SERVICE
Model AMB 857/G
Version 8528 857 10100 Page
Whirlpool Europe
Customer Services
AMB 857/G
Service Manual
Air Conditioner
Split Type
AMB 857/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 08.06.2004 (Mod. 01) Subject to modification
Document-No.: 4812 731 15446
20.03.2004 / Page 2 AMB 857/G Whirlpool Europe
Doc. No: 4812 731 15446 8528 857 10100 Customer Service
SERVICE
Technical data
Factory Code As-09HR4ND
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 800 mm
Width 270 mm
Depth 168 mm
Outdoor - unit
Height 755 mm
Width 530 mm
Depth 252 mm
Weight
Indoor - unit 9 kg / net
Outdoor - unit 40 kg / net
Cooling Capacity
2608 Watt
8900 BTU / h
Heating Capacity
2784 Watt
9500 BTU / h
Airflow / Evaporator Airvolume
420 m3 / h
Dehumidifying Capacity
0,9 l / h
Noise Level
Indoor - unit 27 - 33 dB(A)
Outdoor - unit 50 dB(A)
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Rated Current (Cooling) 4.3 A
Rated Current (Heating) 4.3 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 9.7
Heating 10.2
Compressor (cooling)
Type PG165X1C-4FT
Capacity (CECOMAF) 2860 W
Refrigerant
Type R 1120
Quantity 1120 g