Agilent Technologies HP 16505A, HP 16500, HP 16500B, HP 16500H User Manual

About this Manual
We’ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information. If we find a more recent copy in the future, we will add it to the Agilent website.
Support for Your Product
Agilent no longer sells or supports this product. Our service centers may be able to perform calibration if no repair parts are needed, but no other support from Agilent is available. You will find any other available product information on the Agilent Test & Measurement website, www.tm.agilent.com.
HP References in this Manual
This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy. In other documentation, to reduce potential confusion, the only change to product numbers and names has been in the company name prefix: where a product number/name was HP XXXX the current name/number is now Agilent XXXX. For example, model number HP8648A is now model number Agilent 8648A.
Installation and Service Guide
Publication number 16500-97012 First edition, April 1995
For Safety information, Warranties and Regulatory information, see the pages behind the index
Copyright Hewlett-Packard Company 1993, 1994, 1995
All Rights Reserved
HP 16500H Interface Module
In This Book
This book shows you how to install and service the HP 16500H Interface Module . This book contains the following chapters:
Chapter 1 provides and overview of the HP 16500H.
Chapter 2 shows you how to install the HP 16500H in the HP 16500B
mainframe. This chapter also provides information on where to go next, depending on which environment you are using the HP 16500 system in.
Chapter 3 contains the procedures for performance verification and
replacing assemblies. This chapter tells you where to find information on troubleshooting the system, depending on which environment you are using the HP 16500B system in.
See Also
The
HP 16500H LAN Interface Module Administrator’s and Service
for information on installing and setting up the HP 16500H in the LAN
Guide
environment.
The
HP 16500B Logic Analysis System Setting UP the System Guide
information on installing and setting up an HP 16501A Expansion Frame.
The
HP 16505A Prototype Analyzer Installation Guide
installing and setting up an HP 16505A Prototype Analyzer.
The
Logic Analyzer Training Kit
operation of the HP 16500B system.
if you are unfamiliar with the basic
for information on
for
ii
Contents
1 Introducing the HP 16500H Interface Module
Accessories Supplied 1–3 Requirements 1–3 Physical Connections 1–3 LAN Support 1–4
2 Installing the Interface Module
To Install the HP 16500H Hardware 2–2 To Verify the Installation 2–4 Ethernet LAN Interface 2–5 HP 16501A Expansion Frame Interface 2–7 HP 16505A Protoytype Analyzer 2–8
3 Servicing the Interface Module
Verify the Interface Module Performance 3–2 Troubleshooting an HP 16501A Expansion Frame 3–7 Troubleshooting in an Ethernet LAN Environment 3–8 Troubleshooting in the HP 16505A Prototype Analyzer Environment 3–9 Removing and Replacing the HP 16500H Interface Module 3–10 Returning Parts 3–13 Ordering Replaceable Parts 3–14 Replaceable Parts List 3–15
Contents-1
Contents-2
1
Introducing the HP 16500H 1-2
Accessories Supplied 1–3
Requirements 1–3
Physical Connections 1–3
LAN Support 1-4
Introducing the HP 16500H Interface Module
Introducing the HP 16500L LAN Interface Module
The HP 16500H LAN interface module provides three capabilities for your HP 16500 Logic Analysis System:
connection to an Ethernet 10Base-T Local Area Network (LAN)
connection to an HP 16501A Expansion Frame for the HP 16500B
Logci Analysis System
a high-speed port for connecting the HP 16500B to an HP 16505A
Prototype Analyzer
Expander Frame connector
Ethertwist LAN connector
High-speed port
The HP 16500H interface module
1–2
Introducing the HP 16500H Interface Module
Accessories Supplied
Accessories Supplied
The HP 16500H is shipped with the following accessories:
Installation and Service Guide
this
LAN Administrator’s and Service Guide
a
LAN User’s Guide
a
screws and one cable to install the HP 16500H into the HP 16500B
mainframe
TORX 10 and TORX 15 wrenches
If your HP 16500H was installed into the HP 16500B by HP, you will not receive these tools. If your HP 16500H was not installed by HP, you will receive these tools.
Requirements
HP 16500B Logic Analysis System mainframe, and one of the following:
NFS or FTP capabilities on your TCP/IP Ethernet LAN, or
HP 16501A Expansion Frame, or
HP 16505A Prototype Analyzer
Physical Connections
RJ-45 connector for direct connection to 10Base-T networks
68-pin D-connector for connection to an HP 16501A Expansion Frame
High-speed port for connection to an HP 16505A Prototype Analyzer
1–3
Introducing the HP 16500H Interface Module
LAN Support
LAN Support
For information about the LAN protocols and file types supported by the HP 16500H, refer to the
LAN Administrator’s and Service Guide
1–4
2
This chapter includes procedures to install the interface module into the HP 16500B Logic Analysis System mainframe and to verify the installation.
For detailed information on how to install the HP 16500B in one of the three applications supported by the interface module, refer to the documentation for the specific application. This chapter provides references to those other documents.
To Install the HP 16500H Hardware 2-2
To Verify the Installation 2-4
Ethernet LAN Interface 2-5
HP 16501A Expansion Frame Interface 2-7
HP 16505A Prototype Analyzer Interface 2-8
Installing the Interface Module
WARNING
Installing the Interface Module
To Install the HP 16500H Hardware
To Install the HP 16500H Hardware
If you need instructions for removing and replacing parts of the HP 16500B, refer to the
SHOCK HAZARD
performing the following procedures. After disconnecting the power, wait at least six minutes for the capacitors on the power supply board and the CRT driver board to discharge before servicing the instrument. Failure to do so could result in electrical shock. Hazardous voltages exist on the power supply, the CRT, and the CRT driver board of the HP 16500B mainframe. As long as the AC LED on the power supply has any illumination, a significant charge remains on the capacitors.
HP 16500B Logic Analysis System Service Guide
Disconnect the power from the mainframe before
.
CAUTION
Use grounded wriststraps and mats when performing any service to this module or to the HP 16500B Logic Analysis System. Electrostatic discharge can damage electronic components.
For correct orientation of the cables, match the slots on the cable connectors and on the board connectors.
1
Remove power from the HP 16500B mainframe, then remove the measurement modules, the four rear feet, and the top and bottom covers of the mainframe.
2
Remove the sheetmetal plate on the rear of the mainframe covering the slot where the interface module will be installed.
With the interface module installed, you will not use the plate. Save the plate to use in case the interface module is removed.
2–2
Installing the Interface Module
To Install the HP 16500H Hardware
3
Slide the interface module into the mainframe through the slot in the rear panel.
4
Install the screws connecting the interface module to the mainframe.
Two screws through the top of the interface module connect it to the sheetmetal plate, and four screws through the rear plate of the interface module connect it to the rear panel of the mainframe.
5
Connect the 80-pin cable to the CPU board and to the interface module.
Before installing the cable, inspect the cable and the connectors for any signs of damage.
a
Slide the 80-pin cable halfway through the rear slot of the card cage between the interface module and the CPU board.
b
Connect the cable to the CPU board.
c
Connect the cable to the interface module.
6
Replace the top and bottom covers, the optional modules, and the rear feet of the mainframe.
Installing the Interface Module
2–3
Loading...
+ 26 hidden pages