Dear Customer,

If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come.

CONTENTS

RECOMMENDATIONS AND SUGGESTIONS

12

CHARACTERISTICS

13

INSTALLATION

14

USE

17

MAINTENANCE

18

GB

 

11

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.

The minimum safety distance between the cooker top and the extractor hood is 650 mm.

Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.

For Class I appliances, check that the domestic power supply

guarantees adequate earthing.

Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.

Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).

If the extractor is used in conjunction with non-electrical appliances

(e.g. gas burning appliances), a sufficient degree of aeration must

be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean

air.

650 mm min.

USE

The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.

Never use the hood for purposes other than for which it has ben designed.

Never leave high naked flames under the hood when it is in

operation.

• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.

Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.

The hood should not be used by children or persons not instructed in its correct use.

MAINTENANCE

Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.

Clean and/or replace the Filters after the specified time period.

Clean the hood using a damp cloth and a neutral liquid detergent.

GB

 

12

AEG EFC9510XCH, EFC6510XCH User Manual

CHARACTERISTICS

Dimensions

260

300

62 - 72

598 - 898

Components

55 433

740940 740minmax

545

The described equipment could change according to the different countries.

 

15

 

Ref.

Q.ty

Product Components

 

 

1

1

Hood Body, complete with: Controls, Light,

 

 

14.1

 

 

 

 

Blower, Filters

 

 

 

 

 

 

 

 

2

1

Telescopic Chimney comprising:

16

12a

7.2.1 11

2.1

1

Upper Section

 

2.2

1

Lower Section

 

 

 

14

 

 

8a

1

Right Air Outlet Grill

9

 

 

8b

1

Left Air Outlet Grill

 

 

 

9

1

Reducer Flange ø 150-120 mm

 

 

 

14

1

Hood Body Air Outlet Extension Piece consisting

 

 

 

 

 

of two Half Shells

2.1

 

12c

14.1

2

Air Outlet Connection Extension

 

 

15

1

Air Outlet Connection

2

 

 

 

 

16

1

Air Outlet Deflector

8b

 

 

 

8a

 

 

 

 

 

 

 

 

2.2

 

 

Ref.

Q.ty

Installation Components

 

 

 

 

 

 

7.2.1

2

Upper Chimney Section Fixing Brackets

 

 

 

11

6

Wall Plugs

 

 

11

12a

6

Screws 4,2 x 44,4

 

 

12c

6

Screws 2,9 x 9,5

 

 

12a

 

 

 

 

 

 

 

 

 

Q.ty

Documentation

1

 

 

 

1

Instruction Manual

GB

 

13

Loading...
+ 7 hidden pages