Topcon FC-1000 Instruction Manual

Thank you for purchasing the TOPCON Data Collector FC-1000. For superior product performance, please read this instruction manual carefully and keep it in a convenient place for future reference.
GENERAL HANDLING PRECAUTIONS
•Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.
•Always make sure instrument is dry before putting it in the soft case. Never store a damp instrument.
•Do not leave the instrument under strong sunlight for a long time. It may cause the instrument to malfunction.
DISPLAY FOR SAFE USE
INSTRUCTION MANUAL
DATA COLLECTOR
• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to equipment and structure or furnishings.
Display Meaning
WARNING
Ignoring or disregard of this display may lead to the danger of death or serious injury.
CAUTION
Ignoring or disregard of this display may lead to personal injury or physical damage.
WARNING
• The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
• Battery can cause outbreak of fire.
Do not use any other type of charger other than the one specified.
• Risk of fire or electric shock.
Do not use any power voltage except the o ne given on manufacturers instructions.
CAUTION
• Do not allow skin or clothing to come into contact with acid from the batter­ies, if this does occur then wash off with copious amounts of water and seek
• Do not connect or disconnect equipment with wet hands, you are at risk of electric shocks if you do!
• Do not touch the charger, AC-DC converter or heating part of the instrument for a long period while charging the battery. There is a risk of low-temperature burn.
Exceptions from Responsibility
1
The user of this product is expected to fol low all operating instructions and make periodic checks of the product’s performance.
2
The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
3
The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
4
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an un usable product.
5
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than e xplained in the user manual.
6
The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products.
NOMENCLATURE AND FUNCTIONS
SAFETY CAUTIONS
WARNING
• There is a risk of fire, electric shock or physical harm if you attempt to disas­semble or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only!
• May ignite explosively.
Never use an instrument near flammable gas, l iquid matter, and do not use in a coal mine.
• High temperature may cause fire.
Do not cover the charger while it is charging.
• Risk of fire or electric shock.
Do not use a wet battery or charger.
• Battery can cause explosion or injury.
Do not dispose in fire or heat.
• To reduce the risk of hazards, use only CSA/UL certified power supply cord set, cord is Type SPT-2 or heavier, minimum No.18 AWG copper, one end is pro­vided with a moulded-on male attachment plug cap (with a specified NEMA cofiguration), and the other end is provided with a moulded-on female connec­tor body (with a specified IEC non-industrial type configuration).
FC-1000
Function key
Power key
Hook for neckstrap
Microphone
Speaker
Battery cover
Hard reset switch
Inside the cover
Hook for handstrap
AC adapter, external battery Connector
RUN Charge LED
Serial COM2 (Total Station)
Serial COM1
USB Connector (TYPE A)
CF slot
CF slot cover
Screw
To tighten or loosen the screw, use a coin.
CF card
CF card eject button
To eject the CF card, press the button.
Handstrap
Screw
To tighten or loosen the screw, use a coin.
Display and Touch screen
Hook for handstrap
Hook for tripod
CONNECTORS
Serial COM1
No.1 DCD (IN)
No.2 RXD (IN)
No.3 TXD (OUT)
No.4 DTR (OUT)
No.5 GND
No.6 DSR (IN)
No.7 RTS (OUT)
No.8 CTS (IN)
No.9 RI (IN)
No.1 GND
No.2 CTS (IN)
No.3 TXD (OUT)
No.4 RXD (IN)
No.5 RTS (OUT)
No.6 VDD (IN)
Serial COM2
(Total Station)
USB Connector (Type A)
No.1 VDD
No.2 V-
No.3 V+
No.4 GND
FC-1000
Enter key
Escape key
Cursor keys
TAB key
1 FC-1000 Instrument .................... 1set
2 BT-59Q Battery .......................... 2pcs.
3 Battery charger BC-29 ................ 1pc.
4 AC-DC converter AD-9B*
1)
...... 1pc.
5 Instruction manual ...................... 1vol.
6 Handstrap .................................... 1pc.
7 Neckstrap .................................... 1pc.
8 Soft case. ..................................... 1pc.
9 Stylus pen.................. .................. 1pc.
10 Stylus pen holder......................... 1pc.
11 Display protection sheet.............. 3pcs.
12 Interface cable A-21.................... 1pc.
13 End user license agreement......... 1pc.
STANDARD PACKAGE COMPONENTS
Upon opening, make sure that all the followings are included.
American model
1 FC-1000 Instrument... ................. 1set
2 BT-59Q Battery .......................... 2pcs.
3 Battery charger BC-29 ................ 1pc.
4 AC-DC converter AD-7C*
1) ...... 1pc.
5 Instruction manual ...................... 1vol.
6 Handstrap .................................... 1pc.
7 Neckstrap .................................... 1pc.
8 Soft case........ .............................. 1pc.
9 Stylus pen.................................... 1pc .
10 Stylus pen holder ........................ 1pc.
11 Display protection sheet.............. 3pcs.
12 End user license agreement......... 1pc.
European model
*
1)
AD-9B
is for AC 120V use,
AD-7C
is for AC 230V use.
2)
Components are different by the
markets.
Shortcut Keys
Display Contrast
Press
[Func]+[ ]
or
[Func]+[ ]
Front Light
ON/OFF
[Func]+[ . ]
Ctrl Key [Func]+[S.P]
Soft Reset
[Shift]
+
[Func]
+
[ESC]
Windows Start
Menu
[Func]+[ / ]
Shortcut
Commands
Press [Alt]
+
Tap on an item is the same as a right click on a mouse. A menu is displayed contain­ing commands spe­cific to the item.
Windows CE
Task Manager
Press [Alt]
+
[TAB] to switch to another active pro­gram or to END Tas k o n running pro­gram(s).
Stylus pen holder
Stylus pen
About Stylus Pen Holder
Stick the stylus pen holder and hold a stylus pen as shown below. When sticking the holder, wipe the attachment surface of the instrument finely.
Microprocessor :
SH7750S
Processor speed :
162MHz
MIPS :
300MIPS
Operating system :
Microsoft Windows CE Ver. 3.0
Memory :
32MB / 64MB RAM with flash ROM 2MB 32MB / 64MB / 128MB flash disk (Internal)
RAM retention :
Li-rechargeable battery(65mAh)-backed for data when main battery not present
Display :
320x240 QVGA (monochrome) STN Reflective type Temperature compensation
Illumination :
Front light (CCFL)
Key board :
56 key keyboard with separate alpha and numeric
Pen touch screen :
Resistive touch screen/passive Pen digitization
Interface :
RS-232C serial (6 pin) RS-232C serial (D-sub 9) USB(1.1) Compact flash : Type I / Type ll (Based on Compact Flash)
External power :
8.4V to 20V Available run charge (11V to 20V)
Audio :
Sealed Speaker (mono) Sealed Microphone
Durability :
IP66 (Based on the standard IEC 60529) *1)
*1) With the connector and slot covers
Operation Temperature
:
-20°C to +50°C (-4
°F to +122°F)
Storage Temperature
:
-30°C to +60°C (-22
°F to +140°F)
Protection against shock
:
Designed to protect falling on the hard surface from 1.0m above the ground.
EMC :
CE, FCC
Integral heater :
Auto/Off
Battery BT-59Q :
Li-ion rechargeable Battery 7.4V 1800mAh (This battery does not contain mercury.)
Rating :
8 hours
Charging time :
Approx. 3.0 hours with BC-29 Approx. 6.0 hours with AD-9B/7C
Dimensions :
255x130x61.5(mm)
Wei ght :
0.8kg(with battery)
Battery Installation
1
Remove the handstrap from the FC-1000.
2
Using a coin, loosen the screw on the battery cover.
3
Remove the battery cover.
4
Install the battery pack.
5
Using a coin, install the battery cover. Tighten the screw
firmly.
STORAGE PRECAUTIONS
SPECIFICATIONS
Always clean the instrument after use. Use a clean cloth moistened with neutral detergent or water. Never use an abrasive cleaner, ether, thinner benzene, or other solvents. Always make sure the instrument is completely dry before storing. Dry any moisture with a soft, clean cloth.
FC-1000 64837 90030 0303 (4D)
TRANSMITTION DATA TO THE PC
1
Turn on the PC and the FC-1000.
2
Connect the FC-1000 to your PC with the interface cable A-21 as shown below.
The FC-1000 will prompt “Connecting to Host”.
3
The PC will prompt for setting up a partnership or setting up as a guest.
When working as a guest, you can browse the files on your FC-1000 and copy or move information. Choose [ESC] to set up as a guest. Once a connection has been established, the icon will appear on your PC.
4
Click on [Explore] to move or copy files between the PC and the FC-1000.
Serial COM1
PC
Interface cable A-21
FC-1000
COM port
Reference software for Connectivity
See the WEB page as follows. www.microsoft.com/mobile/pocketpc/downloads/activesync35.asp
The FC-1000 has an external CF slot, so the files in the FC-1000 can move to your PC through the CF card.
CF slot (TYPE I/
CF card and PCMCIA adapter
PC with PCMCIA slot
FC-1000
PREPARATION FOR USE
There are two ways to charge the battery as follows.
Battery Charging (Using BC-29)
1
Install the battery on the BC-29.
2
Plug the power cord in an outlet.(AC-120V or 230V) Charging is
completed after approximately 3 hours.
The Charge LED of BC-29 will indicate charging status;
Red ON : Charging. Green ON : Charging completed. Red Flashing : Charging error. On Solid : Pre charging.
Battery Charging (Using AD-9B/7C)
1
After installing the battery, plug the connector of AD-9B/7C in the FC-
1000.
2
Plug the AD-9B/7C in an outlet. Then the run charge LED will light.
Charging is completed after approximately 6 hours. The display can be turned on or off by the power key.
The Run Charge LED of FC-1000 will indicate charging status;
Red ON : Charging. Green ON : Charging completed. Red Flashing : Charging error.
Be sure to turn the FC-1000 power OFF when removing the battery, since the data will be lost.
Battery
Adjusting Touch Screen
1
Turn on the instrument after hard-reset or tap [Start] [Setting] [Control Panel] [Stylus].
2
Using a stylus pen, touch the center of the cross hairs. (5 points)
3
After touching all corsairs, press [ENT] key.
(Use an accessory stylus pen to touch a screen. Do not use neither a ball-point pen nor pencil.
Stylus pen
Corsairs
Touch Screen
Note
1)Recharging should take place in a room with an am bient temperature range of +10°C to +40°C (+50°F to +104°F).
2)The battery source will discharge when stor ed and should be checked before using with instrument .
3)Be sure to charge a stored battery source ev ery 15 days and store in a place at 30°C and below when it will not used for a long period. If you allow the battery to be completely discharged, it will have an effect on the overall performance for proper charging in the futur e.
4)The charger may develop heat while charging, there is no problem of it.
5)If charging is done at high temperature, charging ti me of the battery may take longer.
Interface Cable
CF Card
BC-29
BT-59Q
AD-9B/7C
RUN Charge LED
Connector
Charge LED
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
TOPCON POSITIONING SYSTEMS, INC.
5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A. Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691,
U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON MIDWEST
891 Busse Road, Elk Grove Village, IL 60007, U.S.A. Phone: 847-734-1700 Fax: 847-734-1712
TOPCON EUROPE B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands. Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com
TOPCON BELGIUM
Preenakker 8, 1785 Merchtem, Belgium Phone: 052-37.45.48 Fax: 052-37.45.79
TOPCON DEUTSCHLAND G.m.b.H.
Weidkamp 180, 45356 Essen, GERMANY Phone: 0201-8619-100 Fax: 0201-8619-111 ps@topcon.de www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France. Phone: 33-1-41069490 Fax: 33-1-47390251 topcon@topcon.fr
TOPCON ESPAÑA S.A.
HEAD OFFICE
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, Spain. Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
MADRID OFFICE
Avenida Burgos, 16E, 1∞28036, Madrid, Spain. Phone: 91-302-4129 Fax: 91-383-3890
TOPCON SCANDINAVIA A. B.
Neongatan 2 S-43151 Mölndal, SWEDEN Phone: 031-7109200 Fax: 031-7109249
TOPCON (GREAT
BRITAIN) LTD.
HEAD OFFICE
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K. Phone: 44-1635-551120 Fax: 44-1635-551170 survey.sales@topcon.co.uk laser.sales@topcon.co.uk
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, Pantech Industrial Complex, #07-01, Singapore 128381 Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
408 Victoria Road, Gladesville, NSW 2111, Australia Phone: 02-9817-4666 Fax: 02-9817-4654 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
77/162 Sinn Sathorn Tower, 37th Fl., Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand. Phone: 662-440-1152~7 Fax: 662-440-1158
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
Lot 226 Jalan Negara 2, Pusat Bandar Taman Melawati, Taman Melawati, 53100, Kuala Lumpur, Malaysia. Phone: 03-41079801 Fax: 03-41079796
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea. Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road, Shatin, N.T., Hong Kong Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
TOPCON CORPORATION BEIJING OFFICE
Room No. 962 Poly Plaza Building, 14 Dongzhimen Nandajie, Dongcheng District, Beijing, 100027, China Phone: 10-6501-4191~2 Fax: 10-6501-4190
TOPCON CORPORATION BEIRUT OFFICE
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
P.O.Box 28595, 102, Al Naily Bldg., 245 Abu Hail Road, Deira,Dubai,UAE Phone: 971-4-2696511 Fax: 971-4-2695272
Back-Up Battery
•The back-up battery built in FC-1000 needs to be charged approximately 24hrs. before using it for the first time after
purchase. Connect the AD-9B/7C or install the f ully charged BT-59Q battery to FC-1000 in order to charge the back-up battery.
•Leaving FC-1000 without the BT-59Q battery or AD-9B/7C for more than an hour will cause the memorized data to
be lost, due to low voltage of the back-up battery. Connect the BT-59Q battery or AD-9B/7C as soon as possible.
Note: The instrument may develop heat while charging, there is no problem of it.
EMC NOTICE
FCC conditions
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interferen ce received, including
interference that may cause undesired op eration.
Loading...