Installation Manual
UIB-01
©
Zoom Corporation
Reproduction of this manual, in whole or in part, by any means, is
prohibited.
3
ZOOM UIB-01
Contents
Contents
2
ZOOM UIB-01
Safety Precautions / Software License
Safety Precautions
In this manual, important information that is
intended to prevent the danger of injury to
persons and damage to equipment is marked
with special symbols. The meaning of these
symbols is explained below.
Disregarding instructions printed
here incurs the risk of death or
severe injury to persons.
Disregarding instructions printed
here incurs the risk of injury to
persons and/or damage to
peripheral equipment.
Please observe the following safety tips and
precautions to ensure hazard-free use of the
UIB-01.
■ Handling
●Before installing the UIB-01 in the
MRS-1044, be sure to turn the MRS1044 off and disconnect the AC
adapter from the outlet.
●Before handling the UIB-01, touch a
grounded metal surface or take other
measures to discharge any buildup
of static electricity. Otherwise static
discharge can damage the UIB-01 or
MRS-1044.
●The UIB-01 is a precision product.
Do not subject it to strong force when
installing it in the MRS-1044. To
prevent the possibility of damage,
take care not to drop it and protect it
from shocks.
●Only install the UIB-01 according to
the instructions in this manual. Any
damage or malfunction arising from
improper installation is not covered
by the warranty.
●Never attempt to modify this product
in any way. Any damage or
malfunction arising from
modification attempts is not covered
by the warranty
■ Malfunction
If there is any malfunction or other sign of a
problem, immediately turn off the MRS1044, disconnect the AC adapter from the
outlet, and remove the UIB-01.
Note the model number, serial number,
symptoms, as well as name of the dealer
where the product was purchased, and contact
Zoom Corporation, providing your name,
address, and telephone number.
Software License
The CD-ROM supplied with this product
contains software programs (hereafter called
"the software") required to use the product.
Zoom Corporation grants you the right to
use the software, provided that you agree
with all conditions listed below. Using the
software is considered acceptance of this
agreement.
● Zoom Corporation holds the copyright to
the software and the accompanying
documentation, and all associated rights.
All rights revert to Zoom Corporation.
● Unauthorized redistribution, sale, leasing,
renting, alteration, and reverse engineering
of the software is prohibited.
● The software may not be used for purposes
that infringe on the copyright of third
parties. Zoom Corporation does not bear
liability for cases where the software is
used for any such purpose.
● Zoom Corporation does not bear liability
for any damages or claims from third
parties arising from the use of the software,
whether directly or indirectly. If the
contents of a hard disk are lost due to use
of the software, Zoom Corporation does
not accept any claims for restoring or
preserving such contents.
●
Features and specifications of the software
and the contents of the documentation may
be changed in future without notice.
Safety Precautions / Software License •••••••••••••••••••••••• 2
Introduction ••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 4
About the UIB-01 •••••••••••••••••••••••••••••••••••••••••••••••••• 4
Operation Environment •••••••••••••••••••••••••••••••••••••••••••• 5
Explanations in the manual ••••••••••••••••••••••••••••••••••••••• 5
Preparations •••••••••••••••••••••••••••••••••••••••••••••••••••••••• 6
Installing the UIB-01 ••••••••••••••••••••••••••••••••••••••••••••••• 6
Connection between computer and MRS-1044 ••••••••••••••••• 8
Installing the driver •••••••••••••••••••••••••••••••••••••••••••••••• 9
Windows 98 driver installation •••••••••••••••••••••••••••••••••••••• 9
Windows Me driver installation ••••••••••••••••••••••••••••••••••• 13
Windows 2000 driver installation •••••••••••••••••••••••••••••••••• 15
Check whether computer and MRS-1044 are in the online state
• 18
Terminating the connection between computer and MRS-1044
•• 19
UIB-01 Applications •••••••••••••••••••••••••••••••••••••••••••••• 21
Project backup / restore ••••••••••••••••••••••••••••••••••••••••• 21
Backing up a project ••••••••••••••••••••••••••••••••••••••••••••• 21
Restoring a project ••••••••••••••••••••••••••••••••••••••••••••••• 22
Returning the MRS-1044 to the factory default condition ••••• 24
Formatting the hard disk of the MRS-1044 •••••••••••••••••••••••• 24
Using the Factory Recorvery Tool ••••••••••••••••••••••••••••••••• 25
Using the Audio File Manager ••••••••••••••••••••••••••••••••••• 26
Installing the software •••••••••••••••••••••••••••••••••••••••••••• 26
Starting the Audio File Manager ••••••••••••••••••••••••••••••••••• 26
Reference Information •••••••••••••••••••••••••••••••••••••••••• 28
MRS-1044 hard disk contents ••••••••••••••••••••••••••••••••••• 28
Contents of the supplied CD-ROM ••••••••••••••••••••••••••••• 29
Troubleshooting •••••••••••••••••••••••••••••••••••••••••••••••••• 31
• Microsoft and Windows are registered trademarks of Microsoft
Corporation in the U.S.A. and in other countries.
• Apple and the Apple logo are registered trademarks of Apple Computer.
• Macintosh is a registered trademark of Apple Computer.
• Pentium is a registered trademark of Intel Corporation.
• All other trademarks, product names, and company names are the property
of their respective owners.
Warning
Warning
5
ZOOM UIB-01
Introduction
Operating Environment
The UIB-01 has the following hardware and software requirements.
●
Computer
Windows computer running Windows 98/Me/2000 and equipped
with
a USB connector (Pentium 166 MHz or higher recommended)
*
The
Apple Macintosh series of computers are not supported.
●
Free hard disk space
100 MB or more (plus space for converted data etc.)
●
RAM
32 MB or more
●
Supported operating systems
• Microsoft
®
Windows®98 (hereafter called "Windows 98")
• Microsoft
®
Windows®Millennium Edition (hereafter called
"Windows Me")
• Microsoft
®
Windows®2000 Professional (hereafter called "Windows
2000")
●
Other requirements
• CD-ROM drive x 1
• USB cable x 1
Even when the above requirements are met, correct operation on
all types of computers is not assured. Depending on individual
specifications and system conditions, there may be cases where
incompatibilities exist.
Explanations in the manual
Most explanations in this manual apply equally to all supported operating
systems (Windows 98/Windows Me/Windows 2000). In general,
explanations are based on Windows 98, and exceptions are noted when
there are differences for the other operating systems.
4
ZOOM UIB-01
Introduction
Introduction
Thank you for selecting the ZOOM USB Interface Board UIB-01
(hereafter called the "UIB-01"). To ensure correct use of this product,
please read and follow all instructions contained in this manual.
About the UIB-01
The UIB-01 is a Windows compatible USB interface board designed for
installation in the ZOOM MultiTrak Recording Studio MRS-1044
(hereafter called "MRS-1044"). When the UIB-01 is installed in the
dedicated slot of the MRS-1044, data exchange between a computer and
the MRS-1044 becomes possible, and the following functions are
available.
●
Project backup/restore
You can copy any project of the MRS-1044 to the hard disk of the
computer. This is convenient for creating backups of important
projects. A backed-up project can be restored to the MRS-1044 at any
time.
●
V-take/audio file conversion
Using the software on the supplied CD-ROM, you can convert any
V-take of the MRS-1044 into a WAV file, or convert existing
WAV/AIFF files into V-takes of the MRS-1044.
●
MRS-1044 initialization
The supplied CD-ROM contains data about the factory default settings
of the MRS-1044. Using software also contained on the CD-ROM, you
can reset the MRS-1044 at any time to the factory default condition.
●
System update
When there are operating system upgrades for the MRS-1044 in future,
you can simply copy the relevant system files from the computer to the
MRS-1044, to update the system.
7
ZOOM UIB-01
Preparations
2.
With the populated side of the UIB-01 board (the side with
IC chips and other components) facing downwards, push
the UIB-01 fully into the slot.
Align the board with the rails of the slot, and make sure that it clicks
into place. If the board does not go all the way in, check whether the
UIB-01 has not been inserted upside down, and whether it is
properly aligned with the rails.
3.
Use the screws removed in step 1 to fasten the UIB-01.
6
ZOOM UIB-01
Preparations
Preparations
This section describes how to install the UIB-01 in the MRS-1044, and
how to install the driver software on the computer. These steps are
required before the UIB-01 can be used.
Installing the UIB-01
The UIB-01 is designed for installation in the side panel slot of the MRS-
1044.
Before installing the UIB-01 in the MRS-1044, be
sure to turn the MRS-1044 off and disconnect the
AC adapter from the outlet.
1.
Remove the two screws that fasten the cover of the side
panel slot, and remove the cover.
These screws will be used to fasten the UIB-01.
9
ZOOM UIB-01
Preparations
Installing the driver
To allow the computer to recognize the MRS-1044 properly, a driver
must be installed. The steps for installing the driver differ for the various
operating systems. Please refer to the appropriate page, as shown below.
Windows 98 → this page / Windows Me → p.13 / Windows 2000 → p.15
Windows 98 driver installation
1.
Verify that the following indication is shown on the
computer display, then click on the [Next] button.
* If the indication is not shown → p.31
2.
Place a check mark in "Search for the best driver..." on the
next screen, and click on the [Next] button.
8
ZOOM UIB-01
Preparations
Connection between computer and
MRS-1044
1.
Turn power to the computer on and start Windows 98/Me/2000.
2.
Insert the CD-ROM supplied with the UIB-01 into the CDROM drive of the computer.
3.
Double-click on the "My Computer" icon and check the
drive letter of the drive where the CD-ROM (volume label
"UIB_01_CD") is inserted.
In the following explanation, the drive will be called "E", but this
may be different for your computer.
For systems running Windows 98 or Windows 2000, the CD-ROM
drive letter will be required when installing the driver software. Make
a note of the drive letter.
4.
While holding down the [CLEAR] key of the MRS-1044, press
the [POWER] switch on the rear panel to turn the MRS-1044 on.
This starts up a special utility program contained in the internal ROM
of the MRS-1044. When the indication "ROM UTY MRS-1044"
appears on the display of the MRS-1044, release the [CLEAR] key.
5.
Press the [AUTO PUNCH IN/OUT] key of the MRS-1044.
The MRS-1044 goes into USB mode, and the indication "USB
WORKING" is shown on the display of the MRS-1044. In this mode,
the MRS-1044 operates as a USB device.
6.
Connect the computer and the MRS-1044 (UIB-01) with a
USB cable.
A message for installing the driver appears on the display of the
computer.
11
ZOOM UIB-01
Preparations
5.
After a while, the following screen will be shown. Click on
the [Finish] button.
6.
After a while, the following screen will be shown. Click on
the [Next] button.
7.
Place a check mark in "Search for the best driver..." on the
next screen, and click on the [Next] button (same as step 2).
8.
Place a check mark in "Specify a location " on the next
screen, enter "[CD-ROM drive letter]:\", and click on the
[Next] button (same as step 3).
10
ZOOM UIB-01
Preparations
3.
Place a check mark in "Specify a location " on the next
screen, enter "[CD-ROM drive letter]:\", and click on the
[Next] button.
The following example uses the drive letter "E".
4.
Verify that the following indication is shown, and click on
the [Next] button.