Yaskawa GA500 Programming Manual

GA500
Industrial AC Microdrive
Programming
Catalog Code:
GA50Uxxxxxxxx
240 V Single-Phase Input: 1/6 to 5 HP 240 V Three-Phase Input: 1/6 to 30 HP 480 V Three-Phase Input: 1/2 to 40 HP
2 YASKAWA TOEPYAIGA5002A GA500 Programming

Table of Contents

1. Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.2 How to Read the Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Icons and Terms that Identify Parameters and Control Modes . . . . . . . . . . . . . . . . . . . . . .11
1.3 Parameter Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.4 A: Initialization Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A1: Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A2: User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.5 b: Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
b1: Operation Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
b2: DC Injection Braking and Short Circuit Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
b3: Speed Search. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
b4: Timer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
b5: PID control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
b6: Dwell Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
b8: Energy Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.6 C: Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C1: Accel & Decel Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C2: S-Curve Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C3: Slip Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
C4: Torque Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
C5: Automatic Speed Regulator (ASR: Automatic Speed Regulator) . . . . . . . . . . . . . . . 27
C6: Duty & Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1.7 d: Reference Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
d1: Frequency Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
d2: Reference Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
d3: Jump Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
d4: Frequency Ref Up/Down & Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
d6: Field Weakening /Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
d7: Offset Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
1.8 E: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
E1: V/f Pattern for Motor 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
E2: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
E3: V/f Pattern for Motor 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
E4: Motor 2 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
E5: PM Motor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
E9: Motor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.9 F: Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
F1: Fault Detection in PG Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
F6: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
YASKAWA TOEPYAIGA5002A GA500 Programming 3
F7: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
1.10 H: Terminal Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
H1: Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
H2: Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
H3: Analog Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
H4: Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
H5: Modbus Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
H6: Pulse Train Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
H7: Virtual MFIO selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1.11 L: Protection Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
L1: Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
L2: Power Loss Ride Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
L3: Stall Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
L4: Speed Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
L5: Fault Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
L6: Torque Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
L7: Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
L8: Drive Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
1.12 n: Special Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n1: Hunting Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n2: Auto Freq Regulator (AFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n3: High Slip/Overexcite Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
n5: Feed Forward Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
n6: Online Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
n7: EZ Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
n8: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
nA: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
1.13 o: Keypad-Related Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
o1: Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
o2: Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
o3: Copy Keypad Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
o4: Maintenance Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
o5: Log Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1.14 q: DriveWorksEZ Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
q1-01 to qx-xx: Reserved for DriveWorksEZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
1.15 r: DWEZ Connection 1-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
r1-01 to r1-40: DriveWorksEZ Connection Parameters 1 to 20 (Upper / Lower) . . . . . . . . . . . 90
1.16 T: Motor Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T0: Tuning Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T1: Induction Motor Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
T2: PM Motor Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
T3: ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
T4: EZ Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
1.17 U: Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
U1: Operation Status Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
U2: Fault Trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
U3: Fault History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
U4: Maintenance Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
U5: PID Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
U6: Operation Status Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
U8: DriveWorksEZ Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
1.18 Parameters that Change from the Default Settings with A1-02 [Control Method
Selection]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
4 YASKAWA TOEPYAIGA5002A GA500 Programming
1.19 Parameters that Change from the Default Settings with E3-01 [Motor 2 Control
Mode Selection] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
1.20 Parameters Changed by E1-03 [V/f Pattern Selection] . . . . . . . . . . . . . . . . . . . . . . . 113
1.21 Defaults by Drive Model and Duty Rating ND/HD. . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Single-Phase 200 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Three-Phase 200 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Three-Phase 400 V Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
1.22 Parameters Changed by PM Motor Code Selection. . . . . . . . . . . . . . . . . . . . . . . . . . 127
Yaskawa SMRA Series SPM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Yaskawa SMRD Series SPM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Yaskawa SSR1 Series IPM Motors (Derated Torque) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
2. Parameter Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
2.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
2.2 A: Initialization Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
A1: Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
A2: User Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
2.3 b: Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
b1: Operation Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
b2: DC Injection Braking and Short Circuit Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
b3: Speed Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
b4: Timer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
b5: PID control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
b6: Dwell Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
b8: Energy Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
2.4 C: Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
C1: Accel & Decel Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
C2: S-Curve Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
C3: Slip Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
C4: Torque Compensation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
C5: Auto Speed Regulator (ASR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
C6: Duty & Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
2.5 d: References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
d1: Frequency Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
d2: Reference Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
d3: Jump Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
d4: Frequency Ref Up/Down & Hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
d6: Field Weakening /Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
d7: Offset Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
2.6 E: Motor Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
E1: V/f Pattern for Motor 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
E2: Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
E3: V/f Pattern for Motor 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
E4: Motor 2 Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
E5: PM Motor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
E9: Motor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
2.7 F: Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
F1: Fault Detection in PG Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
F6, F7: Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
2.8 H: Terminal Function Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
H1: Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
MFDI Setting Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
YASKAWA TOEPYAIGA5002A GA500 Programming 5
H2: Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
H2 MFDO Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
MFDO Setting Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
H3: Analog Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
H3: MFAI Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
Multi-Function Analog Input Terminal Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
H4: Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
H5: Memobus/Modbus Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
H6: Pulse Train Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
H7: Virtual MFIO Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
2.9 L: Protection Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
L1: Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
L2: Power Loss Ride Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
L3: Stall Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
L4: Speed Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
L5: Fault Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
L6: Torque Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
L7: Torque Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
L8: Drive Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
2.10 n: Special Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
n1: Hunting Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
n2: Auto Freq Regulator (AFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
n3: High Slip Braking (HSB) and Overexcitation Braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
n5: Feed Forward Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
n6: Online Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
n7: EZ Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
n8: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
nA: PM Motor Control Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425
2.11 o: Keypad-Related Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
o1: Keypad Display Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
o2: Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
o3: Copy Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
o4: Maintenance Mon Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
o5: Log Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
2.12 T: Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T0: Tuning Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T1: Induction Motor Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
T2: PM Motor Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
T3: ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
T4: EZ Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
3. Startup Procedure and Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
3.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
3.2 Overview of Keypad Components and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
Indicator flashing statuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460
Keypad Mode and Menu Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461
Set up the Drive with General-Purpose Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462
Programming Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
Change Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
Verify and Set the Changed Parameters (Verify Menu). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
How to Switch between LOCAL and REMOTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
3.3 Keypad Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Digital character mapping table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
6 YASKAWA TOEPYAIGA5002A GA500 Programming
Show the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Check Modified Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Set and View Necessary Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
Change Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
Save a Backup of Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
Write Backed-up Parameters to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
Verify Keypad Parameters and Drive Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
Delete Parameters Backed Up to the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
3.4 Automatic Parameter Settings Optimized for Specific Applications (Application
Presets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471
3.5 Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
Auto-Tuning for Induction Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
Auto-Tuning for PM Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
Auto-Tuning in EZ Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474
ASR and Inertia Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
Precautions before Auto-Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476
3.6 Test Run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
No-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Do a No-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Actual-Load Test Run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Do an Actual-Load Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
3.7 Fine Tuning during Test Runs (Adjust the Control Function) . . . . . . . . . . . . . . . . . . . 481
V/f Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 481
Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
Open Loop Vector Control for PM Motors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483
Advanced Open Loop Vector Control Method for PM Motors . . . . . . . . . . . . . . . . . . . . . . . . . 484
EZ Open Loop Vector Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485
3.8 Test Run Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486
4. Mechanical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 489
4.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
4.2 Removing/Reattaching Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
Remove the Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
Reattach the Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
4.3 Remove and Reattach the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
Remove the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
Reattach the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
5. Electrical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495
5.1 Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496
5.2 Standard Connection Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
5.3 Main Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
Motor and Main Circuit Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
Main Circuit Terminal Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
5.4 Control Circuit Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
Control Circuit Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
Control Circuit Terminal Block Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
Control Circuit Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
Switches and Jumpers on the Terminal Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
5.5 Control I/O Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
Pulse Train Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
YASKAWA TOEPYAIGA5002A GA500 Programming 7
Set Sinking Mode/Sourcing Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511
Set the Input Signal for the MFAI Terminal A2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511
Set the Output Signal for the MFAO Terminal AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512
Switch ON Termination Resistor for MEMOBUS/Modbus Communications . . . . . . . . . . . . . 512
5.6 Connect the Drive to a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513
6. Preface and General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515
6.1 Receiving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
About Registered Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
6.2 Using the Product Safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Explanation of Signal Words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Section Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524
8 YASKAWA TOEPYAIGA5002A GA500 Programming
1

Parameter List

1.1 Section Safety ........................................................................................................... 10
1.2 How to Read the Parameter List ........................................................................... 11
1.3 Parameter Groups....................................................................................................12
1.4 A: Initialization Parameters....................................................................................13
1.5 b: Application ............................................................................................................ 15
1.6 C: Tuning .................................................................................................................... 25
1.7 d: Reference Settings..............................................................................................30
1.8 E: Motor Parameters ................................................................................................34
1.9 F: Options...................................................................................................................39
1.10 H: Terminal Functions .............................................................................................49
1.11 L: Protection Functions ..........................................................................................67
1.12 n: Special Adjustment.............................................................................................77
1.13 o: Keypad-Related Settings...................................................................................83
1.14 q: DriveWorksEZ Parameters ................................................................................89
1.15 r: DWEZ Connection 1-20 ....................................................................................... 90
1.16 T: Motor Tuning .........................................................................................................91
1.17 U: Monitors.................................................................................................................94
1.18 Parameters that Change from the Default Settings with A1-02 [Control
Method Selection] ..................................................................................................108
1.19 Parameters that Change from the Default Settings with E3-01 [Motor 2
Control Mode Selection].......................................................................................112
1.20 Parameters Changed by E1-03 [V/f Pattern Selection] .................................113
1.21 Defaults by Drive Model and Duty Rating ND/HD...........................................114
1.22 Parameters Changed by PM Motor Code Selection ......................................127
YASKAWA TOEPYAIGA5002A GA500 Programming 9

1.1 Section Safety

1.1 Section Safety
DANGER
Do not ignore the safety messages in this manual.
If you ignore the safety messages in this manual, it will cause serious injury or death. The manufacturer is not responsible for injuries or damage to equipment.
10 YASKAWA TOEPYAIGA5002A GA500 Programming

1.2 How to Read the Parameter List

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.2 How to Read the Parameter List

Icons and Terms that Identify Parameters and Control Modes

Icon Description
The parameter is available when operating the drive with V/f Control.
The parameter is available when operating the drive with Open Loop Vector Control.
The parameter is available when operating the drive with Open Loop Vector Control for PM.
The parameter is available when operating the drive with Advanced Open Loop Vector Control for PM.
The parameter is available when operating the drive with EZ Open Loop Vector Control.
Hex. Hexadecimal numbers that represent MEMOBUS addresses to change parameters over network communication.
RUN The parameter can be changed settings during run.
Expert The parameter that is available in Expert Mode only.
*1 Set A1-01 = 3 [Access Level Selection = Expert Level] to display and set Expert Mode parameters on the keypad.
Note:
Gray icons identify parameters that are not available in the specified control method.
*1
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 11

1.3 Parameter Groups

1.3 Parameter Groups
Represents the type of product parameters.
Parameter Name
A1 Initialization
A2 User Parameters
b1 Operation Mode Selection
b2 DC Injection Braking and Short Circuit Braking
b3 Speed Search
b4 Timer Function
b5 PID control
b6 Dwell Function
b8 Energy Saving
C1 Accel & Decel Time
C2 S-Curve Characteristics
C3 Slip Compensation
C4 Torque Compensation
C5
C6 Carrier Frequency
d1 Frequency Reference
d2 Reference Limits
d3 Jump Frequency
d4 Frequency Ref Up/Down & Hold
d6 Field Weakening /Forcing
d7 Offset Frequency
E1 V/f Pattern for Motor 1
E2 Motor Parameters
E3 V/f Pattern for Motor 2
E4 Motor 2 Parameters
E5 PM Motor Settings
E9 Motor Setting
F1 Fault Detection during PG Speed Control
F6 Communication Options
F7 Communication Options
H1 Digital Inputs
H2 Digital Outputs
H3 Analog Inputs
H4 Analog Outputs
H5 Modbus Communication
H6 Pulse Train Input/Output
Automatic Speed Regulator (ASR: Automatic Speed Regulator)
Parameter Name
H7 Virtual MFIO selection
L1 Motor Protection
L2 Power Loss Ride Through
L3 Stall Prevention
L4 Speed Detection
L5 Fault Restart
L6 Torque Detection
L7 Torque Limit
L8 Drive Protection
n1 Hunting Prevention
n2 Auto Freq Regulator (AFR)
n3 High Slip/Overexcite Braking
n5 Feed Forward Control
n6 Online Tuning
n7 EZ Drive
n8 PM Motor Control Tuning
nA PM Motor Control Tuning
o1 Keypad Display
o2 Keypad Operation
o3 Copy Keypad Function
o4 Maintenance Monitors
o5 Log Function
q DriveWorksEZ Parameters
r DWEZ Connection 1-20
T0 Tuning Mode Selection
T1 Induction Motor Auto-Tuning
T2 PM Motor Auto-Tuning
T3 ASR and Inertia Tuning
T4 EZ Tuning
U1 Operation Status Monitors
U2 Fault Trace
U3 Fault History
U4 Maintenance Monitors
U5 PID Monitors
U6 Operation Status Monitors
U8 DriveWorksEZ Monitors
12 YASKAWA TOEPYAIGA5002A GA500 Programming
1.4 A: Initialization Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

A1: Initialization

1.4 A: Initialization Parameters

No.
(Hex.)
A1-00
(0100)
RUN
A1-01
(0101)
RUN
A1-02
(0102)
A1-03
(0103)
A1-04
(0104)
A1-05
(0105)
A1-06
(0127)
Name Description
Language Selection
Sets the language for the LCD keypad.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not reset this parameter.
0 : English
1 : Japanese
2 : German
3 : French
4 : Italian
5 : Spanish
6 : Portuguese
7 : Chinese
8 : Czech
9 : Russian
10 : Turkish
11 : Polish
12 : Greek
Access Level Selection
Sets user access to parameters. The access level controls which parameters the keypad will display, and which parameters the user can set.
0 : Operation Only
1 : User Parameters
2 : Advanced Level
3 : Expert Level
Control Method Selection
Sets the control method for the drive application and the motor.
0 : V/f Control
2 : Open Loop Vector
5 : PM Open Loop Vector
6 : PM Advanced Open Loop Vector
8 : EZ Vector Control
Initialize Parameters
Sets parameters to default values.
0 : No Initialization
1110 : User Initialization
2220 : 2-Wire Initialization
3330 : 3-Wire Initialization
Password
Entry point for the password set in A1-05 [Password Setting]. The user can view the settings of parameters that are locked without entering the password. Enter the correct password in this parameter to change parameter settings.
Password Setting
Set the password to lock parameters and prevent changes to parameter settings. Enter the correct password in A1-04 [Password] to unlock parameters and accept changes.
Application Preset
Sets the drive to operate in selected application conditions.
0 : General-purpose
1 : Water Supply Pump 2
2 : Conveyor
3 : Exhaust Fan
4 : HVAC Fan
5 : Air Compressor
8 : Conveyor 2
Default
(Range)
0
(0 - 12)
2
(0 - 3)
2
(0, 2, 5, 6, 8)
0
(0 - 3330)
0000
(0000 - 9999)
0000
(0000 - 9999)
0
(0 - 5, 8)
Ref.
139
139
140
141
142
143
143
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 13
1.4 A: Initialization Parameters
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
A1-07
(0128)
Name Description
DriveWorksEZ Function Selection
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive firmware.
0 : Disabled
1 : Enabled
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.

A2: User Parameters

No.
(Hex.)
A2-01 to A2-32
(0106 - 0125)
A2-33
(0126)
Name Description
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and save the values to parameters A2-01 to A2-32. Use Setup Mode to show the saved parameters. You can immediately access these saved parameters.
User Parameter Auto Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to 32].
0 : Disabled: Manual Entry Required
1 : Enabled: Auto Save Recent Parms
Note:
When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.
Default
(Range)
0
(0 - 2)
0
(0, 1)
-
(0000 - 9999)
Default
(Range)
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Determined by A1-06
(0, 1)
Ref.
156
156
156
Ref.
157
157
14 YASKAWA TOEPYAIGA5002A GA500 Programming
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

b1: Operation Mode Selection

1.5 b: Application

No.
(Hex.)
b1-01
(0180)
b1-02
(0181)
b1-03
(0182)
b1-04
(0183)
b1-06
(0185)
b1-07
(0186)
b1-08
(0187)
b1-14
(01C3)
b1-15
(01C4)
Name Description
Frequency Reference Selection 1
Sets the input method for the frequency reference.
0 : Keypad
1 : Analog Input
2 : Memobus/Modbus Communications
3 : Option PCB
4 : Pulse Train Input
Run Command Selection 1
Sets the input method for the Run command.
0 : Keypad
1 : Digital Input
2 : Memobus/Modbus Communications
3 : Option PCB
Stopping Method Selection
Sets the method to stop the motor after removing a Run command or entering a Stop command.
Note:
When A1-02 = 5, 6, 8 [Control Method Selection = OLV/PM, AOLV/PM, EZOLV], the setting range is 0, 1, 3.
0 : Ramp to Stop
1 : Coast to Stop
2 : DC Injection Braking to Stop
3 : Coast to Stop with Timer
Reverse Operation Selection
Sets the reverse operation function. Disable reverse operation in fan or pump applications where reverse rotation is dangerous.
0 : Reverse Enabled
1 : Reverse Disabled
Digital Input Reading
Sets the number of times that the drive reads the sequence input command to prevent malfunction because of electrical interference.
0 : Single Scan
1 : Double Scan
LOCAL/REMOTE Run Selection
Sets drive response to an existing Run command when the drive receives a second Run command from a different location.
0 : Disregard Existing RUN Command
1 : Accept Existing RUN Command
Run Command Select in PRG Mode
Sets the conditions for the drive to accept a Run command entered from an external source when using the keypad to set parameters.
0 : Disregard RUN while Programming
1 : Accept RUN while Programming
2 : Allow Programming Only at Stop
Phase Order Selection
Sets the phase order for output terminals U/T1, V/T2, and W/T3. This parameter can align the Forward Run command from the drive and the forward direction of the motor without changing wiring.
0 : Standard
1 : Switch Phase Order
Frequency Reference Selection 2
Sets the input method for frequency reference 2.
0 : Keypad
1 : Analog Input
2 : Memobus/Modbus Communications
3 : Option PCB
4 : Pulse Train Input
Default
(Setting Range)
1
(0 - 4)
1
(0 - 3)
0
(0 - 3)
0
(0, 1)
1
(0, 1)
0
(0, 1)
0
(0 - 2)
0
(0, 1)
0
(0 - 4)
Ref.
158
160
160
163
163
164
164
Parameter List
165
1
165
YASKAWA TOEPYAIGA5002A GA500 Programming 15
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b1-16
(01C5)
Name Description
Run Command Selection 2
Sets the input method for Run Command 2 when the user switches the control circuit terminals ON/OFF to change the Run command source.
0 : Keypad
1 : Digital Input
2 : Memobus/Modbus Communications
3 : Option PCB
b1-17
(01C6)
Run Command at Power Up
Sets drive response when energizing a drive that has an external Run command. Set this parameter in applications where energizing or de-energizing the drive enables the Run command.
0 : Disregard Existing RUN Command
1 : Accept Existing RUN Command
b1-35
(1117)
Digital Input Deadband Time
Sets the deadband time for MFDIs.
Expert

b2: DC Injection Braking and Short Circuit Braking

No.
(Hex.)
b2-01
(0189)
b2-02
(018A)
b2-03
(018B)
b2-04
(018C)
b2-08
(0190)
b2-12
(01BA)
b2-13
(01BB)
b2-18
(0177)
Name Description
DC Injection/Zero SpeedThreshold
Sets the frequency to start DC Injection Braking or Short Circuit Braking.
Note:
This parameter is available when b1-03 = 0 [Stopping Method Selection = Ramp to Stop].
DC Injection Braking Current
DC Inject Braking Time at Start
DC Inject Braking Time at Stop
Magnetic Flux Compensation Value
Short Circuit Brake Time @ Start
Short Circuit Brake Time @ Stop
Short Circuit Braking Current
Sets the DC Injection Braking current as a percentage of the drive rated current.
Sets the DC Injection Braking Time at stop.
Sets the DC Injection Braking Time at stop.
Sets how much current the drive injects when DC Injection Braking at Start starts (Initial Excitation) as a percentage of E2-03 [Motor No-Load Current].
Sets the Short Circuit Braking time at start.
Sets the Short Circuit Braking time at stop.
Sets the Short Circuit Braking Current as a percentage of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
Default
(Setting Range)
0
(0 - 3)
0
(0, 1)
0.0 ms
(0.0 to 100.0 ms)
Default
(Range)
Determined by A1-02
(0.0 - 10.0 Hz)
50%
(0 - 75%)
0.00 s
(0.00 - 10.00 s)
Determined by A1-02
(0.00 - 10.00 s)
0%
(0 - 1000%)
0.00 s
(0.00 - 25.50 s)
A1-02 = 8: 0.00 s
Other than A1-02 = 8:
0.50 s
(0.00 - 25.50 s)
100.0%
(0.0 - 200.0%)
Ref.
167
167
168
Ref.
168
169
169
169
170
170
170
171

b3: Speed Search

No.
(Hex.)
b3-01
(0191)
b3-02
(0192)
16 YASKAWA TOEPYAIGA5002A GA500 Programming
Speed Search at Start Selection
SpeedSearch Deactivation Current
Name Description
Sets the Speed Search at Start function where the drive will perform Speed Search with each Run command.
0 : Disable
1 : Enabled
Sets the current level that stops Speed Search as a percentage of the drive rated output current. Usually it is not necessary to change this setting.
Default
(Range)
Determined by A1-02
(0, 1)
Determined by A1-02
(0 - 200%)
Ref.
174
175
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b3-03
(0193)
b3-04
(0194)
b3-05
(0195)
b3-06
(0196)
Expert
b3-07
(0197)
Expert
b3-08
(0198)
b3-09
(0199)
b3-10
(019A)
Expert
b3-14
(019E)
b3-17
(01F0)
Expert
b3-18
(01F1)
Expert
b3-19
(01F2)
b3-24
(01C0)
Name Description
Speed Search Deceleration Time
Sets the deceleration time during Speed Search operation. Set the length of time to decelerate from the maximum output frequency to the minimum output frequency.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this parameter takes effect only in Expert Mode.
V/f Gain during Speed Search
Sets the ratio used to reduce the V/f during searches to reduce the output current during speed searches.
Speed Search Delay Time
Sets the Speed Search delay time to activate a magnetic contactor installed between the drive and motor.
Speed Estimation Current Level 1
Speed Estimation Current Level 2
Speed Estimation ACR P Gain
Speed Estimation ACR I Time
Speed Estimation Detection Gain
Bi-directional Speed Search
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a coefficient of the motor rated current. Usually it is not necessary to change this setting.
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a coefficient of E2-03 [Motor No-Load Current] or E4-03 [Motor 2 Rated No-Load Current]. Usually it is not necessary to change this setting.
Sets the proportional gain for the automatic current regulator during Speed Estimation Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to change this setting.
Sets the integral time for the automatic current regulator during Speed Estimation Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to change this setting.
Sets the gain to correct estimated frequencies from Speed Estimation Speed Search.
Sets the direction of Speed Search to the direction of the frequency reference or in the motor rotation direction as detected by the drive.
0 : Disabled
1 : Enabled
Note:
When E9-01 = 0 [Motor Type Selection = Induction (IM)] and A1-02 = 0, 2, or 8
[Control Method Selection = V/f, OLV, or EZOLV], the default settings change when the setting of b3-24 [Speed Search Method Selection] changes.
b3-24 = 1 [Speed Estimation]: Refer to 108.b3-24 = 2 [Current Detection 2]: 0
When E9-01 = 1 or 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
and A1-02 = 0 or 8 [V/f, EZOLV], refer to 108.
When you set A1-02, b3-24, and E9-01, set b3-14.
Speed Est Retry Current Level
Speed Est Retry Detection Time
Speed Search Restart Attempts
Speed Search Method Selection
Sets the current level for the search retry function in Speed Estimation Speed Search as a percentage where drive rated current is a setting value of 100%.
Sets the length of time that the drive will wait to retry Speed Estimation Speed Search when too much current flow stopped the Speed Search.
Sets the number of times to restart Speed Search if Speed Search does not complete.
Sets the Speed Search method when you start the motor or when you restore power after a momentary power loss.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], the default setting changes
when the setting for E9-01 [Motor Type Selection] changes.
E9-01 = 0 [Induction (IM)]: 2E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]: 1
When you set b3-24, it will trigger the drive to initialize b3-14 [Bi-directional Speed
Search]. After you set b3-24, set b3-14.
1 : Speed Estimation
2 : Current Detection 2
Default
(Range)
2.0 s
(0.1 - 10.0 s)
Determined by o2-04
(10 - 100)
0.2 s
(0.0 - 100.0 s)
Determined by o2-04
(0.0 - 2.0)
1.0
(0.0 - 3.0)
Determined by A1-02 and
o2-04
(0.00 - 6.00)
Determined by A1-02
when A1-02 ≠ 5
20.0 when A1-02 = 5
(0.0 - 1000.0 ms)
1.05
(1.00 - 1.20)
Determined by A1-02 and
b3-24
(0, 1)
150%
(0 - 200%)
0.10 s
(0.00 - 1.00 s)
3 times
(0 - 10 times)
2
(1, 2)
Ref.
175
175
175
175
176
176
176
176
176
177
177
Parameter List
177
1
177
YASKAWA TOEPYAIGA5002A GA500 Programming 17
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b3-25
(01C8)
Expert
b3-26
(01C7)
Expert
b3-29
(077C)
Expert
b3-31
(0BC0)
Expert
b3-32
(0BC1)
Expert
b3-33
(0B3F)
Expert
b3-54
(3123)
b3-55
(3124)
Expert
b3-56
(3126)
b3-61
(1B96)
Expert
Name Description
Speed Search Wait Time
Sets the length of time the drive will wait to start the Speed Search Retry function.
Direction Determination Level
Speed Search Back-EMF Threshold
Spd Search Current Reference Lvl
Spd Search Current Complete Lvl
Speed Search during Uv Selection
Sets the level to find the motor rotation direction. Increase the value if the drive cannot find the direction.
Sets the induced voltage for motors that use Speed Search. The drive will start Speed Search when the motor induced voltage level is the same as the setting value. Usually it is not necessary to change this setting.
Sets the current level that decreases the output current during Current Detection Speed Search.
Sets the current level that completes Speed Search.
Sets the function that starts Speed Search at start-up if the drive detects a Uv [Undervoltage] when it receives a Run command.
0 : Disabled
1 : Enabled
Search Time
Sets the length of time that the drive will run Speed Search.
Current Increment Time
Sets the length of time that the drive will increase the current from zero current to the setting value of b3-06 [Speed Estimation Current Level 1].
InverseRotationSearch WaitTime
Initial Pole Detection Response Gain
Sets the wait time until the drive starts inverse rotation search after it completes forward search when you do inverse rotation search during Current Detection Speed Search.
Sets the responsiveness for initial motor magnetic pole calculation when A1-02 = 6 [Control Method Selection = AOLV/PM]. Set b3-61 > 0.0 for an ordinary IPM motor.
It is automatically set if High Frequency Injection Tuning is used.
Note:
Set n8-35 = 1 [Initial Pole Calculation Method = High Frequency Injection] to
enable this parameter.
Set n8-41 [HFI P Gain] to adjust the responsiveness for initial motor magnetic pole
calculation when A1-02 = 5 [OLV/PM].
Default
(Range)
0.5 s
(0.0 - 30.0 s)
1000
(40 to 60000)
10%
(0 - 10%)
1.50
(1.50 - 3.50)
1.20
(0.00 - 1.49)
1
(0, 1)
400 ms
(10 - 2000 ms)
10 ms
(10 - 2000 ms)
Determined by o2-04
(0.1 - 5.0 s)
5.0
(-20.0 - +20.0)
Ref.
178
178
178
178
178
179
179
179
179
179

b4: Timer Function

No.
(Hex.)
b4-01
(01A3)
b4-02
(01A4)
b4-03
(0B30)
Expert
b4-04
(0B31)
Name Description
Timer Function ON­Delay Time
Timer Function OFF­Delay Time
Terminal M1-M2 ON­Delay Time
Terminal M1-M2 OFF­Delay Time
Sets the ON-delay time for the timer input.
Sets the OFF-delay time for the timer input.
Sets the delay time until the contact is turned ON after the function set with H2-01 turns ON.
Sets the delay time to deactivate the contact after the function set in H2-01 deactivates.
Expert
b4-05
(0B32)
Terminal M3-M4 ON­Delay Time
Sets the delay time to activate the contact after the function set in H2-02 activates.
Expert
b4-06
(0B33)
Terminal M3-M4 OFF­Delay Time
Sets the delay time to deactivate the contact after the function set in H2-02 deactivates.
Expert
18 YASKAWA TOEPYAIGA5002A GA500 Programming
Default
(Range)
0.0 s
(0.0 - 3000.0 s)
0.0 s
(0.0 - 3000.0 s)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
Ref.
180
180
181
181
181
181
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b4-07
(0B34)
Name Description
Terminal P2 ON-Delay Time
Expert
b4-08
(0B35)
Terminal P2 OFF-Delay Time
Expert

b5: PID control

No.
(Hex.)
b5-01
(01A5)
b5-02
(01A6)
RUN
b5-03
(01A7)
RUN
b5-04
(01A8)
RUN
b5-05
(01A9)
RUN
b5-06
(01AA)
RUN
b5-07
(01AB)
RUN
b5-08
(01AC)
RUN
Expert
Name Description
PID Mode Setting
Proportional Gain (P)
Integral Time (I)
Integral Limit
Derivative Time (D)
PID Output Limit
PID Offset Adjustment
PID Primary Delay Time Constant
Sets the delay time until the contact is turned ON after the function set with H2-03 turns ON.
Sets the delay time to deactivate the contact after the function set in H2-03 deactivates.
Sets the type of PID control.
0 : Disabled
1 : Standard
2 : Standard (D on feedback)
3 : Fref + PID Trim
4 : Fref + PID Trim (D on feedback)
5 : Same as 7series & prior, b5-01=1
6 : Same as 7series & prior, b5-01=2
7 : Same as 7series & prior, b5-01=3
8 : Same as 7series & prior, b5-01=4
Note:
Use settings 5 to 8 when the drive is a replacement for a previous generation drive.
Sets the proportional gain (P) that is applied to PID input.
Sets the integral time (I) that is applied to PID input.
Sets the upper limit for integral control (I) as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the derivative time (D) for PID control. This parameter adjusts system responsiveness.
Sets the maximum possible output from the PID controller as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the offset for the PID control output as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Sets the primary delay time constant for the PID control output. Usually it is not necessary to change this setting.
Default
(Range)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
Default
(Range)
0
(0 - 8)
1.00
(0.00 - 25.00)
1.0 s
(0.0 - 360.0 s)
100.0%
(0.0 - 100.0%)
0.00 s
(0.00 - 10.00 s)
100.0%
(0.0 - 100.0%)
0.0%
(-100.0 - +100.0%)
0.00 s
(0.00 - 10.00 s)
Ref.
181
181
Ref.
187
188
188
188
189
189
189
189
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 19
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-09
(01AD)
b5-10
(01AE)
RUN
b5-11
(01AF)
b5-12
(01B0)
b5-13
(01B1)
b5-14
(01B2)
b5-15
(01B3)
b5-16
(01B4)
b5-17
(01B5)
RUN
b5-18
(01DC)
b5-19
(01DD)
RUN
b5-20
(01E2)
b5-34
(019F)
RUN
Name Description
PID Output Level Selection
Sets the polarity of the PID output.
0 : Normal Output (Direct Acting)
1 : Reverse Output (Reverse Acting)
PID Output Gain Setting
Sets the amount of gain to apply to the PID output.
PID Output Reverse Selection
Sets the function that enables and disables reverse motor rotation for negative PID control output.
0 : Lower Limit is Zero
1 : Negative Output Accepted
Feedback Loss Detection Select
Sets the drive response to PID feedback loss/excess. Sets drive operation after the drive detects PID feedback loss/excess.
0 : Digital Out Only, Always Detect
1 : Alarm + Digital Out, Always Det
2 : Fault + Digital Out, Always Det
3 : Digital Out Only, @ PID Enable
4 : Alarm + Digital Out, @PID Enable
5 : Fault + Digital Out, @PID Enable
PID Feedback Loss Detection Lvl
Sets the level that triggers PID Feedback Loss [FbL] detection as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Feedback Loss Detection Time
PID Sleep Function Start Level
Sets the length of time that PID Feedback must be less than b5-13 [PID Feedback Loss Detection Lvl] to detect PID Feedback Loss [FbL].
Sets the output level that triggers the PID Sleep function.
PID Sleep Delay Time
Sets a delay time to start or stop the PID Sleep function.
PID Accel/Decel Time
Raises or lowers the PID setpoint using the acceleration and deceleration times set to the drive. This is a soft-starter for the PID setpoint.
b5-19 PID Setpoint Selection
Sets the function that enables and disables b5-19 [PID Setpoint Value].
0 : Disabled
1 : Enabled
PID Setpoint Value
Sets the PID setpoint when b5-18 = 1 [b5-19 PID Setpoint Selection = Enabled].
PID Unit Selection
Sets the number of digits to set and show the PID setpoint.
0 : 0.01Hz units
1 : 0.01% units
2 : rev/min
3 : User Units
PID Output Lower Limit Level
Sets the output lower limit for the PID control as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
Default
(Range)
0
(0, 1)
1.00
(0.00 - 25.00)
0
(0, 1)
0
(0 - 5)
0%
(0 - 100%)
1.0 s
(0.0 - 25.5 s)
Determined by A1-02
(0.0 - 590.0)
0.0 s
(0.0 - 25.5 s)
0.0 s
(0.0 - 6000.0 s)
0
(0, 1)
0.00%
(0.00 - 100.00%)
1
(0 - 3)
0.0%
(-100.0 - +100.0%)
Ref.
189
189
190
190
191
191
191
191
191
192
192
192
192
20 YASKAWA TOEPYAIGA5002A GA500 Programming
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-35
(01A0)
RUN
b5-36
(01A1)
b5-37
(01A2)
b5-38
(01FE)
b5-39
(01FF)
b5-40
(017F)
b5-47
(017D)
b5-53
(0B8F)
RUN
b5-55
(0BE1)
b5-56
(0BE2)
b5-57
(11DD)
b5-58 to b5-60:
(1182 - 1184)
RUN
b5-61
(119A)
Name Description
PID Input Limit Level
Sets the output upper limit for the PID control as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID High Feedback Detection Lvl
Sets the level that triggers Excessive PID Feedback [FbH] as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID High Feedback Detection Time
PID User Unit Display Scaling
PID User Unit Display Digits
Sets the length of time that the PID feedback signal must be more than the level set in b5- 36 [PID Feedback High Detection Lvl] to cause Excessive PID Feedback [FbH].
Sets the value that the drive sets or shows as the PID setpoint when at the maximum output frequency.
Sets the number of digits to set and show the PID setpoint.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
Frequency Reference Monitor @PID
Sets the contents for monitor U1-01 [Frequency Reference] in PID control.
0 : U1-01 Includes PID Output
1 : U1-01 Excludes PID Output
PID Trim Mode Output Reverse Sel
Sets reverse motor rotation when the PID control output is negative.
0 : Lower Limit is Zero
1 : Negative Output Accepted
PID Integrator Ramp Limit
PID Feedback Monitor Selection
PID Feedback Monitor Gain
PID Feedback Monitor Bias
Sets the responsiveness of PID control when the PID feedback changes quickly.
Sets the monitor (Ux-xx) used as the PID Feedback. Set the x-xx part of the Ux-xx [Monitor].
Sets the gain for the monitor set in b5-55 [PID Feedback Monitor Selection].
Sets the bias for the monitor specified in b5-55 [PID Feedback Monitor Selection].
PID Setpoints 2 to 4
Sets the PID setpoint when H1-xx = 3E or 3F [MFDI Function Selection = PID Setpoint Selection 1/2]. This value is a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Trim Mode Lower Limit Sel
Sets the function that adjusts the PID output in relation to the frequency reference.
0 : Disabled
1 : Enabled
Default
(Range)
1000.0%
(0.0 - 1000.0%)
100%
(0 - 100%)
1.0 s
(0.0 - 25.5 s)
Determined by b5-20
(1 - 60000)
Determined by b5-20
(0 - 3)
0
(0, 1)
1
(0, 1)
0.0 Hz
(0.0 - 10.0 Hz)
000
(000 - 999)
1.00
(0.00 - 10.00)
0.00
(-10.00 - +10.00)
0.00%
(0.00 - 100.00%)
0
(0, 1)
Ref.
193
193
193
193
193
194
194
194
194
195
195
195
Parameter List
1
195
YASKAWA TOEPYAIGA5002A GA500 Programming 21
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b5-62
(119B)
b5-63
(119C)
b5-64
(119D)
b5-65
(119F)
b5-66
(11DE)
b5-67
(11DF)
b5-89
(0B89)
RUN
b5-90
(0B90)
b5-91
(0B91)
RUN
b5-92
(0B92)
RUN
b5-93
(0B93)
RUN
b5-94
(0B94)
RUN
b5-95
(0B95)
b5-96
(0B96)
RUN
Name Description
PID Trim Mode Lower Limit Value
Sets the PID Trim Mode Lower Limit Value as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output frequency.
A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
A1-02 = 8: E9-02 [Maximum Speed]
PID Differential FB Monitor Sel
PID Differential FB Monitor Gain
PID Differential FB Monitor Bias
PID Feedback Monitor Level
Selects the monitor (Ux-xx) used as the PID Differential Feedback. Set the x-xx part of the Ux-xx [Monitor].
Sets the gain for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
Sets the bias for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
Sets the signal level for the monitor specified in b5-55 [PID Feedback Monitor Selection].
0 : Absolute
1 : Bi-directional (+/-)
PID Differential FB Monitor Lvl
Sets the signal level for the monitor specified in b5-63 [PID Differential FB Monitor Sel].
0 : Absolute
1 : Bi-directional (+/-)
Sleep Method Selection
Sets sleep and wake up operation when using PID.
0 : Standard
1 : EZ Sleep/Wake-up
EZ Sleep Unit
Sets the measurement units for b5-91 [EZ Sleep Minimum Speed] and b5-92 [EZ Sleep Level].
0 : 0.1Hz units
1 : rev/min
EZ Sleep Minimum Speed
Sets the minimum speed for the EZ Sleep/Wakeup function. This parameter uses the largest value from b5-91, b5-34 [PID Output Lower Limit Level], and d2-02 [Frequency Reference Lower Limit].
EZ Sleep Level
Sets the value that the output frequency or motor speed must be less than for longer than b5-93 [EZ Sleep Time] to enter Sleep Mode.
EZ Sleep Time
Sets the length of time that the output frequency or motor speed must be less than b5-92 [EZ Sleep Level] to enter Sleep Mode.
EZ Sleep Wake-up Level
Sets the level at which the drive resumes operation when exiting Sleep Mode.
EZ Sleep Wake-up Mode
Sets the wake-up mode to use when exiting Sleep Mode.
0 : Absolute
1 : Setpoint Delta
EZ Sleep Wake-up Time
Sets the EZ Wake-up time.
Default
(Range)
0.00%
(0.00 - 100.00%)
000
(000 - 999)
1.00
(0.00 - 10.00)
0.00
(-10.00 - +10.00)
0
(0, 1)
0
(0, 1)
0
(0, 1)
0
(0, 1)
-1
(r/min))
-1
(r/min))
-1
-1
(r/min)
(r/min)
0.0 Hz or 0 min
(0.0 to 590.0 Hz or 0 to
35400 min
0.0 Hz or 0 min
(0.0 to 590.0 Hz or 0 to
35400 min
5.0 s
(0.0 - 1000.0 s)
0.00%
(0.00 - 600.00%)
0
(0, 1)
1.0 s
(0.0 - 1000.0 s)
Ref.
196
196
196
196
196
196
196
197
197
197
197
197
198
198
22 YASKAWA TOEPYAIGA5002A GA500 Programming

b6: Dwell Function

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.5 b: Application
No.
(Hex.)
b6-01
Name Description
Dwell Reference at Start
(01B6)
b6-02
Dwell Time at Start
(01B7)
b6-03
Dwell Reference at Stop
(01B8)
b6-04
Dwell Time at Stop
(01B9)

b8: Energy Saving

No.
(Hex.)
b8-01
(01CC)
b8-02
(01CD)
RUN
Expert
b8-03
(01CE)
RUN
Expert
b8-04
(01CF)
Expert
b8-05
(01D0)
Expert
b8-06
(01D1)
Expert
b8-16
(01F8)
Expert
b8-17
(01F9)
Expert
b8-18
(01FA)
Expert
b8-19
(0B40)
Expert
b8-20
(0B41)
Expert
Name Description
Energy Saving Control Selection
Energy Saving Gain
Energy Saving Filter Time
Energy Saving Coefficient Value
Power Detection Filter Time
Search Operation Voltage Limit
PM E-Save Coefficient Ki
PM E-Save Coefficient Kt
E-Save d-axis Current FilterTime
E-Save Search Frequency
E-Save Search Width
Sets the output frequency that the drive will hold momentarily when the motor starts.
Sets the length of time that the drive will hold the output frequency when the motor starts.
Sets the output frequency that the drive will hold momentarily when ramping to stop the motor.
Sets the length of time for the drive to hold the output frequency when ramping to stop the motor.
Sets the Energy-saving control function.
0 : Disabled
1 : Enabled
2 : Automatic Optimization
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], you can only select setting 2 in Expert Mode.
Sets the gain for Energy-saving control.
Sets the responsiveness for Energy-saving control.
Sets the Energy-saving control coefficient to maintain maximum motor efficiency. The default setting is for Yaskawa motors.
Sets the time constant to measure output power.
Sets the voltage limit for Search Operation as a percentage of the motor rated voltage.
Sets torque linearity. This parameter uses the Ki value from the motor nameplate. Usually it is not necessary to change this setting.
Sets torque linearity. This parameter uses the Kt value from the motor nameplate. Usually it is not necessary to change this setting.
Sets the d-axis current reference filter time constant.
Sets the frequency of Energy-saving control search operations. Usually it is not necessary to change this setting.
Sets the amplitude of Energy-saving control search operations.
Default
(Range)
0.0
(Determined by A1-02)
0.0 s
(0.0 - 10.0 s)
0.0
(Determined by A1-02)
0.0 s
(0.0 - 10.0 s)
Default
(Range)
0
(0 - 2)
Determined by A1-02
(0.0 - 10.0)
Determined by A1-02
C6-01 and o2-04
(0.00 - 10.00 s)
Determined by C6-01,
E2-11, and o2-04
(0.00 - 655.00)
20 ms
(0 - 2000 ms)
0%
(0 - 100%)
1.00
(0.00 - 3.00)
1.00
(0.00 - 3.00)
0.100 s
(0.000 - 5.000 s)
Determined by A1-02
(10 - 300 Hz)
1.0 degrees
(0.1 - 5.0 degrees)
Ref.
198
199
199
199
Ref.
199
200
200
200
200
200
201
Parameter List
201
1
201
201
201
YASKAWA TOEPYAIGA5002A GA500 Programming 23
1.5 b: Application
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
b8-21
(0B42)
Expert
b8-22
(0B43)
Expert
b8-23
(0B44)
Expert
b8-24
(0B45)
Expert
b8-25
(0B46)
Expert
b8-26
(0B47)
Expert
b8-28
(0B8B)
Expert
b8-29
(0B8C)
Name Description
PM E-Save Search Gain
Sets the gain of Energy-saving control search operations.
PM E-Save Search LPF Cutoff Freq
Sets the frequency of the filter used to extract the high-efficiency phase from search operations. Usually it is not necessary to change this setting.
PM E-Save Search Limit
Sets the search operations output limit. Usually it is not necessary to change this setting.
PM E-Save High Freq ACR Gain
PM E-Save Search Start Level
PM E-Save Power Setpoint
Over Excitation Action Selection
Sets the gain for high-frequency current control.
Sets the start level for search operations.
Sets a value to increase torque accuracy.
Sets the function for excitation operation.
0 : Disabled
1 : Enabled
Energy Saving Priority Selection
Sets the priority of drive response between changes to the load or Energy-saving control. Enable this to prioritize energy-saving control. Disable this to prioritize tracking related to fast load changes, and prevent motor stall.
0 : Priority: Drive Response
1 : Priority: Energy Savings
Default
(Range)
0.3Hz
(0.1 - 20.0 Hz)
10.0 Hz
(1.0 - 30.0 Hz)
15.0 degrees
(0.0 - 30.0 degrees)
200.0 Hz
(100.0 - 1000.0 Hz)
10.0%
(0.0 - 100.0%)
0.0%
(-10.0 - +10.0%)
0
(0, 1)
0
(0, 1)
Ref.
202
202
202
202
202
202
203
203
24 YASKAWA TOEPYAIGA5002A GA500 Programming
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

C1: Accel & Decel Time

1.6 C: Tuning

No.
(Hex.)
C1-01
(0200)
RUN
C1-02
(0201)
RUN
C1-03
(0202)
RUN
C1-04
(0203)
RUN
C1-05
(0204)
RUN
C1-06
(0205)
RUN
C1-07
(0206)
RUN
C1-08
(0207)
RUN
C1-09
(0208)
RUN
C1-10
(0209)
C1-11
(020A)
C1-14
(0264)
RUN
Name Description
Acceleration Time 1
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 1
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 2
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 2
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 3
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 3
Sets the length of time to decelerate from maximum output frequency to zero.
Acceleration Time 4
Sets the length of time to accelerate from zero to maximum output frequency.
Deceleration Time 4
Sets the length of time to decelerate from maximum output frequency to zero.
Fast Stop Time
Sets the length of time that the drive will decelerate to zero for a Fast Stop.
Note:
Decelerating too quickly can cause an ov [Overvoltage] fault that shuts off the drive
while the motor to coasts to a stop. Set a Fast Stop time in C1-09 that prevents motor coasting and makes sure that the motor stops quickly and safely.
When L2-29 = 0 [Kinetic Energy Backup Method = Single Drive KEB Ride-Thru 1]
and you do KEB Auto-Tuning, the drive will automatically set C1-09. If you must not change the Fast Stop time, do not do KEB Tuning.
Accel/Decel Time Setting Units
Sets the setting units for C1-01 to C1-08 [Accel/Decel Times 1 to 4], C1-09 [Fast Stop
Time], L2-06 [Kinetic Energy Backup Decel Time], and L2-07 [Kinetic Energy Backup Accel Time].
0 : 0.01 s (0.00 to 600.00 s)
1 : 0.1 s (0.0 to 6000.0 s)
Accel/Decel Time Switching Frequency
Accel/Decel Rate Frequency
Sets the frequency at which the drive will automatically change acceleration and deceleration times.
Sets the base frequency used to calculate acceleration and deceleration rates.
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
10.0 s
(0.0 - 6000.0 s)
1
(0, 1)
Determined by A1-02
(0.0 - 590.0 Hz)
0.0 Hz
(0.0 - 590.0 Hz)
Ref.
206
206
206
206
206
206
207
207
207
207
208
208
Parameter List
1

C2: S-Curve Characteristics

No.
(Hex.)
C2-01
(020B)
C2-02
(020C)
Name Description
S-Curve Time @ Start of Accel
S-Curve Time @ End of Accel
Sets the S-curve acceleration time at start.
Sets the S-curve acceleration time at completion.
YASKAWA TOEPYAIGA5002A GA500 Programming 25
Default
(Range)
Determined by A1-02
(0.00 - 10.00 s)
0.20 s
(0.00 - 10.00 s)
Ref.
210
210
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C2-03
(020D)
C2-04
(020E)
Name Description
S-Curve Time @ Start of Decel
S-Curve Time @ End of Decel
Sets the S-curve deceleration time at start.
Sets the S-curve deceleration time at completion.

C3: Slip Compensation

No.
(Hex.)
C3-01
(020F)
RUN
C3-02
(0210)
RUN
C3-03
(0211)
C3-04
(0212)
C3-05
(0213)
C3-16
(0261)
Expert
C3-17
(0262)
Expert
C3-18
(0263)
Expert
C3-21
(033E)
RUN
C3-22
(0241)
RUN
C3-23
(0242)
Name Description
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
E2-01 [Motor Rated Current (FLA)]
E2-02 [Motor Rated Slip]
E2-03 [Motor No-Load Current]
Slip Compensation Delay Time
Sets the slip compensation delay time when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor rated slip.
Slip Compensation at Regen
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
Output Voltage Limit Selection
Sets the automatic reduction of motor magnetic flux when the output voltage is saturated.
0 : Disabled
1 : Enabled
Vout Modulation Limit Start Lvl
Vout Modulation Limit Max Level
Output Voltage Limit Level
Motor 2 Slip Compensation Gain
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the modulation factor used with C3-18 [Output Voltage Limit Level] for the output voltage limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
E4-01 [Motor 2 Rated Current]
E4-02 [Motor 2 Rated Slip]
E4-03 [Motor 2 Rated No-Load Current]
Motor 2 Slip Comp Delay Time
Motor 2 Slip Compensation Limit
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip compensation response is too slow. Usually it is not necessary to change this setting.
Sets the upper limit for the slip compensation function as a percentage of the motor 2 rated slip.
Default
(Range)
0.20 s
(0.00 - 10.00 s)
0.00 s
(0.00 - 10.00 s)
Default
(Range)
Determined by A1-02
(0.0 - 2.5)
Determined by A1-02
(0 - 10000 ms)
200%
(0 - 250%)
0
(0 - 2)
0
(0, 1)
90.0%
(70.0 - 90.0%)
100.0%
(85.0 - 100.0%)
90.0%
(50.0 - 100.0%)
Determined by E3-01
(0.0 - 2.5)
Determined by E3-01
(0 - 10000 ms)
200%
(0 - 250%)
Ref.
210
210
Ref.
211
211
211
212
212
212
213
213
213
213
213
26 YASKAWA TOEPYAIGA5002A GA500 Programming
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C3-24
(0243)
Name Description
Motor 2 Slip Comp during Regen
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
C3-29
(1B5D)
Expert
Slip Compensation Gain @ Low Spd
Sets the gain for the slip compensation function in the low speed range. Usually it is not necessary to change this setting.

C4: Torque Compensation

No.
(Hex.)
C4-01
(0215)
RUN
C4-02
(0216)
RUN
C4-03
(0217)
C4-04
(0218)
C4-05
(0219)
C4-06
(021A)
C4-07
(0341)
RUN
C4-23
(1583)
RUN
Expert
Name Description
Torque Compensation Gain
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when operating multiple motors.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], you cannot change this parameter during drive run.
Torque Compensation Delay Time
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Note:
If A1-02 = 8 [Control Method Selection = EZOLV], you cannot change the setting while the drive is running.
Torque Compensation @ FWD Start
Torque Compensation @ REV Start
Torque Compensation Time
Motor 2 Torque Comp Delay Time
Motor 2 Torque Compensation Gain
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
Sets the starting torque constant to use with C4-03 and C4-04 [Torque Compensation @ FWD/REV Start].
Sets the value if ov [Overvoltage] occurs with sudden changes in the load, at the end of acceleration, or at the start of deceleration.
Sets the gain for motor 2 torque compensation function when using the Motor Switch function.
Current Control Gain
Current control gain. Usually it is not necessary to change this parameter.
Default
(Range)
0
(0 - 2)
0.0
(0.0 - 2.5)
Default
(Range)
Determined by A1-02
(0.00 - 2.50)
Determined by A1-02
(0 - 60000 ms)
0.0%
(0.0 - 200.0%)
0.0%
(-200.0 - 0.0%)
10 ms
(0 - 200 ms)
150 ms
(0 - 10000 ms)
1.00
(0.00 - 2.50)
1.00
(0.50 - 2.50)
Ref.
214
214
Ref.
215
215
215
215
216
216
216
216

C5: Automatic Speed Regulator (ASR: Automatic Speed Regulator)

No.
(Hex.)
C5-01
(021B)
RUN
C5-02
(021C)
RUN
Name Description
ASR Proportional Gain 1
Sets the gain to adjust ASR response.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Integral Time 1
Sets the ASR integral time.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Determined by A1-02
(0.000 - 60.000 s)
Ref.
219
219
YASKAWA TOEPYAIGA5002A GA500 Programming 27
Parameter List
1
1.6 C: Tuning
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
No.
(Hex.)
C5-03
(021D)
RUN
C5-04
(021E)
RUN
C5-05
(021F)
C5-06
(0220)
C5-07
(0221)
C5-08
(0222)
C5-12
(0386)
C5-29
(0B18)
Expert
C5-39
(030D)
Name Description
ASR Proportional Gain 2
Sets the gain to adjust ASR response.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Integral Time 2
Sets the ASR integral time.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Limit
Sets the ASR output limit where E1-04 [Maximum Output Frequency] is 100%.
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
ASR Delay Time
Sets the filter time constant of the torque reference output from the speed loop. Usually it is not necessary to change this setting.
ASR Gain Switchover Frequency
Sets the frequency where the drive will switch between these parameters:
C5-01 and C5-03 [ASR Proportional Gain 1/2] C5-02 and C5-04 [ASR Integral Time 1/2]
ASR Integral Limit
Set the upper limit of the ASR integral amount as a percentage of the rated load.
Integral Operation @ Accel/Decel
Sets ASR integral operation during acceleration and deceleration.
0 : No
1 : Yes
Note:
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
Speed Control Response
Sets the level of speed control responsiveness. Usually it is not necessary to change this setting.
0 : Standard
1 : High Performance 1
ASR Primary Delay Time Const 2
Sets the filter time constant used when the torque reference is output from ASR. Usually it is not necessary to change this parameter.
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Determined by A1-02
(0.000 - 60.000 s)
5.0%
(0.0 - 20.0%)
Determined by A1-02
(0.000 - 0.500 s)
Determined by A1-02
(Determined by A1-02)
400%
(0 - 400%)
0
(0, 1)
1
(0, 1)
0.000 s
(0.000 - 0.500 s)
Ref.
219
220
220
220
220
220
221
221
221
28 YASKAWA TOEPYAIGA5002A GA500 Programming

C6: Duty & Carrier Frequency

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.6 C: Tuning
No.
(Hex.)
C6-01
(0223)
C6-02
(0224)
C6-03
(0225)
C6-04
(0226)
C6-05
(0227)
C6-09
(022B)
Name Description
Normal / Heavy Duty Selection
Sets the drive duty rating.
0 : Heavy Duty Rating
1 : Normal Duty Rating
Carrier Frequency Selection
Sets the carrier frequency for the transistors in the drive.
1 : 2.0 kHz
2 : 5.0 kHz (4.0 kHz for AOLV/PM)
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM4 (Audible Sound 1)
8 : Swing PWM4 (Audible Sound 2)
9 : Swing PWM4 (Audible Sound 3)
A : Swing PWM4 (Audible Sound 4)
B : Leakage Current Rejection PWM
F : User Defined (C6-03 to C6-05)
Note:
The setting range changes when the A1-02 [Control Method Selection] value
changes:
5, 8 [OLV/PM, EZOLV]: You cannot set to 7 to A.When 6 [AOLV/PM]: 2 [5.0 kHz (AOLV/PM: 4.0 kHz)] is available.
The carrier frequency for Swing PWM 1 is equivalent to 2.0 kHz. Swing PWM
applies a special PWM pattern to decrease the audible noise.
Carrier Frequency Upper Limit
Carrier Frequency Lower Limit
Carrier Freq Proportional Gain
Carrier Freq at Rotational Tune
Sets the upper limit of the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the lower limit of the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the proportional gain for the carrier frequency. Set C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)] to set this parameter.
Sets the Auto-Tuning carrier frequency. Usually it is not necessary to change this setting.
0 : 5 kHz
1 : Use C6-03
Default
(Range)
1
(0, 1)
Determined by A1-02,
C6-01, and o2-04
(Determined by A1-02)
Determined by C6-02
(1.0 - 15.0 kHz)
Determined by C6-02
(1.0 - 15.0 kHz)
Determined by C6-02
(0 - 99)
0
(0, 1)
Ref.
221
222
223
224
224
224
Parameter List
1
YASKAWA TOEPYAIGA5002A GA500 Programming 29

1.7 d: Reference Settings

V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
1.7 d: Reference Settings

d1: Frequency Reference

No.
(Hex.)
d1-01
(0280)
RUN
d1-02
(0281)
RUN
d1-03
(0282)
RUN
d1-04
(0283)
RUN
d1-05
(0284)
RUN
d1-06
(0285)
RUN
d1-07
(0286)
RUN
d1-08
(0287)
RUN
d1-09
(0288)
RUN
d1-10
(028B)
RUN
d1-11
(028C)
RUN
Name Description
Reference 1
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 2
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 3
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 4
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 5
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 6
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 7
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 8
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 9
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 10
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Reference 11
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Note:
When A1-02 = 6 [Control Method Selection = AOLV/PM], the default setting is o1-03 = 1 [0.01% (100% = E1-04)].
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
Ref.
228
229
229
229
229
229
230
230
230
230
231
30 YASKAWA TOEPYAIGA5002A GA500 Programming