Zephyr ZMOM90BS, ZMOE30BS Use, Care, and Installation Guide

0 (0)

WWW.ZEPHYRONLINE.COM

Modena

ZMO-E30BS, ZMO-M90BS

EN Use, Care, and Installation Guide

FR Guide d’utilisation, d’entretien et d’installation

C TM

Airflow Control Technology

SEP20.0301

CORE

MODENA

WALL

2

Modena Use, Care, and Installation Guide

 

Contents

ZEPHYRONLINE.COM

 

 

Page

Safety Information ............................................................................

4-9

Types of Safety Warnings...................................................................

4

General Safety..................................................................................

5-8

Operation...........................................................................................

8

Electrical Requirements .....................................................................

8-9

List of Materials..................................................................................

10

Installation Instructions....................................................................

11-20

Ducting Calculation Sheet..................................................................

11

Mounting Height, Clearance, & Ducting ..........................................

12-13

Ducting Options .................................................................................

14

Hood Specifications............................................................................

15

Electrical Supply.................................................................................

16

Cable Lock .........................................................................................

16

Mounting the Hood...........................................................................

17-18

Ductless Recirculation ........................................................................

19

Recirculating Kit Installation ............................................................

19-20

Features & Controls..........................................................................

21-22

ICON Touch Controls.......................................................................

21-22

Maintenance ...................................................................................

23-24

Hood & Filter Cleaning.....................................................................

23-24

ACT™ Conversion............................................................................

25-27

Airflow Control Technology (ACT™) ...................................................

25

Enabling ACT™................................................................................

26-27

Wiring Diagram...............................................................................

28-29

Troubleshooting................................................................................

30-31

List of Parts & Accessories ..................................................................

32

Notes...............................................................................................

33-34

Limited Warranty ...............................................................................

35

Product Registration...........................................................................

36

Modena Use, Care, and Installation Guide

3

Safety Information

CORE

MODENA

WALL

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages.

This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe

bodily injury or death. All safety messages will follow the Safety Alert Symbol and either the words “DANGER” “WARNING” or “CAUTION”

DANGER

Danger means that failure to heed this safety statement may result in severe injury or death.

WARNING

Warning means that failure to heed this safety statement may result in extensive product damage, serious personal injury, or death.

CAUTION

Caution means that failure to heed this safety statement may result in minor or moderate personal injury, property or equipment damage.

4

Modena Use, Care, and Installation Guide

Safety Information

ZEPHYRONLINE.COM

READ AND SAVE THESE INSTRUCTIONS

General Safety

WARNING

To reduce the risk of fire or electric shock, do not use this fan with any solid-state control device.

WARNING

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a)Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b)Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION

For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.

Modena Use, Care, and Installation Guide

5

Safety Information

READ AND SAVE THESE INSTRUCTIONS

CORE

MODENA

WALL

WARNING

WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

a)SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b)NEVER PICK UP A FLAMING PAN – You may be burned.

c)DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

d)Use an extinguisher ONLY if:

1)You know you have a Class ABC extinguisher, and you already know how to operate it.

2)The fire is small and contained in the area where it started.

3)The fire department is being called.

4)You can fight the fire with your back to an exit

aBased on “Kitchen Firesafety Tips” published by NFPA.

6

Modena Use, Care, and Installation Guide

Safety Information

ZEPHYRONLINE.COM

READ AND SAVE THESE INSTRUCTIONS

WARNING

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a)Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

b)Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

c)When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

d)Ducted fans must always be vented to the outdoors.

e)If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

Modena Use, Care, and Installation Guide

7

Safety Information

READ AND SAVE THESE INSTRUCTIONS

CORE

MODENA

WALL

CAUTION

ŹTo reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

ŹNot for use over an outdoor grill.

ŹFor indoor use only.

Operation

ŹAlways leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

ŹThe manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

Electrical Requirements

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility to be aware of these below:

ŹTo contact a qualified electrical installer.

ŹTo assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

8

Modena Use, Care, and Installation Guide

Safety Information

ZEPHYRONLINE.COM

READ AND SAVE THESE INSTRUCTIONS

ŹIf codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

ŹDo not ground to a gas pipe.

ŹCheck with a qualified electrician if you are not sure the range hood is properly grounded.

ŹDo not have a fuse in the neutral or ground circuit.

ŹThis appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.

ŹA cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.

* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

WARNING

Prop. 65 Warning for California Residents: This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Modena Use, Care, and Installation Guide

9

List of Materials

CORE

MODENA

WALL

 

Parts Supplied

 

 

Quantity

Part

1

Hood with internal blower

1

Aluminum mesh filter

2LumiLight LED, 6W (pre-installed) (ZMO-E30BS)

4LumiLight LED, 6W (pre-installed) (ZMO-M90BS)

1

Duct cover assembly (top and bottom)

1

 

Duct cover wall bracket

1

8” round backdraft damper (pre-installed)

1

 

Hardware package

M3.5 x 8 (2)

#6 x 1-1/2” (3)

#6 x 1” (2)

ø12 OD / ø5 ID (1)

Wire Nuts (3)

3/16 x 3/8 (2)

 

 

Washer

Parts Not Supplied

Ducting, conduit and all installation tools

Cable locking connector (if required by local codes)

Duct cover extension kit

Recirculating kit

10

Modena Use, Care, and Installation Guide

Zephyr ZMOM90BS, ZMOE30BS Use, Care, and Installation Guide

Installation Instructions

ZEPHYRONLINE.COM

Ducting Calculation Sheet

Duct pieces

Equivalent number

Total

 

length x used

 

=

3-1/ 4” x 10”

1

Ft.

x (

)

=

Ft.

Rect.,

 

 

 

 

 

 

straight

 

 

 

 

 

 

6”, 7”, 8”, 10”

1

Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

 

straight

 

 

 

 

 

 

3-1/ 4” x 10”

15

Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

 

elbow

 

 

 

 

 

 

3-1/ 4” x 10”

9 Ft.

x (

)

=

Ft.

Rect.450

 

 

 

 

 

 

elbow

 

 

 

 

 

 

3-1/ 4” x 10”

24 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

 

flatelbow

 

 

 

 

 

 

7” to 6” or

25 Ft.

x (

)

=

Ft.

8” to 7” Round

 

 

 

 

 

tapered

 

 

 

 

 

 

reducer

 

 

 

 

 

 

6”, 7“, 8”

15

Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

 

in-line

 

 

 

 

 

 

damper

 

 

 

 

 

 

6”, 7”, 8”, 10”

15 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

 

900 elbow

 

 

 

 

 

 

6”, 7”, 8”, 10”

9 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

 

450 elbow

 

 

 

 

 

 

 

Subtotal column1 =

Ft.

Maximum Duct Length: For satisfactory air movement, the totalductlengthshould not exceed 150 equivalent feet.

Duct pieces

Equivalent number

Total

 

length x used

 

=

3-1/ 4” x 10”

5 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

3-1/ 4” x 10”

20 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

6” roundto

1 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

6” roundto

16 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

7” roundto

8 Ft.

x (

)

=

Ft.

3 1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

7” roundto

23 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

3-1/ 4” x 10”

30 Ft.

x (

)

=

Ft.

Rect.

 

 

 

 

 

wall cap

 

 

 

 

 

withdamper

 

 

 

 

 

6”, 7”, 8”, 10”

30 Ft.

x (

)

=

Ft.

Round, wall

 

 

 

 

 

cap with

 

 

 

 

 

damper

 

 

 

 

 

6”, 7”, 8”, 10”

30 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

roof cap

 

 

 

 

 

Subtotal column2 =

Ft.

Subtotal column1 =

 

Ft.

Total ductwork =

 

Ft.

Modena Use, Care, and Installation Guide

11

CORE

Installation Instructions

Mounting Height, Clearance, & Ducting

 

 

 

 

.

A

 

 

 

min

B

 

 

 

.

 

 

 

min

C

 

.

D

 

.

 

max

 

 

 

 

min

E

 

 

.

 

 

 

 

 

 

min

F

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

max

 

 

 

 

 

 

 

 

.

 

 

 

 

 

min .

 

 

 

 

24” max

 

 

 

 

 

34”

 

 

 

36”

MODENA

WALL

 

Standard

Extension

Hood Heights

Duct Cover

Duct Cover

minimum ducted (A)

27”

41-1/2

minimum recirculating (B)

31”

45-1/2

maximum (C)

50”

80”

Ceiling Heights

 

 

minimum ducted (D)

87” (7’ 3”)

101-1/2“ (8‘ 5-1/2”)

minimum recirculating (E)

91” (7’ 7”)

105-1/2“ (8‘ 9-1/2”)

maximum (F)

120” (10’ )

150” (12’ 6”)

 

 

 

12

Modena Use, Care, and Installation Guide

Installation Instructions

ZEPHYRONLINE.COM

Mounting Height, Clearance, & Ducting

A minimum of 8” round duct is recommended to maintain maximum air flow efficiency.

Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.

Use calculation worksheet to compute total duct work (Page 11).

ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”.

If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible.

Minimum mount height between range top to hood bottom should be no less than 24”.

Maximum mount height should be no higher than 34”.

It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.

If available, also refer to range manufacturer’s height clearance requirements and recommended hood mounting height above range. Always check your local codes for any differences.

Duct cover extension kit available for ceiling heights up to 12 feet. Turn to the List of Parts and Accessories section for part number and ordering information.

For shipment and installation damages:

ŹPlease fully inspect unit for damage before installation.

ŹIf the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.

ŹIf the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

ŹIf the unit is damaged by the installer (if other than the customer), repair of replacement must be made by arrangement between customer and installer.

Modena Use, Care, and Installation Guide

13

Installation Instructions

Ducting Options

CORE

MODENA

WALL

WARNING

Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option.

ŹUse single wall rigid metal ductwork only.

ŹFasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.

roof pitch w/

 

flashing & cap

 

(blower

side wall cap

housing)

(blower

w/ gravity

housing)

damper

 

soffit or crawl space

 

 

 

 

 

 

 

 

 

ductless

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(blower recirculating

 

side wall cap

housing)

 

w/ gravity damper

 

 

(blower

housing)

14

Modena Use, Care, and Installation Guide

Installation Instructions

ZEPHYRONLINE.COM

Ů

Front of Hood

 

13-3/8”

 

11-13/16”

 

 

<![if ! IE]>

<![endif]>6-5/16”

<![if ! IE]>

<![endif]>16-15/16”

<![if ! IE]>

<![endif]>3/16”

 

<![if ! IE]>

<![endif]>1-

29-15/16”, 35-7/16”

 

Side of Hood

12-3/8”

STANDARD

min. ducted - 27” min. recirc. - 31” max. - 50”

Z1C-00MO

min. ducted - 41-1/2” min. recirc. - 45-1/2” max. - 80”

22-1/8”

 

Top of Hood

 

<![if ! IE]>

<![endif]>4-5/8”

 

 

<![if ! IE]>

<![endif]>-511/16”

AC In

7-

 

 

3/4”

Modena Use, Care, and Installation Guide

15

Installation Instructions

Electrical Supply

WARNING

CORE

MODENA

WALL

Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring.

For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.

Follow national electrical codes or prevailing local codes and ordinances.

This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.

Cable Lock

A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)

2

Cable Lock

1

3

Motor Housing

FIG. A

16

Modena Use, Care, and Installation Guide

Installation Instructions

ZEPHYRONLINE.COM

Mounting the Hood

CAUTION

C/L

 

 

 

 

 

Duct Cover

At least two installers are required due to the

11-1/4”

Bracket

 

weight and size of the hood.

B

 

1. Measure from range top to hood bottom and

 

17-1/2”

mark line A. (24” minimum from range top) .

 

 

 

2. Plum and mark center line.

A

 

 

 

3. Mark mounting height line B. (17-1/2” from line

 

24” min.

 

 

A)

C/L

 

 

 

4. Mark mounting spread from C/L. (11-1/4”)

5.Fasten (2) #6 x 1-1/2” screws into studs on line B

but do not tighten all the way.

NOTE: Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes for compliance. Failure to use suitable wall anchors and screws to hold the weight

of the hood could result in personal injury or damage to cooking surface or counter.

6.Remove tape and (2) screws securing electronics mounting bracket to hood. Reposition electronics mounting bracket as shown in FIG. A3 and secure to motor housing using the (2) previously removed screws.

Brackets are pre-installed

1

2

FIG. B

Modena Use, Care, and Installation Guide

17

Installation Instructions

Mounting the Hood

CORE

MODENA

WALL

7.Remove (2) screws securing electrical junction box to electronics mounting plate. Remove junction box shown in FIG. A1

8.Remove the (1) aluminum mesh filter.

9.Hang hood onto the mounting screws and hand tighten each screw. (FIG. B) Secure third #6 x 1-1/2” screw through inside of hood into wall for extra support shown in FIG. B2.

10.Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using (2) #6 x 1” screws.

11.Install duct work and seal duct work with aluminum duct tape. Reinstall electrical junction box with cable lock and install the electrical shown in FIG. A2.

12.Power up hood and check for leaks around duct tape.

13.Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to duct cover bracket using (2) M3.5 x 8 screws.

* If using hood in recirculating mode you must secure the air diverter plate onto wall before installing duct work and duct covers. Turn to the Ductless Recirculation section for more details.

18

Modena Use, Care, and Installation Guide

Installation Instructions

ZEPHYRONLINE.COM

Ductless Recirculation

Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its part number below. The standard mesh filters are intended to capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from cooking for recirculation.

Recirculating Kit Installation (required if no ducting is used)

Kit includes the charcoal filters and the air diverter plate.

Hood Model

Part Number

Filters in Package

ZMO-E30BS

ZRC-00MO

1

ZMO-M90BS

ZRC-00MO

1

1.Purchase recirculating kit per the part number above.

2.Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run 8” ducting from top of hood and secure to air diverter plate. See manual included with recirculating kit for more detailed instructions.

3.Remove aluminum mesh filter from hood. Install charcoal filter bracket inside filter opening. Note: screws to secure charcoal filter bracket are already pre-installed in the hood and must first be removed. Clip charcoal filters onto charcoal filter bracket. (FIG. C)

4.Re-Install aluminum mesh filter.

Modena Use, Care, and Installation Guide

19

Installation Instructions

5.Enable charcoal filter change indicator on control panel. (Refer details to pg. 22)

6.Charcoal filters must be replaced after every 120 hours of use (or approximately every 3 to 4 months based on the average of 1 - 2 hours of daily cooking time). The microprocessor in the controls when set, will elapse and count usage time and indicate when charcoal filter replacement is required every 120 hours.

Charcoal Filter Replacements

Hood Model

Part Number

Quantity to

Order

 

 

ZMO-E30BS

Z0F-C002

1

ZMO-M90BS

Z0F-C002

1

DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need to be changed more often depending on cooking habits.

CORE

MODENA

WALL

FIG. C

20

Modena Use, Care, and Installation Guide

Features & Controls

ZEPHYRONLINE.COM

ICON Touch Controls

Power / Delay Off

Adjust 5 Speed Levels

Lights Low/High/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display (speed level, delay off, filter clean/change)

1 POWER / DELAY OFF BUTTON Power Button Function

- Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at.

(Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.)

Delay Off Button Function

-With the fan on press and hold the Button for two seconds. The fan will change to speed 1 and the 5 minute delay off timer will start.

+ LEDs will illuminate and slowly blink in

accordance with the time remaining until the fan and lights automatically turn off.

-Pressing Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function.

ACT™ Verification

- Airflow Control Technology (ACT™) allows the installer to set the maximum fan CFM to align with local codes and regulations.

-To verify the maximum fan CFM:

-With hood off, hold the Button for two seconds. If all five fan speed indicators illuminate = default maximum CFM. If four fan speed indicators illuminate = 390 maximum CFM. If 3 fan speed indicators illuminate = 290 maximum CFM.

2 SPEED SELECTION BUTTON

Fan Speed Decrease Button

-Press this button to decrease fan speed. 5, 4, 3, 2, 1.

-If fan is On Speed 1 and this button is pressed, fan will power Off.

Fan Speed Increase Button

-Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.

-If hood is Off and this button is pressed, fan will turn On Speed 1.

ACT™ Enabled Speed Selections

-When ACT™ is enabled, the number of fan speeds will be reduced as follows:

-390 CFM = Maximum 4 speeds

-290 CFM = Maximum 3 speeds

Modena Use, Care, and Installation Guide

21

CORE

Features & Controls

MODENA

WALL

ICON Touch Controls

3LIGHTS BUTTON

-Lights have two levels, Low and High.

-From off, press one time for Low. Press again for High. Press again to power lights off.

4 DISPLAY INDICATORS

Charcoal Filter Replace Indicator (disabled by default, must be enabled if recirculating hood)

-To enable Charcoal Filter Replacement Reminder:

-With hood off, holdbutton and button simultaneously for two seconds. All LED indicators will illuminate for three seconds confirming the Charcoal Filter Replace Reminder is enabled.

-To disable Charcoal Filter Replacement Reminder:

-With hood off, holdbutton and button simultaneously for two seconds. All LED indicators will blink two times confirming the Charcoal Filter Replace Reminder is disabled.

-After 120 hours of fan usage thebutton will slowly blink indicating the charcoal filters need replacment.

-To reset: With hood off, hold thebutton for two seconds. All LED indicators will blink two times confirming the 120 hour timer has been reset.

22

Modena Use, Care, and Installation Guide