Dear customer,
Congratulations on the purchase of the product 2N OMEGA Lite. This new product
was developed and manufactured with an emphasis on maximum user value, quality
and reliability. It is our desire that the 2N OMEGA Lite should give you complete
1880000 - basic module without modem for RemoteSupervision up to 24
lines
1880001 - basic module with modem for RemoteSupervision up to 24 lines
Installation manual 4
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
In its assembled state, each basic module contains these parts:
• chassis (metal part of mechanism) with power source
• display
• plastic cover
• motherboard with or without modem for remote supervision (RS)
• 1x platelet for power cable
• 2x blanking platelets
The following components are included:
• Wall-mounting element (part of basic module)
• Rawlplugs and screws for wall mounting
• Power cable
• Screws for fixing serial or blanking platelets
It also contains this equipment:
• CD with complete documentation and necessary SW
• Serial cable with RJ-12 terminal and one gender changer for DB-9 connector
Installation manual 5
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
Description of parts of basic module
2. Description of mechanical parts
2.1. Base (chassis)
The base carries the other parts. The power supply (plug 230V/AC + power
switch) is mounted in the upper right part. The upper left + lower left part is intended
for fitting the extender. The strip with holes in the bottom part is intended for fitting
serial and blanking platelets. The display is fixed in the upper part in the centre.
Installation manual 6
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
2.2. PBX cover
The plastic cover bears a sticker with a transparent window for the display.
The cover is fitted on the chassis by fitting into two holes in the upper part of
the plastic and is secured by two extendable “pegs” into the lower part of the plastic.
When dismantling the cover, first press (using an appropriate tool) both
extendable “pegs”, whereby you free the cover and then remove the cover.
Installation manual 7
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3. Description of electrical components
3.1. Motherboard
Installation manual 8
www.2n.cz
2N
®
1 - RTS
2 - TXD
3 - GND
4 - GND
5 - RXD
6 - CTS
Connecting
- OMEGA Lite
Installation manual
B1 - Lithium battery holder. We recommend replacement when the voltage is lower than 2.5
V, or at least once every three years. We recommend the batteries be replaced with the
PBX off. Before replacement we recommend saving the program of the PBX and the
accounting data in a PC. After replacement check the date, time and program of the
PBX and, if not correct, make the correct adjustment. Never change the batteries when
the PBX is on.
WARNING! Use only a tool made from insulating material for replacement!!!
J1 - connector for connecting extender
J2 – J7 - connectors for connecting line modules (description of modules – see Chapter 5)
J8 – J9 - shorting jumpers (connected – RS232-COM is connected to the J18 connector,
disconnected – RS232-COM is connected to the module VoIP)
J10 - company’s servicing reanimation connector (1 Hz)
J11 - connector for connecting additional memory for announcements (180 s)
J12 - shorting jumper – always fitted (activation WATCH DOG)
J13 - company’s servicing reanimation connector (SW for ALTERA)
J14 - company’s servicing reanimation connector (SW for CPU)
J15 - connector for connecting VoIP module
J16 -.connector for connecting LED signalling
J17 - connector for display
J18 - connector RJ12 with galvanic isolation for PC connection (RS232-COM).
J19 - input voltage connector – (1. +5V, 2.,4. GND, 3. +24V, 5. -24V, 6. RINGV).
J20 - voltage connector – (1. RINGV, 2. -24V, 3. GND, 4. +24V) ).
J21 - output voltage connector – (+24V DC).
J22 - input voltage connector – (+24V DC).
J23 - shorting jumper – always disconnected (only for testing purposes – connection
GND and PGND),
J24 - servicing connector (locking of FLASH memory).
J25 - line input (CINCH – AUX IN) for connecting external music source (for example
CD, radio).
SW1 - Auxiliary RESET1 button (pressing results in reset).
SW2 - Auxiliary RESET2 button (1. –setting company values (press button + switch on
PBX + confirm by pressing again after display of message “Clear config? - push
again/wait“, 2. entry to “service mode” (hold button down during test of RAM
memory).
P1 - regulating volume of line input.
U1 - governing processor
J18 – the connector is intended for connecting the PBX with a PC. It thus allows
the programming of the PBX using the program OMEGA Lite - PROGRAM, detailed
display of operation using program OMEGA Lite - PANEL, for connection of XAPI
Server, etc.
The serial port includes an insulating DC/DC converter of its own and, by
optical signal transmission, provides galvanic isolation of the serial port from the
PBX with a guaranteed insulation strength of 500 V.
This solution has the following advantages:
• Helps transmit data over long distances
• Improves data transmission reliability (resistance to disruption)
• Enables communication with a PC powered from a different power supply section
(for example, from a different phase or central UPS)
• Improves overvoltage resistance of the input
For connection with a PC, especially over a greater distance, a normal (i.e., cross-
over) four-wire telephone cord with RJ-12 terminals is normally used instead of a
special “serial cable”.
Installation manual 10
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3.2. Power supply
As the Power supply a power supply module with open construction and with
output voltage of +24VDC/2.7A (connector J2) is used. One integral part of the
supply is the cooler, which is designed for an upright working position of the PBX. It
is not allowed to operate the PBX in a horizontal position (lying on a table etc). The
source is distinguished in particular by the simplicity of connection, which is a
guarantee of the source’s maximum reliability. The source has an overvoltage fuse
(F1) F4A/250V. The power goes to connector J1.
3.3. Source – mains part _ ringing transformer
The mains part is attached using a detachable mains lead (so-called EURO
socket).
Installation manual 11
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
The lever switch located on the right side of the chassis serves for switching
the power on and off.
The mains part is protected against contact with live parts by a cover which
also covers the actual power source.
The ringing voltage with a frequency of 50 Hz comes directly from the mains by
a so-called ringing transformer. The ringing transformer is protected from shorting by
fuse T0.063A.
WARNING! This part is connected to the mains power and works with voltage which
is dangerous to life. All repairs and replacements of these
parts are only made at the manufacturer!! Only the
following handling is allowed:
WARNING!
Disconnect from
mains before handling!
• Mains lead connection and disconnection
Always perform this handling with the PBX disconnected
from the mains!!!
!!! Note: The source can be connected to equipment of the type UPS ( backup
source).
Installation manual 12
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
3.4. Display
The LCD display is fitted on an independent holder and connected by means
of a flat cable to the motherboard. It displays the current version of the PBX
firmware, the date, time and data about state of line.
Installation manual 13
www.2n.cz
2N
®
- OMEGA Lite
Installation manual
Other separate components
4. Extender module (order No 1880010)
The extender module is intended for mounting in the basic PBX module. It
enables the extension of the PBX by 12 lines (6 modules with interfaces) + insert 1
module AUDIO IN/OUT intended for example for the system IVR, automatic
operator, recording of calls,…
J1 - connector for connecting motherboard.
J2 – J7 - connectors for connecting line modules (description of individual
modules – see Chapter 5).
J8 - connectors for connecting module AUDIO IN/OUT (module intended
for applications: automatic operator, IVR, VoiceMail,…).
U1 - connecting cross-point array
Installation manual 14