SERVICE
Model AMB 867
Version 8528 867 10000 Page
Whirlpool Europe
Customer Services
AMB 867
Service Manual
Air Conditioner
Split Type
AMB 867
Technical data 2
Spare part list 3
Exploded view 4
Circuit diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 04.03.2002 Subject to modification
Document-No.: 4812 731 12417
04.03.2002 / Page 2 AMB 867 Whirlpool Europe
Doc. No: 4812 731 12417 8528 867 10000 Customer Service
Technical data
SERVICE
Factory Code AS-12HR4FD
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 890 mm
Width 270 mm
Depth 168 mm
Outdoor - unit
Height 755 mm
Width 530 mm
Depth 252 mm
Weight
Indoor - unit 11 kg / net
Outdoor - unit 42 kg / net
Cooling Capacity
3515 Watt
12000 BTU / h
Heating Capacity
3806 Watt
13000 BTU / h
Airflow / Evaporator Airvolume
580 m3 / h
Dehumidifying Capacity
1.5 l / h
Noise Level
Indoor - unit 30 - 37 dB(A)
Outdoor - unit 51 dB(A)
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Rated Current (Cooling) 5.8 A
Rated Current (Heating) 5.9 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 9.52
Heating 10.16
Compressor (cooling)
Type 2 K23 S225 BUA
Refrigerant
Type R 22
Quantity 1020 g