Error code 1: AC heater current is measured to be 75% below nominal current
Input supplied at the fridge is stable and included between
210V and 240V
Yes
Check if the 5A fuse is OK
Yes
Check if the heater impedance is correct
(in Ohm)
Yes
Replace
Power board
SES version part 631219 or
EES version Part 631220
No
No
Type Min Max
N90-N97-
N98-N100-
312 380
N104-N109-
N112-N115
N145-N150-
218 266
N175-N180
AC Input issue
Change the fuse
(part 624030)
No
Replace the AC
heater
(see Spare Parts
List)
05/09
1/1 |
6.301 |
Error code 2: DC heater current is measured to be 75% below nominal current
Input supplied at the fridge is stable and included between 10.5V and 15.4V
Yes
Check if all the connections are OK
Yes
Check if the D+ input is included between 10.5V and 15.4V
Yes
Check if the 20A fuse is OK
Yes
Check if the heater impedance is correct
(in Ohm)
Yes
Replace Power board
SES version part 631219 or
EES version Part 631220
6.302
No
No
No
No
Type Min Max
N90-N97-
N98-N100-
0.93 1.13
N104-N109-
N112-N115
N145-N150-
0.88 1.08
N175-N180
1/1
DC input issue
Restore the connections
D+ input issue
Change the fuse
(part 626996)
No
Replace the DC
heater
(see Spare Parts
List)
6.302 |
1/1 |
05/09
05/09
Error code 3: AC heater is ON when it should be OFF
Input supplied at the |
No |
AC input issue |
|
fridge is stable and |
|||
|
|
||
included between |
|
|
|
|
|
||
210V and 240V |
|
|
Yes
Yes
Replace
Power board
SES version part 631219 or
EES version Part 631220
Error code 4: DC heater is ON when it should be OFF
Input supplied at the |
No |
DC input issue |
|
fridge is stable and |
|||
|
|
||
included between |
|
|
|
|
|
||
9.5V and 15.5V |
|
|
|
Yes |
|
|
|
|
|
|
|
Check if the D+ |
No |
D+ input issue |
|
Yes |
|||
input is included |
|
|
|
between 9.5V and |
|
|
|
|
|
||
15.5V and if polarity |
|
|
|
is correct |
|
|
|
Yes |
|
|
Replace
Power board
SES version part 631219 or
EES version Part 631220
05/09
1/1 |
6.303/6.304 |
Error code 5: Senses flame when gas should be OFF
Check if the gas |
No |
Replace the gas |
valve works |
|
valve |
|
|
|
Yes |
|
|
|
|
|
Replace |
|
|
Power board |
|
|
SES version |
|
|
part 631219 |
|
|
or |
|
|
EES version |
|
|
Part 631220 |
|
|
Error code 6: Senses gas output terminal ON when should be OFF
Replace Power board: |
- SES version part 631219 |
|
- EES version part 631220 |
|
|
Error code 7: Senses gas output terminal OFF when should be ON
Replace Power board: |
- SES version part 631219 |
|
- EES version part 631220 |
|
|
6.305/6.306/6.307 |
1/1 |
05/09
Error code 8: AC mains supply is below 20% nominal
Input supplied at the |
No |
AC input issue |
|
fridge is stable and |
|||
|
|
||
included between |
|
|
|
|
|
||
210V and 240V |
|
|
|
Yes |
|
|
|
|
|
|
|
Check if the 5A |
No |
Change the fuse |
|
glass fuse is OK |
|
(part 624030) |
|
|
|
|
|
Yes |
|
|
|
|
|
|
|
Replace |
|
|
|
Power board |
|
|
|
SES version |
|
|
|
part 631219 |
|
|
|
or |
|
|
|
EES version |
|
|
|
Part 631220 |
|
|
05/09
1/1 |
6.308 |