Whirlpool YWED9400SZ, WGD9400ST, WGD9400SB, WGD9600TU, WGD9600TB Installation Instructions

...
0 (0)

DRYER INSTALLATION INSTRUCTIONS

GAS (U.S.A. AND CANADA)

ELECTRIC (CANADA ONLY)

INSTRUCTIONS D'INSTALLATION DE LA SÉCHEUSE

À GAZ (É.-U. ET CANADA)

ÉLECTRIQUE (CANADA UNIQUEMENT)

TABLE OF CONTENTS

 

DRYER SAFETY..............................................................................

2

INSTALLATION REQUIREMENTS ................................................

4

Tools and Parts ............................................................................

4

Optional Equipment .....................................................................

4

Location Requirements................................................................

4

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ..........

8

Electrical Requirements ...............................................................

8

GAS DRYER POWER HOOKUP....................................................

9

Gas Supply Requirements ...........................................................

9

Make Gas Connection ...............................................................

10

VENTING .......................................................................................

10

Venting Requirements................................................................

10

Plan Vent System.......................................................................

11

Install Vent System.....................................................................

13

INSTALL LEVELING LEGS...........................................................

13

CONNECT VENT...........................................................................

13

CONNECT INLET HOSE (STEAM MODELS) .............................

13

LEVEL DRYER ..............................................................................

14

COMPLETE INSTALLATION .......................................................

14

TROUBLESHOOTING ..................................................................

15

TABLE DES MATIÈRES

 

SÉCURITÉ DE LA SÉCHEUSE ....................................................

17

EXIGENCES D'INSTALLATION ...................................................

19

Outillage et pièces......................................................................

19

Équipement facultatif .................................................................

19

Exigences d'emplacement.........................................................

19

RACCORDEMENT DE L’ALIMENTATION À LA SÉCHEUSE

 

ÉLECTRIQUE - CANADA UNIQUEMENT...................................

23

Spécifications électriques ..........................................................

23

RACCORDEMENT DE L’ALIMENTATION À

 

LA SÉCHEUSE À GAZ..................................................................

24

Alimentation en gaz....................................................................

24

Raccordement au gaz ................................................................

25

ÉVACUATION................................................................................

26

Exigences concernant l'évacuation ...........................................

26

Planification du système d’évacuation ......................................

27

Installation du système d’évacuation.........................................

28

INSTALLATION DES PIEDS DE NIVELLEMENT........................

29

RACCORDEMENT DU CONDUIT D’ÉVACUATION ..................

29

RACCORDEMENT DES TUYAUX D'ALIMENTATION

 

(MODÈLES À VAPEUR)................................................................

29

RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE...........................

30

ACHEVER L'INSTALLATION .......................................................

30

DÉPANNAGE.................................................................................

31

W10224610A

SP PN W10224611A

Whirlpool YWED9400SZ, WGD9400ST, WGD9400SB, WGD9600TU, WGD9600TB Installation Instructions

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

2

WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building, or area of all occupants.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.

For more information, contact your gas supplier.

If a gas leak is detected, follow the “What to do if you smell gas” instructions.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

For All Installations:

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)

Level

Vent clamps

Gas Installations:

Caulking gun and compound (for installing new exhaust vent)

Tin snips (new vent installations)

¼" nut driver (recommended)

Tape measure

Pliers

8" or 10" pipe wrench

Pipe-joint compound

8" or 10" adjustable wrench

resistant to LP gas

 

 

(for gas connections)

 

Parts supplied

Non-Steam Models

4 Leveling legs

Steam Models

A

B

C

E

A. Leveling legs (4)

 

 

D. Inlet hose with right-angle

B. “Y” connector

 

 

connector

C. Short inlet hose

 

 

E. Rubber washer

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your Use and Care Guide.

Optional Equipment

Refer to your Use and Care guide for information about the accessories available for your dryer.

Location Requirements

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to the bottom of the dryer.

Steam models only: Cold water faucets located within

4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the cold water supply from your washer using the “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic sensor cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

4

Dryer Dimensions

D

A

B C

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A

38" (9652 mm)

38" (9652 mm)

 

 

 

B

32 9/16" (686 mm)

31 1/2" (800 mm)

C

27" (686 mm)

27" (686 mm)

 

 

 

D

52 9/16" (1335 mm)

51 1/2" (1308 mm)

NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

A

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C*

 

 

 

 

D

 

 

E*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

 

 

 

Non-Steam

 

 

 

(Electric or Gas)

 

 

 

(Electric or Gas)

 

 

 

 

A

0" (0 mm)

 

0" (0 mm)

 

 

 

 

B

38" (9652 mm)

 

38" (9652 mm)

 

 

 

 

C*

1" (25 mm)

 

1" (25 mm)

 

 

 

 

D

27" (686 mm)

 

27" (686 mm)

 

 

 

 

E*

1" (25 mm)

 

1" (25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Required spacing

NOTE: Some models are not recommended for undercounter installation.

Closet installation - Dryer only

 

(460 mm)

A*

B

C**

 

Side view
Closet door with vents

 

 

 

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

1" (25 mm)

1" (25 mm)

 

 

 

B

32 9/16" (686 mm)

31 1/2" (800 mm)

 

 

 

C**

5" (127 mm)

5" (127 mm)

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

5

Recessed or closet installation - Dryer on pedestal

A

B

C

 

(460 mm)

 

D*

E

F**

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A

1" (25 mm)

1" (25 mm)

 

 

 

B

27" (686 mm)

27" (686 mm)

 

 

 

C

1" (25 mm)

1" (25 mm)

 

 

 

D*

1" (25 mm)

1" (25 mm)

 

 

 

E

32 9/16" (686 mm)

31 1/2" (800 mm)

 

 

 

F**

5" (127 mm)

5" (127 mm)

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed

NOTE: Some models are not recommended for recessed or closet installation.

Recommended installation spacing for cabinet installation

NOTE: Some models are not recommended for cabinet installation.

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

A* B*

 

 

 

 

C*

D**

E

F* G

H

I

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

7" (178 mm)

7" (178 mm)

 

 

 

B*

7" (178 mm)

7" (178 mm)

 

 

 

C*

9" (229 mm)

9" (229 mm)

 

 

 

D**

5" (127 mm)

5" (127 mm)

 

 

 

E

32 9/16" (686 mm)

31 1/2" (800 mm)

 

 

 

F*

1" (25 mm)

1" (25 mm)

 

 

 

G

1" (25 mm)

1" (25 mm)

 

 

 

H

27" (686 mm)

27" (686 mm)

 

 

 

I

1" (25 mm)

1" (25 mm)

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

6

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

48 in.2 * (310 cm2)

3"* (76 mm)

 

3"* (76 mm)

24 in.2 *

1"* (25 mm)

(155 cm2)

 

 

6"* (152 mm)

76" (1930 mm)

A*

 

 

 

1"

 

 

 

27"

 

1"

 

 

 

 

 

 

 

 

 

(25 mm)

 

 

(686 mm)

(25 mm)

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

5 ½" (140 mm)

5" (127 mm)

 

 

 

*Required spacing

NOTE: Some models are not recommended for stacked recessed or closet installation.

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers

Metal exhaust system hardware, which is available for purchase from your dealer.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

For gas dryers

Mobile Home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.

7

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

To supply the required 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

For further information, please reference the service numbers located in the “Assistance or Service” section.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

4-wire receptacle 14-30R

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317.

8

GAS DRYER POWER HOOKUP

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

Gas supply line

Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration.

1/2" IPS pipe is recommended.

3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

If you are using Natural gas, do not use copper tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Must include a shutoff valve:

In the U.S.A.:

An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

The location should be easy to reach for opening and closing.

A C E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

D

A. 3/8" flexible gas connector

C. 1/8" NPT minimum plugged

B. 3/8" pipe to flare adapter

tapping

fitting

D. 1/2" NPT gas supply line

 

 

 

 

 

 

E. Gas shutoff valve

Gas supply connection requirements

Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON®† tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

Burner input requirements

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

9

Dryer gas pipe

The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread.

B

*6¼" (159 mm)

A

 

1½"

 

 

(38 mm)

A. 1/2" NPT gas supply line

B. 3/8" NPT dryer pipe

*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (254 mm) or 15.5" (394 mm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional

18" (460 mm) from the floor.

Make Gas Connection
1.Remove the red cap from the gas pipe.

2.Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.

AB

A.Flared male fitting

B.Non-flared male fitting

NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON®† tape.

A combination of pipe fittings must be used to connect the dryer to the existing gas line. Shown is a recommended connection. Your connection may be different, according to the supply line type, size and location.

D

A

B

C

 

A. 3/8" flexible gas

C. 3/8" to 3/8" pipe elbow

connector

D. 3/8" pipe-to-flare

B. 3/8" dryer pipe

adapter fitting

3.Open the shutoff valve in the supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A.Closed valve

B.Open valve

4.Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

VENTING

Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

10