Yaskawa GA500 Programming Manual

GA500
Industrial AC Microdrive
Programming
Catalog Code:
GA50Uxxxxxxxx
240 V Single-Phase Input: 1/6 to 5 HP 240 V Three-Phase Input: 1/6 to 30 HP 480 V Three-Phase Input: 1/2 to 40 HP
2 YASKAWA TOEPYAIGA5002A GA500 Programming

Table of Contents

1. Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.2 How to Read the Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Icons and Terms that Identify Parameters and Control Modes . . . . . . . . . . . . . . . . . . . . . .11
1.3 Parameter Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.4 A: Initialization Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A1: Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A2: User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.5 b: Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
b1: Operation Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
b2: DC Injection Braking and Short Circuit Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
b3: Speed Search. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
b4: Timer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
b5: PID control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
b6: Dwell Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
b8: Energy Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.6 C: Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C1: Accel & Decel Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C2: S-Curve Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C3: Slip Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
C4: Torque Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
C5: Automatic Speed Regulator (ASR: Automatic Speed Regulator) . . . . . . . . . . . . . . . 27
C6: Duty & Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1.7 d: Reference Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
d1: Frequency Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
d2: Reference Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
d3: Jump Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
d4: Frequency Ref Up/Down & Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
d6: Field Weakening /Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
d7: Offset Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
1.8 E: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
E1: V/f Pattern for Motor 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
E2: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
E3: V/f Pattern for Motor 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
E4: Motor 2 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
E5: PM Motor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
E9: Motor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.9 F: Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
F1: Fault Detection in PG Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
F6: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
YASKAWA TOEPYAIGA5002A GA500 Programming 3
F7: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
1.10 H: Terminal Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
H1: Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
H2: Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
H3: Analog Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
H4: Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
H5: Modbus Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
H6: Pulse Train Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
H7: Virtual MFIO selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1.11 L: Protection Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
L1: Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
L2: Power Loss Ride Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
L3: Stall Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
L4: Speed Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
L5: Fault Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
L6: Torque Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
L7: Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
L8: Drive Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
1.12 n: Special Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n1: Hunting Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n2: Auto Freq Regulator (AFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n3: High Slip/Overexcite Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n5: Feed Forward Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
n6: Online Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
n7: EZ Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
n8: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
nA: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
1.13 o: Keypad-Related Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
o1: Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
o2: Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
o3: Copy Keypad Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
o4: Maintenance Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
o5: Log Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1.14 q: DriveWorksEZ Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
q1-01 to qx-xx: Reserved for DriveWorksEZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
1.15 r: DWEZ Connection 1-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
r1-01 to r1-40: DriveWorksEZ Connection Parameters 1 to 20 (Upper / Lower) . . . . . . . . . . . 90
1.16 T: Motor Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T0: Tuning Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T1: Induction Motor Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T2: PM Motor Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
T3: ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
T4: EZ Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
1.17 U: Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
U1: Operation Status Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
U2: Fault Trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
U3: Fault History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
U4: Maintenance Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
U5: PID Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
U6: Operation Status Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
U8: DriveWorksEZ Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
1.18 Parameters that Change from the Default Settings with A1-02 [Control Method
Selection]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
4 YASKAWA TOEPYAIGA5002A GA500 Programming
1.19 Parameters that Change from the Default Settings with E3-01 [Motor 2 Control
Mode Selection] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
1.20 Parameters Changed by E1-03 [V/f Pattern Selection] . . . . . . . . . . . . . . . . . . . . . . . 113
1.21 Defaults by Drive Model and Duty Rating ND/HD. . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Single-Phase 200 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Three-Phase 200 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Three-Phase 400 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
1.22 Parameters Changed by PM Motor Code Selection. . . . . . . . . . . . . . . . . . . . . . . . . . 127
Yaskawa SMRA Series SPM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Yaskawa SMRD Series SPM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Yaskawa SSR1 Series IPM Motors (Derated Torque) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
2. Parameter Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
2.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
2.2 A: Initialization Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
A1: Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
A2: User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
2.3 b: Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
b1: Operation Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
b2: DC Injection Braking and Short Circuit Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
b3: Speed Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
b4: Timer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
b5: PID control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
b6: Dwell Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
b8: Energy Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
2.4 C: Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
C1: Accel & Decel Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
C2: S-Curve Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
C3: Slip Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
C4: Torque Compensation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
C5: Auto Speed Regulator (ASR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
C6: Duty & Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
2.5 d: References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
d1: Frequency Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
d2: Reference Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
d3: Jump Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
d4: Frequency Ref Up/Down & Hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
d6: Field Weakening /Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
d7: Offset Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
2.6 E: Motor Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
E1: V/f Pattern for Motor 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
E2: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
E3: V/f Pattern for Motor 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
E4: Motor 2 Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
E5: PM Motor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
E9: Motor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
2.7 F: Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
F1: Fault Detection in PG Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
F6, F7: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
2.8 H: Terminal Function Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
H1: Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
MFDI Setting Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
YASKAWA TOEPYAIGA5002A GA500 Programming 5
H2: Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
H2 MFDO Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
MFDO Setting Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
H3: Analog Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
H3: MFAI Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
Multi-Function Analog Input Terminal Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
H4: Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
H5: Memobus/Modbus Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
H6: Pulse Train Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
H7: Virtual MFIO Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
2.9 L: Protection Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
L1: Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
L2: Power Loss Ride Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
L3: Stall Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
L4: Speed Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
L5: Fault Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
L6: Torque Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
L7: Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
L8: Drive Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
2.10 n: Special Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
n1: Hunting Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
n2: Auto Freq Regulator (AFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
n3: High Slip Braking (HSB) and Overexcitation Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
n5: Feed Forward Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
n6: Online Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
n7: EZ Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
n8: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
nA: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425
2.11 o: Keypad-Related Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
o1: Keypad Display Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
o2: Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
o3: Copy Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
o4: Maintenance Mon Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
o5: Log Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
2.12 T: Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T0: Tuning Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T1: Induction Motor Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T2: PM Motor Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
T3: ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
T4: EZ Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
3. Startup Procedure and Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
3.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
3.2 Overview of Keypad Components and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
Indicator flashing statuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460
Keypad Mode and Menu Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461
Set up the Drive with General-Purpose Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462
Programming Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
Change Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
Verify and Set the Changed Parameters (Verify Menu). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
How to Switch between LOCAL and REMOTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
3.3 Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Digital character mapping table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
6 YASKAWA TOEPYAIGA5002A GA500 Programming
Show the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Check Modified Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Set and View Necessary Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
Change Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
Save a Backup of Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
Write Backed-up Parameters to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
Verify Keypad Parameters and Drive Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
Delete Parameters Backed Up to the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
3.4 Automatic Parameter Settings Optimized for Specific Applications (Application
Presets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471
3.5 Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
Auto-Tuning for Induction Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
Auto-Tuning for PM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
Auto-Tuning in EZ Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474
ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
Precautions before Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476
3.6 Test Run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
No-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Do a No-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Actual-Load Test Run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Do an Actual-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
3.7 Fine Tuning during Test Runs (Adjust the Control Function) . . . . . . . . . . . . . . . . . . . 481
V/f Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 481
Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
Open Loop Vector Control for PM Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483
Advanced Open Loop Vector Control Method for PM Motors . . . . . . . . . . . . . . . . . . . . . . . . . 484
EZ Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485
3.8 Test Run Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486
4. Mechanical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 489
4.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
4.2 Removing/Reattaching Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
Remove the Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
Reattach the Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
4.3 Remove and Reattach the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
Remove the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
Reattach the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
5. Electrical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495
5.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496
5.2 Standard Connection Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
5.3 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
Motor and Main Circuit Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
Main Circuit Terminal Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
5.4 Control Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
Control Circuit Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
Control Circuit Terminal Block Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
Control Circuit Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
Switches and Jumpers on the Terminal Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
5.5 Control I/O Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
Pulse Train Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
YASKAWA TOEPYAIGA5002A GA500 Programming 7
Set Sinking Mode/Sourcing Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511
Set the Input Signal for the MFAI Terminal A2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511
Set the Output Signal for the MFAO Terminal AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512
Switch ON Termination Resistor for MEMOBUS/Modbus Communications . . . . . . . . . . . . . 512
5.6 Connect the Drive to a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513
6. Preface and General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515
6.1 Receiving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
About Registered Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
6.2 Using the Product Safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Explanation of Signal Words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524
8 YASKAWA TOEPYAIGA5002A GA500 Programming
1

Parameter List

1.1 Section Safety ........................................................................................................... 10
1.2 How to Read the Parameter List ........................................................................... 11
1.3 Parameter Groups....................................................................................................12
1.4 A: Initialization Parameters....................................................................................13
1.5 b: Application ............................................................................................................ 15
1.6 C: Tuning .................................................................................................................... 25
1.7 d: Reference Settings..............................................................................................30
1.8 E: Motor Parameters ................................................................................................34
1.9 F: Options...................................................................................................................39
1.10 H: Terminal Functions .............................................................................................49
1.11 L: Protection Functions ..........................................................................................67
1.12 n: Special Adjustment.............................................................................................77
1.13 o: Keypad-Related Settings...................................................................................83
1.14 q: DriveWorksEZ Parameters ................................................................................89
1.15 r: DWEZ Connection 1-20 ....................................................................................... 90
1.16 T: Motor Tuning .........................................................................................................91
1.17 U: Monitors.................................................................................................................94
1.18 Parameters that Change from the Default Settings with A1-02 [Control
Method Selection] ..................................................................................................108
1.19 Parameters that Change from the Default Settings with E3-01 [Motor 2
Control Mode Selection].......................................................................................112
1.20 Parameters Changed by E1-03 [V/f Pattern Selection] .................................113
1.21 Defaults by Drive Model and Duty Rating ND/HD...........................................114
1.22 Parameters Changed by PM Motor Code Selection ......................................127
YASKAWA TOEPYAIGA5002A GA500 Programming 9

1.1 Section Safety

1.1 Section Safety
DANGER
Do not ignore the safety messages in this manual.
If you ignore the safety messages in this manual, it will cause serious injury or death. The manufacturer is not responsible for injuries or damage to equipment.
10 YASKAWA TOEPYAIGA5002A GA500 Programming

1.2 How to Read the Parameter List

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.2 How to Read the Parameter List

Icons and Terms that Identify Parameters and Control Modes

Icon Description
The parameter is available when operating the drive with V/f Control.
The parameter is available when operating the drive with Open Loop Vector Control.
The parameter is available when operating the drive with Open Loop Vector Control for PM.
The parameter is available when operating the drive with Advanced Open Loop Vector Control for PM.
The parameter is available when operating the drive with EZ Open Loop Vector Control.
Hex. Hexadecimal numbers that represent MEMOBUS addresses to change parameters over network communication.
RUN The parameter can be changed settings during run.
Expert The parameter that is available in Expert Mode only.
*1 Set A1-01 = 3 [Access Level Selection = Expert Level] to display and set Expert Mode parameters on the keypad.
Note:
Gray icons identify parameters that are not available in the specified control method.
*1
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 11

1.3 Parameter Groups

1.3 Parameter Groups
Represents the type of product parameters.
Parameter Name
A1 Initialization
A2 User Parameters
b1 Operation Mode Selection
b2 DC Injection Braking and Short Circuit Braking
b3 Speed Search
b4 Timer Function
b5 PID control
b6 Dwell Function
b8 Energy Saving
C1 Accel & Decel Time
C2 S-Curve Characteristics
C3 Slip Compensation
C4 Torque Compensation
C5
C6 Carrier Frequency
d1 Frequency Reference
d2 Reference Limits
d3 Jump Frequency
d4 Frequency Ref Up/Down & Hold
d6 Field Weakening /Forcing
d7 Offset Frequency
E1 V/f Pattern for Motor 1
E2 Motor Parameters
E3 V/f Pattern for Motor 2
E4 Motor 2 Parameters
E5 PM Motor Settings
E9 Motor Setting
F1 Fault Detection during PG Speed Control
F6 Communication Options
F7 Communication Options
H1 Digital Inputs
H2 Digital Outputs
H3 Analog Inputs
H4 Analog Outputs
H5 Modbus Communication
H6 Pulse Train Input/Output
Automatic Speed Regulator (ASR: Automatic Speed Regulator)
Parameter Name
H7 Virtual MFIO selection
L1 Motor Protection
L2 Power Loss Ride Through
L3 Stall Prevention
L4 Speed Detection
L5 Fault Restart
L6 Torque Detection
L7 Torque Limit
L8 Drive Protection
n1 Hunting Prevention
n2 Auto Freq Regulator (AFR)
n3 High Slip/Overexcite Braking
n5 Feed Forward Control
n6 Online Tuning
n7 EZ Drive
n8 PM Motor Control Tuning
nA PM Motor Control Tuning
o1 Keypad Display
o2 Keypad Operation
o3 Copy Keypad Function
o4 Maintenance Monitors
o5 Log Function
q DriveWorksEZ Parameters
r DWEZ Connection 1-20
T0 Tuning Mode Selection
T1 Induction Motor Auto-Tuning
T2 PM Motor Auto-Tuning
T3 ASR and Inertia Tuning
T4 EZ Tuning
U1 Operation Status Monitors
U2 Fault Trace
U3 Fault History
U4 Maintenance Monitors
U5 PID Monitors
U6 Operation Status Monitors
U8 DriveWorksEZ Monitors
12 YASKAWA TOEPYAIGA5002A GA500 Programming
1.4 A: Initialization Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

A1: Initialization

1.4 A: Initialization Parameters

No.
(Hex.)
A1-00
(0100)
RUN
A1-01
(0101)
RUN
A1-02
(0102)
A1-03
(0103)
A1-04
(0104)
A1-05
(0105)
A1-06
(0127)
Name Description
Language Selection
Sets the language for the LCD keypad.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not reset this parameter.
0 : English
1 : Japanese
2 : German
3 : French
4 : Italian
5 : Spanish
6 : Portuguese
7 : Chinese
8 : Czech
9 : Russian
10 : Turkish
11 : Polish
12 : Greek
Access Level Selection
Sets user access to parameters. The access level controls which parameters the keypad will display, and which parameters the user can set.
0 : Operation Only
1 : User Parameters
2 : Advanced Level
3 : Expert Level
Control Method Selection
Sets the control method for the drive application and the motor.
0 : V/f Control
2 : Open Loop Vector
5 : PM Open Loop Vector
6 : PM Advanced Open Loop Vector
8 : EZ Vector Control
Initialize Parameters
Sets parameters to default values.
0 : No Initialization
1110 : User Initialization
2220 : 2-Wire Initialization
3330 : 3-Wire Initialization
Password
Entry point for the password set in A1-05 [Password Setting]. The user can view the settings of parameters that are locked without entering the password. Enter the correct password in this parameter to change parameter settings.
Password Setting
Set the password to lock parameters and prevent changes to parameter settings. Enter the correct password in A1-04 [Password] to unlock parameters and accept changes.
Application Preset
Sets the drive to operate in selected application conditions.
0 : General-purpose
1 : Water Supply Pump 2
2 : Conveyor
3 : Exhaust Fan
4 : HVAC Fan
5 : Air Compressor
8 : Conveyor 2
Default
(Range)
0
(0 - 12)
2
(0 - 3)
2
(0, 2, 5, 6, 8)
0
(0 - 3330)
0000
(0000 - 9999)
0000
(0000 - 9999)
0
(0 - 5, 8)
Ref.
139
139
140
141
142
143
143
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 13
1.4 A: Initialization Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
A1-07
(0128)
Name Description
DriveWorksEZ Function Selection
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive firmware.
0 : Disabled
1 : Enabled
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.

A2: User Parameters

No.
(Hex.)
A2-01 to A2-32
(0106 - 0125)
A2-33
(0126)
Name Description
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and save the values to parameters A2-01 to A2-32. Use Setup Mode to show the saved parameters. You can immediately access these saved parameters.
User Parameter Auto Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to 32].
0 : Disabled: Manual Entry Required
1 : Enabled: Auto Save Recent Parms
Note:
When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.
Default
(Range)
0
(0 - 2)
0
(0, 1)
-
(0000 - 9999)
Default
(Range)
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Determined by A1-06
(0, 1)
Ref.
156
156
156
Ref.
157
157
14 YASKAWA TOEPYAIGA5002A GA500 Programming
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

b1: Operation Mode Selection

1.5 b: Application

No.
(Hex.)
b1-01
(0180)
b1-02
(0181)
b1-03
(0182)
b1-04
(0183)
b1-06
(0185)
b1-07
(0186)
b1-08
(0187)
b1-14
(01C3)
b1-15
(01C4)
Name Description
Frequency Reference Selection 1
Sets the input method for the frequency reference.
0 : Keypad
1 : Analog Input
2 : Memobus/Modbus Communications
3 : Option PCB
4 : Pulse Train Input
Run Command Selection 1
Sets the input method for the Run command.
0 : Keypad
1 : Digital Input
2 : Memobus/Modbus Communications
3 : Option PCB
Stopping Method Selection
Sets the method to stop the motor after removing a Run command or entering a Stop command.
Note:
When A1-02 = 5, 6, 8 [Control Method Selection = OLV/PM, AOLV/PM, EZOLV], the setting range is 0, 1, 3.
0 : Ramp to Stop
1 : Coast to Stop
2 : DC Injection Braking to Stop
3 : Coast to Stop with Timer
Reverse Operation Selection
Sets the reverse operation function. Disable reverse operation in fan or pump applications where reverse rotation is dangerous.
0 : Reverse Enabled
1 : Reverse Disabled
Digital Input Reading
Sets the number of times that the drive reads the sequence input command to prevent malfunction because of electrical interference.
0 : Single Scan
1 : Double Scan
LOCAL/REMOTE Run Selection
Sets drive response to an existing Run command when the drive receives a second Run command from a different location.
0 : Disregard Existing RUN Command
1 : Accept Existing RUN Command
Run Command Select in PRG Mode
Sets the conditions for the drive to accept a Run command entered from an external source when using the keypad to set parameters.
0 : Disregard RUN while Programming
1 : Accept RUN while Programming
2 : Allow Programming Only at Stop
Phase Order Selection
Sets the phase order for output terminals U/T1, V/T2, and W/T3. This parameter can align the Forward Run command from the drive and the forward direction of the motor without changing wiring.
0 : Standard
1 : Switch Phase Order
Frequency Reference Selection 2
Sets the input method for frequency reference 2.
0 : Keypad
1 : Analog Input
2 : Memobus/Modbus Communications
3 : Option PCB
4 : Pulse Train Input
Default
(Setting Range)
1
(0 - 4)
1
(0 - 3)
0
(0 - 3)
0
(0, 1)
1
(0, 1)
0
(0, 1)
0
(0 - 2)
0
(0, 1)
0
(0 - 4)
Ref.
158
160
160
163
163
164
164
Parameter List
165
1
165
YASKAWA TOEPYAIGA5002A GA500 Programming 15
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b1-16
(01C5)
Name Description
Run Command Selection 2
Sets the input method for Run Command 2 when the user switches the control circuit terminals ON/OFF to change the Run command source.
0 : Keypad
1 : Digital Input
2 : Memobus/Modbus Communications
3 : Option PCB
b1-17
(01C6)
Run Command at Power Up
Sets drive response when energizing a drive that has an external Run command. Set this parameter in applications where energizing or de-energizing the drive enables the Run command.
0 : Disregard Existing RUN Command
1 : Accept Existing RUN Command
b1-35
(1117)
Digital Input Deadband Time
Sets the deadband time for MFDIs.
Expert

b2: DC Injection Braking and Short Circuit Braking

No.
(Hex.)
b2-01
(0189)
b2-02
(018A)
b2-03
(018B)
b2-04
(018C)
b2-08
(0190)
b2-12
(01BA)
b2-13
(01BB)
b2-18
(0177)
Name Description
DC Injection/Zero SpeedThreshold
Sets the frequency to start DC Injection Braking or Short Circuit Braking.
Note:
This parameter is available when b1-03 = 0 [Stopping Method Selection = Ramp to Stop].
DC Injection Braking Current
DC Inject Braking Time at Start
DC Inject Braking Time at Stop
Magnetic Flux Compensation Value
Short Circuit Brake Time @ Start
Short Circuit Brake Time @ Stop
Short Circuit Braking Current
Sets the DC Injection Braking current as a percentage of the drive rated current.
Sets the DC Injection Braking Time at stop.
Sets the DC Injection Braking Time at stop.
Sets how much current the drive injects when DC Injection Braking at Start starts (Initial Excitation) as a percentage of E2-03 [Motor No-Load Current].
Sets the Short Circuit Braking time at start.
Sets the Short Circuit Braking time at stop.
Sets the Short Circuit Braking Current as a percentage of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
Default
(Setting Range)
0
(0 - 3)
0
(0, 1)
0.0 ms
(0.0 to 100.0 ms)
Default
(Range)
Determined by A1-02
(0.0 - 10.0 Hz)
50%
(0 - 75%)
0.00 s
(0.00 - 10.00 s)
Determined by A1-02
(0.00 - 10.00 s)
0%
(0 - 1000%)
0.00 s
(0.00 - 25.50 s)
A1-02 = 8: 0.00 s
Other than A1-02 = 8:
0.50 s
(0.00 - 25.50 s)
100.0%
(0.0 - 200.0%)
Ref.
167
167
168
Ref.
168
169
169
169
170
170
170
171

b3: Speed Search

No.
(Hex.)
b3-01
(0191)
b3-02
(0192)
16 YASKAWA TOEPYAIGA5002A GA500 Programming
Speed Search at Start Selection
SpeedSearch Deactivation Current
Name Description
Sets the Speed Search at Start function where the drive will perform Speed Search with each Run command.
0 : Disable
1 : Enabled
Sets the current level that stops Speed Search as a percentage of the drive rated output current. Usually it is not necessary to change this setting.
Default
(Range)
Determined by A1-02
(0, 1)
Determined by A1-02
(0 - 200%)
Ref.
174
175
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b3-03
(0193)
b3-04
(0194)
b3-05
(0195)
b3-06
(0196)
Expert
b3-07
(0197)
Expert
b3-08
(0198)
b3-09
(0199)
b3-10
(019A)
Expert
b3-14
(019E)
b3-17
(01F0)
Expert
b3-18
(01F1)
Expert
b3-19
(01F2)
b3-24
(01C0)
Name Description
Speed Search Deceleration Time
Sets the deceleration time during Speed Search operation. Set the length of time to decelerate from the maximum output frequency to the minimum output frequency.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this parameter takes effect only in Expert Mode.
V/f Gain during Speed Search
Sets the ratio used to reduce the V/f during searches to reduce the output current during speed searches.
Speed Search Delay Time
Sets the Speed Search delay time to activate a magnetic contactor installed between the drive and motor.
Speed Estimation Current Level 1
Speed Estimation Current Level 2
Speed Estimation ACR P Gain
Speed Estimation ACR I Time
Speed Estimation Detection Gain
Bi-directional Speed Search
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a coefficient of the motor rated current. Usually it is not necessary to change this setting.
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a coefficient of E2-03 [Motor No-Load Current] or E4-03 [Motor 2 Rated No-Load Current]. Usually it is not necessary to change this setting.
Sets the proportional gain for the automatic current regulator during Speed Estimation Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to change this setting.
Sets the integral time for the automatic current regulator during Speed Estimation Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to change this setting.
Sets the gain to correct estimated frequencies from Speed Estimation Speed Search.
Sets the direction of Speed Search to the direction of the frequency reference or in the motor rotation direction as detected by the drive.
0 : Disabled
1 : Enabled
Note:
When E9-01 = 0 [Motor Type Selection = Induction (IM)] and A1-02 = 0, 2, or 8
[Control Method Selection = V/f, OLV, or EZOLV], the default settings change when the setting of b3-24 [Speed Search Method Selection] changes.
b3-24 = 1 [Speed Estimation]: Refer to 108.b3-24 = 2 [Current Detection 2]: 0
When E9-01 = 1 or 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
and A1-02 = 0 or 8 [V/f, EZOLV], refer to 108.
When you set A1-02, b3-24, and E9-01, set b3-14.
Speed Est Retry Current Level
Speed Est Retry Detection Time
Speed Search Restart Attempts
Speed Search Method Selection
Sets the current level for the search retry function in Speed Estimation Speed Search as a percentage where drive rated current is a setting value of 100%.
Sets the length of time that the drive will wait to retry Speed Estimation Speed Search when too much current flow stopped the Speed Search.
Sets the number of times to restart Speed Search if Speed Search does not complete.
Sets the Speed Search method when you start the motor or when you restore power after a momentary power loss.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], the default setting changes
when the setting for E9-01 [Motor Type Selection] changes.
E9-01 = 0 [Induction (IM)]: 2E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]: 1
When you set b3-24, it will trigger the drive to initialize b3-14 [Bi-directional Speed
Search]. After you set b3-24, set b3-14.
1 : Speed Estimation
2 : Current Detection 2
Default
(Range)
2.0 s
(0.1 - 10.0 s)
Determined by o2-04
(10 - 100)
0.2 s
(0.0 - 100.0 s)
Determined by o2-04
(0.0 - 2.0)
1.0
(0.0 - 3.0)
Determined by A1-02 and
o2-04
(0.00 - 6.00)
Determined by A1-02
when A1-02 ≠ 5
20.0 when A1-02 = 5
(0.0 - 1000.0 ms)
1.05
(1.00 - 1.20)
Determined by A1-02 and
b3-24
(0, 1)
150%
(0 - 200%)
0.10 s
(0.00 - 1.00 s)
3 times
(0 - 10 times)
2
(1, 2)
Ref.
175
175
175
175
176
176
176
176
176
177
177
Parameter List
177
1
177
YASKAWA TOEPYAIGA5002A GA500 Programming 17
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b3-25
(01C8)
Expert
b3-26
(01C7)
Expert
b3-29
(077C)
Expert
b3-31
(0BC0)
Expert
b3-32
(0BC1)
Expert
b3-33
(0B3F)
Expert
b3-54
(3123)
b3-55
(3124)
Expert
b3-56
(3126)
b3-61
(1B96)
Expert
Name Description
Speed Search Wait Time
Sets the length of time the drive will wait to start the Speed Search Retry function.
Direction Determination Level
Speed Search Back-EMF Threshold
Spd Search Current Reference Lvl
Spd Search Current Complete Lvl
Speed Search during Uv Selection
Sets the level to find the motor rotation direction. Increase the value if the drive cannot find the direction.
Sets the induced voltage for motors that use Speed Search. The drive will start Speed Search when the motor induced voltage level is the same as the setting value. Usually it is not necessary to change this setting.
Sets the current level that decreases the output current during Current Detection Speed Search.
Sets the current level that completes Speed Search.
Sets the function that starts Speed Search at start-up if the drive detects a Uv [Undervoltage] when it receives a Run command.
0 : Disabled
1 : Enabled
Search Time
Sets the length of time that the drive will run Speed Search.
Current Increment Time
Sets the length of time that the drive will increase the current from zero current to the setting value of b3-06 [Speed Estimation Current Level 1].
InverseRotationSearch WaitTime
Initial Pole Detection Response Gain
Sets the wait time until the drive starts inverse rotation search after it completes forward search when you do inverse rotation search during Current Detection Speed Search.
Sets the responsiveness for initial motor magnetic pole calculation when A1-02 = 6 [Control Method Selection = AOLV/PM]. Set b3-61 > 0.0 for an ordinary IPM motor.
It is automatically set if High Frequency Injection Tuning is used.
Note:
Set n8-35 = 1 [Initial Pole Calculation Method = High Frequency Injection] to
enable this parameter.
Set n8-41 [HFI P Gain] to adjust the responsiveness for initial motor magnetic pole
calculation when A1-02 = 5 [OLV/PM].
Default
(Range)
0.5 s
(0.0 - 30.0 s)
1000
(40 to 60000)
10%
(0 - 10%)
1.50
(1.50 - 3.50)
1.20
(0.00 - 1.49)
1
(0, 1)
400 ms
(10 - 2000 ms)
10 ms
(10 - 2000 ms)
Determined by o2-04
(0.1 - 5.0 s)
5.0
(-20.0 - +20.0)
Ref.
178
178
178
178
178
179
179
179
179
179

b4: Timer Function

No.
(Hex.)
b4-01
(01A3)
b4-02
(01A4)
b4-03
(0B30)
Expert
b4-04
(0B31)
Name Description
Timer Function ON­Delay Time
Timer Function OFF­Delay Time
Terminal M1-M2 ON­Delay Time
Terminal M1-M2 OFF­Delay Time
Sets the ON-delay time for the timer input.
Sets the OFF-delay time for the timer input.
Sets the delay time until the contact is turned ON after the function set with H2-01 turns ON.
Sets the delay time to deactivate the contact after the function set in H2-01 deactivates.
Expert
b4-05
(0B32)
Terminal M3-M4 ON­Delay Time
Sets the delay time to activate the contact after the function set in H2-02 activates.
Expert
b4-06
(0B33)
Terminal M3-M4 OFF­Delay Time
Sets the delay time to deactivate the contact after the function set in H2-02 deactivates.
Expert
18 YASKAWA TOEPYAIGA5002A GA500 Programming
Default
(Range)
0.0 s
(0.0 - 3000.0 s)
0.0 s
(0.0 - 3000.0 s)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
Ref.
180
180
181
181
181
181
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b4-07
(0B34)
Name Description
Terminal P2 ON-Delay Time
Expert
b4-08
(0B35)
Terminal P2 OFF-Delay Time
Expert

b5: PID control

No.
(Hex.)
b5-01
(01A5)
b5-02
(01A6)
RUN
b5-03
(01A7)
RUN
b5-04
(01A8)
RUN
b5-05
(01A9)
RUN
b5-06
(01AA)
RUN
b5-07
(01AB)
RUN
b5-08
(01AC)
RUN
Expert
Name Description
PID Mode Setting
Proportional Gain (P)
Integral Time (I)
Integral Limit
Derivative Time (D)
PID Output Limit
PID Offset Adjustment
PID Primary Delay Time Constant
Sets the delay time until the contact is turned ON after the function set with H2-03 turns ON.
Sets the delay time to deactivate the contact after the function set in H2-03 deactivates.
Sets the type of PID control.
0 : Disabled
1 : Standard
2 : Standard (D on feedback)
3 : Fref + PID Trim
4 : Fref + PID Trim (D on feedback)
5 : Same as 7series & prior, b5-01=1
6 : Same as 7series & prior, b5-01=2
7 : Same as 7series & prior, b5-01=3
8 : Same as 7series & prior, b5-01=4
Note:
Use settings 5 to 8 when the drive is a replacement for a previous generation drive.
Sets the proportional gain (P) that is applied to PID input.
Sets the integral time (I) that is applied to PID input.
Sets the upper limit for integral control (I) as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the derivative time (D) for PID control. This parameter adjusts system responsiveness.
Sets the maximum possible output from the PID controller as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the offset for the PID control output as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the primary delay time constant for the PID control output. Usually it is not necessary to change this setting.
Default
(Range)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
Default
(Range)
0
(0 - 8)
1.00
(0.00 - 25.00)
1.0 s
(0.0 - 360.0 s)
100.0%
(0.0 - 100.0%)
0.00 s
(0.00 - 10.00 s)
100.0%
(0.0 - 100.0%)
0.0%
(-100.0 - +100.0%)
0.00 s
(0.00 - 10.00 s)
Ref.
181
181
Ref.
187
188
188
188
189
189
189
189
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 19
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-09
(01AD)
b5-10
(01AE)
RUN
b5-11
(01AF)
b5-12
(01B0)
b5-13
(01B1)
b5-14
(01B2)
b5-15
(01B3)
b5-16
(01B4)
b5-17
(01B5)
RUN
b5-18
(01DC)
b5-19
(01DD)
RUN
b5-20
(01E2)
b5-34
(019F)
RUN
Name Description
PID Output Level Selection
Sets the polarity of the PID output.
0 : Normal Output (Direct Acting)
1 : Reverse Output (Reverse Acting)
PID Output Gain Setting
Sets the amount of gain to apply to the PID output.
PID Output Reverse Selection
Sets the function that enables and disables reverse motor rotation for negative PID control output.
0 : Lower Limit is Zero
1 : Negative Output Accepted
Feedback Loss Detection Select
Sets the drive response to PID feedback loss/excess. Sets drive operation after the drive detects PID feedback loss/excess.
0 : Digital Out Only, Always Detect
1 : Alarm + Digital Out, Always Det
2 : Fault + Digital Out, Always Det
3 : Digital Out Only, @ PID Enable
4 : Alarm + Digital Out, @PID Enable
5 : Fault + Digital Out, @PID Enable
PID Feedback Loss Detection Lvl
Sets the level that triggers PID Feedback Loss [FbL] detection as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Feedback Loss Detection Time
PID Sleep Function Start Level
Sets the length of time that PID Feedback must be less than b5-13 [PID Feedback Loss Detection Lvl] to detect PID Feedback Loss [FbL].
Sets the output level that triggers the PID Sleep function.
PID Sleep Delay Time
Sets a delay time to start or stop the PID Sleep function.
PID Accel/Decel Time
Raises or lowers the PID setpoint using the acceleration and deceleration times set to the drive. This is a soft-starter for the PID setpoint.
b5-19 PID Setpoint Selection
Sets the function that enables and disables b5-19 [PID Setpoint Value].
0 : Disabled
1 : Enabled
PID Setpoint Value
Sets the PID setpoint when b5-18 = 1 [b5-19 PID Setpoint Selection = Enabled].
PID Unit Selection
Sets the number of digits to set and show the PID setpoint.
0 : 0.01Hz units
1 : 0.01% units
2 : rev/min
3 : User Units
PID Output Lower Limit Level
Sets the output lower limit for the PID control as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
0
(0, 1)
1.00
(0.00 - 25.00)
0
(0, 1)
0
(0 - 5)
0%
(0 - 100%)
1.0 s
(0.0 - 25.5 s)
Determined by A1-02
(0.0 - 590.0)
0.0 s
(0.0 - 25.5 s)
0.0 s
(0.0 - 6000.0 s)
0
(0, 1)
0.00%
(0.00 - 100.00%)
1
(0 - 3)
0.0%
(-100.0 - +100.0%)
Ref.
189
189
190
190
191
191
191
191
191
192
192
192
192
20 YASKAWA TOEPYAIGA5002A GA500 Programming
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-35
(01A0)
RUN
b5-36
(01A1)
b5-37
(01A2)
b5-38
(01FE)
b5-39
(01FF)
b5-40
(017F)
b5-47
(017D)
b5-53
(0B8F)
RUN
b5-55
(0BE1)
b5-56
(0BE2)
b5-57
(11DD)
b5-58 to b5-60:
(1182 - 1184)
RUN
b5-61
(119A)
Name Description
PID Input Limit Level
Sets the output upper limit for the PID control as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID High Feedback Detection Lvl
Sets the level that triggers Excessive PID Feedback [FbH] as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID High Feedback Detection Time
PID User Unit Display Scaling
PID User Unit Display Digits
Sets the length of time that the PID feedback signal must be more than the level set in b5- 36 [PID Feedback High Detection Lvl] to cause Excessive PID Feedback [FbH].
Sets the value that the drive sets or shows as the PID setpoint when at the maximum output frequency.
Sets the number of digits to set and show the PID setpoint.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
Frequency Reference Monitor @PID
Sets the contents for monitor U1-01 [Frequency Reference] in PID control.
0 : U1-01 Includes PID Output
1 : U1-01 Excludes PID Output
PID Trim Mode Output Reverse Sel
Sets reverse motor rotation when the PID control output is negative.
0 : Lower Limit is Zero
1 : Negative Output Accepted
PID Integrator Ramp Limit
PID Feedback Monitor Selection
PID Feedback Monitor Gain
PID Feedback Monitor Bias
Sets the responsiveness of PID control when the PID feedback changes quickly.
Sets the monitor (Ux-xx) used as the PID Feedback. Set the x-xx part of the Ux-xx [Monitor].
Sets the gain for the monitor set in b5-55 [PID Feedback Monitor Selection].
Sets the bias for the monitor specified in b5-55 [PID Feedback Monitor Selection].
PID Setpoints 2 to 4
Sets the PID setpoint when H1-xx = 3E or 3F [MFDI Function Selection = PID Setpoint Selection 1/2]. This value is a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Trim Mode Lower Limit Sel
Sets the function that adjusts the PID output in relation to the frequency reference.
0 : Disabled
1 : Enabled
Default
(Range)
1000.0%
(0.0 - 1000.0%)
100%
(0 - 100%)
1.0 s
(0.0 - 25.5 s)
Determined by b5-20
(1 - 60000)
Determined by b5-20
(0 - 3)
0
(0, 1)
1
(0, 1)
0.0 Hz
(0.0 - 10.0 Hz)
000
(000 - 999)
1.00
(0.00 - 10.00)
0.00
(-10.00 - +10.00)
0.00%
(0.00 - 100.00%)
0
(0, 1)
Ref.
193
193
193
193
193
194
194
194
194
195
195
195
Parameter List
1
195
YASKAWA TOEPYAIGA5002A GA500 Programming 21
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-62
(119B)
b5-63
(119C)
b5-64
(119D)
b5-65
(119F)
b5-66
(11DE)
b5-67
(11DF)
b5-89
(0B89)
RUN
b5-90
(0B90)
b5-91
(0B91)
RUN
b5-92
(0B92)
RUN
b5-93
(0B93)
RUN
b5-94
(0B94)
RUN
b5-95
(0B95)
b5-96
(0B96)
RUN
Name Description
PID Trim Mode Lower Limit Value
Sets the PID Trim Mode Lower Limit Value as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Differential FB Monitor Sel
PID Differential FB Monitor Gain
PID Differential FB Monitor Bias
PID Feedback Monitor Level
Selects the monitor (Ux-xx) used as the PID Differential Feedback. Set the x-xx part of the Ux-xx [Monitor].
Sets the gain for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
Sets the bias for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
Sets the signal level for the monitor specified in b5-55 [PID Feedback Monitor Selection].
0 : Absolute
1 : Bi-directional (+/-)
PID Differential FB Monitor Lvl
Sets the signal level for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
0 : Absolute
1 : Bi-directional (+/-)
Sleep Method Selection
Sets sleep and wake up operation when using PID.
0 : Standard
1 : EZ Sleep/Wake-up
EZ Sleep Unit
Sets the measurement units for b5-91 [EZ Sleep Minimum Speed] and b5-92 [EZ Sleep Level].
0 : 0.1Hz units
1 : rev/min
EZ Sleep Minimum Speed
Sets the minimum speed for the EZ Sleep/Wakeup function. This parameter uses the largest value from b5-91, b5-34 [PID Output Lower Limit Level], and d2-02 [Frequency Reference Lower Limit].
EZ Sleep Level
Sets the value that the output frequency or motor speed must be less than for longer than b5-93 [EZ Sleep Time] to enter Sleep Mode.
EZ Sleep Time
Sets the length of time that the output frequency or motor speed must be less than b5-92 [EZ Sleep Level] to enter Sleep Mode.
EZ Sleep Wake-up Level
Sets the level at which the drive resumes operation when exiting Sleep Mode.
EZ Sleep Wake-up Mode
Sets the wake-up mode to use when exiting Sleep Mode.
0 : Absolute
1 : Setpoint Delta
EZ Sleep Wake-up Time
Sets the EZ Wake-up time.
Default
(Range)
0.00%
(0.00 - 100.00%)
000
(000 - 999)
1.00
(0.00 - 10.00)
0.00
(-10.00 - +10.00)
0
(0, 1)
0
(0, 1)
0
(0, 1)
0
(0, 1)
-1
(r/min))
-1
(r/min))
-1
-1
(r/min)
(r/min)
0.0 Hz or 0 min
(0.0 to 590.0 Hz or 0 to
35400 min
0.0 Hz or 0 min
(0.0 to 590.0 Hz or 0 to
35400 min
5.0 s
(0.0 - 1000.0 s)
0.00%
(0.00 - 600.00%)
0
(0, 1)
1.0 s
(0.0 - 1000.0 s)
Ref.
196
196
196
196
196
196
196
197
197
197
197
197
198
198
22 YASKAWA TOEPYAIGA5002A GA500 Programming

b6: Dwell Function

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.5 b: Application
No.
(Hex.)
b6-01
Name Description
Dwell Reference at Start
(01B6)
b6-02
Dwell Time at Start
(01B7)
b6-03
Dwell Reference at Stop
(01B8)
b6-04
Dwell Time at Stop
(01B9)

b8: Energy Saving

No.
(Hex.)
b8-01
(01CC)
b8-02
(01CD)
RUN
Expert
b8-03
(01CE)
RUN
Expert
b8-04
(01CF)
Expert
b8-05
(01D0)
Expert
b8-06
(01D1)
Expert
b8-16
(01F8)
Expert
b8-17
(01F9)
Expert
b8-18
(01FA)
Expert
b8-19
(0B40)
Expert
b8-20
(0B41)
Expert
Name Description
Energy Saving Control Selection
Energy Saving Gain
Energy Saving Filter Time
Energy Saving Coefficient Value
Power Detection Filter Time
Search Operation Voltage Limit
PM E-Save Coefficient Ki
PM E-Save Coefficient Kt
E-Save d-axis Current FilterTime
E-Save Search Frequency
E-Save Search Width
Sets the output frequency that the drive will hold momentarily when the motor starts.
Sets the length of time that the drive will hold the output frequency when the motor starts.
Sets the output frequency that the drive will hold momentarily when ramping to stop the motor.
Sets the length of time for the drive to hold the output frequency when ramping to stop the motor.
Sets the Energy-saving control function.
0 : Disabled
1 : Enabled
2 : Automatic Optimization
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], you can only select setting 2 in Expert Mode.
Sets the gain for Energy-saving control.
Sets the responsiveness for Energy-saving control.
Sets the Energy-saving control coefficient to maintain maximum motor efficiency. The default setting is for Yaskawa motors.
Sets the time constant to measure output power.
Sets the voltage limit for Search Operation as a percentage of the motor rated voltage.
Sets torque linearity. This parameter uses the Ki value from the motor nameplate. Usually it is not necessary to change this setting.
Sets torque linearity. This parameter uses the Kt value from the motor nameplate. Usually it is not necessary to change this setting.
Sets the d-axis current reference filter time constant.
Sets the frequency of Energy-saving control search operations. Usually it is not necessary to change this setting.
Sets the amplitude of Energy-saving control search operations.
Default
(Range)
0.0
(Determined by A1-02)
0.0 s
(0.0 - 10.0 s)
0.0
(Determined by A1-02)
0.0 s
(0.0 - 10.0 s)
Default
(Range)
0
(0 - 2)
Determined by A1-02
(0.0 - 10.0)
Determined by A1-02
C6-01 and o2-04
(0.00 - 10.00 s)
Determined by C6-01,
E2-11, and o2-04
(0.00 - 655.00)
20 ms
(0 - 2000 ms)
0%
(0 - 100%)
1.00
(0.00 - 3.00)
1.00
(0.00 - 3.00)
0.100 s
(0.000 - 5.000 s)
Determined by A1-02
(10 - 300 Hz)
1.0 degrees
(0.1 - 5.0 degrees)
Ref.
198
199
199
199
Ref.
199
200
200
200
200
200
201
Parameter List
201
1
201
201
201
YASKAWA TOEPYAIGA5002A GA500 Programming 23
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b8-21
(0B42)
Expert
b8-22
(0B43)
Expert
b8-23
(0B44)
Expert
b8-24
(0B45)
Expert
b8-25
(0B46)
Expert
b8-26
(0B47)
Expert
b8-28
(0B8B)
Expert
b8-29
(0B8C)
Name Description
PM E-Save Search Gain
Sets the gain of Energy-saving control search operations.
PM E-Save Search LPF Cutoff Freq
Sets the frequency of the filter used to extract the high-efficiency phase from search operations. Usually it is not necessary to change this setting.
PM E-Save Search Limit
Sets the search operations output limit. Usually it is not necessary to change this setting.
PM E-Save High Freq ACR Gain
PM E-Save Search Start Level
PM E-Save Power Setpoint
Over Excitation Action Selection
Sets the gain for high-frequency current control.
Sets the start level for search operations.
Sets a value to increase torque accuracy.
Sets the function for excitation operation.
0 : Disabled
1 : Enabled
Energy Saving Priority Selection
Sets the priority of drive response between changes to the load or Energy-saving control. Enable this to prioritize energy-saving control. Disable this to prioritize tracking related to fast load changes, and prevent motor stall.
0 : Priority: Drive Response
1 : Priority: Energy Savings
Default
(Range)
0.3Hz
(0.1 - 20.0 Hz)
10.0 Hz
(1.0 - 30.0 Hz)
15.0 degrees
(0.0 - 30.0 degrees)
200.0 Hz
(100.0 - 1000.0 Hz)
10.0%
(0.0 - 100.0%)
0.0%
(-10.0 - +10.0%)
0
(0, 1)
0
(0, 1)
Ref.
202
202
202
202
202
202
203
203
24 YASKAWA TOEPYAIGA5002A GA500 Programming
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

C1: Accel & Decel Time

1.6 C: Tuning

No.
(Hex.)
C1-01
(0200)
RUN
C1-02
(0201)
RUN
C1-03
(0202)
RUN
C1-04
(0203)
RUN
C1-05
(0204)
RUN
C1-06
(0205)
RUN
C1-07
(0206)
RUN
C1-08
(0207)
RUN
C1-09
(0208)
RUN
C1-10
(0209)
C1-11
(020A)
C1-14
(0264)
RUN
Name Description
Acceleration Time 1
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 1
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 2
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 2
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 3
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 3
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 4
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 4
Sets the length of time to decelerate from maximum output frequency to zero.
Fast Stop Time
Sets the length of time that the drive will decelerate to zero for a Fast Stop.
Note:
Decelerating too quickly can cause an ov [Overvoltage] fault that shuts off the drive
while the motor to coasts to a stop. Set a Fast Stop time in C1-09 that prevents motor coasting and makes sure that the motor stops quickly and safely.
When L2-29 = 0 [Kinetic Energy Backup Method = Single Drive KEB Ride-Thru 1]
and you do KEB Auto-Tuning, the drive will automatically set C1-09. If you must not change the Fast Stop time, do not do KEB Tuning.
Accel/Decel Time Setting Units
Sets the setting units for C1-01 to C1-08 [Accel/Decel Times 1 to 4], C1-09 [Fast Stop
Time], L2-06 [Kinetic Energy Backup Decel Time], and L2-07 [Kinetic Energy Backup Accel Time].
0 : 0.01 s (0.00 to 600.00 s)
1 : 0.1 s (0.0 to 6000.0 s)
Accel/Decel Time Switching Frequency
Accel/Decel Rate Frequency
Sets the frequency at which the drive will automatically change acceleration and deceleration times.
Sets the base frequency used to calculate acceleration and deceleration rates.
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
1
(0, 1)
Determined by A1-02
(0.0 - 590.0 Hz)
0.0 Hz
(0.0 - 590.0 Hz)
Ref.
206
206
206
206
206
206
207
207
207
207
208
208
Parameter List
1

C2: S-Curve Characteristics

No.
(Hex.)
C2-01
(020B)
C2-02
(020C)
Name Description
S-Curve Time @ Start of Accel
S-Curve Time @ End of Accel
Sets the S-curve acceleration time at start.
Sets the S-curve acceleration time at completion.
YASKAWA TOEPYAIGA5002A GA500 Programming 25
Default
(Range)
Determined by A1-02
(0.00 - 10.00 s)
0.20 s
(0.00 - 10.00 s)
Ref.
210
210
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C2-03
(020D)
C2-04
(020E)
Name Description
S-Curve Time @ Start of Decel
S-Curve Time @ End of Decel
Sets the S-curve deceleration time at start.
Sets the S-curve deceleration time at completion.

C3: Slip Compensation

No.
(Hex.)
C3-01
(020F)
RUN
C3-02
(0210)
RUN
C3-03
(0211)
C3-04
(0212)
C3-05
(0213)
C3-16
(0261)
Expert
C3-17
(0262)
Expert
C3-18
(0263)
Expert
C3-21
(033E)
RUN
C3-22
(0241)
RUN
C3-23
(0242)
Name Description
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
E2-01 [Motor Rated Current (FLA)]
E2-02 [Motor Rated Slip]
E2-03 [Motor No-Load Current]
Slip Compensation Delay Time
Sets the slip compensation delay time when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor rated slip.
Slip Compensation at Regen
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
Output Voltage Limit Selection
Sets the automatic reduction of motor magnetic flux when the output voltage is saturated.
0 : Disabled
1 : Enabled
Vout Modulation Limit Start Lvl
Vout Modulation Limit Max Level
Output Voltage Limit Level
Motor 2 Slip Compensation Gain
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the modulation factor used with C3-18 [Output Voltage Limit Level] for the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
E4-01 [Motor 2 Rated Current]
E4-02 [Motor 2 Rated Slip]
E4-03 [Motor 2 Rated No-Load Current]
Motor 2 Slip Comp Delay Time
Motor 2 Slip Compensation Limit
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
Sets the upper limit for the slip compensation function as a percentage of the motor 2 rated slip.
Default
(Range)
0.20 s
(0.00 - 10.00 s)
0.00 s
(0.00 - 10.00 s)
Default
(Range)
Determined by A1-02
(0.0 - 2.5)
Determined by A1-02
(0 - 10000 ms)
200%
(0 - 250%)
0
(0 - 2)
0
(0, 1)
90.0%
(70.0 - 90.0%)
100.0%
(85.0 - 100.0%)
90.0%
(50.0 - 100.0%)
Determined by E3-01
(0.0 - 2.5)
Determined by E3-01
(0 - 10000 ms)
200%
(0 - 250%)
Ref.
210
210
Ref.
211
211
211
212
212
212
213
213
213
213
213
26 YASKAWA TOEPYAIGA5002A GA500 Programming
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C3-24
(0243)
Name Description
Motor 2 Slip Comp during Regen
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
C3-29
(1B5D)
Expert
Slip Compensation Gain @ Low Spd
Sets the gain for the slip compensation function in the low speed range. Usually it is not necessary to change this setting.

C4: Torque Compensation

No.
(Hex.)
C4-01
(0215)
RUN
C4-02
(0216)
RUN
C4-03
(0217)
C4-04
(0218)
C4-05
(0219)
C4-06
(021A)
C4-07
(0341)
RUN
C4-23
(1583)
RUN
Expert
Name Description
Torque Compensation Gain
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when operating multiple motors.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], you cannot change this parameter during drive run.
Torque Compensation Delay Time
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Note:
If A1-02 = 8 [Control Method Selection = EZOLV], you cannot change the setting while the drive is running.
Torque Compensation @ FWD Start
Torque Compensation @ REV Start
Torque Compensation Time
Motor 2 Torque Comp Delay Time
Motor 2 Torque Compensation Gain
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
Sets the starting torque constant to use with C4-03 and C4-04 [Torque Compensation @ FWD/REV Start].
Sets the value if ov [Overvoltage] occurs with sudden changes in the load, at the end of acceleration, or at the start of deceleration.
Sets the gain for motor 2 torque compensation function when using the Motor Switch function.
Current Control Gain
Current control gain. Usually it is not necessary to change this parameter.
Default
(Range)
0
(0 - 2)
0.0
(0.0 - 2.5)
Default
(Range)
Determined by A1-02
(0.00 - 2.50)
Determined by A1-02
(0 - 60000 ms)
0.0%
(0.0 - 200.0%)
0.0%
(-200.0 - 0.0%)
10 ms
(0 - 200 ms)
150 ms
(0 - 10000 ms)
1.00
(0.00 - 2.50)
1.00
(0.50 - 2.50)
Ref.
214
214
Ref.
215
215
215
215
216
216
216
216

C5: Automatic Speed Regulator (ASR: Automatic Speed Regulator)

No.
(Hex.)
C5-01
(021B)
RUN
C5-02
(021C)
RUN
Name Description
ASR Proportional Gain 1
Sets the gain to adjust ASR response.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Integral Time 1
Sets the ASR integral time.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Determined by A1-02
(0.000 - 60.000 s)
Ref.
219
219
YASKAWA TOEPYAIGA5002A GA500 Programming 27
Parameter List
1
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C5-03
(021D)
RUN
C5-04
(021E)
RUN
C5-05
(021F)
C5-06
(0220)
C5-07
(0221)
C5-08
(0222)
C5-12
(0386)
C5-29
(0B18)
Expert
C5-39
(030D)
Name Description
ASR Proportional Gain 2
Sets the gain to adjust ASR response.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Integral Time 2
Sets the ASR integral time.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Limit
Sets the ASR output limit where E1-04 [Maximum Output Frequency] is 100%.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Delay Time
Sets the filter time constant of the torque reference output from the speed loop. Usually it is not necessary to change this setting.
ASR Gain Switchover Frequency
Sets the frequency where the drive will switch between these parameters:
C5-01 and C5-03 [ASR Proportional Gain 1/2] C5-02 and C5-04 [ASR Integral Time 1/2]
ASR Integral Limit
Set the upper limit of the ASR integral amount as a percentage of the rated load.
Integral Operation @ Accel/Decel
Sets ASR integral operation during acceleration and deceleration.
0 : No
1 : Yes
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Speed Control Response
Sets the level of speed control responsiveness. Usually it is not necessary to change this setting.
0 : Standard
1 : High Performance 1
ASR Primary Delay Time Const 2
Sets the filter time constant used when the torque reference is output from ASR. Usually it is not necessary to change this parameter.
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Determined by A1-02
(0.000 - 60.000 s)
5.0%
(0.0 - 20.0%)
Determined by A1-02
(0.000 - 0.500 s)
Determined by A1-02
(Determined by A1-02)
400%
(0 - 400%)
0
(0, 1)
1
(0, 1)
0.000 s
(0.000 - 0.500 s)
Ref.
219
220
220
220
220
220
221
221
221
28 YASKAWA TOEPYAIGA5002A GA500 Programming

C6: Duty & Carrier Frequency

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.6 C: Tuning
No.
(Hex.)
C6-01
(0223)
C6-02
(0224)
C6-03
(0225)
C6-04
(0226)
C6-05
(0227)
C6-09
(022B)
Name Description
Normal / Heavy Duty Selection
Sets the drive duty rating.
0 : Heavy Duty Rating
1 : Normal Duty Rating
Carrier Frequency Selection
Sets the carrier frequency for the transistors in the drive.
1 : 2.0 kHz
2 : 5.0 kHz (4.0 kHz for AOLV/PM)
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM4 (Audible Sound 1)
8 : Swing PWM4 (Audible Sound 2)
9 : Swing PWM4 (Audible Sound 3)
A : Swing PWM4 (Audible Sound 4)
B : Leakage Current Rejection PWM
F : User Defined (C6-03 to C6-05)
Note:
The setting range changes when the A1-02 [Control Method Selection] value
changes:
5, 8 [OLV/PM, EZOLV]: You cannot set to 7 to A.When 6 [AOLV/PM]: 2 [5.0 kHz (AOLV/PM: 4.0 kHz)] is available.
The carrier frequency for Swing PWM 1 is equivalent to 2.0 kHz. Swing PWM
applies a special PWM pattern to decrease the audible noise.
Carrier Frequency Upper Limit
Carrier Frequency Lower Limit
Carrier Freq Proportional Gain
Carrier Freq at Rotational Tune
Sets the upper limit of the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the lower limit of the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the proportional gain for the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the Auto-Tuning carrier frequency. Usually it is not necessary to change this setting.
0 : 5 kHz
1 : Use C6-03
Default
(Range)
1
(0, 1)
Determined by A1-02,
C6-01, and o2-04
(Determined by A1-02)
Determined by C6-02
(1.0 - 15.0 kHz)
Determined by C6-02
(1.0 - 15.0 kHz)
Determined by C6-02
(0 - 99)
0
(0, 1)
Ref.
221
222
223
224
224
224
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 29

1.7 d: Reference Settings

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.7 d: Reference Settings

d1: Frequency Reference

No.
(Hex.)
d1-01
(0280)
RUN
d1-02
(0281)
RUN
d1-03
(0282)
RUN
d1-04
(0283)
RUN
d1-05
(0284)
RUN
d1-06
(0285)
RUN
d1-07
(0286)
RUN
d1-08
(0287)
RUN
d1-09
(0288)
RUN
d1-10
(028B)
RUN
d1-11
(028C)
RUN
Name Description
Reference 1
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 2
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 3
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 4
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 5
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 6
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 7
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 8
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 9
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 10
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 11
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
Ref.
228
229
229
229
229
229
230
230
230
230
231
30 YASKAWA TOEPYAIGA5002A GA500 Programming
1.7 d: Reference Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
d1-12
(028D)
RUN
d1-13
(028E)
RUN
d1-14
(028F)
RUN
d1-15
(0290)
RUN
d1-16
(0291)
RUN
d1-17
(0292)
RUN
Name Description
Reference 12
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 13
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 14
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 15
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 16
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Jog Reference
Sets the Jog frequency reference in the units from o1-03 [Frequency Display Unit Selection]. Set H1-xx = 6 [MFDI Function Select = Jog Reference Selection] to use the Jog frequency reference.
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
6.00 Hz
(0.00 - 590.00 Hz)
Ref.
231
231
231
231
232
232

d2: Reference Limits

No.
(Hex.)
d2-01
(0289)
d2-02
(028A)
d2-03
(0293)
Name Description
Frequency Reference Upper Limit
Frequency Reference Lower Limit
Analog Frequency Ref Lower Limit
Sets maximum limit for all frequency references. The maximum output frequency is 100%.
Sets minimum limit for all frequency references. The maximum output frequency is 100%.
Sets the lower limit for the master frequency reference (the first frequency of the multi­step speed reference) as a percentage. The maximum output frequency is 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Motor Max Revolutions]
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Motor Max Revolutions]
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
100.0%
(0.0 - 110.0%)
0.0%
(0.0 - 110.0%)
0.0%
(0.0 - 110.0%)
Ref.
232
233
233
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 31
1.7 d: Reference Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

d3: Jump Frequency

No.
(Hex.)
d3-01
(0294)
d3-02
(0295)
d3-03
(0296)
d3-04
(0297)
Name Description
Jump Frequency 1
Sets the median value of the frequency band that the drive will avoid.
Jump Frequency 2
Sets the median value of the frequency band that the drive will avoid.
Jump Frequency 3
Sets the median value of the frequency band that the drive will avoid.
Jump Frequency Width
Sets the width of the frequency band that the drive will avoid.

d4: Frequency Ref Up/Down & Hold

No.
(Hex.)
d4-01
(0298)
d4-03
(02AA)
RUN
d4-04
(02AB)
RUN
d4-05
(02AC)
RUN
d4-06
(02AD)
d4-07
(02AE)
RUN
d4-08
(02AF)
RUN
Name Description
Freq Reference Hold Selection
Sets the function that saves the frequency reference or the frequency bias (Up/Down 2) after a Stop command or when de-energizing the drive.
Set H1-xx [MFDI Function Selection] to one of these values to enable this parameter:
A [Accel/Decel Ramp Hold]
10/11 [Up/Down Command]
75/76 [Up/Down 2 Command]
0 : Disabled
1 : Enabled
Up/Down 2 Bias Step Frequency
Up/Down 2 Ramp Selection
Sets the bias that the Up/Down 2 function adds to or subtracts from the frequency reference.
Sets the acceleration and deceleration times for the Up/Down 2 function to apply the bias to the frequency reference.
0 : Use Selected Accel/Decel Time
1 : Use Accel/Decel Time 4
Up/Down 2 Bias Mode Selection
Sets the function that saves the bias value to the drive when you open or close the two Up/ Down 2 Commands [H1-xx = 75, 76]. Set d4-03 [Up/Down 2 Bias Step Frequency] = 0.00 before you set this parameter.
0 : Hold when Neither Up/Down Closed
1 : Reset when Neither / Both Closed
Frequency Ref Bias (Up/ Down 2)
Saves the bias value from the Up/Down 2 Command where the Maximum Output Frequency is 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Analog Freq Ref Fluctuate Limit
If the frequency reference changes for more than the level set to this parameter, then the bias value will be held. The value is set as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Up/Down 2 Bias Upper Limit
Sets the upper limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
0.0 Hz
(Determined by A1-02)
0.0 Hz
(Determined by A1-02)
0.0 Hz
(Determined by A1-02)
1.0 Hz
(Determined by A1-02)
Default
(Range)
0
(0, 1)
0.00 Hz
(0.00 - 99.99 Hz)
0
(0, 1)
0
(0, 1)
0.0%
(-99.9 - +100.0%)
1.0%
(0.1 - 100.0%)
100.0%
(0.0 - 100.0%)
Ref.
234
234
234
234
Ref.
234
236
237
237
238
238
238
32 YASKAWA TOEPYAIGA5002A GA500 Programming
1.7 d: Reference Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
d4-09
(02B0)
RUN
Name Description
Up/Down 2 Bias Lower Limit
Sets the lower limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
d4-10
(02B6)
Up/Down Freq Lower Limit Select
Sets the lower frequency limit for the Up/Down function.
0 : Greater of d2-02 or Analog
1 : d2-02

d6: Field Weakening /Forcing

No.
(Hex.)
d6-01
(02A0)
d6-02
(02A1)
d6-03
(02A2)
d6-06
(02A5)
Name Description
Field Weakening Level
Sets the drive output voltage as a percentage of E1-05 [Maximum Output Voltage] when H1-xx = 63 [Field Weakening] is activated.
Field Weakening Frequency Limit
Sets the minimum output frequency to start field weakening.
Field Forcing Selection
Sets the field forcing function.
0 : Disabled
1 : Enabled
Field Forcing Limit
Sets the limit value for field forcing to increase the motor excitation current reference as a percentage of E2-03 [Motor No-Load Current]. Usually it is not necessary to change this setting.
Default
(Range)
0.0%
(-99.9 - 0.0%)
0
(0, 1)
Default
(Range)
80%
(0 - 100%)
0.0 Hz
(0.0 - 590.0 Hz)
0
(0, 1)
400%
(100 - 400%)
Ref.
239
239
Ref.
240
240
240
240

d7: Offset Frequency

No.
(Hex.)
d7-01
(02B2)
RUN
d7-02
(02B3)
RUN
d7-03
(02B4)
RUN
Name Description
Offset Frequency 1
Uses H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)] as a percentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
Offset Frequency 2
Uses H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)] as a percentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
Offset Frequency 3
Uses H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)] as a percentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
0.0%
(-100.0 - +100.0%)
0.0%
(-100.0 - +100.0%)
0.0%
(-100.0 - +100.0%)
Ref.
241
241
Parameter List
1
241
YASKAWA TOEPYAIGA5002A GA500 Programming 33

1.8 E: Motor Parameters

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.8 E: Motor Parameters

E1: V/f Pattern for Motor 1

No.
(Hex.)
E1-01
(0300)
E1-03
(0302)
E1-04
(0303)
E1-05
(0304)
E1-06
(0305)
E1-07
(0306)
E1-08
(0307)
E1-09
(0308)
E1-10
(0309)
E1-11
(030A)
Expert
Name Description
Input AC Supply Voltage
Sets the drive input voltage.
NOTICE: Set parameter E1-01 to align with the drive input voltage (not motor voltage). If this parameter is incorrect, the protective functions of the drive will not operate correctly and it can cause damage to the drive.
V/f Pattern Selection
Maximum Output Frequency
Maximum Output Voltage
Base Frequency
Mid Point A Frequency
Mid Point A Voltage
Minimum Output Frequency
Minimum Output Voltage
Mid Point B Frequency
Sets the V/f pattern for the drive and motor. You can use one of the preset patterns or you can make a custom pattern.
0 : Const Trq, 50Hz base, 50Hz max
1 : Const Trq, 60Hz base, 60Hz max
2 : Const Trq, 50Hz base, 60Hz max
3 : Const Trq, 60 Hz base, 72 Hz max
4 : VT, 50Hz, 65% Vmid reduction
5 : VT, 50Hz, 50% Vmid reduction
6 : VT, 60 Hz, 65% Vmid reduction
7 : VT, 60 Hz, 50% Vmid reduction
8 : High Trq, 50Hz, 25% Vmin Boost
9 : High Trq, 50Hz, 65% Vmin Boost
A : High Trq, 60 Hz, 25% Vmin Boost
B : High Trq, 60 Hz, 65% Vmin Boost
C : Const Trq, 60 Hz base, 90 Hz max
D : Const Trq, 60 Hz base, 120 Hz max
E : Const Trq, 60 Hz base, 180 Hz max
F : V/f Pattern Selection
Note:
When A1-02 = 2 [Control Method Selection = OLV], settings 0 to E are not
available.
Set the correct V/f pattern for the application and operation area. An incorrect V/f
pattern can decrease motor torque and increase current from overexcitation.
Sets the maximum output frequency for the V/f pattern.
Sets the maximum output voltage for the V/f pattern.
Sets the base frequency for the V/f pattern.
Sets a middle output frequency for the V/f pattern.
Sets a middle output voltage for the V/f pattern.
Sets the minimum output frequency for the V/f pattern.
Sets the minimum output voltage for the V/f pattern.
Sets a middle output frequency for the V/f pattern.
Default
(Range)
200 V Class: 240 V, 400
V: 480 V
(200 V Class: 155 to 255
V, 400 V Class: 310 to
510 V)
F
(Determined by A1-02)
Determined by A1-02 and
E5-01
(Determined by A1-02
and E5-01)
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
Determined by A1-02 and
E5-01
(0.0 - E1-04)
Determined by A1-02
(0.0 - E1-04)
Determined by A1-02
C6-01 and o2-04
(200 V Class: 0.0 - 255.0
400 V Class: 0.0 - 510.0
Determined by A1-02 and
V,
V)
E5-01
(Determined by A1-02,
E1-04, and E5-01)
Determined by A1-02
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to
510.0 V)
0.0 Hz
(0.0 - E1-04)
Ref.
243
243
248
249
249
249
249
249
249
249
34 YASKAWA TOEPYAIGA5002A GA500 Programming
1.8 E: Motor Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
E1-12
(030B)
Name Description
Mid Point B Voltage
Sets a middle point voltage for the V/f pattern.
Expert
E1-13
(030C)
Base Voltage
Sets the base voltage for the V/f pattern.
Expert

E2: Motor Parameters

No.
(Hex.)
E2-01
(030E)
E2-02
(030F)
E2-03
(0310)
E2-04
(0311)
E2-05
(0312)
E2-06
(0313)
E2-07
(0314)
E2-08
(0315)
E2-09
(0316)
Expert
E2-10
(0317)
E2-11
(0318)
Name Description
Motor Rated Current (FLA)
Sets the motor rated current in amps.
Motor Rated Slip
Sets motor rated slip.
Motor No-Load Current
Sets the no-load current for the motor in amps when operating at the rated frequency and the no-load voltage.
Motor Pole Count
Sets the number of motor poles.
Motor Line-to-Line Resistance
Motor Leakage Inductance
Motor Saturation Coefficient 1
Motor Saturation Coefficient 2
Sets the line-to-line resistance for the motor stator windings.
Sets the voltage drop from motor leakage inductance when the motor is operating at the rated frequency and rated current. This value is a percentage of Motor Rated Voltage.
Sets the motor iron-core saturation coefficient at 50% of the magnetic flux.
Sets the motor iron-core saturation coefficient at 75% of the magnetic flux.
Motor Mechanical Loss
Sets the mechanical loss of the motor. It is set as a percentage of E2-11 [Motor Rated Power]. Usually it is not necessary to change this setting.
Motor Iron Loss
Sets the motor iron loss.
Motor Rated Power
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
Note:
When A1-02 = 0 [Control Method Selection = V/f], the maximum value is 120.
When A1-02 = 2 [OLV], the maximum value is 48.
Default
(Range)
0.0 V
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to
510.0 V)
0.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Default
(Range)
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
Determined by o2-04,
C6-01
(0.000 - 20.000 Hz)
Determined by o2-04,
C6-01
(0 to E2-01)
4
(2 - 120)
Determined by o2-04,
C6-01
(0.000 - 65.000 Ω)
Determined by o2-04,
C6-01
(0.0 - 60.0%)
0.50
(0.00 - 0.50)
0.75
(E2-07 - 0.75)
0.0%
(0.0 - 10.0%)
Determined by o2-04,
C6-01
(0 - 65535 W)
Determined by o2-04,
C6-01
(0.00 - 650.00 HP)
Ref.
250
250
Ref.
250
251
251
251
251
252
252
252
252
252
253
Parameter List

E3: V/f Pattern for Motor 2

No.
(Hex.)
E3-01
(0319)
Name Description
Motor 2 Control Mode Selection
Sets the control method for motor 2.
Default
(Range)
0
(0, 2)
Ref.
253
1
Note:
When you change this setting, the drive will set all parameters that are dependent on this parameter to their default settings.
0 : V/f Control
2 : Open Loop Vector
E3-04
(031A)
Motor 2 Maximum Output Frequency
Set the maximum output frequency for the motor 2 V/f pattern.
Determined by E3-01
(40.0 - 590.0 Hz)
254
YASKAWA TOEPYAIGA5002A GA500 Programming 35
1.8 E: Motor Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
E3-05
(031B)
E3-06
(031C)
E3-07
(031D)
E3-08
(031E)
E3-09
(031F)
E3-10
(0320)
E3-11
(0345)
Expert
E3-12
(0346)
Expert
E3-13
(0347)
Expert
Name Description
Motor 2 Maximum Output Voltage
Sets the maximum output voltage for the motor 2 V/f pattern.
Motor 2 Base Frequency
Sets the base frequency for the motor 2 V/f pattern.
Motor 2 Mid Point A Frequency
Motor 2 Mid Point A Voltage
Motor 2 Minimum Output Frequency
Motor 2 Minimum Output Voltage
Motor 2 Mid Point B Frequency
Motor 2 Mid Point B Voltage
Sets a middle output frequency for the motor 2 V/f pattern.
Sets a middle output voltage for the motor 2 V/f pattern.
Sets the minimum output frequency for the motor 2 V/f pattern.
Sets the minimum output voltage for the motor 2 V/f pattern.
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern for the constant output range. Usually it is not necessary to change this parameter.
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/ f pattern for the constant output range. Usually it is not necessary to change this parameter.
Motor 2 Base Voltage
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern for the constant output range. Usually it is not necessary to change this parameter.
Default
(Range)
Determined by E3-01
(200 V Class: 0.0 - 255.0
400 V Class: 0.0 - 510.0
V,
V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 - 255.0
400 V Class: 0.0 - 510.0
V,
V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 - 255.0
400 V Class: 0.0 - 510.0
V,
V)
0.0 Hz
(0.0 - E3-04)
0.0 V
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to
510.0 V)
0.0 V
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to
510.0 V)
Ref.
254
254
254
254
254
254
254
255
255

E4: Motor 2 Parameters

No.
(Hex.)
E4-01
(0321)
E4-02
(0322)
E4-03
(0323)
E4-04
(0324)
E4-05
(0325)
E4-06
(0326)
E4-07
(0343)
E4-08
(0344)
E4-09
(033F)
Expert
Name Description
Motor 2 Rated Current
Sets the motor rated current for motor 2 in amps.
Motor 2 Rated Slip
Sets the motor rated slip for motor 2.
Motor 2 Rated No-Load Current
Sets the no-load current for motor 2 in amps when operating at the rated frequency and the no-load voltage.
Motor 2 Motor Poles
Sets the number of poles for motor 2.
Motor 2 Line-to-Line Resistance
Motor 2 Leakage Inductance
Motor 2 Saturation Coefficient 1
Motor 2 Saturation Coefficient 2
Sets the line-to-line resistance for the motor 2 stator windings.
Sets the voltage drop from motor 2 leakage inductance as a percentage of Motor Rated Voltage when motor 2 operates at the rated frequency and rated current.
Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.
Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.
Motor 2 Mechanical Loss
Sets the mechanical loss of motor 2. It is set as a percentage of E4-11 [Motor 2 Rated Power]. Usually it is not necessary to change this setting.
Default
(Range)
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
Determined by o2-04,
C6-01
(0.000 - 20.000 Hz)
Determined by o2-04,
C6-01
(0 to E4-01)
4
(2 - 120)
Determined by o2-04,
C6-01
(0.000 - 65.000 Ω)
Determined by o2-04,
C6-01
(0.0 - 60.0%)
0.50
(0.00 - 0.50)
0.75
(E4-07 - 0.75)
0.0%
(0.0 - 10.0%)
Ref.
255
255
256
256
256
256
257
257
257
36 YASKAWA TOEPYAIGA5002A GA500 Programming
1.8 E: Motor Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
E4-10
(0340)
E4-11
(0327)
Name Description
Motor 2 Iron Loss
Sets the motor iron loss for motor 2.
Motor 2 Rated Power
Sets the motor rated power in the units from o1-58 [Motor Power Unit Selection].

E5: PM Motor Settings

No.
(Hex.)
E5-01
(0329)
E5-02
(032A)
E5-03
(032B)
E5-04
(032C)
E5-05
(032D)
E5-06
(032E)
E5-07
(032F)
E5-09
(0331)
E5-24
(0353)
E5-25
(035E)
Expert
Name Description
PM Motor Code Selection
Sets the motor code for Yaskawa PM motors. The drive uses the motor code to automatically set some parameters to their correct settings.
PM Motor Rated Power
Sets the PM motor rated output in the units from o1-58 [Motor Power Unit Selection].
Motor Rated Current (FLA)
Sets the PM motor rated current (FLA).
PM Motor Pole Count
Sets the number of PM motor poles.
Note:
When A1-02 = 5, 6 or 8 [OLV/PM, AOLV/PM or EZOLV], the maximum value is 48.
PM Motor Resistance (ohms/phase)
PM d-axis Inductance (mH/phase)
PM q-axis Inductance (mH/phase)
PM Back-EMF Vpeak (mV/(rad/s))
PM Back-EMF L-L Vrms (mV/rpm)
Polarity Estimation Timeout
Sets the resistance per phase of a PM motor. Set 50% of the line-to-line resistance.
Sets the PM motor d-axis inductance.
Sets the PM motor q-axis inductance.
Sets the peak value of PM motor induced voltage.
Sets the RMS value for PM motor line voltage.
Sets the function that switches polarity for initial polarity estimation. Usually it is not necessary to change this setting.
0 : Disabled
1 : Enabled
Default
(Range)
Determined by o2-04,
C6-01
(0 - 65535 W)
Determined by o2-04,
C6-01
(0.00 - 650.00 HP)
Default
(Range)
FFFF
(0000 - FFFF)
Determined by o2-04,
C6-01
(0.10 - 30.00 kW)
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
4
(2 - 120)
0.100 Ω
(0.000 - 65.000 Ω)
1.00 mH
(0.00 - 300.00 mH)
1.00 mH
(0.00 - 600.00 mH)
0.0 mV/(rad/sec)
(0.0 - 2000.0 mV/(rad/s))
200 V class: 100.0 mV/
400 V class: 200.0 mV/
min
min
-1
-1
(0.0 - 6500.0 mV/min-1)
0
(0, 1)
Ref.
257
257
Ref.
258
258
258
258
259
259
259
259
260
260

E9: Motor Setting

No.
(Hex.)
E9-01
(11E4)
Name Description
Motor Type Selection
Sets the type of motor.
Default
(Range)
0
(0 to 2)
Ref.
260
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
E9-02
(11E5)
E9-03
(11E6)
E9-04
(11E7)
Maximum Speed
Rated Speed
Base Frequency
Sets the maximum speed of the motor.
Sets the rated rotation speed of the motor.
Sets the rated frequency of the motor.
Determined by E9-01
(40.0 - 120.0 Hz)
Determined by E9-01
(100 - 7200 min
-1
Determined by E9-01
(40.0 - 120.0 Hz)
260
261
)
261
YASKAWA TOEPYAIGA5002A GA500 Programming 37
Parameter List
1
1.8 E: Motor Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
E9-05
(11E8)
E9-06
(11E9)
E9-07
(11EA)
E9-08
(11EB)
E9-09
(11EC)
E9-10
(11ED)
Name Description
Motor Rated Voltage
Sets the rated voltage of the motor.
Motor Rated Current (FLA)
Sets the motor rated current in amps.
Motor Rated Power
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
Motor Pole Count
Sets the number of motor poles.
Motor Rated Slip
Sets the motor rated slip.
Motor Line-to-Line Resistance
Sets the line-to-line resistance for the motor stator windings.
Default
(Range)
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Determined by E9-01 and
o2-04
(10% to 200% of the
drive rated current)
Determined by E9-02 and
o2-04
(0.00 - 650.00 kW)
4
(2 to 120)
0.000 Hz
(0.000 - 20.000 Hz)
Determined by o2-04
(0.000 - 65.000 Ω)
Ref.
261
261
261
262
262
262
38 YASKAWA TOEPYAIGA5002A GA500 Programming
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

F1: Fault Detection in PG Speed Control

1.9 F: Options

No.
(Hex.)
F1-02
(0381)
F1-03
(0382)
F1-04
(0383)
F1-08
(0387)
F1-09
(0388)
F1-10
(0389)
Name Description
Encoder Signal Loss Detect Sel
Sets the method to stop the motor or let the motor continue operating when the drive detects PGo [Encoder (PG) Feedback Loss].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Overspeed Detection Selection
Sets the method to stop the motor or let the motor continue to operate when the drive detects oS [Overspeed].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Speed Deviation Detection Select
Sets the method to stop the motor or let the motor continue to operate when the drive detects dEv [Speed Deviation].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Overspeed Detection Level
Sets the detection level of oS [Overspeed] as a percentage when the maximum output frequency is 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the
maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]A1-02 = 8: E9-02 [Motor Max Revolutions]
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP
Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Overspeed Detection Delay Time
Sets the length of time that the speed feedback must be more than the F1-08 level to cause oS [Overspeed].
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Speed Deviation Detection Level
Sets the detection level of dEv [Speed Deviation] as a percentage when the maximum output frequency is 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the
maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]A1-02 = 8: E9-02 [Maximum Speed]
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP
Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Default
(Range)
1
(0 - 4)
1
(0 - 3)
3
(0 - 3)
115%
(0 - 120%)
Determined by A1-02
(0.0 - 2.0 s)
10%
(0 - 50%)
Ref.
263
263
264
264
265
265
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 39
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F1-11
(038A)
Name Description
Speed Deviation Detect DelayTime
Sets the length of time that the difference between the frequency reference and speed feedback must be more than the level in F1-10 to cause dEv [Speed Deviation].
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
F1-14
(038D)
Encoder Open-Circuit Detect Time
Sets the length of time that the drive must not receive a pulse signal to cause PGo [Encoder (PG) Feedback Loss].
Note:
Motor speed and load conditions can cause ov [Overvoltage] and oC [Overcurrent] faults.
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.

F6: Communication Options

No.
(Hex.)
F6-01
(03A2)
F6-02
(03A3)
F6-03
(03A4)
F6-04
(03A5)
F6-06
(03A7)
F6-07
(03A8)
F6-08
(036A)
Name Description
Communication Error Selection
Sets the method to stop the motor or let the motor continue operating when the drive detects bUS [Option Communication Error].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Alarm (Run at d1-04)
5 : Alarm - Ramp Stop
Comm External Fault (EF0) Detect
Sets the conditions at which EF0 [Option Card External Fault] is detected.
0 : Always Detected
1 : Detected during RUN Only
Comm External Fault (EF0) Select
Sets the method to stop the motor or let the motor continue operating when the drive detects EF0 [Option Card External Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
bUS Error Detection Time
Sets the delay time for the drive to detect bUS [Option Communication Error].
Note:
When you install a CC-Link option (SI-C3) to the drive, the setting value changes to
0.0 s.
Torque Reference/Limit by Comm
Sets the function that enables and disables the torque reference and torque limit received from the communication option.
0 : Disabled
1 : Enabled
Multi-Step Ref @ NetRef/ComRef
Sets the function that enables and disables the multi-step speed reference when the freqency reference source is NetRef or ComRef (communication option card or MEMOBUS/Modbus communications).
0 : Disable Multi-Step References
1 : Enable Multi-Step References
Comm Parameter Reset @Initialize
Sets the function to initialize F6-xx and F7-xx parameters when the drive is initialized with A1-03 [Initialize Parameters].
0 : No Reset - Parameters Retained
1 : Reset Back to Factory Default
Default
(Range)
0.5 s
(0.0 - 10.0 s)
2.0 s
(0.0 - 10.0 s)
Default
(Range)
1
(0 - 5)
0
(0, 1)
1
(0 - 3)
2.0 s
(0.0 - 12.0 s)
0
(0, 1)
1
(0, 1)
0
(0, 1)
Ref.
265
265
Ref.
271
272
272
272
272
273
273
40 YASKAWA TOEPYAIGA5002A GA500 Programming
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F6-10
(03B6)
F6-11
(03B7)
F6-14
(03BB)
F6-15
(0B5B)
F6-16
(0B8A)
F6-20
(036B)
F6-21
(036C)
F6-22
(036D)
F6-23
(036E)
F6-24
(036F)
Name Description
CC-Link Node Address
Sets the node address for CC-Link communication. Restart the drive after you change the parameter setting.
Note:
Be sure to set a node address that is different than all other node addresses. Do not set this parameter to 0. Incorrect parameter settings will cause AEr [Station Address Setting Error] errors and the L.ERR LED on the option will come on.
CC-Link Communication Speed
Sets the communication speed for CC-Link communication. Restart the drive after you change the parameter setting.
0 : 156 kbps
1 : 625 kbps
2 : 2.5 Mbps
3 : 5 Mbps
4 : 10 Mbps
BUS Error Auto Reset
Sets the automatic reset function for bUS [Option Communication Errors].
0 : Disabled
1 : Enabled
Comm. Option Parameters Reload
Sets the update method when you change F6-xx, F7-xx [Communication Options].
0 : Reload at Next Power Cycle
1 : Reload Now
2 : Cancel Reload Request
Gateway Mode
Sets the gateway mode operation and the number of connected slave drives.
0 : Disabled
1 : Enabled: 1 Slave Drives
2 : Enabled: 2 Slave Drives
3 : Enabled: 3 Slave Drives
4 : Enabled: 4 Slave Drives
MECHATROLINK Station Address
Sets the station address for MECHATROLINK communication. Change the parameter then cycle power on the drive.
Note:
The setting range changes if using MECHATROLINK-II or MECHATROLINK-III:MECHATROLINK-II (SI-T3) range: 20 - 3F
MECHATROLINK-III (SI-ET3) range: 03 - EF
Be sure to set a node address that is different than all other node addresses. Incorrect
parameter settings will cause AEr [Station Address Setting Error] errors and the L. ERR LED on the option will come on.
The drive detects AEr errors when the station address is 20 or 3F.
MECHATROLINK Frame Size
Sets the frame size for MECHATROLINK communication. Restart the drive after you change the parameter setting.
0 : 32byte (M-2) / 64byte (M-3)
1 : 17byte (M-2) / 32byte (M-3)
MECHATROLINK Link Speed
Sets the communications speed for MECHATROLINK-II. Restart the drive after you change the parameter setting.
Note:
This parameter is only available with the MECHATROLINK-II option.
0 : 10 Mbps
1 : 4 Mbps
MECHATROLINK Monitor Select (E)
MECHATROLINK Monitor Select (F)
Sets the MEMOBUS register used for the monitor functions of INV_CTL (drive operation control command) and INV_I/O (drive I/O control command). Restart the drive after you change the parameter setting.
Sets the MEMOBUS register used for the monitor functions of INV_CTL (drive operation control command) and INV_I/O (drive I/O control command). Restart the drive after you change the parameter setting.
Default
(Range)
0
(0 - 64)
0
(0 - 4)
0
(0, 1)
0
(0 - 2)
0
(0 to 4)
0021h
(MECHATROLINK-II:
0020h - 003Fh,
MECHATROLINK-III:
0003h - 00EFh)
0
(0, 1)
0
(0, 1)
0000h
(0000h - FFFFh)
0000h
(0000h - FFFFh)
Ref.
273
273
274
274
274
274
275
275
Parameter List
1
275
275
YASKAWA TOEPYAIGA5002A GA500 Programming 41
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F6-25
(03C9)
F6-26
(03CA)
F6-30
(03CB)
F6-31
(03CC)
F6-32
(03CD)
F6-35
(03D0)
F6-36
(03D1)
F6-50
(03C1)
F6-51
(03C2)
F6-52
(03C3)
Name Description
MECHATROLINK Watchdog Error Sel
Sets the method to stop the motor or let the motor continue operating when the drive detects E5 [MECHATROLINK Watchdog Timer Err].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
MECHATROLINK Allowable No of Err
PROFIBUS-DP Node Address
Sets the number of times that the option must detect a bUS alarm to cause a bUS [Option Communication Error].
Sets the node address for PROFIBUS-DP communication. Restart the drive after you change the parameter setting.
Note:
Be sure to set an address that is different than all other node addresses. Do not set this parameter to 0.
PROFIBUS-DP Clear Mode Selection
Sets what the drive will do after it receives the Clear Mode command.
0 : Reset
1 : Hold Previous State
PROFIBUS-DP Data Format Select
Sets the data format of PROFIBUS-DP communication. Restart the drive after you change the parameter setting.
0 : PPO Type
1 : Conventional
2 : PPO (bit0)
3 : PPO (Enter)
4 : Conventional (Enter)
5 : PPO (bit0, Enter)
CANopen Node ID Selection
Sets the node address for CANopen communication. Restart the drive after you change the parameter setting.
Note:
Be sure to set an address that is different than all other node addresses. Do not set this parameter to 0. Incorrect parameter settings will cause AEr [Station Address Setting Error] errors and the L.ERR LED on the option will come on.
CANopen Communication Speed
Sets the CANopen communications speed. Restart the drive after you change the parameter setting.
0 : Detect Automatically
1 : 10 kbps
2 : 20 kbps
3 : 50 kbps
4 : 125 kbps
5 : 250 kbps
6 : 500 kbps
7 : 800 kbps
8 : 1 Mbps
DeviceNet MAC Address
Sets the MAC address for DeviceNet communication. Restart the drive after you change the parameter setting.
Note:
Be sure to set a MAC address that is different than all other node addresses. Do not set this parameter to 0. Incorrect parameter settings will cause AEr [Station Address Setting Error] errors and the MS LED on the option will flash.
DeviceNet Baud Rate
Sets the DeviceNet communications speed. Restart the drive after you change the parameter setting.
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
3 : Adjustable from Network
4 : Detect Automatically
DeviceNet PCA Setting
Sets the format of data that the DeviceNet communication master sends to the drive.
Default
(Range)
1
(0 - 3)
2
(2 - 10 times)
0
(0 - 125)
0
(0, 1)
0
(0 - 5)
0
(0 - 126)
6
(0 - 8)
64
(0 - 64)
4
(0 - 4)
21
(0 - 255)
Ref.
275
276
276
276
276
277
277
277
277
278
42 YASKAWA TOEPYAIGA5002A GA500 Programming
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F6-53
(03C4)
F6-54
(03C5)
F6-55
(03C6)
F6-56
(03D7)
F6-57
(03D8)
F6-58
(03D9)
F6-59
(03DA)
F6-60
(03DB)
F6-61
(03DC)
F6-62
(03DD)
F6-63
(03DE)
F6-64 to F6-67
(03DF - 03E2)
F6-68 to F6-71
(03E3, 03E4,
03C7, and
03C8)
F6-72
(081B)
Name Description
DeviceNet PPA Setting
Sets the format of data that the drive sends to the DeviceNet communication master.
DeviceNet Idle Fault Detection
Sets the function to detect EF0 [Option Card External Fault] when the drive does not receive data from the DeviceNet master.
0 : Enabled
1 : Disabled, No Fault Detection
2 : Vendor Specific
3 : RUN Forward
4 : Reverse run
DeviceNet Baud Rate Monitor
Sets the function to see the actual DeviceNet communications speed using the keypad. This parameter functions as a monitor only.
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
DeviceNet Speed Scaling
Sets the speed scale for DeviceNet communication.
DeviceNet Current Scaling
DeviceNet Torque Scaling
Sets the current scale of the DeviceNet communication master.
Sets the torque scale of the DeviceNet communication master.
DeviceNet Power Scaling
Sets the power scale of the DeviceNet communication master.
DeviceNet Voltage Scaling
Sets the voltage scale of the DeviceNet communication master.
DeviceNet Time Scaling
Sets the time scale of the DeviceNet communication master.
DeviceNet Heartbeat Interval
DeviceNet Network MAC ID
Dynamic Out Assembly 109 Param 1 to 4
Dynamic In Assembly 159 Param 1 to 4
Sets the heartbeat for DeviceNet communication. Set this parameter to 0 to disable the heartbeat function.
Sets the function to see the actual DeviceNet MAC address using the keypad. This parameter functions as a monitor only.
Sets Configurable Outputs 1 to 4 written to the MEMOBUS register.
Sets Configurable Inputs 1 to 4 read from the MEMOBUS register.
PowerLink Node Address
Sets the node ID for PowerLink communication.
Note:
Be sure to set an address that is different than all other node addresses. Do not set this parameter to 0.
Default
(Range)
71
(0 - 255)
0
(0 - 4)
0
(0 - 2)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(0 - 10)
63
(0 - 63)
0000h
(0000h - FFFFh)
0000h
(0000h - FFFFh)
0
(0 - 255)
Ref.
278
278
278
278
278
279
279
279
279
279
279
279
279
280
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 43
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

F7: Communication Options

No.
(Hex.)
F7-01
(03E5)
F7-02
(03E6)
F7-03
(03E7)
F7-04
(03E8)
F7-05
(03E9)
F7-06
(03EA)
F7-07
(03EB)
F7-08
(03EC)
F7-09
(03ED)
F7-10
(03EE)
F7-11
(03EF)
Name Description
IP Address 1
Sets the first octet of the IP Address for the device that is connecting to the network. Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
IP Address 2
Sets the second octet of the IP Address for the device that is connecting to the network. Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
IP Address 3
Sets the third octet of the IP Address for the device that is connecting to the network. Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
IP Address 4
Sets the fourth octet of the IP Address for the device that is connecting to the network. Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
Subnet Mask 1
Sets the first octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Subnet Mask 2
Sets the second octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Subnet Mask 3
Sets the third octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Subnet Mask 4
Sets the fourth octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Gateway Address 1
Sets the first octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Gateway Address 2
Sets the second octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Gateway Address 3
Sets the third octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Default
(Range)
192
(0 - 255)
168
(0 - 255)
1
(0 - 255)
20
(0 - 255)
255
(0 - 255)
255
(0 - 255)
255
(0 - 255)
0
(0 - 255)
192
(0 - 255)
168
(0 - 255)
1
(0 - 255)
Ref.
280
280
280
280
280
281
281
281
281
281
281
44 YASKAWA TOEPYAIGA5002A GA500 Programming
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F7-12
(03F0)
F7-13
(03F1)
F7-14
(03F2)
F7-15
(03F3)
F7-16
(03F4)
F7-17
(03F5)
F7-18
(03F6)
F7-19
(03F7)
F7-20
(03F8)
F7-21
(03F9)
F7-22
(03FA)
F7-23
(03FB)
F7-24
(03FC)
Name Description
Gateway Address 4
Sets the fourth octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Address Mode at Startup
Sets the method to set option card IP addresses.
0 : Static
1 : BOOTP
2 : DHCP
Note:
The following setting values are available when using the PROFINET communication option card (SI-EP3).
0: Static2: DHCP
When F7-13 = 0, set parameters F7-01 to F7-12 [IP Address 1 to Gateway Address
4] to set the IP Address. Be sure to set a different IP address for each drive on the network.
Duplex Mode Selection
Sets the duplex mode setting method.
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
4 : Half/Full
5 : Auto/Half
6 : Auto/Full
7 : Full/Half
8 : Full/Auto
Communication Speed Selection
Sets the communications speed.
10 : 10/10 Mbps
100 : 100/100 Mbps
101 : 10/100 Mbps
102 : 100/10 Mbps
Timeout Value
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout function.
EtherNet/IP Speed Scaling Factor
EtherNet/IP Current Scale Factor
EtherNet/IP Torque Scale Factor
EtherNet/IP Power Scaling Factor
EtherNet/IP Voltage Scale Factor
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
EtherNet/IP Time Scaling
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
Dynamic Out Param 1 for CommCard
Dynamic Out Param 2 for CommCard
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set this parameter to set to configurable output 1.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set this parameter to set to configurable output 2.
Default
(Range)
1
(0 - 255)
2
(0 - 2)
1
(0 - 8)
10
(10, 100 - 102)
0.0 s
(0.0 - 30.0 s)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0 284
0 284
Ref.
282
282
282
282
283
283
283
283
283
283
283
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 45
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F7-25
(03FD)
F7-26
(03FE)
F7-27
(03FF)
F7-28
(0370)
F7-29
(0371)
F7-30
(0372)
F7-31
(0373)
F7-32
(0374)
F7-33
(0375)
F7-34
(0376)
F7-35
(0377)
F7-36
(0378)
F7-37
(0379)
Name Description
Dynamic Out Param 3 for CommCard
Dynamic Out Param 4 for CommCard
Dynamic Out Param 5 for CommCard
Dynamic Out Param 6 for CommCard
Dynamic Out Param 7 for CommCard
Dynamic Out Param 8 for CommCard
Dynamic Out Param 9 for CommCard
Dynamic Out Param 10 for CommCard
Dynamic In Param 1 for CommCard
Dynamic In Param 2 for CommCard
Dynamic In Param 3 for CommCard
Dynamic In Param 4 for CommCard
Dynamic In Param 5 for CommCard
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set this parameter to set to configurable output 3.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set this parameter to set to configurable output 4.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set this parameter to set to configurable output 5.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the values from Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set this parameter to set to configurable input 1.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set this parameter to set to configurable input 2.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set this parameter to set to configurable input 3.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set this parameter to set to configurable input 4.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set this parameter to set to configurable input 5.
Default
(Range)
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
Ref.
46 YASKAWA TOEPYAIGA5002A GA500 Programming
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F7-38
(037A)
F7-39
(037B)
F7-40
(037C)
F7-41
(037D)
F7-42
(037E)
F7-60
(0780)
F7-61
(0781)
F7-62
(0782)
F7-63
(0783)
F7-64
(0784)
F7-65
(0785)
F7-66
(0786)
F7-67
(0787)
F7-68
(0788)
F7-69
(0789)
F7-70
(078A)
F7-71
(078B)
Name Description
Dynamic In Param 6 for CommCard
Dynamic In Param 7 for CommCard
Dynamic In Param 8 for CommCard
Dynamic In Param 9 for CommCard
Dynamic In Param 10 for CommCard
PZD1 Write (Control Word)
PZD2 Write (Frequency Reference)
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the values from the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The drive returns the default register value for the option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO output) functions as the STW when F7-60 = 0 to 2.
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO output). PZD2 (PPO output) functions as the HSW when F7-61 = 0 to 2.
PZD3 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will disable the PZD3 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD4 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO output). A value of 0, 1, or 2 will disable the PZD4 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD5 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO output). A value of 0, 1, or 2 will disable the PZD5 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD6 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO output). A value of 0, 1, or 2 will disable the PZD6 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD7 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO output). A value of 0, 1, or 2 will disable the PZD7 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD8 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO output). A value of 0, 1, or 2 will disable the PZD8 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD9 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO output). A value of 0, 1, or 2 will disable the PZD9 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD10 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO output). A value of 0, 1, or 2 will disable the PZD10 (PPO output) write operation to the MEMOBUS/Modbus register.
PZD1 Read (Status Word)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO input). PZD1 (PPO input) functions as the ZSW when F7-70 = 0.
PZD2 Read (Output Frequency)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO input). PZD2 (PPO input) functions as the HIW when F7-71 = 0.
Default
(Range)
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 284
0 285
0 285
0 285
0 285
0 285
0 285
0 285
Ref.
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 47
1.9 F: Options
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
F7-72
(078C)
F7-73
(078D)
F7-74
(078E)
F7-75
(078F)
F7-76
(0790)
F7-77
(0791)
F7-78
(0792)
F7-79
(0793)
Name Description
PZD3 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO input). A value of 0 will disable the PZD3 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD4 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO input). A value of 0 will disable the PZD4 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD5 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO input). A value of 0 will disable the PZD5 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD6 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO input). A value of 0 will disable the PZD6 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD7 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO input). A value of 0 will disable the PZD7 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD8 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO input). A value of 0 will disable the PZD8 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD9 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO input). A value of 0 will disable the PZD9 (PPO input) load operation from the MEMOBUS/Modbus register.
PZD10 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO input). A value of 0 will disable the PZD10 (PPO input) load operation from the MEMOBUS/Modbus register.
Default
(Range)
0 286
0 286
0 286
0 286
0 286
0 286
0 286
0 286
Ref.
48 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

H1: Digital Inputs

1.10 H: Terminal Functions

No.
(Hex.)
H1-01
(0438)
H1-02
(0439)
H1-03
(0400)
H1-04
(0401)
H1-05
(0402)
H1-06
(0403)
H1-07
(0404)
H1-21
(0B70)
H1-22
(0B71)
H1-23
(0B72)
H1-24
(0B73)
H1-25
(0B74)
H1-26
(0B75)
H1-27
(0B76)
H1-40
(0B54)
H1-41
(0B55)
H1-42
(0B56)
Name Description
Terminal S1 Function Selection
Sets the function for MFDI terminal S1.
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default setting is F.
Terminal S2 Function Selection
Sets the function for MFDI terminal S2.
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default setting is F.
Terminal S3 Function Selection
Terminal S4 Function Selection
Terminal S5 Function Selection
Sets the function for MFDI terminal S3.
Sets the function for MFDI terminal S4.
Sets the function for MFDI terminal S5.
Note:
When you set 3-Wire Initialization [A1-03 = 3330] to initialize the drive, the default setting is 0.
Terminal S6 Function Selection
Sets the function for MFDI terminal S6.
Note:
When you set 3-Wire Initialization [A1-03 = 3330] to initialize the drive, the default setting is 3.
Terminal S7 Function Selection
Sets the function for MFDI terminal S7.
Note:
When you set 3-Wire Initialization [A1-03 = 3330] to initialize the drive, the default setting is 4.
Terminal S1 Function Selection 2
Terminal S2 Function Select 2
Terminal S3 Function Selection 2
Terminal S4 Function Selection 2
Terminal S5 Function Selection 2
Terminal S6 Function Selection 2
Terminal S7 Function Selection 2
Mbus Reg 15C0h bit0 Input Func
Mbus Reg 15C0h bit1 Input Func
Mbus Reg 15C0h bit2 Input Func
Sets the second function for MFDI terminal S1.
Sets the second function for MFDI terminal S2.
Sets the second function for MFDI terminal S3.
Sets the second function for MFDI terminal S4.
Sets the second function for MFDI terminal S5.
Sets the second function for MFDI terminal S6.
Sets the second function for MFDI terminal S7.
Sets MFDI function to set to bit 0 of the MEMOBUS register 15C0 (Hex.).
Sets MFDI function to set to bit 1 of the MEMOBUS register 15C0 (Hex.).
Sets MFDI function to set to bit 2 of the MEMOBUS register 15C0 (Hex.).
Default
(Range)
40
(1 - 1FF)
41
(1 - 1FF)
24
(0 - 1FF)
14
(0 - 1FF)
3
(0 - 1FF)
4
(0 - 1FF)
6
(0 - 1FF)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
Ref.
288
288
288
288
288
289
289
289
289
289
289
290
290
290
290
290
291
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 49
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
H1-xx: MFDI Setting Values
Setting Value Function Description Ref.
0 3-Wire Sequence
1 LOCAL/REMOTE
Selection
2 External Reference 1/2
Selection
3 Multi-Step Speed
Reference 1
4 Multi-Step Speed
Reference 2
5 Multi-Step Speed
Reference 3
6 Jog Reference Selection
7 Accel/Decel Time
Selection 1
8 Baseblock Command (N.
O.)
9 Baseblock Command (N.
C.)
A Accel/Decel Ramp Hold
B Overheat Alarm (oH2)
C Analog Terminal Enable
Selection
E ASR Integral Reset
F Not Used
10 Up Command
11 Down Command
12 Forward Jog
Sets the direction of motor rotation for 3-wire sequence.
Sets drive control for the keypad (LOCAL) or an external source (REMOTE).
ON : LOCAL
OFF : REMOTE
Sets the drive to use Run command source 1/2 or Reference command source 1/2 when in REMOTE Mode.
ON : b1-15 = [Frequency Reference Selection 2], b1-16 [Run Command Selection 2]
OFF : b1-01 = [Frequency Reference Selection 1], b1-02 [Run Command Selection 1]
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
Sets the drive to use the JOG Frequency Reference (JOG command) set in d1-17. The JOG Frequency Reference (JOG command) overrides Frequency References 1 to 16 (d1-01 to d1-16).
Sets the drive to use Acceleration/Deceleration Time 1 [C1-01, C1-02] or Acceleration/Deceleration Time 2 [C1-03, C1-04].
Sets the command that stops drive output and coasts the motor to stop when the input is ON.
ON : Baseblock (drive output stop)
OFF : Normal operation
Sets the command that stops drive output and coasts the motor to stop when the input terminal is OFF.
ON : Normal operation
OFF : Baseblock (drive output stop)
Momentarily pauses motor acceleration and deceleration when the terminal is turned ON, retains the output frequency that was stored in the drive at the time of the pause, and restarts motor operation.
Sets the drive to display an oH2 [Drive Overheat Warning] alarm when the input terminal is ON. The alarm does not have an effect on drive operation.
Sets the command that enables or disables the terminals selected in H3-14 [Analog Input Terminal Enable Sel].
ON : Input to the terminal selected with H3-14 is enabled
OFF : Input to the terminal selected with H3-14 is disabled
Sets the command to reset the integral value and use PI control or P control for the speed control loop.
ON : P control
OFF : PI control
Use this setting for unused terminals or to use terminals in through mode.
Sets the command to use a push button switch to increase the drive frequency reference. You must also set Setting 11 [Down Command].
ON : Increases the frequency reference.
OFF : Holds the current frequency reference.
Sets the command to use a push button switch to decrease the drive frequency reference. You must also set Setting 10 [Up Command].
ON : Decreases the frequency reference.
OFF : Holds the current frequency reference.
Sets the command to operate the motor in the forward direction at the Jog Frequency set in d1-17 [Jog Reference].
291
292
292
292
292
292
293
293
293
293
293
294
294
294
294
294
296
297
50 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
13 Reverse Jog
14 Fault Reset
15 Fast Stop (N.O.)
16 Motor 2 Selection
17 Fast Stop (N.C.)
18 Timer Function
19 PID Disable
1A Accel/Decel Time
Selection 2
1B Programming Lockout
1E Reference Sample Hold
20 to 2F External fault
30 PID Integrator Reset
31 PID Integrator Hold
32 Multi-Step Speed
Reference 4
34 PID Soft Starter Disable
Sets the command to operate the motor in reverse at the Jog Frequency set in d1-17 [Jog Reference].
Sets the command to reset the current fault when the Run command is inactive.
Note:
The drive ignores the fault reset command when the Run command is active. Remove the Run command before trying to reset a fault.
Sets the command to ramp to stop in the deceleration time set in C1-09 [Fast Stop Time] when the input terminal is activated while the drive is operating.
Sets the command for the drive to operate motor 1 or motor 2. Stop the motors before switching.
ON : Operate motor 2
OFF : Operate motor 1
Sets the command to ramp to stop in the deceleration time set in C1-09 [Fast Stop Time] when the input terminal is activated while the drive is operating.
Sets the command to start the timer function. Use this setting with Timer Output [H2-xx = 12].
Sets the command to disable PID control when b5-01 = 1 to 8 [PID Mode Setting = Enabled].
ON : PID control disabled
OFF : PID control enabled
Set this function and H1-xx = 7[Accel/Decel Time Selection 1] together. Sets the drive to use Acceleration/ Deceleration Time 3 [C1-05, C1-06] or Acceleration/Deceleration Time 4 [C1-07, C1-08].
Sets the command to prevent parameter changes when the terminal is OFF.
ON : Programming Lockout
OFF : Parameter Write Prohibit
Sets the command to sample the frequency reference at terminal A1 or A2, and hold the frequency reference at that frequency.
Sets a command to stop the drive when a failure or fault occurs on an external device.
20 : External Fault (NO-Always-Ramp)
21 : External Fault (NC-Always-Ramp)
22 : External Fault (NO-@Run-Ramp)
23 : External Fault (NC-@Run-Ramp)
24 : External Fault (NO-Always-Coast)
25 : External Fault (NC-Always-Coast)
26 : External Fault (NO-@Run-Coast)
27 : External Fault (NC-@Run-Coast)
28 : External Fault (NO-Always-FStop)
29 : External Fault (NC-Always-FStop)
2A : External Fault (NO-@Run-FStop)
2B : External Fault (NC-@Run-FStop)
2C : External Fault (NO-Always-Alarm)
2D : External Fault (NC-Always-Alarm)
2E : External Fault (NO-@Run-Alarm)
2F : External Fault (NC-@Run-Alarm)
Sets the command to reset and hold the PID control integral to 0 when the terminal is ON.
Sets the command to hold the integral value of the PID control while the terminal is activated.
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
Sets the PID soft starter function.
ON : No
OFF : Yes
297
297
297
298
298
299
299
299
299
299
300
301
301
301
301
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 51
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
35 PID Input (Error) Invert
3E PID Setpoint Selection 1
3F PID Setpoint Selection 2
40 Forward RUN (2-Wire)
41 Reverse RUN (2-Wire)
42 Run Command (2-Wire
43 FWD/REV (2-Wire
44 Add Offset Frequency 1
45 Add Offset Frequency 2
46 Add Offset Frequency 3
Sequence 2)
Sequence 2)
(d7-01)
(d7-02)
(d7-03)
47 Node Setup (CANopen)
60 DC Injection Braking
Command
61 Speed Search from Fmax
Sets the command to turn the terminal ON and OFF to switch the PID input level (polarity).
Set this function and H1-xx = 3F [PID Setpoint Selection 2] together. Sets the function to switch the PID setpoint to b5-58 to b5-60 [PID Setpoint 2 to 4].
Set this function and H1-xx = 3E [PID Setpoint Selection 1] at the same time. Sets the function to switch the PID setpoint to b5-58 to b5-60 [PID Setpoint 2 to 4].
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 41 [Reverse Run Command (2- Wire Seq)] at the same time.
ON : Forward Run
OFF : Run Stop
Note:
If you activate the Forward Run command terminal and the Reverse Run command terminal, the drive will detect
minor fault/alarm EF [FWD/REV Run Command Input Error] and the motor will ramp to stop.
Initialize the drive with a 2-wire sequence to set the Forward Run command to terminal S1.
This function will not operate at the same time as H1-xx = 42, 43 [Run Command/FWD/REV Command (2-Wire
Seq 2)].
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 40 [Forward Run Command (2- Wire Seq)] at the same time.
ON : Reverse Run
OFF : Run Stop
Note:
If you activate the Forward Run command terminal and the Reverse Run command terminal, the drive will detect
minor fault/alarm EF [FWD/REV Run Command Input Error] and the motor will ramp to stop.
Initialize the drive with a 2-wire sequence to set the Reverse Run command to terminal S2.
This function will not operate at the same time as H1-xx = 42, 43 [Run Command/FWD/REV Command (2-Wire
Seq 2)].
Sets the Run command for 2-wire sequence 2. Set this function and H1-xx = 43 [FWD/REV Command (2-Wire Seq 2)] at the same time.
ON : Run
OFF : Stop
Note:
This function will not operate at the same time as H1-xx = 40, 41 [Forward/Reverse Run Command (2-Wire Seq)].
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 42 [Run Command (2-Wire Sequence 2)] together.
ON : Reverse run
OFF : Forward run
Note:
This function will not operate at the same time as H1-xx = 40, 41 [Forward/Reverse Run Command (2-Wire Seq)].
Sets the function to add the offset frequency set in d7-01 [Offset Frequency 1] to the frequency reference when the terminal activates.
Sets the function to add the offset frequency set in d7-02 [Offset Frequency 2] to the frequency reference when the terminal activates.
Sets the function to add the offset frequency set in d7-03 [Offset Frequency 3] to the frequency reference when the terminal activates.
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the host controller.
Sets the command to use DC Injection Braking to stop the motor.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available with a PM motor.
Sets the function to start speed search using an external reference although b3-01 = 0 [Speed Search Selection at Start = Disabled].
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 61 and 62 are set at the same time.
302
302
302
302
302
303
303
303
303
303
304
304
304
52 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
62 Speed Search from Fref
63 Field Weakening
65 KEB Ride-Thru 1
66 KEB Ride-Thru 1
67 Communications Test
68 High Slip Braking (HSB)
Activate (N.C.)
Activate (N.O.)
Mode
Activate
6A Drive Enable
75 Up 2 Command
76 Down 2 Command
77 ASR Gain (C5-03) Select
7A KEB Ride-Thru 2
7B KEB Ride-Thru 2
7C Short Circuit Braking (N.
7D Short Circuit Braking (N.
Activate (N.C.)
Activate (N.O.)
O.)
C.)
Sets the function to use an external reference to start speed search although b3-01 = 0 [Speed Search Selection at Start = Disabled].
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 61 and 62 are set at the same time.
Sets the function to send the Field Weakening Level and Field Weakening Frequency Limit commands set in d6-01 [Field Weakening Level] and d6-02 [Field Weakening Frequency Limit] when the input terminal is activated.
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
Set the function for the drive to self-test RS-485 serial communications operation.
Sets the command to use high-slip braking to stop the motor.
Sets the function to show dnE [Drive Enabled] on the keypad and ignore Run commands when the terminal is OFF.
Sets the function to increase the frequency reference bias value to accelerate the motor when the terminal is activated. Set this function and H1-xx = 76 [Down 2 Command] together.
Note:
When you use this function, use d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit] to set the optimal bias limit value.
Sets the function to decrease the frequency reference bias value to decelerate the motor when the terminal is activated. Set this function and H1-xx = 75 [Up 2 Command] at the same time.
Note:
When you use this function, use d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit] to set the optimal bias limit value.
Sets the function to switch the ASR proportional gain set in C5-01 [ASR Proportional Gain 1] and C5-03 [ASR Proportional Gain 1/2].
ON : C5-03
OFF : C5-01
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
Sets operation of Short Circuit Braking (N.O.).
ON : Short Circuit Braking is enabled.
OFF : Normal operation
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
Sets operation of Short Circuit Braking (N.C.).
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
304
304
305
305
305
305
305
306
307
307
307
308
308
308
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 53
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
7E Reverse Rotation
Identifier
Set the motor rotation direction when you use Simple Closed Loop V/f Control method.
ON : Reverse run
OFF : Forward run
90 - 96 DWEZ Digital Inputs 1 to
7
Sets digital inputs used with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
9F DWEZ Disable
Sets operation of the DriveWorksEZ program saved in the drive.
ON : No
OFF : Yes
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to enable this function.
101 to 19F Inverse Input of 1 to 9F Sets the function of the selected MFDI to operate inversely. To select the function, enter 1xx, where the xxis the
function setting value.
Note:
You cannot use inverse input for all functions. Refer to Table 2.49 for more information.

H2: Digital Outputs

308
308
309
309
No.
(Hex.)
H2-01
(040B)
H2-02
(040C)
H2-03
(040D)
H2-06
(0437)
H2-07
(0B3A)
H2-08
(0B3B)
H2-09
(0B3C)
H2-10
(0B3D)
H2-20
(1540)
H2-21
(1541)
H2-22
(1542)
Name Description
Term MA/MB-MC Function Selection
Sets the function set for MFDO terminal MA-MC or MB-MC.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in through mode.
Term P1-C1 Function Selection
Sets the function for MFDO terminal P1-C1.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in through mode.
Term P2-C2 Function Selection
Sets the function for MFDO terminal P2-C2.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in through mode.
Watt Hour Output Unit Selection
Sets the unit for the output signal when H2-01 to H2-03 = 39 [MFDO Function Selection = Watt Hour Pulse Output].
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
Modbus Register 1 Address Select
Modbus Register 1 Bit Select
Modbus Register 2 Address Select
Modbus Register 2 Bit Select
Comparator 1 Monitor Selection
Comparator 1 Lower Limit
Comparator 1 Upper Limit
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
Sets the monitor number for comparator 1. Set the x-xx part of the Ux-xx [Monitor]. For example, set H2-20 = 102 to monitor U1-02 [Output Frequency].
Sets the lower limit detection level for comparator 1 when the full scale analog output for the monitor selected in H2-20 [Comparator 1 Monitor Selection] is the 100% value.
Sets the upper limit detection level for comparator 1 when the full scale analog output for the monitor selected in H2-20 [Comparator 1 Monitor Selection] is the 100% value.
Default
(Range)
E
(0 - 1FF)
0
(0 - 1FF)
2
(0 - 1FF)
0
(0 - 4)
0001
(0001 - 1FFF)
0000
(0000 - FFFF)
0001
(0001 - 1FFF)
0000
(0000 - FFFF)
102
(000 - 999)
0.0%
(0.0 - 300.0%)
0.0%
(0.0 - 300.0%)
Ref.
311
311
312
312
312
312
313
313
313
313
313
54 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
H2-23
(1543)
H2-24
(1544)
H2-25
(1545)
H2-26
(1546)
H2-27
(1547)
H2-28
(1548)
H2-29
(1549)
H2-30
(154A)
H2-31
(154B)
H2-32
(159A)
H2-33
(159B)
H2-34
(159C)
H2-35
(159D)
H2-36
(159E)
H2-37
(159F)
H2-40
(0B58)
H2-41
(0B59)
H2-42
(0B5A)
H2-60
(1B46)
Expert
H2-61
(1B47)
Expert
Name Description
Comparator 1 Hysteresis
Sets the hysteresis level for comparator 1 as a percentage of the full scale analog output for the monitor selected in H2-20 [Comparator 1 Monitor Selection].
Comparator 1 On-Delay Time
Comparator 1 Off-Delay Time
Comparator 2 Monitor Selection
Comparator 2 Lower Limit
Comparator 2 Upper Limit
Sets the on-delay time for comparator 1.
Sets the off-delay time for comparator 1.
Sets the monitor number for comparator 2. Set the x-xx part of the Ux-xx [Monitor]. For example, set H2-26 = 103 to monitor U1-03 [Output Current].
Sets the lower limit detection level for comparator 2 as a percentage of the full scale analog output for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
Sets the upper limit detection level for comparator 2 as a percentage of the full scale analog output for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
Comparator 2 Hysteresis
Sets the hysteresis level for comparator 2 as a percentage of the full scale analog output for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
Comparator 2 On-Delay Time
Comparator 2 Off-Delay Time
Sets the on-delay time for comparator 2.
Sets the off-delay time for comparator 2.
Comparator 1 Filter Time
Sets the time constant that is applied to the primary delay filter used for the analog output of the monitor selected with H2-20 [Comparator 1 Monitor Selection].
Comparator1 Protection Selection
Sets drive operation when it detects CP1 [Comparator1 Limit Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
Comparator 2 Filter Time
Sets the time constant that is applied to the primary delay filter used for the analog output of the monitor selected with H2-26 [Comparator 2 Monitor Selection].
Comparator2 Protection Selection
Sets drive operation when it detects CP2 [Comparator2 Limit Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
Comparator 1 Ineffective Time
Comparator 2 Ineffective Time
Mbus Reg 15E0h bit0 Output Func
Mbus Reg 15E0h bit1 Output Func
Mbus Reg 15E0h bit2 Output Func
Term MA,MB,MC Secondary Function
Term MA,MB,MC Logical Operation
Sets the length of time that CP1 [Comparator1 Limit Fault] is disabled.
Sets the length of time that CP2 [Comparator2 Limit Fault] is disabled.
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
Sets the second function for terminal MA/MB-MC. Outputs the logical calculation results of the terminals set to functions by H2-01 [Term MA,MB,MC Function Selection].
Sets the logical operation for the functions set in H2-01 [Term MA,MB,MC Function Selection] and H2-60 [Term MA,MB,MC Secondary Function].
Default
(Range)
0.0%
(0.0 - 10.0%)
0.0 s
(0.0 - 600.0 s)
0.0 s
(0.0 - 600.0 s)
103
(000 - 999)
0.0%
(0.0 - 300.0%)
0.0%
(0.0 - 300.0%)
0.0%
(0.0 - 10.0%)
0.0 s
(0.0 - 600.0 s)
0.0 s
(0.0 - 600.0 s)
0.0s
(0.0 - 10.0 s)
4
(0 - 4)
0.0s
(0.0 - 10.0 s)
4
(0 - 4)
0.0 s
(0.0 - 1000.0 s)
0.0 s
(0.0 - 1000.0 s)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - FF)
0
(0 - 8)
Ref.
313
314
314
314
314
314
314
315
315
315
315
315
316
316
316
316
316
317
317
317
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 55
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
H2-62
(1B48)
Expert
H2-63
(1B49)
Expert
H2-64
(1B4A)
Expert
H2-65
(1B4B)
Expert
H2-66
(1B4C)
Expert
H2-67
(1B4D)
Expert
H2-68
(1B4E)
Expert
Name Description
Term MA,MB,MC Minimum ON Time
Terminal P1 Secondary Function
Terminal P1 Logical Operation
Terminal P1 Minimum ON Time
Terminal P2 Secondary Function
Terminal P2 Logical Operation
Terminal P2 Minimum ON Time
Sets the minimum ON time that the drive uses to output the logical calculation results from terminal MA/MB-MC.
Sets the second function for terminal P1-C1. Outputs the logical calculation results of the terminals set to functions by H2-02 [Term P1 Function Selection].
Sets the logical operation for the functions set in H2-02 [Term P1 Function Selection] and H2-63 [Terminal P1 Secondary Function].
Sets the minimum ON time used to output the logical calculation results from terminal P1­C1.
Sets the second function for terminal P2-C2. Outputs the logical calculation results of the terminals assigned to functions by H2-03 [Term P2 Function Selection].
Sets the logical operation for the functions set in H2-03 [Term P2 Function Selection] and H2-66 [Terminal P2 Secondary Function].
Sets the minimum ON time used to output the logical calculation results from terminal P2­C2.
H2-xx: MFDO Setting Values
Default
(Range)
0.1 s
(0.0 - 25.0 s)
F
(0 - FF)
0
(0 - 8)
0.1 s
(0.0 - 25.0 s)
F
(0 - FF)
0
(0 - 8)
0.1 s
(0.0 - 25.0 s)
Ref.
317
317
317
317
318
318
318
Setting Value Function Description Ref.
0 During Run
318
The terminal activates when you input a Run command and when the drive is outputting voltage.
ON : Drive is running
OFF : Drive is stopping
1 Zero Speed
The terminal turns on when the output frequency drops below the value of E1-09 [Minimum Output Frequency] or b2- 01 [DC Injection/Zero SpeedThreshold].
318
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the reference.
A1-02 Setting Control Method Selection Parameter Used as the Reference
0 V/f E1-09
2 OLV b2-01
5 OLV/PM E1-09
6 AOLV/PM E1-09
8 EZOLV E1-09
ON : Output frequency < value of E1-09 or b2-01.
OFF : Output frequency ≥ value of E1-09 or b2-01.
2 Speed Agree 1
The terminal activates when the output frequency is in the range of the frequency reference ± L4-02 [Speed Agree Detection Width].
319
ON : The output frequency is in the range of frequency reference ± L4-02.
OFF : The output frequency does not align with the frequency reference although the drive is running.
3 User-Set Speed Agree 1
The terminal activates when the output frequency is in the range of L4-01 [Speed Agree Detection Level] ± L4-02 [Speed Agree Detection Width] and in the range of the frequency reference ± L4-02.
319
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the forward/reverse detection level.
ON : The output frequency is within the range as defined by the result of L4-01 ± L4-02and the range of frequency reference ± L4-02.
OFF : The output frequency is not in the range of L4-01 ± L4-02nor the range of frequency reference ± L4-02.
56 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
4 Frequency Detection 1
5 Frequency Detection 2
6 Drive ready
7 DC Bus Undervoltage
8 During Baseblock (N.O.)
9 Frequency Reference
from Keypad
A Run Command Source
B Torque Detection 1 (N.
O.)
C Frequency Reference
Loss
D Braking Resistor Fault
E Fault
F Not Used
10 Alarm
11 Fault Reset Command
Active
12 Timer Output
The terminal deactivates when the output frequency is higher than the value of L4-01 [Speed Agree Detection Level] + L4-02 [Speed Agree Detection Width]. After the terminal turns off, the terminal continues to remain off until the output frequency reaches the level set with L4-01.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the forward/reverse detection level.
ON : The output frequency is less than the value of L4-01 or does not exceed the value of L4-01 + L4-02.
OFF : The output frequency is higher than the value of L4-01 + L4-02.
The terminal activates when the output frequency is higher than the value of L4-01 [Speed Agree Detection Level]. After the terminal activates, the terminal stays activated until the output frequency is at the value of L4-01 - L4-02.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the forward/reverse detection level.
ON : The output frequency is higher than the value of L4-01. OFF : The output frequency is less than the value of L4-01 - L4-02,or it does not exceed the value of L4-01.
The terminal activates when the drive is ready and running.
The terminal activates when the DC bus voltage or control circuit power supply is less than the voltage set with L2-05 [Undervoltage Detection Lvl (Uv1)]. The terminal also turns on when there is a fault with the DC bus voltage.
ON : The DC bus voltage is less than the setting value of L2-05.
OFF : The DC bus voltage is more than the setting value of L2-05.
The terminal turns on during baseblock. When the drive is in baseblock, the drive output transistor stops switching and does not make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
Shows the selected frequency reference source.
ON : The keypad is the frequency reference source.
OFF : Parameter b1-01 or b1-15 [Frequency Reference Selection 1 or 2] is the frequency reference source.
Shows the selected Run command source.
ON : The keypad is the Run command source.
OFF : Parameter b1-02 or b1-16 [Run Command Selection 1 or 2] is the Run command source.
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque > L6-02 [Torque Detection Level 1], or < L6-02 for longer than the time set with L6-03 [Torque Detection Time 1].
The terminal activates when the drive detects a loss of frequency reference.
The terminal activates when the mounting-type braking resistor is overheating or when there is a braking transistor fault.
The terminal activates when the drive detects a fault.
Note:
The terminal will not activate for CPF00 and CPF01 [Control Circuit Error] faults.
Use this setting for unused terminals or to use terminals in through mode. Also use this setting as the PLC contact output via MEMOBUS/Modbus or the communication option. This signal does not function if signals from the PLC are not configured.
The terminal turns on when the drive detects a minor fault.
The terminal turns on when the drive receives the Reset command from the control circuit terminal, serial communications, or the communication option.
Use this setting when the drive uses the timer function as an output terminal.
320
320
321
321
321
321
322
322
322
322
322
322
322
323
323
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 57
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
13 Speed Agree 2
14 User-Set Speed Agree 2
15 Frequency Detection 3
16 Frequency Detection 4
17 Torque Detection 1 (N.C.)
18 Torque Detection 2 (N.
O.)
19 Torque Detection 2 (N.C.)
1A During reverse
1B During Baseblock (N.C.)
1C Motor 2 Selected
1E Executing Auto-Restart
1F Motor Overload Alarm
20 Drive Overheat Pre-
(oL1)
Alarm (oH)
The terminal activates when the output frequency is in the range of the frequency reference ± L4-04 [Speed Agree Detection Width(+/-)].
Note:
The detection function operates in the two motor rotation directions.
ON : The output frequency is in the range of frequency reference ± L4-04. OFF : The output frequency is not in the range of frequency reference ± L4-04.
The terminal activates when the output frequency is in the range of L4-03 [Speed Agree Detection Level(+/-)] ± L4-04 [Speed Agree Detection Width(+/-)] and in the range of the frequency reference ± L4-04.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is in the range of L4-03 ± L4-04and the range of frequency reference ± L4-04. OFF : The output frequency is not in the range of L4-03 ± L4-04nor the range of frequency reference ± L4-04.
The terminal deactivates when the output frequency is higher than the value of L4-03 [Speed Agree Detection Level (+/-)] + L4-04 [Speed Agree Detection Width(+/-)]”. After the terminal deactivates, the terminal stays deactivated until the output frequency is at the value of L4-03.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is less than the value of L4-03 or does not exceed the value of L4-03 + L4-04.
OFF : The output frequency is higher than the value of L4-03 + L4-04.
The terminal activates when the output frequency is higher than the value of L4-03 [Speed Agree Detection Level
(+/-)]. After the terminal activates, the terminal stays activated until the output frequency is at the value of L4-03 - L4-
04.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is higher than the value of L4-03. OFF : The output frequency is less than the value of L4-03 - L4-04,or it does not exceed the value of L4-03.
The terminal deactivates when the drive detects overtorque or undertorque.
OFF : The output current/torque is more than the torque value set with L6-02 [Torque Detection Level 1], or the level is less than the torque value set with L6-02 [Torque Detection Level 1] for longer than the time set with L6-03 [Torque Detection Time 1].
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque is more than the torque value set with L6-05 [Torque Detection Level 2], or the level is less than the torque value set with L6-05 [Torque Detection Level 2] for longer than the time set with L6-06 [Torque Detection Time 2].
The terminal deactivates when the drive detects overtorque or undertorque.
OFF : The output current/torque is more than the torque value set with L6-05 [Torque Detection Level 2], or the level is less than the torque value set with L6-05 [Torque Detection Level 2] for longer than the time set with L6-06 [Torque Detection Time 2].
The terminal activates when the motor operates in the reverse direction.
ON : The motor is operating in the reverse direction.
OFF : The motor is operating in the forward direction or the motor stopped.
The terminal deactivates during baseblock. When the drive is in baseblock, the drive output transistor stops switching and does not make DC bus voltage.
ON : The drive is not in baseblock.
OFF : During baseblock
The terminal activates when motor 2 is selected.
ON : Motor 2 Selection
OFF : Motor 1 Selection
The terminal activates when the Auto Restart function is trying to restart after a fault.
The terminal activates when the electronic thermal protection value of the motor overload protective function is a minimum of 90% of the detection level.
The terminal activates when the drive heatsink temperature is at the level set with L8-02 [Overheat Alarm Level].
323
323
324
324
325
325
325
325
326
326
326
326
326
58 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
21 Safe Torque OFF
22 Mechanical Weakening
Detection
2F Maintenance Notification
30 During Torque Limit
37 During Frequency Output
38 Drive Enabled
39 Watt Hour Pulse Output
3C LOCAL Control Selected
3D During Speed Search
3E PID Feedback Low
3F PID Feedback High
4A During KEB Ride-Thru
4B During Short Circuit
Braking
4C During Fast Stop
4D oH Pre-Alarm Time Limit
4E Braking Transistor Fault
4F Braking Resistor
61 Pole Position Detection
62 Modbus Reg 1 Status
(rr)
Overheat (rH)
Complete
Satisfied
The terminal activates (safety stop state) when the safety circuit and safety diagnosis circuit are operating correctly and when terminals H1-HC and H2-HC are OFF (Open).
ON : Safety stop state
OFF : Safety circuit fault or RUN/READY
The terminal activates when the drive detects mechanical weakening.
The terminal activates when drive components are at their estimated maintenance period.
Tells the user about the maintenance period for these items:
IGBT
Cooling fan
Capacitor
Soft charge bypass relay
The terminal activates when the torque reference is the torque limit set with L7 parameters or H3-02 or H3-10 [MFAI Function Selection].
The terminal activates when the drive outputs frequency.
ON : The drive outputs frequency.
OFF : The drive does not output frequency.
This terminal activates when the H1-xx = 6A [Drive Enable] terminal activates.
Outputs the pulse that shows the watt hours.
The terminal activates when the Run command source or frequency reference source is LOCAL.
ON : LOCAL
OFF : REMOTE
The terminal activates when the drive is doing speed search.
The terminal activates when the drive detects FbL [PID Feedback Loss].
The terminal activates when the drive detects FbH [Excessive PID Feedback].
The activates during KEB Ride-Thru.
The terminal activates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
The terminal activates when the fast stop is in operation.
The terminal activates when L8-03 = 4 [Overheat Pre-Alarm Selection = Operate at Reduced Speed (L8-19)] and oH [Heatsink Overheat] does not clear after the drive decreases the frequency for 10 cycles.
The terminal activates when the internal braking transistor overheats and the drive detects an rr [Dynamic Braking Transistor Fault] fault.
The terminal activates when the braking resistor overheats and the drive detects an rH [Braking Resistor Overheat] fault.
The terminal activates when drive receives a Run command and the drive detects the motor magnetic pole position of the PM motor.
The terminal activates when the bit specified by H2-08 [Modbus Register 1 Bit Select] for the MEMOBUS register address set with H2-07 [Modbus Register 1 Address Select] activates.
327
327
327
327
327
328
328
328
328
329
329
329
329
329
329
330
330
330
330
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 59
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
63 Modbus Reg 2 Status
66 Comparator1
67 Comparator2
69 External Power 24V
6A Data Logger Error
90 - 92 DWEZ Digital Output 1
100 - 192 Inverse output of 0 to 92
Satisfied
Supply
to 3
The terminal activates when the bit specified by H2-10 [Modbus Register 2 Bit Select] for the MEMOBUS register address set with H2-09 [Modbus Register 2 Address Select] activates.
The terminal activates if the monitor value set with H2-20 [Comparator 1 Monitor Selection] is in range of the values of H2-21 [Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit] for the time set in H2-24 [Comparator 1 On-Delay Time].
The terminal activates if the monitor value set with H2-26 [Comparator 2 Monitor Selection] is not in the range of the values of H2-27 [Comparator 2 Lower Limit] and H2-28 [Comparator 2 Upper Limit] for the time set in H2-30 [Comparator 2 On-Delay Time].
The terminal activates when there is an external 24V power supply between terminals PS-AC.
ON : An external 24V power supply supplies power.
OFF : An external 24V power supply does not supply power.
The terminal activates when the drive detects LoG [Com Error / Abnormal SD card].
Sets the DriveWorksEZ digital output. Refer to the DriveWorksEZ online manual for more information.
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which function to inversely output.
330
330
331
331
331
331
331

H3: Analog Inputs

No.
(Hex.)
H3-01
(0410)
H3-02
(0434)
H3-03
(0411)
RUN
H3-04
(0412)
RUN
H3-09
(0417)
H3-10
(0418)
H3-11
(0419)
RUN
H3-12
(041A)
RUN
H3-13
(041B)
Name Description
Terminal A1 Signal Level Select
Terminal A1 Function Selection
Terminal A1 Gain Setting
Terminal A1 Bias Setting
Terminal A2 Signal Level Select
Terminal A2 Function Selection
Terminal A2 Gain Setting
Terminal A2 Bias Setting
Analog Input FilterTime Constant
Sets the input signal level for MFAI terminal A1.
0 : 0 to 10V (Lower Limit at 0)
4 : -10 to +10V (Bipolar Reference)
Sets the function for MFAI terminal A1.
Sets the gain of the analog signal input to MFAI terminal A1.
Sets the bias of the analog signal input to MFAI terminal A1.
Sets the input signal level for MFAI terminal A2.
0 : 0-10V (LowLim=0)
2 : 4 to 20 mA
3 : 0 to 20 mA
4 : -10 to +10V (Bipolar Reference)
Sets the function for MFAI terminal A2.
Sets the gain of the analog signal input to MFAI terminal A2.
Sets the bias of the analog signal input to MFAI terminal A2.
Sets the time constant for primary delay filters on MFAI terminals.
Default
(Range)
0
(0, 4)
0
(0 - 32)
100.0%
(-999.9 - +999.9%)
0.0%
(-999.9 - +999.9%)
2
(0, 2 - 4)
0
(0 - 32)
100.0%
(-999.9 - +999.9%)
0.0%
(-999.9 - +999.9%)
0.03 s
(0.00 - 2.00 s)
Ref.
334
334
334
334
335
335
335
335
336
60 YASKAWA TOEPYAIGA5002A GA500 Programming
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
H3-14
(041C)
Name Description
Analog Input Terminal Enable Sel
Sets the enabled terminal or terminals when H1-xx = C [MFDI Function Select = Analog Terminal Enable Selection] is ON.
Default
(Range)
7
(1, 2, 7)
1 : Terminal A1 only
2 : Terminal A2 only
7 : Terminals A1 and A2
H3-16
(02F0)
H3-17
(02F1)
H3-40
(0B5C)
H3-41
(0B5F)
H3-42
(0B62)
H3-43
(117F)
Terminal A1 Offset
Terminal A2 Offset
Mbus Reg 15C1h Input Function
Mbus Reg 15C2h Input Function
Mbus Reg 15C3h Input Function
Mbus Reg Inputs FilterTime Const
Sets the offset level for analog signals input to terminal A1. Usually it is not necessary to change this setting.
Sets the offset level for analog signals input to terminal A2. Usually it is not necessary to change this setting.
Sets the MEMOBUS AI1 function.
Sets the MEMOBUS AI2 function.
Sets the MEMOBUS AI3 function.
Sets the time constant to apply a primary delay filter to the MEMOBUS analog input register values.
0
(-500 - +500)
0
(-500 - +500)
F
(4 - 2F)
F
(4 - 2F)
F
(4 - 2F)
0.00 s
(0.00 - 2.00 s)
H3-xx: MFAI Setting Values
Setting Value Function Description Ref.
0 Frequency Reference
1 Frequency Gain
2 Auxiliary Frequency
Reference 1
3 Auxiliary Frequency
Reference 2
4 Output Voltage Bias
5 Accel/Decel Time Gain
6 DC Injection Braking
Current
7 Torque Detection Level
8 Stall Prevent Level during
Run
The input value from the MFAI terminal set with this function becomes the master frequency reference.
The drive multiplies the analog frequency reference with the input value from the MFAI set with this function.
Sets Reference 2 through multi-step speed reference to enable the command reference (Auxiliary Frequency Reference
1) from the analog input terminal set here. This value is a percentage where the Maximum Output Frequency setting is a setting value of 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets Reference 3 through multi-step speed reference to enable the command reference (Auxiliary Frequency Reference
2) from the analog input terminal set here. This value is a percentage where the Maximum Output Frequency setting is a setting value of 100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Set this parameter to input a bias signal to amplify the output voltage.
Enters a signal to adjust the gain used for C1-01 to C1-08 [Acceleration/Deceleration Times 1 to 4] and C1-09 [Fast Stop Time] when the full scale analog signal (10 V or 20 mA) is 100%.
Enters a signal to adjust the current level used for DC Injection Braking when the drive rated output current is 100%.
Enters a signal to adjust the overtorque/undertorque detection level.
Note:
Use this function with L6-01 [Torque Detection Selection 1]. This parameter functions as an alternative to L6-02 [Torque Detection Level 1].
Enters a signal to adjust the stall prevention level during run if the drive rated current is 100%.
Ref.
336
336
336
336
337
337
337
337
337
338
338
338
338
339
339
339
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 61
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
Setting Value Function Description Ref.
9 Output Frequency Lower
Limit
B PID Feedback
C PID Setpoint
D Frequency Bias
E Motor Temperature (PTC
Input)
F Not Used
10 Forward Torque Limit
11 Reverse Torque Limit
12 Regenerative Torque
13 Torque Reference /
Limit
Torque Limit
14 Torque Compensation
15 General Torque Limit
16 Differential PID
Feedback
1F Not Used
30 DWEZ Analog Input 1
31 DWEZ Analog Input 2
Enters a signal to adjust the output frequency lower limit level as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Enter the PID feedback value as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Enters the PID setpoint as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Enters the bias value added to the frequency reference as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Uses the motor Positive Temperature Coefficient (PTC) thermistor to prevent heat damage to the motor as a percentage of the current value when the 10 V analog signal is input.
Use this setting for unused terminals or to use terminals in through mode.
Enters the forward torque limit if the motor rated torque is 100%.
Enters the load torque limit if the motor rated torque is 100%.
Enters the regenerative torque limit if the motor rated torque is 100%.
Enters the torque reference if the motor rated torque is 100%. This setting is the torque limit for speed control.
Enters the torque compensation value if the motor rated torque is 100%.
Enters the torque limit that is the same for all quadrants for forward, reverse, and regenerative operation if the motor rated torque is 100%.
Enters the PID differential feedback value if the full scale analog signal (10 V or 20 mA) is 100%.
Use this setting for unused terminals or to use terminals in through mode.
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
339
340
340
340
340
340
340
342
342
342
342
342
342
342
343
343
62 YASKAWA TOEPYAIGA5002A GA500 Programming

H4: Analog Outputs

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.10 H: Terminal Functions
No.
(Hex.)
H4-01
(041D)
H4-02
(041E)
RUN
H4-03
(041F)
RUN
H4-07
(0423)
Name Description
Terminal AM Analog Output Select
Terminal AM Analog Output Gain
Terminal AM Analog Output Bias
Terminal AM Signal Level Select
Sets the monitoring number to be output from the MFAO terminal AM.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H4-01 = 102 to monitor U1-02 [Output Frequency].
Sets the gain of the monitor signal that is sent from MFAO terminal AM.
Sets the analog signal output level from the terminal AM at 10 V or 20 mA as 100% when an output for monitoring items is 100%.
Sets the bias of the monitor signal that is sent from MFAO terminal AM.
When an output for monitoring items is 0%, this parameter sets the analog signal output level from the AM terminal at 10 V or 20 mA as 0%.
Sets the MFAO terminal AM output signal level.
Note:
Make sure that you set jumper S5 on the control circuit terminal board when you change these parameters.
0 : 0-10V
2 : 4 to 20 mA
H4-20
(0B53)
Analog Power Monitor 100% Level
Sets the level at 10 V when U1-08 [Output Power] is set for analog output.

H5: Modbus Communication

No.
(Hex.)
H5-01
(0425)
H5-02
(0426)
H5-03
(0427)
H5-04
(0428)
Name Description
Drive Node Address
Sets the communication slave address for drives.
Note:
Re-energize the drive or set H5-10 = 1 [Modbus Register 0025H Unit Sel= 1 V units] after you change the parameter setting.
Setting 0 will not let the drive respond to MEMOBUS/Modbus communications.
Communication Speed Selection
Sets the communications speed for MEMOBUS/Modbus communications.
Note:
Re-energize the drive or set H5-20 = 1 [Communication Parameters Reload = Reload Now] after you change the parameter setting.
0 : 1200 bps
1 : 2400 bps
2 : 4800 bps
3 : 9600 bps
4 : 19.2 kbps
5 : 38.4 kbps
6 : 57.6 kbps
7 : 76.8 kbps
8 : 115.2 kbps
Communication Parity Selection
Sets the communications parity used for MEMOBUS/Modbus communications.
Note:
Re-energize the drive or set H5-20 = 1 [Communication Parameters Reload = Reload Now] after you change the parameter setting.
0 : No parity
1 : Even parity
2 : Odd parity
Communication Error Stop Method
Sets the motor Stopping Method when the drive detects CE [MEMOBUS/Modbus Communication Err] issues.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
Default
(Range)
102
(000 - 999)
100.0%
(-999.9 - +999.9%)
0.0%
(-999.9 - +999.9%)
0
(0, 2)
0.00 kW
(0.00 - 650.00 kW)
Default
(Range)
1FH
(0 - FFH)
3
(0 - 8)
0
(0 - 2)
3
(0 - 3)
Ref.
344
344
344
345
345
Ref.
345
345
346
346
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 63
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
H5-05
(0429)
H5-06
(042A)
H5-09
(0435)
H5-10
(0436)
H5-11
(043C)
RUN
H5-12
(043D)
H5-17
(11A1)
Expert
H5-18
(11A2)
H5-20
(0B57)
H5-22
(11CF)
H5-25
(1589)
RUN
H5-26
(158A)
RUN
H5-27
(158B)
RUN
H5-28
(158C)
RUN
Name Description
Comm Fault Detection Selection
Sets the function that detects CE [Modbus Communication Error] issues during MEMOBUS/Modbus communications.
0 : Disabled
1 : Enabled
Drive Transmit Wait Time
Sets the time to wait to send a response message after the drive receives a command message from the master.
Note:
Restart the drive after changing the parameter setting.
CE Detection Time
Sets the detection time for CE [Modbus Communication Error] issues when communication stops.
Modbus Register 0025H Unit Sel
Sets the unit of measure used for the MEMOBUS/Modbus communications monitor register 0025H (output voltage reference monitor).
0 : 0.1 V units
1 : 1 V units
Comm ENTER Command Mode
Sets the function to make the Enter command necessary to change parameters through MEMOBUS/Modbus communications.
0 : ENTER Command Required
1 : ENTER Command Not Required
Run Command Method Selection
Sets the input method for the Run command when b1-02 = 2 [Run Command Selection 1 =
Memobus/Modbus Communications] or b1-16 = 2 [Run Command Selection 2 = Memobus/Modbus Communications].
0 : FWD/Stop, REV/Stop
1 : Run/Stop, FWD/REV
ENTER command response @CPU BUSY
Sets operation when the EEPROM write command is sent without EEPROM write available. Usually it is not necessary to change this setting.
0 : Ignore Command(No ROM/RAM Write)
1 : Write to RAM Only
Motor Speed Filter over Comms
Communication Parameters Reload
Sets the filter time constant used when monitoring motor speed during MEMOBUS/ Modbus communications or with a communication option.
Sets the function to immediately enable updated MEMOBUS/Modbus communications parameters.
0 : Reload at Next Power Cycle
1 : Reload Now
Speed Search from MODBUS
Enables the MEMOBUS/Modbus communication register Speed Search function (bit0 of 15DFH).
0 : Disabled
1 : Enabled
Function 5A Register 1 Selection
Function 5A Register 2 Selection
Function 5A Register 3 Selection
Function 5A Register 4 Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when responding to the master device.
Returns the contents of the specified MEMOBUS/Modbus communications register when responding to the master device.
Returns the contents of the specified MEMOBUS/Modbus communications register when responding to the master device.
Returns the contents of the specified MEMOBUS/Modbus communications register when responding to the master device.
Default
(Range)
1
(0, 1)
5 ms
(0 - 65 ms)
2.0 s
(0.0 - 25.0 s)
0
(0, 1)
1
(0, 1)
0
(0, 1)
0
(0, 1)
0 ms
(0 - 100 ms)
0
(0, 1)
0
(0, 1)
0044H (U1-05)
(0000H - FFFFH)
0045H (U1-06)
(0000H - FFFFH)
0042H (U1-03)
(0000H - FFFFH)
0049H (U1-10)
(0000H - FFFFH)
Ref.
346
347
347
347
347
347
348
348
348
348
349
349
349
349
64 YASKAWA TOEPYAIGA5002A GA500 Programming

H6: Pulse Train Input/Output

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.10 H: Terminal Functions
No.
(Hex.)
H6-01
(042C)
H6-02
(042D)
RUN
H6-03
(042E)
RUN
H6-04
(042F)
RUN
H6-05
(0430)
RUN
H6-06
(0431)
RUN
H6-07
(0432)
RUN
H6-08
(043F)
Name Description
Terminal RP Pulse Train Function
Sets the function for pulse train input terminal RP.
0 : Frequency Reference
1 : PID Feedback Value
2 : PID Setpoint
3 : Speed Feedback (V/F Control)
Terminal RP Frequency Scaling
Terminal RP Function Gain
Terminal RP Function Bias
Sets the frequency of the pulse train input signal used when the item selected with H6-01 [Terminal RP Pulse Train Function] is input at 100%.
Sets the gain used when the function in H6-01 [Terminal RP Pulse Train Function] is input to terminal RP.
Sets the bias used when the function in H6-01 [Terminal RP Pulse Train Function] is input to terminal RP. Sets a value at the time when the pulse train is 0 Hz.
Terminal RP Filter Time
Sets the time constant for the pulse train input primary delay filters.
Terminal MP Monitor Selection
Terminal MP Frequency Scaling
Terminal RP Minimum Frequency
Sets a function for pulse train monitor output terminal MP. Sets the x-xxpart of the Ux-xx monitor.
Sets the frequency of the pulse train output signal used when the monitor set with H6-06 [Terminal MP Monitor Selection] is 100%.
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
Default
(Range)
0
(0 - 3)
1440 Hz
(100 - 32000 Hz)
100.0%
(0.0 - 1000.0%)
0.0%
(-100.0 - 100.0%)
0.10 s
(0.00 - 2.00 s)
102
(000, 031, 101, 102, 105, 116, 501, 502, 801 - 809, 821 - 825, 831 - 839, 851
- 855)
1440 Hz
(0 - 32000 Hz)
0.5 Hz
(0.1 - 1000.0 Hz)
Ref.
349
351
351
351
351
351
352
352

H7: Virtual MFIO selection

No.
(Hex.)
H7-00
(116F)
Expert
H7-01
(1185)
Expert
H7-02
(1186)
Expert
H7-03
(1187)
Expert
H7-04
(1188)
Expert
Name Description
Virtual MFIO selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate the virtual I/O function.
0 : Disabled
1 : Enabled
Virtual Multi-Function Input 1
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output 1].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
Virtual Multi-Function Input 2
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output 2].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
Virtual Multi-Function Input 3
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output 3].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
Virtual Multi-Function Input 4
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output 4].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
Default
(Range)
0
(0, 1)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
Ref.
353
353
353
354
354
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 65
1.10 H: Terminal Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
H7-10
(11A4)
Expert
H7-11
(11A5)
Expert
H7-12
(11A6)
Expert
H7-13
(11A7)
Expert
H7-14
(11A8)
Expert
H7-15
(11A9)
Expert
H7-16
(11AA)
Expert
H7-17
(11AB)
Expert
H7-30
(1177)
Expert
H7-31
(1178)
RUN
Expert
H7-32
(1179)
RUN
Expert
H7-40
(1163)
H7-41
(1164)
H7-42
(1165)
Name Description
Virtual Multi-Function Output 1
Virtual Output 1 Delay Time
Virtual Multi-Function Output 2
Virtual Output 2 Delay Time
Virtual Multi-Function Output 3
Virtual Output 3 Delay Time
Virtual Multi-Function Output 4
Virtual Output 4 Delay Time
Virtual Analog Input Selection
Virtual Analog Input Gain
Sets the function for virtual digital output 1.
Sets the minimum ON time for virtual digital output 1.
Sets the function for virtual digital output 2.
Sets the minimum ON time for virtual digital output 2.
Sets the function for virtual digital output 3.
Sets the minimum ON time for virtual digital output 3.
Sets the function for virtual digital output 4.
Sets the minimum ON time for virtual digital output 4.
Sets the virtual analog input function.
Sets the virtual analog input gain.
Virtual Analog Input Bias
Sets the virtual analog input bias.
Virtual Analog Out Signal Select
Sets the signal level of the virtual analog output.
0 : 0 to 100% (Absolute Value)
1 : -100 to 100%
2 : 0 to 100% (Lower Limit at 0)
Virtual Analog Output Function
Virtual Analog Output FilterTime
Sets the monitor to be output from the virtual analog output.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H7-41 = 102 to monitor U1-02 [Output Frequency].
Sets the time constant for a primary filter of the virtual analog output.
Default
(Range)
F
(0 - 1A7)
0.1 s
(0.0 - 25.0 s)
F
(0 - 1A7)
0.1 s
(0.0 - 25.0 s)
F
(0 - 1A7)
0.1 s
(0.0 - 25.0 s)
F
(0 - 1A7)
0.1 s
(0.0 - 25.0 s)
F
(0 - 32)
100.0%
(-999.9 - 999.9%)
0.0%
(-999.9 - 999.9%)
0
(0 - 2)
102
(0 - 999)
0.00 s
(0.00 - 2.00 s)
Ref.
354
354
354
354
354
355
355
355
355
355
355
355
356
356
66 YASKAWA TOEPYAIGA5002A GA500 Programming
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

L1: Motor Protection

1.11 L: Protection Functions

No.
(Hex.)
L1-01
(0480)
L1-02
(0481)
L1-03
(0482)
L1-04
(0483)
L1-05
(0484)
L1-08
(1103)
L1-09
(1104)
L1-13
(046D)
L1-22
(0768)
RUN
L1-23
(0769)
RUN
Name Description
Motor Overload (oL1) Protection
Sets the motor overload protection with electronic thermal protectors.
0 : No
1 : Variable Torque
2 : Constant Torque 10:1 Speed Range
3 : Constant Torque 100:1 SpeedRange
4 : PM Variable Torque
5 : PM Constant Torque
6 : Variable Torque (50Hz)
Note:
When only one motor is connected to a drive, set L1-01 = 1 to 6 [Enabled]. External thermal relays are not necessary in these conditions.
Motor Overload Protection Time
Motor Thermistor oH Alarm Select
Sets the operation time for the electronic thermal protector of the drive to prevent damage to the motor. Usually it is not necessary to change this setting.
Sets drive operation when the PTC input signal entered into the drive is at the oH3 [Motor Overheat Alarm] detection level.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop
3 : Alarm Only
Motor Thermistor oH Fault Select
Sets the drive operation when the PTC input signal to the drive is at the oH4 [Motor Overheat Fault (PTC Input)] detection level.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop
Motor Thermistor Filter Time
Sets the primary delay time constant for the PTC input signal entered to the drive. This parameter prevents accidental motor overheat faults.
oL1 Current Level
Sets the reference current for the motor 1 thermal overload detection. When the current level > 0.0 A, you cannot set this value < 10% of drive rated current.
oL1 Current Level for Motor 2
Motor Overload Memory Selection
Sets the reference current for the motor 2 thermal overload detection. When the current level > 0.0 A, you cannot set this value < 10% of drive rated current.
Sets the function that keeps the current electronic thermal protector value when the drive stops receiving power.
0 : Disabled
1 : Enabled
Leakage Current Filter Time1
Sets the leakage current detection reduction filter time constant during constant speed run.
Note:
You can set this parameter when C6-02 = B [Carrier Frequency Selection = Leakage Current Detection Reduction Rate PWM].
Leakage Current Filter Time2
Sets the leakage current detection reduction filter time constant during acceleration/ deceleration.
Note:
You can set this parameter when C6-02 = B [Carrier Frequency Selection = Leakage Current Detection Reduction Rate PWM].
When the setting value increases, the current monitor also starts up slowly. Examine the relevant sequence for problems.
Default
(Range)
Determined by A1-02
(0 - 6)
1.0 min
(0.1 - 5.0 min)
3
(0 - 3)
1
(0 - 2)
0.20 s
(0.00 - 10.00 s)
0.0 A
(0.0 A or 10% to 150% of
the drive rated current)
0.0 A
(0.0 A or 10 to150% of the drive rated current)
1
(0, 1)
Determined by C6-02
(0.0 - 60.0 s)
Determined by C6-02
(0.0 - 60.0 s)
Ref.
358
361
362
362
362
362
363
363
363
363
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 67
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

L2: Power Loss Ride Through

No.
(Hex.)
L2-01
(0485)
L2-02
(0486)
L2-03
(0487)
L2-04
(0488)
L2-05
(0489)
L2-06
(048A)
Expert
L2-07
(048B)
Expert
L2-08
(048C)
Expert
L2-09
(048D)
Expert
L2-10
(048E)
Expert
L2-11
(0461)
Expert
L2-29
(0475)
Expert
Name Description
Power Loss Ride Through Select
Sets the drive operation after a momentary power loss.
0 : Disabled
1 : Enabled for L2-02 Time
2 : Enabled while CPU Power Active
3 : Kinetic Energy Backup: L2-02
4 : Kinetic Energy Backup: CPU Power
5 : Kinetic Energy Backup: DecelStop
Power Loss Ride Through Time
Minimum Baseblock Time
Powerloss V/f Recovery Ramp Time
Undervoltage Detection Lvl (Uv1)
Sets the maximum time that the drive will wait until trying to restart after power loss.
Sets the minimum time to continue the drive output block (baseblock) after a baseblock.
Sets the time for the drive output voltage to go back to correct voltage after completing speed searches.
Sets the voltage at which a Uv1 [DC Bus Undervoltage] fault is triggered or at which the KEB function is activated. Usually it is not necessary to change this setting.
NOTICE: Damage to Equipment. When you set this parameter to a value lower than the default, you must install an AC reactor on the input side of the power supply. If you do not install an AC reactor, it will cause damage to the drive circuitry.
Kinetic Energy Backup Decel Time
Kinetic Energy Backup Accel Time
Frequency Gain at KEB Start
KEB Minimum Frequency Level
Minimum KEB Time
KEB DC Bus Voltage Setpoint
Kinetic Energy Backup Method
Sets the deceleration time during KEB operation used to decrease the maximum output frequency to 0.
Note:
When L2-29 = 1, 2, or 3 [Kinetic Energy Backup Method = Single Drive KEB Ride­Thru 2, System KEB Ride-Thru 1, or System KEB Ride-Thru 2] and you do KEB Auto-
Tuning, the drive will automatically set this value.
Sets the acceleration time to return the frequency to the frequency reference before a power loss after canceling KEB operation.
Sets the quantity of output frequency reduction used when KEB operation starts as a percentage of the motor rated slip before starting KEB operation.
Sets the quantity of output frequency reduction used as a percentage of E2-02 [Motor Rated Slip] when KEB operation starts.
Sets the minimum length of time to operate the KEB after the drive detects a momentary power loss.
Sets the target value that controls the DC bus voltage to a constant level in Single Drive KEB Ride-Thru 2. Sets the DC bus voltage level that completes the KEB operation for all other KEB methods.
Sets the KEB function operation mode.
0 : Single Drive KEB Ride-Thru 1
1 : Single Drive KEB Ride-Thru 2
2 : System KEB Ride-Thru 1
3 : System KEB Ride-Thru 2
Default
(Range)
0
(0 - 5)
Determined by o2-04,
C6-01
(0.0 - 25.5 s)
Determined by o2-04,
C6-01
(0.1 - 5.0 s)
Determined by o2-04,
C6-01
(0.0 - 5.0 s)
Determined by o2-04 and
E1-01
(200 V Class: 150 - 210
V, 400 V Class: 300 - 420
V)
0.0 s
(0.0 - 6000.0 s)
0.0 s
(0.0 - 6000.0 s)
100%
(0 - 300%)
20%
(0 - 100%)
50 ms
(0 - 25500 ms)
Determined by E1-01
(Determined by E1-01)
0
(0 - 3)
Ref.
369
370
370
370
371
371
371
372
372
372
373
373
68 YASKAWA TOEPYAIGA5002A GA500 Programming
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L2-30
(045E)
Name Description
KEB Zero Speed Operation
Expert
L2-31
(045D)
KEB Start Voltage Offset Level
Expert

L3: Stall Prevention

No.
(Hex.)
L3-01
(048F)
L3-02
(0490)
L3-03
(0491)
L3-04
(0492)
L3-05
(0493)
Name Description
Stall Prevention during Accel
Stall Prevent Level during Accel
Stall Prevent Limit during Accel
Stall Prevention during Decel
Stall Prevention during RUN
Sets the operation when the output frequency decreases below the zero level (DC braking injection starting frequency) during KEB deceleration when L2-01 = 3 to 5 [Power Loss
Ride Through Select = Kinetic Energy Backup: L2-02, Kinetic Energy Backup: CPU Power, or Kinetic Energy Backup: DecelStop].
0 : Baseblock
1 : DC/SC Braking
Sets the KEB start voltage offset.
Sets the method of the Stall Prevention During Acceleration.
0 : Disabled
1 : Enabled
2 : Intelligent (Ignore Decel Ramp)
3 : Current Limit Acceleration
Sets the output current level at which the Stall Prevention function operates during acceleration where the drive rated output current is 100%.
Note:
The upper limit to the setting range changes when the setting for C6-01 [Normal / Heavy Duty Selection] changes.
150% when C6-01 = 0 [Heavy Duty Rating]
120% when C6-01 = 1 [Normal Duty Rating]
Sets the lower limit for the stall prevention level used in the constant output range as a percentage of the drive rated output current.
Sets the method that the drive will use to prevent overvoltage faults when decelerating.
Note:
1. To connect a dynamic braking option (braking resistor or braking resistor unit) to
the drive, set this parameter to 0 or 3. Parameter settings 1, 2, 4, 5, and 7 will enable Stall Prevention function during deceleration, and the dynamic braking option will not function.
2. The setting range changes when the A1-02 [Control Method Selection] value
changes:
When A1-02 = 5 [OLV/PM], the setting range is 0 to 2.
When A1-02 = 6 or 8 [AOLV/PM or EZOLV], the setting range is 0 or 1.
0 : No
1 : General Purpose
2 : Intelligent (Ignore Decel Ramp)
3 : General Purpose w/ DB resistor
4 : Overexcitation/High Flux
5 : Overexcitation/High Flux 2
7 : Overexcitation/High Flux 3
Sets the function to enable and disable Stall Prevention During Run.
Note:
An output frequency less than 6 Hz disables Stall Prevention during Run. The setting values of L3-05 and L3-06 [Stall Prevent Level during Run] do not have an effect.
The setting range changes when the A1-02 [Control Method Selection] value changes:
A1-02 = 0, 5[V/f, OLV/PM] : 0 to 2A1-02 =8[EZOLV] : 0, 3
0 : No
1 : Deceleration Time 1 (C1-02)
2 : Deceleration Time 2 (C1-04)
3 : Intelligent (Ignore Decel Ramp)
Default
(Range)
0
(0, 1)
Determined by A1-02
(200 V Class: 0 - 100
V,400 V Class: 0 - 200 V)
Default
(Range)
1
(0 - 3)
Determined by C6-01
(0 - 150%)
50%
(0 - 100%)
1
(Determined by A1-02)
2
(0 - Determined by A1-
02)
Ref.
373
374
Ref.
374
376
376
377
379
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 69
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L3-06
(0494)
L3-11
(04C7)
L3-17
(0462)
L3-20
(0465)
Expert
L3-21
(0466)
Expert
L3-22
(04F9)
L3-23
(04FD)
L3-24
(046E)
Expert
L3-25
(046F)
Expert
L3-26
(0455)
Expert
L3-27
(0456)
L3-34
(016F)
Expert
L3-35
(0747)
Expert
L3-36
(11D0)
L3-37
(11D1)
Expert
L3-38
(11D2)
Expert
Name Description
Stall Prevent Level during Run
Sets the output current level at which the Stall Prevention function is enabled during run when the drive rated output current is 100%.
Note:
This parameter is applicable when L3-05 = 1, 2 [Stall Prevention during RUN =
Deceleration Time 1 (C1-02), Deceleration Time 2 (C1-04)].
The upper limit to the setting range changes when the setting for C6-01 [Normal /
Heavy Duty Selection] changes.
150% when C6-01 = 0 [Heavy Duty Rating]120% when C6-01 = 1 [Normal Duty Rating]
Overvoltage Suppression Select
Sets the overvoltage suppression function.
0 : Disabled
1 : Enabled
DC Bus Regulation Level
Sets the target value for the DC bus voltage when the overvoltage suppression function and the Decel Stall Prevention function (Intelligent Stall Prevention) are active.
DC Bus Voltage Adjustment Gain
OVSuppression Accel/ Decel P Gain
PM Stall Prevention Decel Time
Stall P Reduction at Constant HP
Sets the proportional gain used to control the DC bus voltage.
Sets the proportional gain to calculate acceleration and deceleration rates.
Sets the momentary deceleration time that the drive will use when it tries to accelerate a PM motor and detected motor stalls. This function is applicable when L3-01 = 1 [Stall Prevent Select duringAccel = General Purpose].
Sets the function to automatically decrease the Stall Prevention Level during Run for constant output ranges.
0 : Use L3-06 for Entire Speed Range
1 : Automatic Reduction @ CHP Region
Motor Accel Time @ Rated Torque
Sets the motor acceleration time to reach the maximum frequency at the motor rated torque for stopped single-drive motors.
Load Inertia Ratio
Sets the ratio between motor inertia and machine inertia.
Additional DC Bus Capacitors
Stall Prevention Detection Time
Sets the capacity for external main circuit capacitors. Usually it is not necessary to change this setting. Sets this parameter when you use the KEB Ride-Thru function.
Sets a delay time between reaching the Stall Prevention level and starting the Stall Prevention function.
Torque Limit Delay Time
Sets the filter time constant that returns the torque limit to its initial value when KEB operation operates in Single Drive KEB Ride-Thru mode.
Speed Agree Width for Auto Decel
Current Suppression Gain@Accel
Current Limit P Gain @ Accel
Current Limit I Time @ Accel
Sets the width for speed agreement when L3-04 = 2 [Decel Stall Prevention Selection = Automatic Decel Reduction]. Usually it is not necessary to change this setting.
Sets the gain to suppress current and motor speed hunting during operation when L3-01 = 3 [Stall Prevention during Accel = Current Limit Method]. Usually it is not necessary to change this setting.
Suppresses current hunting during acceleration. Usually it is not necessary to change this setting.
Suppresses current hunting and overshooting that occurs when the drive stalls during acceleration. Usually it is not necessary to change this setting.
Default
(Range)
Determined by C6-01
(5 - 150%)
0
(0, 1)
200 V Class: 375 V, 400
V: 750 V
(200 V Class: 150 to 400
V, 400 V Class: 300 to
800 V)
Determined by A1-02
(0.00 - 5.00)
Determined by A1-02
(0.10 - 10.00)
0.0 s
(0.0 - 6000.0 s)
0
(0, 1)
Determined by o2-04,
C6-01, E2-11, and E5-01
(0.001 - 10.000 s)
1.0
(0.1 - 1000.0)
0 μF
(0 to 65000 μF)
60 ms
(0 - 5000 ms)
Determined by A1-02
(0.000 - 1.000 s)
0.00 Hz
(0.00 - 1.00 Hz)
Determined by A1-02
(0.0 - 100.0)
5 ms
(0 - 100 ms)
10.0
(0.0 - 100.0)
Ref.
379
380
380
380
381
381
381
381
382
382
382
382
383
383
383
383
70 YASKAWA TOEPYAIGA5002A GA500 Programming
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L3-39
(11D3)
L3-40
(11D4)
Name Description
Current Limit Filter Time @Accel
Current Limit S-Curve @ Acc/Dec
Sets the time constant to adjust the acceleration rate when L3-01 = 3 [Stall Prevention during Accel = Current Limit Method]. Usually it is not necessary to change this setting.
Sets the function to enable and disable the best S-curve characteristic used for current­limited acceleration.
0 : Disabled
1 : Enabled

L4: Speed Detection

No.
(Hex.)
L4-01
(0499)
L4-02
(049A)
L4-03
(049B)
L4-04
(049C)
L4-05
(049D)
L4-06
(04C2)
L4-07
(0470)
L4-08
(047F)
Name Description
Speed Agree Detection Level
Speed Agree Detection Width
Speed Agree Detection Level(+/-)
Speed Agree Detection Width(+/-)
Fref Loss Detection Selection
Sets the level to detect speed agree or motor speed.
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency Detection 1, Frequency Detection 2].
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency Detection 1, Frequency Detection 2].
Sets the level to detect speed agree or motor speed.
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = 13, 14, 15, 16
[MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2, Frequency Detection 3, Frequency Detection 4].
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 13, 14, 15, 16
[MFDO Function Selection = Speed Agree 2, User-set Speed Agree 2, Frequency Detection 3, Frequency Detection 4].
Sets the operation when the drive detects a loss of frequency reference.
0 : Stop
1 : Run at (L4-06 x Last Reference)
Frequency Reference @Loss of Ref
Speed Agree Detection Selection
Sets the frequency reference as a percentage to continue drive operation after it detects a frequency reference loss. The value is a percentage of the frequency reference before the drive detected the loss.
Sets the condition that activates speed detection.
0 : No Detection during Baseblock
1 : Detection Always Enabled
Speed Agree Source Selection
Sets the drive to use the soft starter output frequency or the motor speed (estimation value) for speed detection.
0 : Softstarter Output (Reference)
1 : Motor Speed (Actual Speed)

L5: Fault Restart

Default
(Range)
100.0 ms
(1.0 - 1000.0 ms)
0
(0, 1)
Default
(Range)
Determined by A1-02
(Determined by A1-02)
Determined by A1-02
(Determined by A1-02)
Determined by A1-02
(Determined by A1-02)
Determined by A1-02
(Determined by A1-02)
0
(0, 1)
80.0%
(0.0 - 100.0%)
0
(0, 1)
0
(0, 1)
Ref.
383
383
Ref.
384
384
384
384
384
385
385
385
Parameter List
1
No.
(Hex.)
L5-01
(049E)
L5-02
(049F)
Name Description
Number of Auto-Restart Attempts
Fault Contact at Restart Select
Sets the number of times that the drive will try to restart.
Sets the function that sends signals to the MFDO terminal set for Fault [H2-xx = E] while the drive is automatically restarting.
Default
(Range)
0
(0 - 10 times)
0
(0, 1)
Ref.
387
387
0 : Active Only when Not Restarting
1 : Always Active
YASKAWA TOEPYAIGA5002A GA500 Programming 71
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L5-04
(046C)
L5-05
(0467)
L5-07
(0B2A)
L5-08
(0B2B)
Name Description
Interval Method Restart Time
Sets the time interval between each Auto Restart attempt. This function is enabled when L5-05 = 1 [Auto Restart Operation Selection = Use L5-04 Time].
Auto-Restart Method
Sets the count method for the Auto Restart operation.
0 : Continuous/Immediate Attempts
1 : Interval/Attempt after L5-04 sec
Fault Reset Enable Select Grp1
Use these 4 digits to set the Auto Restart function for oL1 to oL4. From left to right, the digits set oL1, oL2, oL3, and oL4, in order.
0000 : Disabled
0001 : Enabled (—/—/—/oL4)
0010 : Enabled (—/—/oL3/—)
0011 : Enabled (—/—/oL3/oL4)
0100 : Enabled (—/oL2/—/—)
0101 : Enabled (—/oL2/—/oL4)
0110 : Enabled (—/oL2/oL3/—)
0111 : Enabled (—/oL2/oL3/oL4)
1000 : Enabled (oL1/—/—/—)
1001 : Enabled (oL1/—/—/oL4)
1010 : Enabled (oL1/—/oL3/—)
1011 : Enabled (oL1/—/oL3/oL4)
1100 : Enabled (oL1/oL2/—/—)
1101 : Enabled (oL1/oL2/—/oL4)
1110 : Enabled (oL1/oL2/oL3/—)
1111 : Enabled (oL1/oL2/oL3/oL4)
Fault Reset Enable Select Grp2
Use these 4 digits to set the Auto Restart function for Uv1, ov, oH1, and GF. From left to right, the digits set Uv1, ov, oH1, and GF, in order.
0000 : Disabled
0001 : Enabled (—/–/—/GF)
0010 : Enabled (—/–/oH1/–)
0011 : Enabled (—/–/oH1/GF)
0100 : Enabled (—/ov/—/–)
0101 : Enabled (—/ov/—/GF)
0110 : Enabled (—/ov/oH1/–)
0111 : Enabled (—/ov/oH1/GF)
1000 : Enabled (Uv1/–/—/–)
1001 : Enabled (Uv1/–/—/GF)
1010 : Enabled (Uv1/–/oH1/–)
1011 : Enabled (Uv1/–/oH1/GF)
1100 : Enabled (Uv1/ov/—/–)
1101 : Enabled (Uv1/ov/—/GF)
1110 : Enabled (Uv1/ov/oH1/–)
1111 : Enabled (Uv1/ov/oH1/GF)
Default
(Range)
10.0 s
(0.5 - 600.0 s)
0
(0, 1)
1111
(0000 - 1111)
1111
(0000 - 1111)
Ref.
387
387
387
388
72 YASKAWA TOEPYAIGA5002A GA500 Programming

L6: Torque Detection

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.11 L: Protection Functions
No.
(Hex.)
L6-01
(04A1)
L6-02
(04A2)
L6-03
(04A3)
L6-04
(04A4)
L6-05
(04A5)
L6-06
(04A6)
L6-07
(04E5)
L6-08
(0468)
L6-09
(0469)
Name Description
Torque Detection Selection 1
Sets the speed range that detects overtorque and undertorque and the operation of drives (operation status) after detection.
0 : Disabled
1 : oL @ Speed Agree - Alarm only
2 : oL @ RUN - Alarm only
3 : oL @ Speed Agree - Fault
4 : oL @ RUN - Fault
5 : UL @ Speed Agree - Alarm only
6 : UL @ RUN - Alarm only
7 : UL @ Speed Agree - Fault
8 : UL @ RUN - Fault
Torque Detection Level 1
Sets the detection level for Overtorque/Undertorque Detection 1. In V/f control, drive rated output current = 100% value. In vector control, motor rated torque = 100% value.
Torque Detection Time 1
Sets the detection time for Overtorque/Undertorque Detection 1.
Torque Detection Selection 2
Sets the speed range that detects overtorque and undertorque and the operation of drives (operation status) after detection.
0 : Disabled
1 : oL @ Speed Agree - Alarm only
2 : oL @ RUN - Alarm only
3 : oL @ Speed Agree - Fault
4 : oL @ RUN - Fault
5 : UL @ Speed Agree - Alarm only
6 : UL @ RUN - Alarm only
7 : UL @ Speed Agree - Fault
8 : UL @ RUN - Fault
Torque Detection Level 2
Sets the detection level for Overtorque/Undertorque Detection 2. In V/f control, drive rated output current = 100% value. In vector control, motor rated torque = 100% value.
Torque Detection Time 2
Sets the detection time for Overtorque/Undertorque Detection 2.
Torque Detection Filter Time
Mechanical Fatigue Detect Select
Sets the time constant for a primary filter to the torque reference or to the output current used to detect overtorque/undertorque.
Sets the speed where the drive detects mechanical deterioration and how the drive operates (operation status) after detection.
0 : Disabled
1 : oL5 @ Speed > L6-09 - Alarm
2 : oL5 @ |Speed| > L6-09 - Alarm
3 : oL5 @ Speed > L6-09 - Fault
4 : oL5 @ |Speed| > L6-09 - Fault
5 : UL5 @ Speed < L6-09 - Alarm
6 : UL5 @ |Speed| < L6-09 - Alarm
7 : UL5 @ Speed < L6-09 - Fault
8 : UL5 @ |Speed| < L6-09 - Fault
Mech Fatigue Detect Speed Level
Sets the speed level where the drive will operate the mechanical deterioration detection function, as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
0
(0 - 8)
150%
(0 - 300%)
0.1 s
(0.0 - 10.0 s)
0
(0 - 8)
150%
(0 - 300%)
0.1 s
(0.0 - 10.0 s)
0 ms
(0 - 1000 ms)
0
(0 - 8)
110.0%
(-110.0 - 110.0%)
Ref.
391
392
392
392
393
393
393
393
Parameter List
1
394
YASKAWA TOEPYAIGA5002A GA500 Programming 73
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L6-10
(046A)
L6-11
(046B)
Name Description
Mech Fatigue Detect Delay Time
Mech Fatigue Hold Off Time

L7: Torque Limit

No.
(Hex.)
L7-01
(04A7)
RUN
L7-02
(04A8)
RUN
L7-03
(04A9)
RUN
L7-04
(04AA)
RUN
L7-06
(04AC)
L7-07
(04C9)
L7-16
(044D)
Name Description
Forward Torque Limit
Reverse Torque Limit
Forward Regenerative Trq Limit
Reverse Regenerative Trq Limit
Torque Limit Integral Time
Torque Limit during Accel/Decel
Torque Limit Process at Start
Sets the time for mechanical deterioration detection.
Sets the time that the drive will start mechanical deterioration detection triggered by the cumulative operation time of the drive.
Sets the torque limit value for forward motoring as a percentage, where motor rated torque is the 100% value.
Sets the torque limit value for reversed motoring as a percentage, where motor rated torque is the 100% value.
Sets the torque limit value for forward regenerative conditions as a percentage of the motor rated torque.
Sets the torque limit value for reversed regenerative conditions as a percentage of the motor rated torque.
Sets the integral time constant for the torque limit function.
Sets the torque limit function during acceleration and deceleration.
0 : Proportional only
1 : Proportional & Integral control
Assigns a time filter to allow the torque limit to build at start.
0 : Disabled
1 : Enabled
Default
(Range)
0.1 s
(0.0 - 10.0 s)
0 h
(0 - 65535 h)
Default
(Range)
200%
(0 - 300%)
200%
(0 - 300%)
200%
(0 - 300%)
200%
(0 - 300%)
200 ms
(5 - 10000 ms)
0
(0, 1)
1
(0, 1)
Ref.
394
394
Ref.
395
395
396
396
396
396
397

L8: Drive Protection

No.
(Hex.)
L8-01
(04AD)
L8-02
(04AE)
L8-03
(04AF)
L8-05
(04B1)
Name Description
3% ERF DB Resistor Protection
Sets the function to enable braking resistor protection with a Yaskawa ERF series braking resistor (3% ED) installed on the heatsink.
0 : No
1 : Yes
Overheat Alarm Level
Sets the oH detection level in temperature.
Overheat Pre-Alarm Selection
Sets the operation of drives when an oH alarm is detected.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Operate at Reduced Speed (L8-19)
Input Phase Loss Protection Sel
Sets the function to enable and disable input phase loss detection.
0 : Disable
1 : Enabled
Default
(Range)
0
(0, 1)
Determined by o2-04,
C6-01
(50 - 150 °C)
3
(0 - 4)
1
(0, 1)
Ref.
397
397
397
398
74 YASKAWA TOEPYAIGA5002A GA500 Programming
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L8-07
(04B3)
L8-09
(04B5)
L8-10
(04B6)
L8-11
(04B7)
L8-12
(04B8)
L8-15
(04BB)
L8-18
(04BE)
L8-19
(04BF)
L8-27
(04DD)
L8-29
(04DF)
L8-31
(04E1)
Name Description
Output Phase Loss Protection Sel
Sets the function to enable and disable output phase loss detection. The drive starts output phase loss detection when the output current decreases to less than 5% of the drive rated current.
Note:
The drive can incorrectly start output phase loss detection in these conditions:
The motor rated current is very small compared to the drive rating.
The drive is operating a PM motor with a small load.
0 : Disabled
1 : Fault when one phase is lost
2 : Fault when two phases are lost
Output Ground Fault Detection
Sets the function to enable and disable ground fault protection.
0 : Disabled
1 : Enabled
Heatsink Fan Operation Selection
Sets operation of the heatsink cooling fan.
0 : During Run, w/ L8-11 Off-Delay
1 : Always On
2 : On when Drive Temp Reaches L8-64
Heatsink Fan Off-Delay Time
Ambient Temperature Setting
Sets the length of time that the drive will wait before it stops the cooling fan after it cancels the Run command when L8-10 = 0 [Heatsink Cooling Fan Ope Select = Dur Run (OffDly)].
Sets the ambient temperature of the drive installation area.
Note:
The setting range changes when the L8-35 [Installation Method Selection] value changes:
0 [IP20/UL Open Type]: -10 °C to +60 °C
1 [Side-by-Side Mounting]: -10 °C to +50 °C
2 [IP20/UL Type 1]: -10 °C to +50 °C
3 [External Heatsink]: -10 °C to +50 °C
Drive oL2 @ Low Speed Protection
Sets the function to decrease drive overload at low speeds to prevent damage to the main circuit transistor during low speed operation (at 6 Hz or slower) to prevent oL2 [Drive Overloaded].
Note:
Contact Yaskawa or your nearest sales representative before disabling this function at low speeds. If you frequently operate drives with high output current in low speed ranges, it can cause heat stress and decrease the life span of drive IGBTs.
0 : Disabled (No Additional Derate)
1 : Enabled (Reduced oL2 Level)
Software Current Limit Selection
Set the software current limit selection function to prevent damage to the main circuit transistor caused by too much current.
0 : Disabled
1 : Enabled
Freq Reduction @ oH Pre-Alarm
Overcurrent Detection Gain
Sets the ratio at which the drive derates the frequency reference during an oH alarm.
Sets the PM motor overcurrent detection level as a percentage of the motor rated current value.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 ≠ 8[EZOLV]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8: E9-06 [Motor Rated Current (FLA)]
Output Unbalance Detection Sel
Sets the function to detect LF2.
0 : Disabled
1 : Enabled
LF2 Detection Time
Sets the LF2 [Output Current Imbalance] detection time.
Default
(Range)
1
(0 - 2)
Determined by o2-04
(0, 1)
0
(0 - 2)
60 s
(0 - 300 s)
40 °C
(-10 °C - +60 °C)
1
(0, 1)
0
(0, 1)
0.8
(0.1 - 0.9)
300.0%
(0.0 - 1000.0%)
1
(0, 1)
3
(1 – 100)
Ref.
399
399
399
400
400
400
400
401
401
401
401
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 75
1.11 L: Protection Functions
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
L8-35
(04EC)
L8-40
(04F1)
L8-41
(04F2)
L8-51
(0471)
Expert
L8-52
(0472)
Expert
L8-53
(0473)
Expert
L8-54
(0474)
Expert
L8-55
(045F)
L8-56
(047D)
Expert
L8-57
(047E)
Expert
L8-90
(0175)
Expert
L8-93
(073C)
Expert
L8-94
(073D)
Expert
L8-95
(077F)
Expert
Name Description
Installation Method Selection
Sets the type of drive installation.
0 : IP20/UL Open Type
1 : Side-by-Side Mounting
2 : IP20/UL Type 1
3 : External Heatsink
Carrier Freq Reduction Off-Delay
High Current Alarm Selection
Sets the length of time until the automatically reduced carrier frequency returns to the condition before the reduction.
Sets the function to cause an HCA [Current Alarm] when the output current is more than 150% of the drive rated current.
0 : No
1 : Yes
STPo I Detection Level
Sets the STPo [Motor Step-Out Detected] detection level as a percentage of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5 [OLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
STPo Integration Level
Sets the detection level for STPo [Motor Step-Out Detected] related to the ACR integral value.
STPo Integration Time
Sets the length of time until the drive detects STPo after it is more than the value of L8-51 [STPo I Detection Level].
STPo Id Diff Detection
Sets the Id deviation detection function for STPo [Motor Step-Out Detected].
0 : Disabled
1 : Enabled
Internal DB TransistorProtection
Sets the protection function for the internal braking transistor.
0 : Disable
1 : Protection Enabled
Stall P @ Accel Activation Time
Stall Prevention Retry Counts
STPo Detection Level (Low Speed)
Low Speed Pull-out DetectionTime
Low Speed Pull-out Detect Level
Low Speed Pull-out Amount
Sets the length time that the acceleration stall prevention function can continue to operate before the drive detects an STPo [Motor Step-Out Detected].
Sets the number of times the acceleration stall prevention function can operate until speeds agree before the drive detects an STPo [Motor Step-Out Detected].
Sets the detection level that the control fault must be equal to or more than to cause an STPo [Motor Step-Out Detected].
Sets the length of time the drive will wait to start baseblock after detecting LSo [Low Speed Motor Step-Out].
Sets the detection level for LSo [Low Speed Motor Step-Out] as a percentage of E1-04 [Maximum Output Frequency].
Sets the average count of LSo [Low Speed Motor Step-Out] detections.
Default
(Range)
0
(0 - 3)
Determined by A1-02
(0.00 - 2.00 s)
0
(0, 1)
0.0%
(0.0 - 300.0%)
1.0
(0.1 - 2.0)
1.0 s
(1.0 - 10.0 s)
1
(0, 1)
1
(0, 1)
5000 ms
(100 - 5000 ms)
10
(1 - 10 times)
Determined by A1-02
(0 - 5000 times)
1.0 s
(0.0 - 10.0 s)
3%
(0 - 10%)
10
(1 - 50 times)
Ref.
401
402
402
402
403
403
403
403
403
404
404
404
404
404
76 YASKAWA TOEPYAIGA5002A GA500 Programming
1.12 n: Special Adjustment
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

n1: Hunting Prevention

1.12 n: Special Adjustment

No.
(Hex.)
n1-01
(0580)
n1-02
(0581)
Expert
n1-03
(0582)
Expert
n1-05
(0530)
Expert
n1-13
(1B59)
Expert
n1-14
(1B5A)
Expert
Name Description
Hunting Prevention Selection
Sets the function to prevent hunting.
Note:
When you replace a V1000-series drive with a GA500 drive, set n1-01 = 1 [Hunting Prevention Selection = Enabled].
0 : Disable
1 : Enabled
Hunting Prevention Gain Setting
Hunting Prevention Time Constant
Hunting Prevent Gain in Reverse
DC Bus Stabilization Control
Sets the performance of the hunting prevention function. Usually it is not necessary to change this parameter.
Sets the primary delay time constant of the hunting prevention function. Usually it is not necessary to change this parameter.
Sets the performance of the hunting prevention function. This parameter adjusts Reverse run. Usually it is not necessary to change this parameter.
Sets the oscillation suppression function for the DC bus voltage.
0 : Disabled
1 : Enabled
DC Bus Stabilization Time
Adjusts the responsiveness of the oscillation suppression function for the DC bus voltage. Set n1-13 = 1 [DC Bus Stabilization Control = Enabled] to enable this parameter.
Default
(Range)
0
( 0, 1 )
1.00
(0.00 - 2.50)
Determined by o2-04
(0 - 500 ms)
0.00
(0.00 - 2.50)
0
(0, 1)
100.0 ms
(50.0 - 500.0 ms)
Ref.
405
405
405
405
406
406

n2: Auto Freq Regulator (AFR)

No.
(Hex.)
n2-01
(0584)
n2-02
(0585)
n2-03
(0586)
Name Description
Automatic Freq Regulator Gain
Automatic Freq Regulator Time 1
Automatic Freq Regulator Time 2
Sets the gain of the AFR function as a magnification value. Usually it is not necessary to change this setting.
Sets the time constant that sets the rate of change for the AFR function. Usually it is not necessary to change this setting.
Sets the time constant that sets the speed difference of the AFR function. Use this parameter for speed searches or regeneration. Usually it is not necessary to change this setting.

n3: High Slip/Overexcite Braking

No.
(Hex.)
n3-01
(0588)
Expert
n3-02
(0589)
Expert
Name Description
HSB Deceleration Frequency Width
Sets the amount by which the output frequency is to be lowered during high-slip braking, as a percentage of E1-04 [Maximum Output Frequency], which represents the 100% value.
HSB Current Limit Level
Sets the maximum current output during high-slip braking as a percentage, where E2-01 [Motor Rated Current (FLA)] is 100%. Also set the current suppression to prevent exceeding drive overload tolerance.
Note:
The upper limit to the setting range changes when the setting for C6-01 [Normal / Heavy Duty Selection] changes.
150% when C6-01 = 0 [Heavy Duty Rating]
120% when C6-01 = 1 [Normal Duty Rating]
Default
(Range)
1.00
(0.00 - 10.00)
50 ms
(0 - 2000 ms)
750 ms
(0 - 2000 ms)
Default
(Range)
5%
(1 - 20%)
Determined by C6-01
(0 - 150%)
Ref.
406
407
407
Ref.
409
409
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 77
1.12 n: Special Adjustment
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
n3-03
(058A)
Expert
n3-04
(058B)
Expert
n3-13
(0531)
n3-14
(0532)
Expert
Name Description
HSB Dwell Time at Stop
Sets the dwell time, a length of time when high-slip braking is ending and during which the motor speed decreases and runs at a stable speed. For a set length of time, the drive will hold the actual output frequency at the minimum output frequency set in E1-09.
HSB Overload Time
Sets the time used to detect oL7 [High Slip Braking Overload], which occurs when the output frequency does not change during high-slip braking. Usually it is not necessary to change this parameter.
OverexcitationBraking (OEB) Gain
OEB High Frequency Injection
Sets the gain value that the drive multiplies by the V/f pattern output value during overexcitation deceleration to calculate the overexcitation level.
Sets the function that injects harmonic signals during overexcitation deceleration.
0 : Disabled
1 : Enabled
n3-21
(0579)
n3-23
(057B)
HSB Current Suppression Level
Overexcitation Braking Operation
Sets the upper limit of the current that is suppressed at the time of overexcitation deceleration as a percentage of the drive rated current.
Sets the direction of motor rotation where the drive will enable overexcitation.
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV

n5: Feed Forward Control

Default
(Range)
1.0 s
(0.0 - 10.0 s)
40 s
(30 - 1200 s)
1.10
(1.00 - 1.40)
0
(0, 1)
100%
(0 - 150%)
0
(0 - 2)
Ref.
409
409
410
410
410
410
No.
(Hex.)
n5-01
(05B0)
n5-02
(05B1)
n5-03
(05B2)
n5-04
(05B3)
Name Description
Feed Forward Control Selection
Motor Inertia Acceleration Time
Feed Forward Control Gain
Speed Response Frequency
RUN
Expert

n6: Online Tuning

No.
(Hex.)
n6-01
(0570)
n6-05
(05C7)
Expert
Name Description
Online Tuning Selection
Online Tuning Gain
Sets the feed forward function.
0 : Disabled
1 : Enabled
Sets the length of time for the motor to accelerate from the stopped to the maximum frequency with a single motor at the rated torque. Inertia Tuning automatically sets the motor acceleration time.
Sets the ratio between load inertia and motor inertia. Inertia Tuning automatically sets the Feedforward Control Gain value.
Sets the response frequency for the speed reference. Usually it is not necessary to change this parameter.
Sets the type of motor data that Online Tuning uses for OLV control.
0 : Disabled
1 : Line-to-Line Resistance Tuning
2 : Voltage Correction Tuning
Sets the compensation gain when n6-01 = 2 [Online Tuning Selection = Voltage Correction Tuning]. Usually it is not necessary to change this parameter.
Default
(Range)
0
(0, 1)
Determined by C6-01,
E5-01, and o2-04
(0.001 - 10.000 s)
1.00
(0.00 - 100.00)
Determined by A1-02
(0.00 - 500.00 Hz)
Default
(Range)
0
(0 - 2)
1.0
(0.1 - 50.0)
Ref.
411
412
412
413
Ref.
413
414
78 YASKAWA TOEPYAIGA5002A GA500 Programming

n7: EZ Drive

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.12 n: Special Adjustment
No.
(Hex.)
n7-01
(3111)
Expert
n7-05
(3115)
Expert
n7-07
(3117)
Expert
n7-08
(3118)
Expert
n7-10
(311A)
Expert
n7-17
(3122)
n7-19
(3128)
Expert
Name Description
Damping Gain for Low Frequency
Response Gain for Load Changes
Sets the oscillation suppression gain for the low speed range.
Sets the response gain related to changes in the load.
Speed Calculation Gain1
Sets the speed calculation gain during usual operation. Usually it is not necessary to change this setting.
Speed Calculation Gain2
Sets the speed calculation gain during a speed search.
Pull-in Current Switching Speed
Resistance TemperatureCorrection
Sets the speed range to operate with the pull-in current command. Drive rated frequency = 100% value. If there is a large quantity of oscillation when you operate in the low speed range, increase the setting value.
Sets the function to adjust for changes in the motor resistance value caused by changes in the temperature.
0 : Invalid
1 : Valid (Only 1 time)
2 : Valid (Every time)
Flux Error Compensation Gain
Sets the gain for magnetic flux compensation. Usually it is not necessary to change this setting.
Default
(Range)
1.0
(0.1 - 10.0)
50
(10 - 1000)
15.0 Hz
(1.0 - 50.0 Hz)
25.0 Hz
(1.0 - 50.0 Hz)
10.0%
(0.0 - 100.0%)
1
(0 to 2)
5000%
(0 - 50000%)
Ref.
414
414
414
414
415
415
415

n8: PM Motor Control Tuning

No.
(Hex.)
n8-01
(0540)
n8-02
(0541)
n8-11
(054A)
n8-14
(054D)
Expert
n8-15
(054E)
Expert
n8-21
(0554)
Expert
n8-23
(0556)
Expert
n8-24
(0557)
Expert
n8-25
(0558)
Expert
Name Description
Pole Position Detection Current
Pole Alignment Current Level
Observer Calculation Gain 2
Polarity Compensation Gain 3
Polarity Compensation Gain 4
Motor Back-EMF (Ke) Gain
Sets, as a percentage, the Initial Rotor Position Estimated Current, taking the E5-03 [Motor Rated Current (FLA)] as the 100% value. Usually it is not necessary to change this setting.
Sets the current at the time of polar attraction as a percentage where E5-03 [motor rated current] is 100%. Usually it is not necessary to change this setting.
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
ACR q Gain @PoleEst
Sets the proportional gain for current regulator q-axis control when the drive estimates the initial pole. Usually it is not necessary to change this setting.
ACR q Integral Time @PoleEst
Sets the integral time for current regulator q-axis control when the drive estimates the initial pole. Usually it is not necessary to change this setting.
ACR q Limit @PoleEst
Sets the q-axis limit of the current regulator when the drive estimates the initial pole. Usually it is not necessary to change this setting.
Default
(Range)
50%
(0 - 100%)
80%
(0 - 150%)
Determined by n8-72
(0.0 - 1000.0)
1.000
(0.000 - 10.000)
0.500
(0.000 - 10.000)
0.90
(0.80 - 1.00)
0
(0 - 2000)
0.0 ms
(0.0 - 100.0 ms)
0%
(0 - 150%)
Ref.
415
416
416
416
416
416
416
416
417
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 79
1.12 n: Special Adjustment
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
n8-26
(0559)
Expert
n8-27
(055A)
Expert
n8-28
(055B)
Expert
n8-35
(0562)
n8-36
(0563)
n8-37
(0564)
Expert
n8-39
(0566)
n8-41
(0568)
Expert
n8-42
(0569)
Expert
n8-45
(0538)
n8-46
(0539)
Expert
n8-47
(053A)
n8-48
(053B)
RUN
Name Description
ACR d Gain @PoleEst
Sets the proportional gain for current regulator d-axis control when the drive estimates the initial pole. Usually it is not necessary to change this setting.
ACR d Integral Time @PoleEst
Sets the integral time for current regulator d-axis control when the drive estimates the initial pole. Usually it is not necessary to change this setting.
ACR d Lim @PoleEst
Sets the d-axis limit of the current regulator when the drive estimates the initial pole. Usually it is not necessary to change this setting.
Initial Pole Detection Method
Sets how the drive detects the position of the rotor when the motor starts.
Note:
When you use an SPM motor, set n8-35 = 0. When you use an IPM motor, set n8-35
= 0 to 2.
When you set n8-35 = 1, do High Frequency Injection Auto-Tuning.
0 : Pull-in
1 : High Frequency Injection
2 : Pulse Injection
HFI Frequency Level for L Tuning
HFI Voltage Amplitude Level
Sets the injection frequency for high frequency injection.
Note:
Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57
= 1 [HFI Overlap Selection = Enabled] to enable this parameter.
The drive automatically calculates this value when High Frequency Injection Auto-
Tuning completes successfully.
Sets the high frequency injection amplitude as a percentage where 200 V = 100% for 200 V class drives and 400 V = 100% for a 400 V class drives. Usually it is not necessary to change this setting.
Note:
Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57
= 1 [HFI Overlap Selection = Enabled] to enable this parameter.
The drive automatically calculates this value when High Frequency Injection Auto-
Tuning completes successfully.
HFI LPF Cutoff Freq
Sets the low-pass filter shut-off frequency for high frequency injection.
Note:
Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57
= 1 [HFI Overlap Selection = Enabled] to enable this parameter.
The drive automatically calculates this value when High Frequency Injection Auto-
Tuning completes successfully.
HFI P Gain
Sets the response gain for the high frequency injection speed estimation.
Note:
Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57
= 1 [HFI Overlap Selection = Enabled] to enable this parameter.
When A1-02= 6 [Control Method Selection = AOLV/PM], if you do High Frequency
Injection Auto-Tuning, the drive automatically sets this parameter .
HFI I Time
Sets the integral time constant for the high frequency injection speed estimation. Usually it is not necessary to change this setting.
Speed Feedback Detection Gain
PM Phase Compensation Gain
Pull-in Current Comp Filter Time
Pull-in/Light Load Id Current
Sets the internal speed feedback detection reduction unit gain as a magnification value. Usually it is not necessary to change this setting.
Sets the gain to compensate for phase differences. Usually it is not necessary to change this setting.
Sets the time constant the drive uses to align the pull-in current reference value with the actual current value. Usually it is not necessary to change this setting.
On the basis that parameter E5-03 [Motor Rated Current (FLA)] is the 100% value, this parameter sets the d-axis current that flows to the motor during run at constant speed as a percentage.
Default
(Range)
500
(0 - 2000)
0.0 ms
(0.0 - 100.0 ms)
100%
(0 - 150%)
Determined by A1-02
(0 - 2)
500 Hz
(200 - 1000 Hz)
20.0%
(0.0 - 50.0%)
250 Hz
(0 - 1000 Hz)
2.5
(-10.0 - +10.0)
0.10 s
(0.00 - 9.99 s)
0.80
(0.00 - 10.00)
0.3
(0.0 - 10.0)
5.0 s
(0.0 - 100.0 s)
30%
(0 - 200%)
Ref.
417
417
417
417
418
418
418
418
418
419
419
419
419
80 YASKAWA TOEPYAIGA5002A GA500 Programming
1.12 n: Special Adjustment
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
n8-49
(053C)
RUN
Expert
n8-50
(053D)
Expert
n8-51
(053E)
n8-54
(056D)
Expert
n8-55
(056E)
n8-57
(0574)
n8-62
(057D)
Expert
n8-63
(057E)
Expert
n8-65
(065C)
Expert
n8-69
(065D)
Expert
n8-72
(0655)
Expert
n8-74
(05C3)
Expert
n8-75
(05C4)
Expert
n8-77
(05CE)
Expert
Name Description
Heavy Load Id Current
Sets the d-axis current to that the drive will supply to the motor to run it at a constant speed with a heavy load. Considers E5-03 [PM Motor Rated Current (FLA)] to be 100%. Usually it is not necessary to change this setting.
Medium Load Iq Level (High)
Pull-in Current @ Acceleration
Sets the load current level at which heavy load control starts where E5-03 [Motor Rated Current (FLA)] is 100%. Usually it is not necessary to change this setting.
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5 [OLV/PM]: E5-03 [Motor Rated Current (FLA)]
A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
Voltage Error Compensation Time
Motor to Load Inertia Ratio
Sets the time constant that the drive uses when adjusting for voltage errors.
Sets the ratio between motor inertia and machine inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
HFI Overlap Selection
Sets the function that detects motor speed with high frequency injection.
Note:
When you set n8-57 = 1, do High Frequency Injection Auto-Tuning.
0 : Disabled
1 : Enabled
Output Voltage Limit Level
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not necessary to change this parameter.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], the default settings are:
200 V class: 230.0 V
400 V class: 460.0 V
Output Voltage Limit P Gain
Speed Fdbk Gain @ oV Suppression
Speed Observer Control P Gain
Speed Estimation Method Select
Sets the proportional gain for output voltage control. Usually it is not necessary to change this setting.
Sets the gain of internal speed feedback detection suppression while the overvoltage suppression function is operating as a magnification value. Usually it is not necessary to change this parameter.
Usually it is not necessary to change this setting. Sets the Proportional gain that the drive uses for speed estimation.
Selects the speed estimation method. Usually it is not necessary to change this setting.
0 : Method 1
1 : Method 2
Light Load Iq Level
Set n8-48 [Pull-in/Light Load Id Current] to the percentage of load current (q-axis current) that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of 100%.
Medium Load Iq Level (low)
Set n8-78 [Medium Load Id Current] to the percentage of load current (q-axis current) that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of 100%.
Heavy Load Iq Level
Set n8-49 [Heavy Load Id Current] to the percentage of load current (q-axis current) that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of 100%.
Default
(Range)
Determined by E5-01
(-200.0 - +200.0%)
80%
(50 - 255)
Determined by A1-02
(0 - 200%)
1.00 s
(0.00 - 10.00 s)
0
(0 - 3)
0
(0, 1)
200 V Class: 200.0 V, 400
V: 400.0 V
(200 V Class: 0.0 to 240.0
V, 400 V Class: 0.0 to
480.0 V)
1.00
(0.00 - 100.00)
1.50
(0.00 - 10.00)
1.00
(0.00 - 20.00)
1
(0, 1)
30%
(0 - 255%)
50%
(0 - 255%)
90%
(0 - 255%)
Ref.
420
420
420
420
421
421
422
422
422
422
422
423
423
423
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 81
1.12 n: Special Adjustment
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
n8-78
(05F4)
RUN
Expert
n8-79
(05FE)
n8-84
(02D3)
Expert
n8-87
(02BC)
n8-88
(02BD)
n8-89
(02BE)
n8-90
(02BF)
n8-91
(02F7)
n8-94
(012D)
Expert
n8-95
(012E)
Expert
Name Description
Medium Load Id Current
Sets the level of the pull-in current as a percentage, where E5-03 [PM Motor Rated Current (FLA)] = 100%.
Pull-in Current @ Deceleration
Sets the pull-in current that can flow during deceleration as a percentage of the E5-03 [PM Motor Rated Current (FLA)].
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Pull-in Current @ Acceleration].
Polarity Detection Current
Output Voltage Limit Method
Sets the current that the drive uses to estimate the initial motor magnetic pole as a percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%.
Sets the method of output voltage limit. If there is vibration in the constant output range, set Feedforward Method. Usually it is not necessary to change this setting.
0 : Feedback Method
1 : Feedforward Method
Vout Limit Switching Level
Sets the current level at which output voltage limit sequence selection occurs as a percentage where the motor rated current is 100%. Normally there is no need to change this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
Vout Limit Switching Hysteresis
Sets the hysteresis width of the current level at which output voltage limit sequence selection occurs as a percentage where the motor rated current is 100%. Normally there is no need to change this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
Vout Limit Switching Speed
Sets the speed level at which output voltage limit sequence selection occurs as a percentage where the maximum output frequency is 100%. Usually it is not necessary to change this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Motor Max Revolutions]
Id Limit at Voltage Saturation
Flux Position Estimation Method
Sets the limit value of feedback output voltage limit Id operation. Enabled when n8-87 = 0 [Output Voltage Control Selection = Speed Feedback Form]. Usually it is not necessary to change this setting.
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not necessary to change this setting.
0 : Softstarter
1 : Speed Feedback
Flux Position Est Filter Time
Sets the time constant of the filter used for the recognition criteria value for speed and load changes. Usually it is not necessary to change this setting.
Default
(Range)
0%
(0 - 255%)
50%
(0 - 200%)
100%
(0 - 150%)
0
(0, 1)
400%
(0 - 400%)
3%
(0 - 400%)
200%
(0 - 200%)
-50%
(-200 - 0%)
1
(0, 1)
30 ms
(0 - 100 ms)
Ref.
423
423
424
424
424
424
424
424
425
425

nA: PM Motor Control Tuning

No.
(Hex.)
nA-01
(3129)
Expert
82 YASKAWA TOEPYAIGA5002A GA500 Programming
Name Description
Observer Calc Gain 3
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
Default
(Range)
30.0
(0.0 - 1000.0)
Ref.
425
1.13 o: Keypad-Related Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

o1: Keypad Display

1.13 o: Keypad-Related Settings

No.
(Hex.)
o1-01
(0500)
RUN
o1-02
(0501)
RUN
o1-03
(0502)
o1-04
(0503)
o1-05
(0504)
RUN
o1-10
(0520)
o1-11
(0521)
o1-24 to o1-35:
(11AD - 11B8)
RUN
o1-36
(11B9)
RUN
o1-37
(11BA)
RUN
o1-38
(11BB)
RUN
o1-39
(11BC)
RUN
Name Description
User Monitor Selection
Sets the U monitor for the Drive Mode. This parameter is only available when you use an LED keypad.
Monitor Selection at Power-up
Sets the monitor item that the keypad screen shows after energizing the drive. Refer to U: Monitorsfor information about the monitor items that the keypad screen can show. This parameter is only available when you use an LED keypad.
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
Frequency Display Unit Selection
Sets the display units for the frequency reference and output frequency.
0 : 0.01Hz units
1 : 0.01% units
2 : Revolutions Per Minute (RPM)
3 : User Units
V/f Pattern Display Unit
Sets the setting unit for parameters that set the V/f pattern frequency.
0 : Hz
-1
1 : min
(r/min) unit
LCD Contrast Adjustment
User Units Maximum Value
User Units Decimal Position
Sets the contrast of the LCD display on the keypad.
Sets the value that the drive shows as the maximum output frequency.
Sets the number of decimal places for frequency reference and monitor values.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
Custom Monitor 1 to 12
Sets a maximum of 12 monitors as user monitors. This parameter is only available when using an LCD keypad.
LCD Backlight Brightness
LCD Backlight ON/OFF Selection
Sets the intensity of the LCD keypad backlight.
Sets the automatic shut off function for the LCD backlight.
0 : OFF
1 : ON
LCD Backlight Off-Delay
Sets the time until the LCD backlight automatically turns off.
Show Initial Setup Screen
Sets the function to show the LCD keypad initial setup screen each time the drive is energized. This parameter is only available when using an LCD keypad.
0 : No
1 : Yes
Default
(Range)
106
(104 - 855)
1
(1 - 5)
Determined by A1-02
(0 - 3)
Determined by A1-02
(0, 1)
5
(0 - 10)
Determined by o1-03
(1 - 60000)
Determined by o1-03
(0 - 3)
o1-24: 101
o1-25: 102
o1-26: 103
o1-27 to o1-35: 0
(0, 101 - 999)
5
(1 - 5)
1
(0, 1)
60 s
(10 - 300 s)
1
(0, 1)
Ref.
427
427
427
428
429
429
429
429
430
430
430
431
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 83
1.13 o: Keypad-Related Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
o1-40
(11BD)
RUN
o1-41
(11C1)
RUN
o1-42
(11C2)
RUN
o1-43
(11C3)
RUN
o1-44
(11C4)
RUN
o1-45
(11C5)
RUN
o1-46
(11C6)
RUN
o1-47
(11C7)
RUN
o1-48
(11C8)
RUN
o1-49
(11C9)
RUN
o1-50
(11CA)
RUN
o1-51
(11CB)
RUN
o1-55
(11EE)
RUN
Name Description
Home Screen Display Selection
Sets the monitor display mode for the Home screen. This parameter is only available when using an LCD keypad.
0 : Custom Monitor
1 : Bar Graph
2 : Analog Gauge
3 : Trend Plot
1st Monitor Area Selection
Sets the horizontal range used to display the monitor set in o1-24 [Custom Monitor 1] as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
2 : - Area ( - o1-42 ~ 0 )
1st Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar graph. This parameter is only available when using an LCD keypad.
2nd Monitor Area Selection
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
2 : - Area ( - o1-44 ~ 0 )
2nd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a bar graph. This parameter is only available when using an LCD keypad.
3rd Monitor Area Selection
Sets the horizontal range used to display the monitor set in o1-26 [Custom Monitor 3] as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
2 : - Area ( - o1-46 ~ 0 )
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a bar graph. This parameter is only available when using an LCD keypad.
Trend Plot 1 Scale Minimum Value
Trend Plot 1 Scale Maximum Value
Trend Plot 2 Scale Minimum Value
Trend Plot 2 Scale Maximum Value
Trend Plot Time Scale Setting
Analog Gauge Area Selection
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available when using an LCD keypad.
Sets the horizontal axis maximum value used to display the monitor set in o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available when using an LCD keypad.
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available when using an LCD keypad.
Sets the horizontal axis maximum value used to display the monitor set in o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available when using an LCD keypad.
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the drive automatically adjusts the data sampling time. This parameter is only available when using an LCD keypad.
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
Default
(Range)
0
(0 - 3)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
300 s
(1 - 3600 s)
1
(0, 1)
Ref.
431
431
431
431
432
432
432
432
432
432
432
433
433
84 YASKAWA TOEPYAIGA5002A GA500 Programming
1.13 o: Keypad-Related Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
o1-56
(11EF)
RUN
o1-58
(3125)
Name Description
Analog Gauge Area Setting
Motor Power Unit Selection
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter. This parameter is only available when using an LCD keypad.
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP

o2: Keypad Operation

No.
(Hex.)
o2-01
(0505)
o2-02
(0506)
o2-03
(0507)
o2-04
(0508)
o2-05
(0509)
o2-06
(050A)
o2-07
(0527)
o2-09
(050D)
o2-19
(061F)
Expert
o2-23
(11F8)
RUN
Name Description
LO/RE Key Function Selection
Sets the function that lets you use to switch between LOCAL and REMOTE Modes.
0 : Disabled
1 : Enabled
STOP Key Function Selection
Sets the function to use on the keypad to stop the drive when the Run command source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
User Parameter Default Value
Sets the function to keep the settings of changed parameters as user parameter defaults to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
Drive Model (KVA) Selection
Home Mode Freq Ref Entry Mode
Sets the Drive Model code. Set this parameter after replacing the control board.
Sets the function that makes it necessary to push to use the keypad to change the frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
Keypad Disconnect Detection
Sets the function that stops the drive if you disconnect the keypad connection cable from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
Keypad RUN Direction @ Power-up
Sets the direction of motor rotation when the drive is energized and the keypad is the Run command source.
0 : Forward
1 : Reverse
Reserved - - 436
Parameter Write during Uv
Lets you change parameters during Uv [Undervoltage].
0 : Disable
1 : Enabled
External 24V Powerloss Detection
Sets the function to give a warning if the backup external 24 V power supply turns off when the main circuit power supply is in operation.
0 : Disable
1 : Enabled
Default
(Range)
100.0%
(0.0 - 100.0%)
1
(0, 1)
Default
(Range)
1
(0, 1)
1
(0, 1)
0
(0 - 2)
Determined by the drive
(-)
0
(0, 1)
1
(0, 1)
0
(0, 1)
0
( 0, 1 )
0
(0, 1)
Ref.
433
433
Ref.
433
434
434
435
435
436
436
Parameter List
1
436
437
YASKAWA TOEPYAIGA5002A GA500 Programming 85
1.13 o: Keypad-Related Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
o2-26
(1563)
Name Description
Alarm display at ext. 24V power
When you connect a backup external 24 V power supply, this parameter sets the function to trigger an alarm when the main circuit power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : No
1 : Yes
o2-27
(1565)
bCE Detection Selection
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display

o3: Copy Keypad Function

No.
(Hex.)
o3-01
(0515)
o3-02
(0516)
o3-04
(0B3E)
o3-05
(0BDA)
o3-06
(0BDE)
o3-07
(0BDF)
Name Description
Copy Keypad Function Selection
Sets the function that saves and copies drive parameters to a different drive with the keypad.
0 : Copy Select
1 : Backup (drive → keypad)
2 : Restore (keypad → drive)
3 : Verify (check for mismatch)
4 : Erase (backup data of keypad)
Copy Allowed Selection
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive → keypad)].
0 : Disabled
1 : Enabled
Select Backup/Restore Location
Sets the storage location for drive parameters when you back up and restore parameters. This parameter is only available when using an LCD keypad.
0 : Memory Location 1
1 : Memory Location 2
2 : Memory Location 3
3 : Memory Location 4
Select Items to Backup/ Restore
Sets which parameters are backed up, restored, and referenced. This parameter is only available when using an LCD keypad.
0 : Standard Parameters
1 : Standard + DWEZ Parameters
Auto Parameter Backup Selection
Sets the function that automatically backs up parameters. This parameter is only available when using an LCD keypad.
0 : Disabled
1 : Enabled
Auto Parameter Backup Interval
Sets the interval at which the automatic parameter backup function saves parameters from the drive to the keypad.
Note:
This parameter is only available when using an LCD keypad.
0 : Every 10 minutes
1 : Every 30 minutes
2 : Every 60 minutes
3 : Every 12 hours
Default
(Range)
1
(0, 1)
3
(0 - 4)
Default
(Range)
0
(0 - 4)
0
(0, 1)
0
(0 - 3)
1
(0, 1)
1
(0, 1)
1
(0 - 3)
Ref.
437
437
Ref.
437
438
438
438
439
439
86 YASKAWA TOEPYAIGA5002A GA500 Programming

o4: Maintenance Monitors

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.13 o: Keypad-Related Settings
No.
(Hex.)
o4-01
(050B)
o4-02
(050C)
o4-03
(050E)
o4-05
(051D)
o4-07
(0523)
o4-09
(0525)
o4-11
(0510)
o4-12
(0512)
o4-13
(0528)
o4-22
Name Description
Elapsed Operating Time Setting
Elapsed Operating Time Selection
Fan Operation Time Setting
Capacitor Maintenance Setting
Softcharge Relay Maintenance Set
IGBT Maintenance Setting
Fault Trace/History Init (U2/U3)
kWh Monitor Initialization
RUN Command Counter @ Initialize
Time Format
(154F)
RUN
o4-23
Date Format
(1550)
RUN
o4-24
bAT Detection Selection
(310F)
RUN

o5: Log Function

Sets the initial value of the cumulative drive operation time in 10-hour units.
Sets the condition that counts the cumulative operation time.
0 : U4-01 Shows Total Power-up Time
1 : U4-01 Shows Total RUN Time
Sets the value from which to start the cumulative drive cooling fan operation time in 10­hour units.
Sets the U4-05 [CapacitorMaintenance] monitor value.
Sets the U4-06 [PreChargeRelayMainte] monitor value.
Sets the U4-07 [IGBT Maintenance] monitor value.
Resets the records of Monitors U2-xx [Fault Trace] and U3-xx [Fault History].
0 : Disabled
1 : Enabled
Resets the monitor values for U4-10 [kWh, Lower 4 Digits] and U4-11 [kWh, Upper 5 Digits].
0 : No Reset
1 : Reset
Resets the monitor values for U4-02 [Num of Run Commands], U4-24 [Number of Runs (Low)], and U4-25 [Number of Runs (High)].
0 : No Reset
1 : Reset
Sets the time display format. This parameter is only available when using an LCD keypad.
0 : 24 Hour Clock
1 : 12 Hour Clock
2 : 12 Hour JP Clock
Sets the date display format. This parameter is only available when using an LCD keypad.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
Sets the operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM [Keypad Time Not Set]. This parameter is only available when you use an LCD keypad.
0 : Disable
1 : Enable (Alarm Detected)
2 : Enable (Fault Detected)
Default
(Range)
0 h
(0 - 9999 h)
0
(0, 1)
0 h
(0 - 9999 h)
0%
(0 - 150%)
0%
(0 - 150%)
0%
(0 - 150%)
0
(0, 1)
0
(0, 1)
0
(0, 1)
1
(0 - 2)
2
(0 - 2)
0
(0 - 2)
Ref.
439
440
440
440
440
440
441
441
441
441
442
442
Parameter List
1
No.
(Hex.)
o5-01
(1551)
RUN
Name Description
Log Start/Stop Selection
Sets the data log function. This parameter is only available when using an LCD keypad.
0 : OFF
Default
(Range)
0
(0 - 1)
Ref.
445
1 : ON
o5-02
(1552)
RUN
Log Sampling Interval
Sets the data log sampling cycle. This parameter is only available when using an LCD keypad.
100 ms
(100 - 60000 ms)
445
YASKAWA TOEPYAIGA5002A GA500 Programming 87
1.13 o: Keypad-Related Settings
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
o5-03
(1553)
RUN
o5-04
(1554)
RUN
o5-05
(1555)
RUN
o5-06
(1556)
RUN
o5-07
(1557)
RUN
o5-08
(1558)
RUN
o5-09
(1559)
RUN
o5-10
(155A)
RUN
o5-11
(155B)
RUN
o5-12
(155C)
RUN
Name Description
Log Monitor Data 1
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 2
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 3
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 4
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 5
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 6
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 7
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 8
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 9
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Log Monitor Data 10
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Default
(Range)
101
(000, 101 - 999)
102
(000, 101 - 999)
103
(000, 101 - 999)
107
(000, 101 - 999)
108
(000, 101 - 999)
V/f, OLV/PM : 000, OLV, AOLV/PM, EZOLV : 105
(000, 101 - 999)
110
(000, 101 - 999)
112
(000, 101 - 999)
000
(000, 101 - 999)
000
(000, 101 - 999)
Ref.
445
445
445
446
446
446
446
446
447
447
88 YASKAWA TOEPYAIGA5002A GA500 Programming
1.14 q: DriveWorksEZ Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

q1-01 to qx-xx: Reserved for DriveWorksEZ

1.14 q: DriveWorksEZ Parameters

No.
(Hex.)
q1-01 to qx-xx
(1600 - xxxx)
Name Description
Reserved for DriveWorksEZ
These parameters are reserved for use with DriveWorksEZ.
Default
(Range)
Refer to DriveWorksEZ
Operation Manual.
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 89

1.15 r: DWEZ Connection 1-20

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.15 r: DWEZ Connection 1-20

r1-01 to r1-40: DriveWorksEZ Connection Parameters 1 to 20 (Upper / Lower)

No.
(Hex.)
r1-01 to r1-40:
(1840 - 1867)
Name Description
DriveWorksEZ Connection Parameters 1 to 20 (Upper / Lower)
DriveWorksEZ Connection Parameters 1 to 20 (Upper / Lower)
Default
(Range)
0
(0 - FFFFH)
90 YASKAWA TOEPYAIGA5002A GA500 Programming
1.16 T: Motor Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

T0: Tuning Mode Selection

1.16 T: Motor Tuning

No.
(Hex.)
T0-00
(1197)
Name Description
Tuning Mode Selection
Sets the type of Auto-Tuning.
0 : Motor Parameter Tuning
1 : Control Tuning

T1: Induction Motor Auto-Tuning

No.
(Hex.)
T1-00
(0700)
T1-01
(0701)
T1-02
(0702)
T1-03
(0703)
T1-04
(0704)
T1-05
(0705)
T1-06
(0706)
T1-07
(0707)
T1-09
(0709)
T1-10
(070A)
T1-11
(070B)
Name Description
Motor 1/Motor 2 Selection
Sets which motor to tune when motor 1/2 switching is enabled.
You can only use the keypad to set this parameter. You cannot use external input terminals to set it.
Note:
This parameter is enabled when H1-xx = 16 [Motor 2 Selection] is set. When H1-xx ≠ 16 the keypad will not show this parameter.
1 : Motor 1
2 : Motor 2
Tuning Mode Selection
Sets the type of Auto-Tuning.
0 : Rotational Auto-Tuning
1 : Stationary Auto-Tuning 1
2 : Stationary Line-Line Resistance
Motor Rated Power
Uses the units set in o1-58 [Motor Power Unit Selection] to set the motor rated output power.
Motor Rated Voltage
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output motors.
Motor Rated Current
Sets the rated current (A) of the motor.
Motor Base Frequency
Sets the base frequency (Hz) of the motor.
Number of Motor Poles
Sets the number of motor poles.
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
Motor No-Load Current
Sets the no-load current of the motor.
Motor Rated Slip Frequency
Sets motor rated slip.
Motor Iron Loss
Sets the iron loss for calculating the energy-saving coefficient.
-1
(r/min)).
Default
(Range)
0
(0, 1)
Default
(Range)
1
(1, 2)
Determined by A1-02
(Determined by A1-02)
Determined by o2-04,
C6-01
(0.00 - 650.00 HP)
Determined by o2-04,
C6-01
(200 V Class: 0.0 - 255.5
V, 400 V Class: 0.0 -
511.0 V)
Determined by o2-04
(10% to 200% of the
drive rated current)
60.0 Hz
(0.0 - 590.0 Hz)
4
(2 to 120)
-1
1750 min
(0 - 35400 min
(r/min)
-1
(r/min))
-
(0A - T1-04; max. of
2999.9)
-
(0.000 - 20.000 Hz)
Determined by E2-11 or
E4-11
(0 - 65535 W)
Ref.
448
Ref.
448
449
449
449
449
449
450
450
450
450
450
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 91
1.16 T: Motor Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
T1-12
(0BDB)
Name Description
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the motor with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
Note:
You must first set T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz] to enable this parameter.
0 : No
1 : Yes
T1-13
(0BDC)
No-load voltage
Sets the no-load voltage of the motor. When the no-load voltage at rated speed is available, for example on the motor test report, set the voltage in this parameter. If the no-load voltage is not available, do not change this parameter.
Note:
To get the same qualities as a Yaskawa 1000-series drive or previous series drive, set
this parameter = T1-03 [Motor Rated Voltage].
The default setting is different for different models.B001 - B006, 2001 - 2008, 4001 - 4004: T1-03 × 0.85
B010 - B018, 2010 - 2082, 4005 - 4060: T1-03 × 0.90

T2: PM Motor Auto-Tuning

No.
(Hex.)
T2-01
(0750)
T2-02
(0751)
T2-03
(0752)
T2-04
(0730)
T2-05
(0732)
T2-06
(0733)
T2-07
(0753)
T2-08
(0734)
T2-09
(0731)
T2-10
(0754)
T2-11
(0735)
T2-12
(0736)
Name Description
PM Auto-Tuning Selection
Sets the type of Auto-Tuning for PM motors.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
4 : Rotational (Ld, Lq, R, Back-EMF)
5 : High Frequency Injection
PM Motor Code Selection
If the drive is operating an SMRD, SMRA, or SSR1 series Yaskawa PM motor, enter the PM motor code in to align with the rotation speed and motor output.
PM Motor Type
Sets the type of PM motor the drive will operate.
0 : IPM motor
1 : SPM motor
PM Motor Rated Power
Uses the units set in o1-58 [Motor Power Unit Selection] to set the PM motor rated output power.
PM Motor Rated Voltage
Sets the rated voltage (V) of the motor.
PM Motor Rated Current
Sets the rated current (A) of the motor.
PM Motor Base Frequency
Number of PM Motor Poles
Sets the base frequency (Hz) of the motor.
Sets the number of motor poles.
PM Motor Base Speed
Sets the motor base speed (min
PM Motor Stator Resistance
Sets the stator resistance for each motor phase.
Note:
This parameter does not set line-to-line resistance.
PM Motor d-Axis Inductance
PM Motor q-Axis Inductance
Sets the d-axis inductance of the motor on a per phase basis.
Sets the q-Axis inductance of the motor on a per phase basis.
-1
(r/min)).
Default
(Range)
0
(0, 1)
T1-03 × 0.9
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
Default
(Range)
0
(Determined by A1-02)
FFFF
(0000 - FFFF)
1
(0, 1)
Determined by o2-04,
C6-01
(0.00 - 650.00 HP)
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
Determined by o2-04
(10% to 200% of the
drive rated current)
60.0 Hz
(0.0 - 590.0 Hz)
4
(2 - 48)
-1
1750 min
(0 - 34500 min
(r/min)
-1
(r/min))
Determined by T2-02
(0.000 - 65.000 Ω)
Determined by T2-02
(0.00 - 600.00 mH)
Determined by T2-02
(0.00 - 600.00 mH)
Ref.
450
451
Ref.
451
451
452
452
452
452
452
452
452
453
453
453
92 YASKAWA TOEPYAIGA5002A GA500 Programming
1.16 T: Motor Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
T2-13
(0755)
Name Description
Back-EMF Units Selection
Sets the units that the drive uses to set the induced voltage constant.
0 : mV/(rev/min)
1 : mV/(rad/sec)
T2-14
(0737)
T2-15
(0756)
Back-EMF Voltage Constant (Ke)
Pull-In Current Level
Sets the motor induced voltage constant (Ke).
Sets the level of the pull-in current as a percentage of E5-03 [PM Motor Rated Current (FLA)]. Usually it is not necessary to change this setting.

T3: ASR and Inertia Tuning

No.
(Hex.)
T3-00
(1198)
Name Description
Control Loop Tuning Selection
Sets the type of Control Auto-Tuning.
2 : Deceleration Rate Tuning
3 : KEB Tuning

T4: EZ Tuning

No.
(Hex.)
T4-01
(3130)
T4-02
(3131)
T4-04
(3133)
T4-05
(3134)
T4-06
(3135)
T4-07
(3136)
T4-08
(3137)
T4-09
(3138)
Name Description
EZ Tuning Mode Selection
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
Motor Type Selection
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
Motor Rated Revolutions
Sets rated rotation speed (min
Motor Rated Frequency
Sets the rated frequency (Hz) of the motor.
Motor Rated Voltage
Sets the rated voltage (V) of the motor.
Motor Rated Current
Sets the rated current (A) of the motor.
Motor Rated Capacity
Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection].
Number of Poles
Sets the number of motor poles.
-1
) of the motor.
Default
(Range)
0
(0, 1)
Determined by T2-13
(0.0 - 2000.0)
30%
(0 - 120%)
Default
(Range)
2
(2, 3)
Default
(Range)
0
(0, 1)
0
(0, 1, 2)
-
((40 Hz to 120 Hz) × 60 ×
2/E9-08)
Determined by E9-01 and
o2-04
(40.0 - 120.0 Hz)
200 V Class: 230.0 V, 400
V: 460.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
Determined by E9-10
(0.10 - 650.00 HP)
Determined by E9-01
(2 - 48)
Ref.
453
453
453
Ref.
454
Ref.
454
454
454
455
455
455
455
455
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 93

1.17 U: Monitors

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.17 U: Monitors

U1: Operation Status Monitors

No.
(Hex.)
U1-01
(0040)
U1-02
(0041)
U1-03
(0042)
U1-04
(0043)
U1-05
(0044)
U1-06
(0045)
U1-07
(0046)
U1-08
(0047)
U1-09
(0048)
Name Description MFAO Signal Level
Frequency Reference
Output frequency
Output Current
Control method selection
Motor Speed
Output Voltage Ref
DC Bus Voltage
Output Power
Torque Reference
Shows the frequency reference value. Parameter o1-03 [Keypad Display Unit Selection] sets the display units.
Unit: 0.01 Hz
Shows the output frequency. Parameter o1-03 [Keypad Display Unit Selection] sets the display units.
Unit: 0.01 Hz
Shows the actual output current.
The keypad shows the value of U1-03 in amperes (A). When looking at the monitor through MEMOBUS/Modbus communications, the current is 8192 = drive rated current (A). Calculate the current from the monitor value that is in at MEMOBUS/Modbus communications using Numerals being displayed / 8192 × drive rated current (A).
Unit: When the drive model changes, the display units for this parameter also change.
0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
0.1A units: 2056 - 2082, 4031 - 4060
Shows the drive control method.
0 : V/f Control
2 : Open Loop Vector
5 : PM Open Loop Vector
6 : PM Advanced Open Loop Vector
8 : EZ Vector Control
Shows the detected motor speed. Parameter o1-03 [Keypad Display Unit Selection] sets the display units.
Unit: 0.01 Hz
Shows the output voltage reference.
Unit: 0.1 V
Shows the DC bus voltage.
Unit: 1 V
Shows the internally-calculated output power.
When you change A1-02 [Control Method Selection], it will also change the signal level of the analog output.
A1-02 = 0: Drive capacity (kW)
A1-02 = 2: Motor Rated Power [E2-11] (kW)
A1-02 = 5, 6: PM Motor Rated Power [E5-02] (kW)
A1-02 = 8: Motor Rated Power [E9-07] (kW)
Unit: When the drive model changes, the display units for this parameter also change.
0.01 A units: B001 to B018, 2001 to 2042, 4001 to 4023
0.1A units: 2056 - 2082, 4031 - 4060
Shows the internal torque reference value.
Unit: 0.1%
10 V = Maximum frequency
(0 V to +10 V)
10 V = Maximum frequency
(0 V to +10 V)
10 V = Drive rated current
No signal output available
10 V = Maximum frequency
(0 V to +10 V)
200 V class: 10 V = 200
Vrms
400 V class: 10 V = 400
Vrms
200 V class: 10 V = 400 V
400 V class: 10 V = 800 V
10 V: Drive capacity (motor
rated power) kW
(0 V to +10 V)
10 V = Motor rated torque (0
V to +10 V)
94 YASKAWA TOEPYAIGA5002A GA500 Programming
1.17 U: Monitors
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
U1-10
(0049)
U1-11
(004A)
U1-12
(004B)
Name Description MFAO Signal Level
Input Terminal Status
Output Terminal Status
Drive Status
Shows the status of the MFDO terminal where = ON and = OFF.
For example, U1-10 shows when terminals S1 and S3 are ON.
bit0 : Terminal S1 (MFDI 1)
bit1 : Terminal S2 (MFDI 2)
bit2 : Terminal S3 (MFDI 3)
bit3 : Terminal S4 (MFDI 4)
bit4 : Terminal S5 (MFDI 5)
bit5 : Terminal S6 (MFDI 6)
bit6 : Terminal S7 (MFDI 7)
bit7 : Not used (normal value of [ ]).
Shows the status of the MFDO terminal where = ON and = OFF.
For example, U1-11 shows when terminals MA and P2 are ON.
Note:
When H2-xx = 100 to 1A7 [U1-11 Inverse U1-11 Output of Function], U1-11 does not show the status in inverse.
bit0 : Terminal MA/MB-MC
bit1 : Terminal P1-C1
bit2 : Terminal P2-C2
bit3 : Not used (normal value of [ ]).
bit4 : Not used (normal value of [ ]).
bit5 : Not used (normal value of [ ]).
bit6 : Not used (normal value of [ ]).
bit7 : Not used (normal value of [ ]).
Shows drive status where = ON and = OFF.
No signal output available
No signal output available
No signal output available
U1-13
(004E)
U1-14
(004F)
U1-16
(0053)
U1-18
(0061)
Terminal A1 Level
Terminal A2 Level
SFS Output Frequency
oPE Fault Parameter
For example, U1-12 shows during run with the Reverse Run command.
bit0 : During Run
bit1 : During zero-speed
bit2 : During reverse
bit3 : During fault reset signal input
bit4 : During speed agreement
bit5 : Drive Ready
bit6 : During minor fault detection
bit7 : During fault detection
Shows the signal level of terminal A1.
Unit: 0.1%
Shows the signal level of terminal A2.
Unit: 0.1%
Shows the output frequency after soft start. Shows the frequency with acceleration and deceleration times and S-curves. Parameter o1-03 [Keypad Display Unit Selection] sets the display units.
Unit: 0.01 Hz
Shows the parameter number that caused the oPE02 [Parameter Range Setting Error] or oPE08 [Parameter Selection Error].
10 V = 100% (0 V to +10 V)
10 V = 100% (0 V to +10 V)
10 V = Maximum frequency
(0 V to +10 V)
No signal output available
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 95
1.17 U: Monitors
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
U1-19
(0066)
U1-24
(007D)
U1-25
(004D)
U1-26
(005B)
U1-50
(1199)
Expert
U1-91
(154E)
Expert
Name Description MFAO Signal Level
MEMOBUS/Modbus Error Code
Input Pulse Monitor
Software number
SoftwareNumber ROM
Virtual Analog Input
Output Voltage
Shows the contents of the MEMOBUS/Modbus communication error where =errorand = no error.
For example, U1-19 shows when the drive detects a CRC error.
bit0 : CRC Error
bit1 : Data Length Error
bit2 : Not used (normal value of [ ]).
bit3 : Parity Error
bit4 : Overrun Error
bit5 : Framing Error
bit6 : Timed Out
bit7 : Not used (normal value of [ ]).
Shows the frequency to pulse train input terminal RP.
Unit: 1 Hz
Shows the ID.
Shows the ROM ID.
Shows the virtual analog input value.
Shows the drive internal output voltage reference.
Unit: 0.1 V
No signal output available
Determined by H6-02
No signal output available
No signal output available
Determined by H7-40
200 V class: 10 V = 200
Vrms
400 V class: 10 V = 400
Vrms

U2: Fault Trace

No.
(Hex.)
U2-01
(0080)
U2-02
(0081)
U2-03
(0082)
U2-04
(0083)
U2-05
(0084)
U2-06
(0085)
Current Fault
Previous Fault
Freq Reference@Fault
Output Freq @ Fault
Output Current@Fault
Motor Speed @ Fault
Name Description MFAO Signal Level
Shows the fault that the drive has when viewing the monitor.
Shows the fault that occurred most recently.
Shows the frequency reference at the fault that occurred most recently.
Use U1-01 [Frequency Reference] to monitor the frequency reference value.
Unit: 0.01 Hz
Shows the output frequency at the fault that occurred most recently.
Use U1-02 [Output Frequency] to monitor the actual output frequency.
Unit: 0.01 Hz
Shows the output current at the fault that occurred most recently.
Use U1-03 [Output Current] to monitor the actual output current. The keypad shows the value of U1- 03 in amperes (A).
When looking at the monitor through MEMOBUS/Modbus communications, the current is 8192 = drive rated current (A). Calculate the current from the monitor value that is in at MEMOBUS/ Modbus communications using Numerals being displayed / 8192 × drive rated current (A).
Unit: When the drive model changes, the display units for this parameter also change.
0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
0.1A units: 2056 - 2082, 4031 - 4060
Shows the motor speed at the fault that occurred most recently.
Use U1-05 [Motor Speed] to monitor the motor speed.
Unit: 0.01 Hz
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
96 YASKAWA TOEPYAIGA5002A GA500 Programming
1.17 U: Monitors
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
U2-07
(0086)
U2-08
(0087)
U2-09
(0088)
U2-10
(0089)
U2-11
(008A)
U2-12
(008B)
Name Description MFAO Signal Level
Output Voltage@Fault
DC Bus Voltage@Fault
Output Power @ Fault
Torque Ref @ Fault
Input Terminal Status @ Fault
Output Terminal Status @ Fault
Shows the output voltage reference at the fault that occurred most recently.
Use U1-06 [Output Voltage Ref] to monitor the output voltage reference.
Unit: 0.1 V
Shows the DC bus voltage at the fault that occurred most recently.
Use U1-07 [DC Bus Voltage] to monitor the DC bus voltage.
Unit: 1 V
Shows the output power at the fault that occurred most recently.
Use U1-08 [Output Power] to monitor the output power.
Unit: 0.1 kW
Shows the torque reference at the fault that occurred most recently as a percentage of the motor rated torque.
Use U1-09 [Torque Reference] to monitor the torque reference.
Unit: 0.1%
Shows the status of the MFDI terminals at the most recent fault where = ON and = OFF.
For example, U2-11 shows when terminals S1 and S3 are ON.
Use U1-10 [Input Terminal Status] to monitor the actual MFDI terminal status.
bit0 : Terminal S1
bit1 : Terminal S2
bit2 : Terminal S3
bit3 : Terminal S4
bit4 : Terminal S5
bit5 : Terminal S6
bit6 : Terminal S7
bit7 : Not used (normal value of [ ]).
Shows the status of the MFDO terminals at the most recent fault where = ON and = OFF.
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
U2-13
(008C)
Operation Status @ Fault
For example, U2-12 shows when terminals MA and P2 are ON.
Use U1-11 [Output Terminal Status] to monitor the actual MFDO terminal status.
bit0 : Terminal MA/MB-MC
bit1 : Terminal P1-C1
bit2 : Terminal P2-C2
bit3 : Not used (normal value of [ ]).
bit4 : Not used (normal value of [ ]).
bit5 : Not used (normal value of [ ]).
bit6 : Not used (normal value of [ ]).
bit7 : Not used (normal value of [ ]).
Shows the status of the MFDO terminals at the most recent fault where = ON and = OFF.
For example, U2-13 shows during run.
Use U1-12 [Drive Status] to monitor the actual MFDO terminal status.
bit0 : During Run
bit1 : During zero-speed
bit2 : During reverse
bit3 : During fault reset signal input
bit4 : During speed agreement
bit5 : Drive Ready
bit6 : During minor fault detection
bit7 : During fault detection
No signal output available
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 97
1.17 U: Monitors
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
U2-14
(008D)
U2-15
(07E0)
U2-16
(07E1)
U2-17
(07E2)
U2-19
(07E4)
U2-20
(008E)
U2-21
(1166)
Expert
Name Description MFAO Signal Level
Elapsed Time @ Fault
SFS Output @ Fault
q-Axis Current@Fault
d-Axis Current@Fault
ControlDeviation@Flt
Heatsink Temp @Fault
STPo Detect @ Fault
Shows the cumulative operation time of the drive at the fault that occurred most recently.
No signal output available
Use U4-01 [Cumulative Ope Time] to monitor the cumulative operation time.
Unit: 1 h
No signal output available
Shows the output frequency after soft start at the fault that occurred most recently.
Use U1-16 [SFS Output Frequency] to monitor the output frequency after soft start.
Unit: 0.01 Hz
No signal output available
Shows the q-Axis current of the motor at the fault that occurred most recently.
Use U6-01 [Iq Secondary Current] to monitor the q-Axis current of the motor.
Unit: 0.1 %
No signal output available
Shows the d-Axis current of the motor at the fault that occurred most recently.
Use U6-02 [Id ExcitationCurrent] to monitor the d-Axis current of the motor.
Unit: 0.1 %
No signal output available
Shows the amount of control axis deviation (Δθ) at the fault that occurred most recently.
Use U6-10 [ContAxisDeviation Δθ] to monitor the actual amount of control axis deviation (Δθ).
Unit: 0.1 °
No signal output available
Shows the heatsink temperature at the fault that occurred most recently.
Use U4-08 [Heatsink Temperature] to monitor the temperature of the heatsink.
Unit: 1 °C
No signal output available
Monitors conditions to detect STPo [Motor Step-Out Detected] faults. The bit for each condition is
shown as = ON or = OFF.

U3: Fault History

No.
(Hex.)
U3-01 to U3-04
(0090 - 0093)
(0800 - 0803)
U3-05 to U3-10
(0804 - 0809)
U3-11 to U3-14
(0094 - 0097)
(080A - 080D)
U3-15 to U3-20
(080E - 0813)
1st to 4th MostRecent Fault
5th to 10th MostRecent Fault
ElapsedTime@1st to 4thFault
ElapsedTime@5th to 10thFault
Name Description MFAO Signal Level
For example, U2-21 shows when the drive detects excessive current.
bit0 : Excessive current
bit1 : Induced voltage deviation
bit2 : d-axis current deviation
bit3 : Motor lock at startup
bit4 : Acceleration stall continue
bit5 : Acceleration stall repeat
bit6 : Not used (normal value of [ ]).
bit7 : Not used (normal value of [ ]).
Shows the fault history of the first to fourth most recent faults.
Note:
The drive saves the U3-01 to U3-04 [1st to 4th MostRecent Fault] fault histories to two types of registers at the same time for the MEMOBUS/Modbus communications.
Shows the fault history of the fifth to tenth most recent faults.
Shows the cumulative operation time when the first to fourth most recent faults occurred.
Unit: 1 h
Note:
The drive saves the U3-11 to U3-14 [ElapsedTime@1st to 4thFault] the cumulative operation time to two types of registers at the same time for the MEMOBUS/Modbus communications.
Shows the cumulative operation time when the fifth to tenth most recent faults occurred.
Unit: 1 h
No signal output available
No signal output available
No signal output available
No signal output available
98 YASKAWA TOEPYAIGA5002A GA500 Programming

U4: Maintenance Monitors

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.17 U: Monitors
No.
(Hex.)
U4-01
(004C)
U4-02
(0075)
U4-03
(0067)
U4-04
(007E)
U4-05
(007C)
U4-06
(07D6)
U4-07
(07D7)
U4-08
(0068)
Name Description MFAO Signal Level
Cumulative Ope Time
Num of Run Commands
Cooling Fan Ope Time
Cool Fan Maintenance
CapacitorMaintenance
PreChargeRelayMainte
IGBT Maintenance
Heatsink Temperature
Shows the cumulative operation time of the drive.
Use parameter o4-01 [Elapsed Operating Time Setting] to reset this monitor. Use parameter o4-02 [Elapsed Operating Time Selection] to select the cumulative operation times from:
The time from when the drive is energized until it is de-energized.
The time at which the Run command is turned ON.
The maximum value that the monitor will show is 99999. After this value is more than 99999, the drive automatically resets it and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 0099H for data in 1 h units.
Shows how many times that the drive has received a Run command.
Use parameter o4-13 [RUN Command Counter @ Initialize] to reset this monitor. The maximum value that the monitor will show is 65535. After this value is more than 65535, the drive automatically resets it and starts to count from 0 again.
Unit: 1
Shows the cumulative operation time of the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor. The maximum value that the monitor will show is 99999. After this value is more than 99999, the drive automatically resets it and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 009BH for data in 1 h units.
Shows the cumulative operation time of the cooling fans as a percentage of the replacement life of the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor.
Unit: 1%
Note:
Replace the cooling fans when this monitor is 90%.
Shows the operation time of the electrolytic capacitors for the main circuit and control circuit as a percentage of the replacement life of the electrolytic capacitors.
Use parameter o4-05 [Capacitor Maintenance Setting] to reset this monitor.
Unit: 1%
Note:
Replace the electrolytic capacitor when this monitor is 90%.
Shows the operation time of the soft charge bypass relay as a percentage of the replacement life of the soft charge bypass relay.
Use parameter o4-07 [Softcharge Relay Maintenance Set] to reset this monitor.
Unit: 1%
Note:
Replace the drive when this monitor is 90%.
Shows the operation time of the IGBTs as a percentage of the replacement life of the IGBTs.
Set parameter o4-09 [IGBT Maintenance Setting] to reset this monitor.
Unit: 1%
Note:
Replace the drive when this monitor is 90%.
Shows the heatsink temperature of the drive.
Unit: 1 °C
10 V: 99999 h
10 V: 65535 times
10 V: 99999 h
10 V: 100%
10 V: 100%
10 V: 100%
10 V: 100%
10 V: 100 °C
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 99
1.17 U: Monitors
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
U4-09
(005E)
U4-10
(005C)
U4-11
(005D)
U4-13
(07CF)
U4-14
(07D0)
U4-16
(07D8)
U4-18
(07DA)
Name Description MFAO Signal Level
LED Check
kWh, Lower 4 Digits
kWh, Upper 5 Digits
Peak Hold Current
PeakHold Output Freq
Motor oL1 Level
Reference Source
Turns on all of the keypad LEDs to make sure that the LEDs operate correctly.
1. With U4-09 displayed, press . All LEDs on the keypad will turn on.
Note:
When Safety input 2 CH is open (STo), READY will flash.
Shows the lower 4 digits of the watt hour value for the drive.
Unit: 1 kWh
Note:
The watt hour is displayed in 9 digits. Monitor U4-11 [kWh, Upper 5 Digits] shows the upper 5 digits and U4-10 shows the lower 4 digits.
Example for 12345678.9 kWh:
U4-10: 678.9 kWh
U4-11: 12345 MWh
Shows the upper 5 digits of the watt hour value for the drive.
Unit: 1 MWh
Note:
Monitor U4-11 shows the upper 5 digits and U4-10 [kWh, Lower 4 Digits] shows the lower 4 digits.
Example for 12345678.9 kWh:
U4-10: 678.9 kWh
U4-11: 12345 MWh
Shows the hold value of the peak value (rms) for the drive output current.
Use U4-14 [PeakHold Output Freq] to show the drive output frequency at the time that the drive holds the output current.
The drive will hold the peak hold current at the next start up and restart of the power supply. The drive keeps the value that was under hold during baseblock (during stop).
The keypad shows the value of U4-13 in amperes (A). When looking at the monitor through MEMOBUS/Modbus communications, the current is 8192 = drive rated current (A). Calculate the current from the monitor value that is in at MEMOBUS/Modbus communications using Numerals being displayed / 8192 × drive rated current (A).
Unit: When the drive model changes, the display units for this parameter also change.
0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
0.1A units: 2056 - 2082, 4031 - 4060
Shows the output frequency at which the peak value (rms) of the drive output current is held.
The peak hold current can be monitored by U4-13 [Peak Hold Current].
The peak hold output frequency will be cleared at the next startup and restart of the power supply. The drive keeps the value that was under hold during baseblock (during stop).
Unit: 0.01 Hz
Shows the integrated value of oL1 [Motor Overload] as a percentage of oL1 detection level.
Unit: 0.1%
Shows the selected frequency reference source. The keypad shows the frequency reference source as XY-nnas specified by these rules:
X: External Reference 1/2 Selection [H1-xx = 2] selection status
1: b1-01 [Frequency Reference Selection 1]
2: b1-15 [Frequency Reference Selection 2]
Y-nn: Frequency reference source
0-01: Keypad (d1-01 [Reference 1])
1-00: Analog input (unassigned)
1-01: MFAI terminal A1
1-02: MFAI terminal A2
2-02 to 2-17: Multi-step speed reference (d1-02 to d1-17 [Reference 2 to 16, Jog Reference])
3-01: MEMOBUS/Modbus communications
4-01: Communication option card
5-01: Pulse train input
7-01: DriveWorksEZ
9-01: Up/Down command
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
10 V: 100%
No signal output available
100 YASKAWA TOEPYAIGA5002A GA500 Programming
Loading...