Zephyr DBI600A User Manual

4 (1)

Model DBI-600A

Page 1

For use with these Downdraft Ventilators: ZEPHYR Models: DLI-E30ASX, DLI-E36ASX

(Purchase Downdraft Ventilator separately.)

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.To reduce the risk of fire, use only metal ductwork.

8.Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches.

9.Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop.

10.Children should not be left alone or unattended in the area where this appliance is in use.

11.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when cooking flaming foods.

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher, and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

a Based on “Kitchen Firesafety Tips” published by NFPA.

CAUTION !

1.For indoor use only.

2.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

3.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4.Clean filters and grease-laden surfaces frequently.

5.Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician.

6.Please read specification label on product for further information and requirements.

7.To reduce the risk of fire and electric shock, install this blower only with downdraft ventilator models shown below. Other downdraft ventilator models cannot be substituted. (Downdraft ventilators sold separately).

ZEPHYR Models DLI-E30ASX, DLI-E36ASX

INSTALLER:

Save this manual for Electrical Inspector and Homeowner to use.

Zephyr DBI600A User Manual

CONTENTS

These parts are included with your DBI-600A blower: 2 - blower mounting legs*

1 - Parts Bag containing:

(4) wood screws #10 x .50*

(4) blower mount brackets

(1) strain relief bushing

(8) screws #10 x .38

(8)nuts #10

*For use when mounting DBI-600A blower directly to Downdraft housing. (See Downdraft instruction manual.)

PLAN THE INSTALLATION

If you choose to mount the blower directly to the Downdraft housing: Remove the inlet cover (taped in place for shipping) and discard inlet cover. Refer to installation instructions in the Downdraft manual.

If you choose to mount the blower in a remote location, (such as the cabinet back, cabinet side, or floor joists) - follow the instructions below.

INSTALL BLOWER

IN REMOTE LOCATION

NOTE:THEBLOWERMUSTBEINSTALLEDWITHIN4-FEETOF THEDOWNDRAFT’SELECTRICALPANEL.The Electrical Panel can be mounted directly to the Downdraft housing - or mounted in a remote location (always within 4-feet of the Flex Blower).

BLOWER

INLET

COVER

OUTLET

 

(to roof cap or wall cap)

INLET (from downdraft)

1.Position inlet cover over blower wheel. Securely attach the inlet cover to the blower with 8 screws and 8 nuts from parts bag. Note that inlet cover is taped to blower for shipping. This tape may be removed.

2.Determine how the 8” round INLET and OUTLET ductwork will connect to the blower.

Model DBI-600A

Page 2

(4) MOUNTING BRACKETS attached with 1/4-20 X .50 HEX HEAD SCREWS

(6) MOUNTING

BRACKET

LOCATIONS

3.Remove the necessary 1/4-20 x .50 hex head screws and attach 4 MOUNTING BRACKETS to the blower - using 4 of the 6 POSSIBLE BRACKET MOUNTING LOCATIONS.

 

MOUNTING SCREWS

 

(not included)

 

8-IN.

 

ROUND

8-IN.

DUCT

ROUND

(to roof cap

DUCT

or wall cap)

(from

 

downdraft)

 

4.Mount blower to back of cabinet, floor joist, or adequate framework (constructed by installer) with appropriate

MOUNTING SCREWS (not included).

5.Connect 8” ROUND DUCT from Downdraft housing to blower inlet and from blower outlet to roof or wall cap.

For best performance:Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference.

6.Use strain relief bushing (provided) to attach blower wiring to wiring box on Downdraft’s electrical panel and make wiring connections. (See Downdraft manual for instructions.)

99046136 / 99045244