AMB 869/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 28.06.2004 Subject to modification
Document-No.: 4812 731 19874
28.06.2004 / Page 2 AMB 869/G Whirlpool Europe
Doc. No: 4812 731 19874 8528 869 10000 Customer Service
SERVICE
Technical data
Operation type
Cooling / Heating
Dimensions
Indoor-unit
Height 270 mm
Width 800 mm
Depth 168 mm
Outdoor-unit
Height 530 mm
Width 755 mm
Depth 252 mm
Weight
Indoor-unit 10 kg / net
Outdoor-unit 36 kg / net
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Compressor
Type Toshiba, DA 89 X 1C - 23 FZ
Refrigerant
Type R 410 A
Quantity 1140 g
Cooling Capacity
2637 Watt
9000 BTU/h
Heating Capacity
2930 Watt
10000 BTU/h
Airflow / Evaporator Airvolume
460 m3 /h
Dehumidifying Capacity
1.2 l/h
Power Supply
Cooling
Input 799 W
3.7 A
Heating
Input 810 W
3.8 A
Working temp. range
Indoor + 18.0 / + 32.0˚C
Outdoor - 5.0 / + 43.0˚C
Noise level
Indoor-unit 30 - 38 dB
Outdoor-unit 54 dB