Tascam DA-P1 Technical Information

Page 1 of 1
9711
DA-30MK2, DA-P1, R-9, Capstan Thrust Bearing
20th June 1997
Symptom: Capstan motor does not rotate. Error 02 is indicated in the display window. Cause: Wear of the capstan thrust bearing (Ref 4-37, S/M). The Rotor touches to the motor coil. Solution: Change the material of the thrust bearing. Duration is improved.
New thrust bearing, P/No. V000592-00A has been introduced in the following products: DA-30Mk2/R/9 S/No. 390501 and higher DA-P1 S/No. 210361 and higher
When the thrust bearing is replaced, follow the procedure indicated below.
1 Dissolve the screw lock with alcohol. 2 Replace the old thrust bearing with new, P/No. V000592-00A. Note: Old part and new part can be identified by color difference. Old part is gray color and new part is black color. 3 Insert a jig spacer (0.25 t), P/No. J003856-00A between rotor and coil as shown below. 4 Adjust the height of the rotor by rotating the thrust bearing. 5 Pull out the spacer. 6 Secure the thrust bearing with screw lock.
Thrust Bearing P/No. V000592-00A
Jig Spacer (0.25 t)
P/No. J003856-00A
Rotor
Coil
Jig Spacer (0.25 t)
P/No. J003856-00A
4A2175