Whirlpool WFG540H0E, WFG720H0A, WFG745H0F, WFG540H0A, WFG710H0A User Manual

...
0 (0)
Whirlpool WFG540H0E, WFG720H0A, WFG745H0F, WFG540H0A, WFG710H0A User Manual

30" (76.2 cm) Freestanding Gas Range

PRODUCT MODEL NUMBERS

WFG540H0A

WFG714HLA

WFG720H0A

WFG540H0E

WFG715H0E

WFG745H0F

WFG710H0A

 

 

Type of Gas

Natural Gas:

■■ This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial/rating plate is located on the oven frame behind the top right side of the oven door has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.

Gas Supply Line

■■ Provide a gas supply line if 3/4" (1.9 cm) rigid pipe to the range location. A smaller pipe on longer runs may result in insuffient gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm) minimum. Usually, LP gas suppliers deteremine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Flexible metal appliance connector:

■■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122

to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal appliance connector may

be used for connecting range to the gas supply line.

■■ A 1/2" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.

■■ Do not kink or damage the flexible metal tubing when moving the range.

■■ Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.

B

A. Gas supply line

B. Shutoff valve “open” position

 

 

C. To range

A

C

®TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.

Electrical

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is

recommended that a separate circuit serving only this range be provided.

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood combination above the range, following the range hood or microwave hoods combination instructions for dimensional clearances above the cooktop surface.

A freestanding range may be installed next to combustible walls with zero clearance.

PRODUCT DIMENSIONS

 

 

A.

277/8" (70.8 cm) max. depth

 

 

 

with handle

 

 

B. 36" (91.4 cm) cooktop height

 

 

 

(max.) with leveling legs

 

 

 

screwed all the way in*

A

 

C.

467/8" (119.1 cm) overall

 

 

 

height (max.) with leveling legs

 

 

 

screwed all the way in*

B

C

D.

297/8" (75.9 cm) width

E. 257/16" (64.3 cm) depth.

F

 

 

 

Back of range to front of

 

 

 

 

 

 

cooktop**

E

 

F.

Model/serial rating plate

 

 

 

(located on the oven frame

D

 

 

behind the top right side of the

 

 

 

oven door)

IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.

*Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.

**Front of door and drawer may extend further forward depending on styling.

CABINET OPENING DIMENSIONS

D

B

C

A

E

M

L

K

G

H

F

I

J

A.18" (45.7 cm) upper side cabinet to countertop

B.13" (33 cm) max. upper cabinet depth

C.30" (76.2 cm) min. opening width

D.For minimum clearance to top of cooktop, see NOTE *.

E.301/8" (76.5 cm) min. opening width

F.The shaded areas are recommended for installation of rigid gas pipe.

G.11" (27.6 cm)

H.17" (43.2 cm)

I.2" (5.1 cm)

J.41/2" (11.4)

K.3" (7.6 cm) min. clearance from both sides of range to side wall or other combustible material.

L.Grounded outlet

M.Cabinet door or hinges should not extend into the cutout.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10553363B

Instructions packed with product. Specifications subject to change without notice.

05/05/2016

Loading...