter measurement of optical interfaces.
Controller: Windows®95 or more (with MX177701A Jitter Performance Test Software)
2
Controller: Windows®95 or more (with MX177701A Jitter Performance Test Software)
MP9677B E/O, O/E Converter
Optical data input
Clock output
GPIB
MP1777A 10 GHz Jitter Analyzer
• Measuring Jitter Transfer Characteristics
The MP1777A can evaluate jitter transfer characteristics up to 80 MHz in applications such as 10 Gbit/s clock recovery module (O/E converter) evaluation. Automatic (using MX177701A external soft­ware/GPIB) and manual measurements are possible. By combining the MP9677B E/O and O/E Converter, the MP1777A can evaluate the jitter transfer characteristics up to 80 MHz at opti­cal interfaces.
•Jitter T olerance Measurement
By combining the O/E and E/O converters, the MP1777A can measure the jitter tolerance of optical interfaces. The MX177701A Jitter Performance Test Software and a GPIB card are required for automatic measurement. It is also possible to perform manual measurements without these items.
3
Data output
Clock output
DUT
GPIB
MS4630B Network Analyzer
MP1763B Pulse Pattern Generator
MP1777A 10 GHz Jitter Analyzer
MP9677B E/O, O/E Converter
E/O converter
MP1763B Pulse Pattern Generator
MP1777A 10 GHz Jitter Analyzer
MS4630B Network Analyzer
O/E converter
Controller: Windows
®
95 or more
(with MX177701A Jitter Performance Test Software)
DUT
ATT
GPIB
MP1764A Error Detector
Controller: Windows
®
95 or more
(with MX177701A Jitter Performance Test Software)
MP1777A 10 GHz Jitter Analyzer
1 Start/Stop: Used to start/stop measurement 2 Result: Displays main measurement results screen 3 Test Menu: Displays test menu screen 4 Setup: Displays setup screen 5 Cursor
Set: Used to set data, input numeric values, and open
ASCII window
Cancel: Used when setting data. Also used to cancel input
numeric values, and to close string windows
<, , , >: Used to move cursor on screen or window cursor.
In the numeric value input window, the and keys are used to increase and decrease the numeric values, respectively.
<
<
<
<
1 2 3 4 5
6 7
10
11
6 Unlock: Lights when jitter receiver unlocked 7 Alarm: Lights when jitter transmitter unlocked 8 Demod. Output: Detected jitter analog signal output,
BNC connector (50 Ω)
9 Clock Input: Clock input, APC 3.5 connector (50 Ω)
10
Clock Output: Clock output, APC 3.5 connector (50 Ω)
11
Ext Mod Input : External modulation signal input,
BNC connector (50 Ω)
4
9
8
12
Ext Ref Clock Input: Exter nal reference signal input
(155.52 MHz standard)
13
DCS Input (120 Ω): Input to synchronize with external
signal. Input clock or data conforming to ITU-T G.703-10.
14
DCS Input (100 Ω): Input to synchronize with exter-
nal signal. Input AMI, or B8ZS data conforming to ANSI TI.
15
DCS Input (75 Ω):Input to synchronize with external
signal. Input clock or HDB3 data conforming to ITU-T G.703-10.
16
10M STD Input : Input to synchronize with external 10
MHz signal
17
GPIB: GPIB interface
12
13 14 15 16
17
5
Specifications
Standard: 2488.32, 4976.64, 9953.28 Mbit/s Option 01: 2494.16, 4988.32, 9976.64 Mbit/s
Bit rate
Option 02: 2666.0571, 5332.1143, 10664.2286 Mbit/s Option 04: 3062.3629, 6124.7259, 12249.4517 Mbit/s Option 05: 3069, 6138, 12276 Mbit/s Option 02, 04 and 05 can not be installed simultaneously.
Modulation frequency: 10 Hz to 80 MHz Amplitude: 0 to 3200 UIp-p Resolution: 0.001 UIp-p (0.5 UI range), 0.01 UIp-p (20, 40, 80 UI range), 1 UIp-p (800, 1600, 3200 UI range)
Jitter generation
Accuracy:
±5% ±10 UIp-p/Fr (3200 UI range), ±5% ±8 UIp-p/Fr (1600 UI range), ±5% ±5 UIp-p/Fr (800 UI range), ±5% ±0.8 UIp-p/Fr (80 UI range), ±5% ±0.6 UIp-p/Fr (40 UI range), ±5% ±0.3 UIp-p/Fr (20 UI range),
±5% ±0.1 UIp-p/Fr (0.5 UI range/10G), ±5% ±0.08 UIp-p/Fr (0.5 UI range/5G), ±5% ±0.05 UIp-p/Fr (0.5 UI range/2.5G) Fr: 100 kHz (0.5, 20, 40, 80 UI range), 10 Hz (800, 1600, 3200 UI range) Frequency response error (Fr Hz):
±5% (10 to 20 Hz), ±2% (20 Hz to 300 kHz), ±3% (300 kHz to 1 MHz), ±5% (1 to 3 MHz), ±10% (3 to 10 MHz), ±15% (10 to 80 MHz)
Frequency offset
Range: ±50 ppm (0.1 ppm steps) Accuracy: ±0.1 ppm (after power-on, calibrates after 60 min.warm-up 23 ±5°C)
Auxiliary interface External modulation input, external 10 MHz reference input, DCS input, external reference clock input
Modulation frequency: 100 Hz to 80 MHz Amplitude: 0 to 4.00 UIp-p, 0 to 1.41 UIrms Resolution: 0.001 UIp-p/0.001 UIrms (1 UI range), 0.01 UIp-p/0.01 UIrms (4 UI range)
Jitter measurement
Bit rate f0 f1 f2 f3 f4 f4’ f5 A1 A2’ A2 A3’ A3 (bit/s) (Hz) (Hz) (Hz) (kHz) (MHz) (kHz) (MHz) (UIp-p) (UIp-p) (UIp-p) (UIp-p) (UIp-p)
2488M 10 15 480 100 2 100 20 0.5 1 20 25 800 4977M 10 15 480 100 2 100 40 0.5 2 40 50 1600 9953M 10 15 480 100 2 100 80 0.5 4 80 100 3200
Jitter frequency (Hz)
Jitter amplitude (UIp-p)
Jitter frequency (Hz)
Jitter amplitude (UIp-p)
Bit rate(bit/s)
A2 A3’ A3 f0 f3 f4
(UIp-p) (UIp-p) (UIp-p) (Hz) (MHz) (MHz)
2488M
1 UI range 0.5 1 100 10 20 4 UI range 0.5 4 100 2.5 20
4977M
1 UI range 0.5 1 100 20 40 4 UI range 0.5 4 100 5 40
9953M
1 UI range 0.5 1 100 40 80 4 UI range 0.5 4 100 10 80
6
800/1600/3200 UI range (2488M/4977M/9953M
A3 A3' A2 A2'
A1
–20 dB/dec
f0 f1 f2 f3 f4' f4 f5
20/40/80 UI range (2488M/4977M/9953M
)
)
–20 dB/dec
0.5 UI range
A3 A3'
A2
f0 f3f3f4
f0
4 UI range
1 UI range
1 UI range
f4
4 UI range
Accuracy
[UIp-p]: ±5 % ±W UIp-p (Fr Hz) [UIrms]: ±5 % ±Y UIrms (Fr Hz), Fr:100 kHz
Frequency response error (Fr Hz):
±5% (10 to 20 Hz), ±2% (20 Hz to 300 kHz), ±3% (300 kHz to 1 MHz), ±5% (1 to 3 MHz), ±10% (3 to 10 MHz), ±15% (10 to 80 MHz)
Jitter measurement
*
1
With HP1 + LP, *2With HP + LP
Filters: LP, HP1 + LP, HP1' + LP, HP2 + LP, HP + LP, HP' + LP
Auxiliary interface Demodulation output Internal memory Measurement conditions: 10 Others GPIB, Buzzer, Time
Dimensions and
426 (W) x 221.5 (H) x 451 (D) mm, 23 kg (with option)
mass Power 100 to 240 Vac, 47.5 to 63 Hz, 350 V A
Temperature 10˚ to 40˚C EMC EN61326 : 1997/A1:1998 (Class A), EN61000-3-2: 1995/A2: 1998 (Class A), EN61326: 1997/A1:1998 (Annex A) LVD EN61010-1: 1993/A2:1995 (Installation categor y II, Pollution degree 2)
bit rate (bit/s)
W (UIp-p)*
1
Y (Ulrms)*
2
1 UI 4 UI 1 UI 4 UI 2488M 0.05 0.22 0.008 0.08 4977M 0.07 0.24 0.009 0.09 9953M 0.09 0.26 0.010 0.10
bit rate (bit/s)
HP1 HP1’ HP2 HP HP’ LP
(kHz) (kHz) (MHz) (kHz) (kHz) (MHz) 2488M 5 1 12 20 4977M 8 2 12 40 9953M 10 20 4 12 50 80
•Operation environment
Pulse Pattern Generators: MP1763B (12.5 GHz), MP1570A SONET/SDH/PDH/ATM Analyzer Applicable Error Detectors: MP1764A (12.5 GHz), MP1570A SONET/SDH/PDH/ATM Analyzer instruments Network Analyzer: MS4630B (300 MHz, with Option 10)
E/O, O/E Converter: MP9677B E/O, O/E Converter
Personal computer: IBM-PC/AT compatible
OS: Windows
®
95 (English) or Windows®98 (English) CPU: Pentium (75 MHz or faster) Memory size: 16 Mbyte min. HDD free space: 300 kbyte for full install
Recommended
GPIB interface:
controller
National Instruments AT-GPIB/TNT (PnP), AT-GPIB/TNT+, PCMCIA-GPIB, or PCMCIA-GPIB+ and Windows driver (for Windows
®
95 or Windows®98) Swap file size: 40 Mbyte guaranteed Display colors: Set to 256 Number of applications running simultaneously: 1 (unable to run other applications simultaneously)
Windows®95 and Windows®98 are registered trademarks of Microsoft®Corporation.
7
Catalog No. MP1777A-E -A -1-(5.00) Pr inted in Japan 2002-2 20W/M
Ordering Information
Model/order No. Name Remarks
Main frame
MP1777A 10 GHz Jitter Analyzer
Standard accessories
J0670A AC power cord: 1 pc F0014 Fuse, 6.3 A: 2 pcs B0329D Front cover: 1 pc W1497AE MP1777A operation manual: 1 copy W1498AE MP1777A remote control operation manual: 1 copy J0496 APC 3.5 J-J connector: 2 pcs J0900E SMA cable (50 ), 1.5 m: 2 pcs AA-165-1500 J0776C BNC cable (50 ), 1 m: 3 pcs J0008 GPIB cable, 2 m: 1 pc MX177701A Jitter Performance Test Software*
1
:1 pc
W1499AE MX177701A operation manual: 1 copy
Options
MP1777A-01 2494M/4988M/9977M Jitter*
2
MP1777A-02 2666M/5332M/10664M Jitter*
3
MP1777A-04 3062M/6124M/12249M Jitter*
4
MP1777A-05 3069M/6138M/12276M Jitter*
5
MP1777A-10 High sensitive input 0.15 to 1.3 Vp-p
Application equipment
MS4630B Networ k Analyzer 10 Hz to 300 MHz (with Option 10) MP1763B Pulse Pattern Generator 12.5 GHz MP1764A Error Detector 12.5 GHz MP1570A SONET/SDH/PDH/ATM Analyzer MP9677B E/O, O/E Converter Jitter bandwidth: 80 MHz
Please specify the model/order number, name, and quality when ordering.
1: Please confirm the operating system.2: 2494.16, 4988.32, 9976.64 MHz3: 2666.0571, 5332.1142, 10664.2284 MHz4: 3062.3629, 6124.7259, 12249.4517 MHz5: 3069, 6138, 12276 MHz
ANRITSU CORPORATION MEASUREMENT SOLUTIONS
5-10-27, Minamiazabu, Minato-ku, Tokyo 106-8570, Japan Phone: +81-3- 3446 - 1111 Telex: J34372 Fax: +81 - 3 - 3442 - 0235
U.S.A. ANRITSU COMPANY North American Region Headquarters
1155 East Collins Blvd., Richardson, Tx 75081, U.S.A. Toll Free: 1 - 800 - ANRITSU (267 - 4878) Phone: +1-972 - 644 - 1777 Fax: +1 - 972 - 671 - 1877
Canada ANRITSU ELECTRONICS LTD.
Unit 102, 215 Stafford Road West Nepean, Ontario K2H 9C1, Canada Phone: +1-613- 828 - 4090 Fax: +1 - 613 - 828 - 5400
Brasil ANRITSU ELETRÔNICA LTDA.
Praia de Botafogo 440, Sala 2401 CEP 22250-040, Rio de Janeiro, RJ, Brasil Phone: +55-21- 5276922 Fax: +55 - 21 - 537 - 1456
U.K. ANRITSU LTD.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582- 433200 Fax: +44 - 1582 - 731303
Germany
ANRITSU GmbH
Grafenberger Allee 54-56, 40237 Düsseldorf, Germany Phone: +49-211- 96855 - 0 Fax: +49 - 211 - 96855 - 55
France
ANRITSU S.A.
9, Avenue du Québec Z.A.de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1- 60 - 92 - 15 - 50 Fax: +33-1-64-46-10-65
Italy
ANRITSU S.p.A.
Via Elio Vittorini, 129, 00144 Roma EUR, Italy Phone: +39-06- 509 - 9711 Fax: +39 - 06 - 502 - 24 - 25
Sweden
ANRITSU AB
Botvid Center, Fittja Backe 1-3 145 84 Stockholm, Sweden Phone: +46-853470700 Fax: +46 - 853470730
Spain
ANRITSU ELECTRÓNICA, S.A.
Europa Empresarial Edificio Londres, Planta 1, Oficina 6 C/ Playa de Liencres, 2 28230 Las Rozas.Madrid, Spain Phone: +34-91- 6404460 Fax: +34 - 91 - 6404461
Singapore
ANRITSU PTE LTD.
10, Hoe Chiang Road #07-01/02, Keppel Towers, Singapore 089315 Phone: +65-282- 2400 Fax: +65 - 282 - 2533
Hong Kong
ANRITSU COMPANY LTD.
Suite 719, 7/F., Chinachem Golden Plaza, 77 Mody Road, Tsimshatsui East, Kowloon, Hong Kong, China Phone: +852-2301- 4980 Fax: +852 - 2301 - 3545
Korea
ANRITSU CORPORATION
14F Hyun Juk Bldg. 832-41, Yeoksam-dong, Kangnam-ku, Seoul, Korea Phone: +82-2- 553 - 6603 Fax: +82 - 2 - 553 - 6604
˜
5
Australia
ANRITSU PTY LTD.
Unit 3/170 Forster Road Mt.Waverley, Victoria, 3149, Australia Phone: +61-3- 9558 - 8177 Fax: +61 - 3 - 9558 - 8255
Taiwan
ANRITSU COMPANY INC.
6F, 96, Sec. 3, Chien Kou North Rd. Taipei, Taiwan Phone: +886-2- 2515 - 6050 Fax: +886 - 2 - 2509 - 5519
Specifications are subject to change without notice.
Loading...