Vendo RSC 4 Operators Manual

Operation & Installation Manual
MODEL RSC Remote
REFRIGERATED SHOWCASE
Document Part #: 1221178 ECN: 56951 Rev: J Date: 10-25-2017
2
The RSC refrigerated display showcase units have been safety and performance-test approved by Intertek, a safety
regulatory testing agency. In the course of new installations or periodic inspections, reference to agency approvals may
be required. The regulatory agency file number is listed below and at the bottom of the Specification table on page 5.
ETL File #4007858
3
DIMENSIONS RSC 6
4
SPECIFICATIONS RSC 6
5
DIMENSIONS RSC 4
6
SPECIFICATIONS RSC 4
7
DIMENSIONS RSC 3
8
SPECIFICATIONS RSC 3
9
SAFETY PRECAUTIONS
10
UNPACKING
11
INITIAL SET-UP
12 – 17
Cabinet Set-up………………………………………………………..
12 – 17
ELECTRICAL INSTALLATION
18 - 19
Wiring Diagram………………………………………………………
19
REFRIGERATION INSTALLATION
20 – 21
VALANCE INSTALLATION
21 – 22
START-UP & OPERATING INFORMATION
23 – 24
Start-up Information and Performance Evaluation…………………..
23
Operating Guidelines……………………………………....................
23
Controller Operation and Error Codes……………………………….
24
GENERAL MAINTENANCE
25 – 29
Cleaning the Honeycomb……………………………….....................
25 – 26
Cleaning the Filter…………………………………………………....
27 – 28
Cleaning the Bottom of the Inner Box & the Drain…….....................
28
Cleaning the Cabinet……………………………………....................
29
STORING THE CABINET
29
TROUBLESHOOTING
29 – 30
SERVICE PARTS
31
CONTENTS
4
Top Valence Cover adds
16.0” to overall height
DIMENSIONS RSC 6
5
Model
RSC6 (RAC)
Product Temperature
Maintain product temperature at or below 41°F
Environmental Conditions
NSF/ANSI 7 Type II Standard, maximum indoor 80°F, relative humidity 54%
External Dimensions Width
73.5”
Depth
36.1”
Height
75.6” (91.6” with Valence)
Structure Outer / Inner Box
Powder coated steel / zinc coated steel
Insulation
Rigid insulating foam
Color
Internal: Black, External: Black (Optional: White/White available)
Shelves
14 shelves (7 per side), adjustable powder coated steel frame, glass inserts standard (Optional: metal inserts)
Electrical Parts 115/60/1 (3 Amp)
Fan Motor
ECM high efficiency
Lighting
LED
Solenoid Valve
Hermetic direct acting solenoid valve for refrigeration (24V DC)
Pipe Size of Connection Point
Liquid Line
3/8” OD
Suction Line
5/8” OD
Refrigerant
R404A standard (Optional: R410A)
Evaporator
Fin tube type
Expansion Valve
External equalized automatic thermal expansion valve
Controller
Digital programmable controller with Modbus communication protocol
Casters
(4) 2” Casters
Drain Pipe Dimensions
1.5” NPT Male Connector
Thermometer
Product simulation thermometer
Internal Volume
41.46 ft³
Weight
598 lb.
Noise
Less than 65 dB at 4 ft.
Agency Approvals
ETL File #4007858 Conforms to ANSI/UL 471, NSF Conforms to ANSI Std 7 Type II
SPECIFICATIONS RSC 6
NOTE: The manufacturer reserves the right to make product improvements and change specifications without notice
6
Top Valence Cover adds
16.0” to overall height
DIMENSIONS RSC 4
7
Model
RSC4 (RAC)
Product Temperature
Maintain product temperature at or below 41°F
Environmental Conditions
NSF/ANSI 7 Type II Standard, maximum indoor 80°F, relative humidity 54%
External Dimensions Width
49.9
Depth
36.1”
Height
75.6” (91.6” with Valence)
Structure Outer / Inner Box
Powder coated steel / zinc coated steel
Insulation
Rigid insulating foam
Color
Internal: Black, External: Black (Optional: White/White available)
Shelves
7 shelves, adjustable powder coated steel frame, glass inserts standard (Optional: metal inserts)
Electrical Parts 115/60/1 (3 Amp)
Fan Motor
ECM high efficiency
Lighting
LED
Solenoid Valve
Hermetic direct acting solenoid valve for refrigeration (24V DC)
Pipe Size of Connection Point
Liquid Line
3/8” OD
Suction Line
5/8” OD
Refrigerant
R404A standard (Optional: R410A)
Evaporator
Fin tube type
Expansion Valve
External equalized automatic thermal expansion valve
Controller
Digital programmable controller with Modbus communication protocol
Casters
(4) 2” Casters
Drain Pipe Dimensions
1.5” NPT Male Connector
Thermometer
Product simulation thermometer
Internal Volume
27.75 ft³
Weight
405 lb.
Noise
Less than 65 dB at 4 ft.
Agency Approvals
ETL File #4007858 Conforms to ANSI/UL 471, NSF Conforms to ANSI Std 7 Type II
SPECIFICATIONS RSC 4
NOTE: The manufacturer reserves the right to make product improvements and change specifications without notice
8
Top Valence Cover adds
16.0” to overall height
DIMENSIONS RSC 3
9
Model
RSC3 (RAC)
Product Temperature
Maintain product temperature at or below 41°F
Environmental Conditions
NSF/ANSI 7 Type II Standard, maximum indoor 80°F, relative humidity 54%
External Dimensions Width
37.9
Depth
36.1”
Height
75.6” (91.6” with Valence)
Structure Outer / Inner Box
Powder coated steel / zinc coated steel
Insulation
Rigid insulating foam
Color
Internal: Black, External: Black (Optional: White/White available)
Shelves
7 shelves, adjustable powder coated steel frame, glass inserts standard (Optional: metal inserts)
Electrical Parts 115/60/1 (3 Amp)
Fan Motor
ECM high efficiency
Lighting
LED
Solenoid Valve
Hermetic direct acting solenoid valve for refrigeration (24V DC)
Pipe Size of Connection Point
Liquid Line
3/8” OD
Suction Line
5/8” OD
Refrigerant
R404A standard (Optional: R410A)
Evaporator
Fin tube type
Expansion Valve
External equalized automatic thermal expansion valve
Controller
Digital programmable controller with Modbus communication protocol
Casters
(4) 2” Casters
Drain Pipe Dimensions
1.5” NPT Male Connector
Thermometer
Product simulation thermometer
Internal Volume
20.73 ft³
Weight
368 lb.
Noise
Less than 65 dB at 4 ft.
Agency Approvals
ETL File #4007858 Conforms to ANSI/UL 471, NSF Conforms to ANSI Std 7 Type II
SPECIFICATIONS RSC 3
NOTE: The manufacturer reserves the right to make product improvements and change specifications without notice
10
Electrical service installation should only be performed by qualified, licensed Electricians.
Mechanical service should only be performed by qualified, licensed Service Technicians.
Use adequate equipment when moving the Refrigerated Showcase (RSC).
Test for proper grounding to reduce the risk of electrical shock and fire.
High voltage is present in the RSC. Disconnect power before servicing.
Use only fully trained service technicians for power-on servicing.
Use only authorized replacement parts.
Be aware of inherent dangers in rocking or tipping the RSC.
Lines are pressurized with nitrogen. Use caution when opening lines.
Use refrigeration lines with adequate wall thickness to handle refrigeration pressures.
Replacement fuse must have identical ratings as the fuse being replaced.
If glass cracks or breaks, discard food items, and thoroughly remove all glass fragments.
Do not place objects on top of the RSC that can fall or spill.
The RSC is designed for indoor use only, in a controlled environment that typically does not exceed 80ºF (27ºC). Check system airflow as described in this document to ensure food is maintained at required temperatures.
SAFETY PRECAUTIONS
11
1) Remove the crating materials
cardboard corner posts)
2) Slide the unit REARWARDS off pallet onto dolly(s) or loading
mules. Note: DO NOT use the unit casters to move the unit anywhere other than in its final installation location.
UNPACKING
from the unit (shipping straps, corner brackets, wood panels &
12
INITIAL SET-UP
The Model RSC Remote Refrigerated Showcase, when properly installed and maintained, is designed to provide years of trouble-free operation. This Operation & Installation Manual contains information necessary for proper installation, maintenance and cleaning of the unit.
If connecting 2 or more RSC units together, refer to separate RSC connection instructions provided with these units.
It is the responsibility of the installer to ensure the unit is installed and working properly. The following instructions provide step-by-step set-up, piping, condensate drain connections, wiring, start-up, performance and maintenance guidelines.
For Parts or Technical Service, please call: 1-800-344-7216 or FAX: 1-800-541-5684 or email:
customerservice@vendoco.com
Additional reference manuals can be obtained at www.vendoco.com
CABINET SET-UP
Step 1: Choose a location for your new refrigerated display case. Avoid placing the cabinet near equipment that
releases heat. Avoid direct sunlight. To protect all electrical parts, do not place the cabinet where it will be subjected to rain, splashed liquid, or excessive humidity.
Step 2: Check the airflow around the cabinet, since strong airflow may displace the cooled air in the Showcase.
Place the cabinet where the airflow speed is less than 60 ft/min. Also, avoid areas subject to strong winds (see figures 1-7).
Loading...