<![endif]>Use, Care, and Installation Guide
www.zephyronline.com
Breeze I
AK1124x, AK1100x, AK1136x
Breeze II
AK1200x, AK1236x
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
FEB08.0201 © Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com
SAFETY NOTICE ................................................................. |
2-3 |
LIST OF MATERIALS....................................................... |
4 |
INSTALLATION |
|
Ducting Calculation Sheet....................................... |
5 |
Mounting Height & Clearance................................ |
6 |
Ducting Options ........................................................... |
7 |
Specifications ............................................................... |
8 |
Preparing Electrical.................................................... |
9 |
Preparing Electrical and Ducting.......................... |
10 |
Converting to Air Recirculating Mode................. |
11-12 |
Mounting the Range Hood ............................. |
13 |
FEATURES & CONTROLS |
|
Controls & Features................................................... |
14 |
MAINTENANCE |
|
Cleaning and Filter Removal.................................. |
15 |
Lights................................................................................ |
16 |
TROUBLESHOOTING................................................................ |
17 |
LIST OF PARTS AND ACCESSORIES .............................. |
18 |
<![endif]>Table of Contents
1
<![endif]>Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS |
www.zephyronline.com |
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a.Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b.Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b.Always turn hood ON when cooking at high heat or when flaming food
c.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d.Use proper pan size. Always use cookware appropriate for the size of the surface element.
e.Keep fan, filters and grease laden surfaces clean.
f.Use high setting on hood only when necessary.
g.Don’t leave hood unattended when cooking.
h.Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b.NEVER PICK UP A FLAMING PAN – You may be burned.
c.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.Use an extinguisher ONLY if:
1.You know you have a Class ABC extinguisher, and you already know how to operate it.
2.The fire is small and contained in the area where it started.
3.The fire department is being called.
4.You can fight the fire with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Including fire-rated construction.
b.Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
c.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.Ducted fans must always vent to the outdoors.
e.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI (Ground Fault Interrupter protected branch circuit).
g.NEVER place a switch where it can be reached from a tub or shower.
h.Make sure the power is off before installing, wiring or maintenancing.
2
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
OPERATION
Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
-To contact a qualified electrical installer.
-To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range hood is properly grounded. Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.
<![endif]>Important Safety Notice
3
www.zephyronline.com
<![endif]>List of Materials
MODELS: BREEZE I AND BREEZE II
PARTS SUPPLIED
1 - Hood
2 - Metal Mesh Filters
2 - Incandescent Light Bulbs (R16 40W)
1 - 3-1/4”x10” Rectangular starting collar with damper 1 - Hardware package
HARDWARE PACKAGE CONTENTS
M4 x 2” (4)
M4 x 1-1/2” (4)
M4 x 1” (4)
M4 x 8 (4) |
wood screw washers (4) |
|
Wire Caps (3) |
PARTS NOT SUPPLIED
-Ducting, conduit and all installation tools
-Cable connector (if required by local codes)
-Recirculating Kit
4
Duct pieces |
Equivalent number |
|
Total |
||
|
length x used |
= |
|
||
3-1/ 4” x 10” |
1 Ft. |
x ( |
) |
= |
Ft. |
Rect., |
|
|
|
|
|
straight |
|
|
|
|
|
6” Round, |
1 Ft. |
x ( |
) |
= |
Ft. |
straight |
|
|
|
|
|
7”-10” Round, |
1 Ft. |
x ( |
) |
= |
Ft. |
straight |
|
|
|
|
|
3-1/ 4” x 10” |
15 Ft. |
x ( |
) |
= |
Ft. |
Rect.900 |
|
|
|
|
|
elbow |
|
|
|
|
|
3-1/ 4” x 10” |
9 Ft. |
x ( |
) |
= |
Ft. |
Rect.450 |
|
|
|
|
|
elbow |
|
|
|
|
|
3-1/ 4” x 10” |
24 Ft. |
x ( |
) |
= |
Ft. |
Rect.900 |
|
|
|
|
|
flat elbow |
|
|
|
|
|
3-1/ 4” x 10” |
30 Ft. |
x ( |
) |
= |
Ft. |
Rect. |
|
|
|
|
|
wall cap |
|
|
|
|
|
with damper |
|
|
|
|
|
3-1/ 4” x 10” |
5 Ft. |
x ( |
) |
= |
Ft. |
Rect.to |
|
|
|
|
|
6” round |
|
|
|
|
|
transition |
|
|
|
|
|
3-1/ 4” x 10” |
20 Ft. |
x ( |
) |
= |
Ft. |
Rect.to |
|
|
|
|
|
6” round |
|
|
|
|
|
transition |
|
|
|
|
|
900 elbow |
|
|
|
|
|
6” Round, |
15 Ft. |
x ( |
) |
= |
Ft. |
900 elbow |
|
|
|
|
|
6” Round, |
9 Ft. |
x ( |
) |
= |
Ft. |
450 elbow |
|
|
|
|
|
|
Subtotal column 1 = |
Ft. |
Duct pieces |
Equivalent number |
Total |
|||
|
length x used |
|
= |
||
6” Round |
30 Ft. |
x ( |
) |
= |
Ft. |
wall cap |
|
|
|
|
|
with damper |
|
|
|
|
|
6” Round, |
30 Ft. |
x ( |
) |
= |
Ft. |
roof cap |
|
|
|
|
|
6” round to |
1 Ft. |
x ( |
) |
= |
Ft. |
3-1/ 4” x 10” |
|
|
|
|
|
rect. |
|
|
|
|
|
transition |
|
|
|
|
|
6” round to |
16 Ft. |
x ( |
) |
= |
Ft. |
3-1/ 4” x 10” |
|
|
|
|
|
rect. |
|
|
|
|
|
transition |
|
|
|
|
|
900 elbow |
|
|
|
|
|
7” - 10” |
15 Ft. |
x ( |
) |
= |
Ft. |
Round, |
|
|
|
|
|
900 elbow |
|
|
|
|
|
7” - 10” |
9 Ft. |
x ( |
) |
= |
Ft. |
Round, |
|
|
|
|
|
450 elbow |
|
|
|
|
|
7” - 10” |
30 Ft. |
x ( |
) |
= |
Ft. |
Round |
|
|
|
|
|
wall cap |
|
|
|
|
|
with damper |
|
|
|
|
|
7” - 10” |
30 Ft. |
x ( |
) |
= |
Ft. |
Round, |
|
|
|
|
|
roof cap |
|
|
|
|
|
7” round to |
8 Ft. |
x ( |
) |
= |
Ft. |
3 1/ 4” x 10” |
|
|
|
|
|
rect. |
|
|
|
|
|
transition |
|
|
|
|
|
7” round to |
23 Ft. |
x ( |
) |
= |
Ft. |
3-1/ 4” x 10” |
|
|
|
|
|
rect. |
|
|
|
|
|
transition |
|
|
|
|
|
900 elbow |
|
|
|
|
|
|
Subtotal column 2 = |
Ft. |
|||
|
Subtotal column 1 = |
Ft. |
|||
|
Total ductwork |
|
= |
Ft. |
Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.
<![endif]>Installation – Ducting Calculation Sheet