SERVICE
Model AMB 857
Version 8528 857 10000 Page
Whirlpool Europe
Customer Services
AMB 857
Service Manual
Air Conditioner
Split Type
AMB 857
Technical data 2
Spare part list 3
Exploded view 4
Circuit diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 04.03.2002 Subject to modification
Document-No.: 4812 721 19913
04.03.2002 / Page 2 AMB 857 Whirlpool Europe
Doc. No: 4812 721 19913 8528 857 10000 Customer Service
Technical data
SERVICE
Factory Code AS-09HR4FD
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 800 mm
Width 270 mm
Depth 168 mm
Outdoor - unit
Height 755 mm
Width 530 mm
Depth 252 mm
Weight
Indoor - unit 9 kg / net
Outdoor - unit 40 kg / net
Cooling Capacity
2635 Watt
9000 BTU / h
Heating Capacity
2782 Watt
9500 BTU / h
Airflow / Evaporator Airvolume
420 m3 / h
Dehumidifying Capacity
0.9 l / h
Noise Level
Indoor - unit 27 - 33 dB(A)
Outdoor - unit 50 dB(A)
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Rated Current (Cooling) 4.1 A
Rated Current (Heating) 4.2 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 10.23
Heating 10.56
Compressor (cooling)
Type PH 160
Refrigerant
Type R 22
Quantity 860 g