Dear customer, Congratulations on the purchase of the product 2N OMEGA Lite. This new product
was developed and manufactured with an emphasis on maximum user value, quality and reliability. It is our desire that the 2N OMEGA Lite should give you complete
and long satisfaction.
Installation manual 2
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
1. Basic module.................................................................................................................4
Description of parts of basic module.....................................................................................6
2. Description of mechanical parts.....................................................................................6
2.1. Base (chassis)......................................................................................................................6
2.2. PBX cover............................................................................................................................7
3. Description of electrical components..............................................................................8
3.1. Motherboard.........................................................................................................................8
3.2. Power supply......................................................................................................................11
3.3. Source – mains part _ ringing transformer...........................................................................11
3.4. Display...............................................................................................................................13
Other separate components.................................................................................................14
4. Extender module (order No 1880010)..........................................................................14
CONTENT
5. Interface modules.........................................................................................................15
5.1. Module 2x internal line (order No 1880030).........................................................................16
5.2. Module 2x system telephone (order No 1880039)...............................................................17
5.3. Module 1x external line / 1x internal line (order No 1880031)...............................................19
5.4. Module 1x external line/1xinternal line with 16 kHz tariff pulse receivers (order No1880032)20
5.5. Module GSM 900/1800/1900 Mhz pro 1-2 GSM.....................................................................21
5.6. Module ISDN S0 (Order No 1880020).................................................................................22
5.9. Module VoIP (Order No 1880021)......................................................................................24
6. Detailed installation.....................................................................................................25
6.1. Selection of place for PBX..................................................................................................25
6.2. Unpacking and checking.....................................................................................................26
6.3. Installation of extender module............................................................................................26
6.4. Installation of Line modules.................................................................................................27
6.5. Installation of VoIP module.................................................................................................28
7. Mounting PBX on wall................................................................................................38
7.1. Earthing PBX......................................................................................................................38
7.2. Connection to mains network..............................................................................................39
7.3. Cabling for connecting system telephones..........................................................................39
7.4. Cabling for connecting ISDN...............................................................................................39
8. Minor servicing tasks...................................................................................................40
8.1. Replacement of lithium battery............................................................................................40
8.2. Setting music volume..........................................................................................................40
9. Expanding PBX...........................................................................................................41
10. Installation of front-end protection...............................................................................41
11. Technical parameters...................................................................................................42
Installation manual 3
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
1. Basic module
Types of basic modules
1880000 - basic module without modem for RemoteSupervision up to 24
lines 1880001 - basic module with modem for RemoteSupervision up to 24 lines
Installation manual 4
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
In its assembled state, each basic module contains these parts:
chassis (metal part of mechanism) with power source
display
plastic cover
motherboard with or without modem for remote supervision (RS)
1x platelet for power cable
2x blanking platelets
The following components are included:
Wall-mounting element (part of basic module)
Rawlplugs and screws for wall mounting
Power cable
Screws for fixing serial or blanking platelets
It also contains this equipment:
CD with complete documentation and necessary SW
Serial cable with RJ-12 terminal and one gender changer for DB-9 connector
Installation manual 5
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
Description of parts of basic module
2. Description of mechanical parts
2.1. Base (chassis)
The base carries the other parts. The power supply (plug 230V/AC + power switch) is mounted in the upper right part. The upper left + lower left part is intended for fitting the extender. The strip with holes in the bottom part is intended for fitting serial and blanking platelets. The display is fixed in the upper part in the centre.
Installation manual 6
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
2.2. PBX cover
The plastic cover bears a sticker with a transparent window for the display.
The cover is fitted on the chassis by fitting into two holes in the upper part of the plastic and is secured by two extendable “pegs” into the lower part of the plastic.
When dismantling the cover, first press (using an appropriate tool) both extendable “pegs”, whereby you free the cover and then remove the cover.
Installation manual 7
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3. Description of electrical components
3.1. Motherboard
Installation manual 8
www.2n.cz
2N
®
1 - RTS
2 - TXD
3 - GND
4 - GND
5 - RXD
6 - CTS
Connecting
- OMEGA Lite
Installation manual
B1 - Lithium battery holder. We recommend replacement when the voltage is lower than 2.5
V, or at least once every three years. We recommend the batteries be replaced with the PBX off. Before replacement we recommend saving the program of the PBX and the accounting data in a PC. After replacement check the date, time and program of the PBX and, if not correct, make the correct adjustment. Never change the batteries when the PBX is on. WARNING! Use only a tool made from insulating material for replacement!!!
J1 - connector for connecting extender J2 – J7 - connectors for connecting line modules (description of modules – see Chapter 5) J8 – J9 - shorting jumpers (connected – RS232-COM is connected to the J18 connector,
disconnected – RS232-COM is connected to the module VoIP)
J10 - company’s servicing reanimation connector (1 Hz) J11 - connector for connecting additional memory for announcements (180 s) J12 - shorting jumper – always fitted (activation WATCH DOG) J13 - company’s servicing reanimation connector (SW for ALTERA) J14 - company’s servicing reanimation connector (SW for CPU) J15 - connector for connecting VoIP module J16 -.connector for connecting LED signalling J17 - connector for display J18 - connector RJ12 with galvanic isolation for PC connection (RS232-COM). J19 - input voltage connector – (1. +5V, 2.,4. GND, 3. +24V, 5. -24V, 6. RINGV). J20 - voltage connector – (1. RINGV, 2. -24V, 3. GND, 4. +24V) ). J21 - output voltage connector – (+24V DC). J22 - input voltage connector – (+24V DC). J23 - shorting jumper – always disconnected (only for testing purposes – connection
GND and PGND),
J24 - servicing connector (locking of FLASH memory). J25 - line input (CINCH – AUX IN) for connecting external music source (for example
CD, radio).
SW1 - Auxiliary RESET1 button (pressing results in reset). SW2 - Auxiliary RESET2 button (1. –setting company values (press button + switch on
PBX + confirm by pressing again after display of message “Clear config? - push again/wait“, 2. entry to “service mode” (hold button down during test of RAM memory).
P1 - regulating volume of line input. U1 - governing processor
U2-3 - connecting cross-point array. D1 - signalling +5V
D2 - signalling -12V D3 - signalling +12V
1
6
up connector RJ-12 (J18)
Installation manual 9
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
Note:
J18 – the connector is intended for connecting the PBX with a PC. It thus allows the programming of the PBX using the program OMEGA Lite - PROGRAM, detailed display of operation using program OMEGA Lite - PANEL, for connection of XAPI Server, etc.
The serial port includes an insulating DC/DC converter of its own and, by optical signal transmission, provides galvanic isolation of the serial port from the PBX with a guaranteed insulation strength of 500 V.
This solution has the following advantages:
Helps transmit data over long distances
Improves data transmission reliability (resistance to disruption)
Enables communication with a PC powered from a different power supply section
(for example, from a different phase or central UPS)
Improves overvoltage resistance of the input For connection with a PC, especially over a greater distance, a normal (i.e., cross-
over) four-wire telephone cord with RJ-12 terminals is normally used instead of a special “serial cable”.
Installation manual 10
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3.2. Power supply
As the Power supply a power supply module with open construction and with output voltage of +24VDC/2.7A (connector J2) is used. One integral part of the supply is the cooler, which is designed for an upright working position of the PBX. It is not allowed to operate the PBX in a horizontal position (lying on a table etc). The source is distinguished in particular by the simplicity of connection, which is a guarantee of the source’s maximum reliability. The source has an overvoltage fuse (F1) F4A/250V. The power goes to connector J1.
3.3. Source – mains part _ ringing transformer
The mains part is attached using a detachable mains lead (so-called EURO socket).
Installation manual 11
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
The lever switch located on the right side of the chassis serves for switching the power on and off.
The mains part is protected against contact with live parts by a cover which also covers the actual power source.
The ringing voltage with a frequency of 50 Hz comes directly from the mains by a so-called ringing transformer. The ringing transformer is protected from shorting by fuse T0.063A.
WARNING! This part is connected to the mains power and works with voltage which
is dangerous to life. All repairs and replacements of these parts are only made at the manufacturer!! Only the following handling is allowed:
WARNING!
Disconnect from
mains before handling!
Mains lead connection and disconnection Always perform this handling with the PBX disconnected
from the mains!!!
!!! Note: The source can be connected to equipment of the type UPS ( backup source).
Installation manual 12
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3.4. Display
The LCD display is fitted on an independent holder and connected by means of a flat cable to the motherboard. It displays the current version of the PBX firmware, the date, time and data about state of line.
Installation manual 13
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
Other separate components
4. Extender module (order No 1880010)
The extender module is intended for mounting in the basic PBX module. It enables the extension of the PBX by 12 lines (6 modules with interfaces) + insert 1 module AUDIO IN/OUT intended for example for the system IVR, automatic operator, recording of calls,…
J1 - connector for connecting motherboard. J2 – J7 - connectors for connecting line modules (description of individual
modules – see Chapter 5).
J8 - connectors for connecting module AUDIO IN/OUT (module intended
for applications: automatic operator, IVR, VoiceMail,…).
U1 - connecting cross-point array
Installation manual 14