LIMITED WARRANTY
Snorkel further warrants the structural components; specifically, the mainframe chassis, turntable, booms and scissor arms, of each new machine manufactured by it to be free from defects in material and workmanship for an additional period of four (4) years. Any such part or parts which, upon examination by the Snorkel Service Department, are found to be defective will be replaced or repaired by Snorkel through its local Authorized Dealer at no charge; however, any labor charges incurred as a result of such replacement or repair will be the responsibility of the Customer or Dealer.
The Snorkel Service Department must be notified within forty-eight (48) hours of any possible warranty situation during the applicable warranty period. Personnel performing warranty repair or replacement must obtain specific approval by Snorkel Service Department prior to performing any warranty repair or replacement.
Customer and Dealer shall not be entitled to the benefits of this warranty and Snorkel shall have no obligations hereunder unless the “Pre-Delivery and Inspection Report” has been properly completed and returned to the Snorkel Service Department within ten (10) days after delivery of the Snorkel product to Customer or Dealer’s rental fleet. Snorkel must be notified, in writing, within ten (10) days, of any machine sold to a Customer from a Dealer’s rental fleet during the warranty period.
At the direction of the Snorkel Service Department, any component part(s) of Snorkel products to be replaced or repaired under this warranty program must be returned freight prepaid to the Snorkel Service Department for inspection. All warranty replacement parts will be shipped freight prepaid (standard ground) from the Snorkel Service Department or from Snorkel’s Vendor to Dealer or Customer.
REPLACEMENT PARTS WARRANTY
Any replacement or service part made or sold by Snorkel is not subject to the preceding Limited Warranty beyond the normal warranty period of the machine upon which the part was installed.
THIS WARRANTY EXCLUDES AND SNORKEL DOES NOT WARRANT:
1. Engines, motors, tires and batteries which are manufactured by suppliers to Snorkel, who furnish their own warranty. Snorkel will, however, to the extent permitted, pass through any such warranty protection to the Customer or Dealer.
2. Any Snorkel product which has been modified or altered outside Snorkel’s factory without Snorkel’s written approval, if such modification or alteration, in the sole judgment of Snorkel’s Engineering and/or Service Departments, adversely affects the stability, reliability or service life of the Snorkel product or any component thereof.
3. Any Snorkel product which has been subject to misuse, improper maintenance or accident. “Misuse” includes but is not limited to operation beyond the factory-rated load capacity and speeds. “Improper maintenance” includes but is not limited to failure to follow the recommendations contained in the Snorkel Operation, Maintenance, Repair Parts Manuals. Snorkel is not responsible for normal maintenance, service adjustments and replacements, including but not limited to hydraulic fluid, filters and lubrication.
4. Normal wear of any Snorkel component part(s). Normal wear of component parts may vary with the type application or type of environment in which the machine may be used; such as, but not limited to sandblasting applications.
5. Any Snorkel product that has come in direct contact with any chemical or abrasive material.
6. Incidental or consequential expenses, losses, or damages related to any part or equipment failure, including but not limited to freight cost to transport the machine to a repair facility, downtime of the machine, lost time for workers, lost orders, lost rental revenue, lost profits or increased cost.
This warranty is expressly in lieu of all other warranties, representations or liabilities of Snorkel, either expressed or implied, unless otherwise amended in writing by Snorkel’s President, Vice President-Engineering, Vice President-Sales or Vice President-Marketing.
SNORKEL MAKES NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THIS LIMITED WARRANTY. SNORKEL MAKES NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND DISCLAIMS ALL LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO INJURY TO PERSONS OR PROPERTY.
The Customer shall make all warranty claims through its local Authorized Dealer and should contact the Dealer from whom the Snorkel product was purchased for warranty service. Or, if unable to contact the Dealer, contact the Snorkel Service Department for further assistance.
Ef fec tive July 1995

Electrical Hazard

DANGER
Electrical Hazard Warning
THE EPV16J AERIAL WORK PLATFORM
IS NOT ELECTRICALLY INSULATED.
If the plat form, booms, or any other con duc tive part of a EPV16J con tacts a high-volt age elec tri cal con duc ­tor, the re sult can be SERIOUS INJURY or DEATH for per sons on or near the ma chine.
GO NO CLOSER THAN THE MINIMUM SAFE APPROACH DISTANCES
(M.S.A.D) - AS OUTLINED IN TABLE 1. AND FIGURE 3.,
ON THE NEXT PAGE.
Be sure to al low for sag and sway in the wires and the work plat form.
If a EPV16J co mes in con tact with a live elec tri cal con duc tor, the en tire ma chine can be charged.
If that hap pens, you should re main on the ma chine and not con tact any other struc ture or ob ject within reach. That in cludes the ground, ad ja cent build ings, poles, and any ob ject not a part of the EPV16J.
Such con tact could make your body a con duc tor to the other ob ject cre at ing an elec tri cal shock haz ard re ­sult ing in SERIOUS INJURY or DEATH.
DO NOT at tempt to en ter or leave the EPV16J un til you are sure the elec tric ity has been turned off.
If a EPV16J is in con tact with a live con duc tor, the plat form op er a tor MUST warn oth ers on the ground in the vi cin ity of the EPV16J to STAY AWAY from the ma chine, since their bod ies can also form a path for elec tric ity to ground thus cre at ing an elec tri cal shock haz ard with pos si ble ELECTROCUTION and
DEATH.
DO NOT at tempt to op er ate the EPV16J ground con trols when the plat form, booms, or any other con duct -
ing part of a EPV16J is in con tact with elec tri cal wires or if there is an im me di ate dan ger of such con tact.
Re gard all con duc tors as en er gized.
Per son nel work ing on or near a EPV16J must be con tin u ously aware of elec tri cal haz ards, rec og niz ing that SERIOUS INJURY or DEATH can re sult if con tact with an elec tri cal wire does oc cur.
EPV16J – 11089A page - i
Electrical Hazard
Denotes prohibited zone
Danger:
Caution:
- Do not allow machine personnel or conductive materials inside prohibited zone.
- Maintain M.S.A.D. From all energised lines and parts as well as those shown.
- Assume all electrical parts and wires are energised unless known otherwise.
- Diagrams shown are only for purposes of illustrating M.S.A.D. Work positions, not all work positions.
Minimum Safe Approach Distance
The EPV16J is an all metal boom, NOT ELECTRICALLY INSULATED, ae rial work plat form. DO NOT op ­er ate it near ELECTRICAL con duc tors. Re gard all con duc tors as be ing en er gized. Use the ta ble and il lus ­tra tion be low to de ter mine safe clear ance from elec tri cal con duc tors. (Ta ble 1 and Fig ure 3, be low, are from ANSI/SIA A92.5–1992 Stan dard, re printed with per mis sion of Scaf fold In dus try As so ci a tion.)
Table 1 - (M.S.A.D.)
Minimum Safe Approach Distance
to energized (exposed or insulated power lines)
Voltage range Minimum safe approach distance
(phase to phase)
0 to 300V
over 300v to 50kv
over 50kv to 200kv
over 200kv to 350kv
over 350kv to 500kv
over 500kv to 750kv
over 750kv to 1000kv
(Feet) (Meters)
Avoid contact
10
15
20
25
35
45
3.05
4.60
6.10
7.62
10.67
13.72
Figure 3 - (M.S.A.D.)
page - ii EPV16J – 11089A

Introduction

DANGER
CAUTION
DANGER
The most im por tant chap ter in this man ual is "Safety" chap ter 1. Take time, now, to study it closely. The in for ma tion in chap ter 1, might save your life or pre vent se ri ous in jury.
Signs
The fol low ing three con ven tions are used through ­out this man ual.
1. Danger sign
means: Attention! Become alert! Your safety is involved.
2. Caution sign
means one of two things: (1) an action, about to be performed, is potentially hazardous and might result in minor personal injury if not done correctly, or (2) an action, about to be performed, can harm the EPV16J if not done correctly.
3. Note sign
Operation rules
The fol low ing rules will help en sure the safety of per son nel and help pre vent need less down time be cause of dam aged equip ment.
1. Only TRAINED and AUTHORIZED operators shall be permitted to operate the equipment.
2. All manufacturer’s operating instructions and safety rules and all employers’ safety rules and all OSHA and other government safety rules must be strictly adhered to.
3. Repairs and adjustments shall be made only by QUALIFIED TRAINED maintenance personnel.
4. No modification shall be made to the equipment without prior written consent of the Snorkel Engineering Department.
5. You must make a pre-start inspection of the EPV16J at the beginning of each shift. A malfunctioning machine must not be used.
6. You must make an inspection of the work place to locate possible hazards before operating the EPV16J.
NOTE
means: The information following is to assist you in either the proper steps to take for an action or as additional information concerning your present situation, but does not indicate a dangerous condition to either you or the EPV16J unit.
Qualified operators
The EPV16J ae rial plat form has built in safety fea ­tures and has been fac tory tested for com pli ance with Snor kel spec i fi ca tions and in dus try stan dards. How ever, any per son nel lift ing de vice can be po ­ten tially dan ger ous in the hands of un trained or care less op er a tors.
Training is vi tally im por tant and MUST be done un ­der the di rec tion of a QUALIFIED per son. You must dis play pro fi ciency in knowl edge and ac tual op er a ­tion of the EPV16J.
Be fore op er a tion of the EPV16J you must read and un der stand the op er at ing in struc tions in this man ­ual as well as the de cals, warn ings, and in struc ­tions on the ma chine it self.
Be fore op er at ing the EPV16J you must be AUTHORIZED by the per son in charge to do so.
DO NOT operate this equipment unless you are TRAINED and AUTHORIZED and have read and thoroughly understand all of the information given in this Operator’s Manual and on all DANGER and CAUTION signs on the machine. Misuse of this machine can result in DEATH or SERIOUS INJURY.
Maintenance
Ev ery per son who main tains, in spects, tests, or re ­pairs these ma chines, and ev ery per son su per vis ­ing any of these func tions, MUST be prop erly trained.
This Op er a tor’s Man ual pro vides a daily in spec tion pro ce dure that will help you keep your EPV16J in good op er at ing con di tion. DO NOT per form other main te nance un less you are a TRAINED me ­chanic, QUALIFIED to work on the EPV16J. Call QUALIFIED main te nance per son nel if you find prob lems or mal func tions.
DO NOT mod ify this ma chine with out writ ten ap ­proval from the En gi neering De part ment of Snor ­kel.
In for ma tion con tained in this man ual con cerns only cur rent EPV16J's, and the right is re served to make changes at any time with out ob li ga tion.
EPV16J – 11089A page - iii
Introduction
DANGER
Responsibilities of parties
It is im per a tive that all own ers and us ers of the EPV16J read, un der stand, and con form to all ap pli ­ca ble reg u la tions. Ul ti mate com pli ance to OSHA reg u la tions is the re spon si bil ity of the em ployer us ­ing the equip ment.
ANSI Stan dard A92.2-1992 clearly iden ti fies re quire ments of all par ties who might be in volved with Boom-Supported El e vating Work Plat forms.
AUSTRALIAN / NZ STANDARD 2550-10 1994 Also iden ti fies the re quire ments of all par ties who might be in volved with Boom-Supported El e vating Work Plat forms.
A re print of the “Man ual of Re spon si bil ities for Dealers, Owners, Users, Op er a tors, Les sors and Les sees of ANSI/SIA A92.5-1992 Boom Sup ­ported El e vating Work Plat forms” is avail able from Snor kel deal ers or from the fac tory upon re quest.
Additional information
For ad di tional in for ma tion, con tact your lo cal dealer.
Snor kel 2/26 Red fern Street Wether ill Park NSW 2164 Aus tra lia
Snor kel PO Box 1041 Levin 5500 New Zea land
Copies are also avail able from the Scaf fold In dus ­try As so ci a tion, Inc., 14039 Sherman Way, Van Nuys, CA 91405-2599.
Options
The use of op tional equip ment is dis cussed in the “Op tions” chap ter 11.
The op tions you will find dis cussed there are:
1. Air line to platform.
2. Dual fuel.
3. Work lights.
4. Sandblast protection kit.
5. RCD/ELCB AC outlet.
6. Flashing light.
7. Platform rotator.
8. Self levelling stabilisers.
page - iv EPV16J – 11089A

Table of Contents

Electrical Hazard
Electrical Hazard Warning ..................i
Minimum Safe Approach Distance ...........ii
Table 1 - (M.S.A.D.) .....................ii
Figure 3 - (M.S.A.D.) ....................ii
Introduction
Signs .................................iii
Qualified operators.......................iii
Operation rules..........................iii
Maintenance............................iii
Responsibilities of parties .................iv
Options................................iv
Additional information ....................iv
Chapter 1. Safety
Safe Operation ........................1-1
Pre-start Inspection....................1-1
Work Place Inspection and Practices ......1-1
Electrocution .........................1-1
Tipover and Falling Hazards .............1-1
Crushing ............................1-2
General Safety Precautions ..............1-2
Personnel Precautions .................1-2
Operator General Precautions ...........1-2
Mounting and Dismounting Precautions ....1-2
Starting and Stopping Precautions ........1-2
Operating Precautions .................1-2
Operator Maintenance Precautions .......1-3
Fuel Handling Precautions ..............1-3
Safety Decals and Placards ..............1-3
Safety Placards and Decals Location .......1-4
Chapter 2. Safety Devices
Safety Device Information ................2-1
Emergency Stop Switches ...............2-1
At ground control box ..................2-1
At platform control box .................2-1
Other Safety Devices ...................2-1
Lanyard anchor points .................2-1
Gravity gate..........................2-2
Guardrails ...........................2-2
Foot switch ..........................2-2
Bubble level .........................2-2
RCD/ELCB AC outlet ..................2-3
Flashing light.........................2-3
Chapter 3. Specifications
General Specifications ..................3-1
Recommended Hydraulic Oil..............3-1
Engine Data...........................3-2
Overall Dimensions EPV16J ..............3-2
Booms identification ...................3-3
Nomenclature And Serial Numbers.........3-3
Right side view of machine ..............3-3
Left side view of machine ...............3-4
Chapter 4. Gauges
Hourmeter ............................4-1
Level Bubble ..........................4-1
Hydraulic Oil Level .....................4-1
Chapter 5. Shut-offs and Circuit Breakers
RCD/ELCB Outlet (option) ...............5-1
Main Circuit Breaker ....................5-1
Stabilisers ............................5-1
Chapter 6. Controls
Controls Description ....................6-1
Controls and Control Decals Locations ....6-1
Ground Control Box.....................6-2
Ground Control Box Controls ............6-3
Platform Control Box ....................6-4
Platform Control Box Controls ...........6-5
Chapter 7. Pre-operational Inspection
Pre-operational Inspection Table ..........7-1
Engine Cover..........................7-2
Engine Fuel Level ......................7-2
Fuel Tank Cap.........................7-2
Fuel Leaks............................7-2
Engine Oil Level .......................7-2
Wiring Harnesses ......................7-2
Battery Terminals ......................7-3
Battery Fluid Level......................7-3
Hydraulic Oil Level .....................7-3
Hydraulic Oil Leaks .....................7-3
Bolts and Fasteners ....................7-4
Structural Damage and Welds ............7-4
Lanyard Anchor Points ..................7-4
Platform Gravity Gate ...................7-4
Platform Guardrails .....................7-4
Flashing Light (option)...................7-5
Ground Control Switches ................7-5
Emergency Lower ......................7-5
Lower control box .....................7-5
Upper control box .....................7-5
Platform Control Switches ...............7-6
AC Outlet RCD/ELCB (option) ............7-6
Placards and Decals ....................7-6
Standard placards and decals ...........7-6
Inspection drawing ....................7-7
Chapter 8. Operation
Operating Procedures ...................8-1
Control Stations........................8-1
EPV16J – 11089A page - v
Table of Contents
Emergency Stopping ....................8-1
Operation Considerations ................8-1
Starting From Ground Control Box .........8-2
Stabiliser Operation.....................8-2
Setting the stabilisers ..................8-2
Raising the stabilisers ..................8-3
Starting From Platform Control Box ........8-3
Moving The Platform ....................8-4
From Ground Control Box...............8-4
From Platform Control Box ..............8-5
Securing for Day .......................8-6
Chapter 9. Emergency Operation
Emergency Operation Procedures .........9-1
Operation From Platform Control Box......9-1
Operation From Ground Control Box ......9-2
Chapter 10. Stowing and Transporting
Stowing .............................10-1
Upper boom latch ....................10-1
Lower boom lock pin ..................10-1
Chapter 11. Options
Air Line To Platform....................11-1
Dual Fuel ............................11-1
Work Lights ..........................11-1
Flashing Light ........................11-1
RCD/ELCB AC Outlet ..................11-1
Sandblast Protection Kit ................11-1
Platform Rotator ......................11-1
5Kv Insulation ........................11-1
Chapter 12. Fire Fighting & Chemical Control
Hazardous Components ................12-1
Battery, Lead/Acid (UN 2794) ...........12-1
Gasoline (UN 1203) ..................12-2
Hydraulic Oil (UN 1270) ...............12-3
Motor Oil (UN 1270) ..................12-3
Chapter 13. Operator's Troubleshooting
Troubleshooting.......................13-1
Operator Troubleshooting Chart .........13-1
page - vi EPV16J – 11089A
CAUTION
Safe Operation
The fol low ing safety in for ma tion is vi tally im por tant for safe op er a tion of the EPV16J. Fail ure to fol low these in struc tions can re sult in per sonal in jury or DEATH.
Pre-start Inspection
At the start of each work shift, the EPV16J shall be given a vi sual in spec tion and func tion test. See the “Pre-op er a tional In spec tion” chap ter 7, in this man ­ual for a list of items to in spect and test.
DO NOT operate the EPV16J unless you are trained and authorized, understand the operation characteristics of the EPV16J, and have inspected and tested all functions to be sure they are in proper working order.
Work Place Inspection and Practices
Do not use the EPV16J as a ground for weld ing. Ground to the work piece.
Be fore the EPV16J is used, and dur ing use, check the area in which the EPV16J is to be used for pos ­si ble haz ards such as, but not lim ited to:
1. Drop-offs or holes.
2. Side slopes.
3. Bumps and floor obstructions.
4. Debris.
5. Overhead obstructions and electrical conductors.
6. Hazardous locations.

Chapter 1. Safety

When mov ing the plat form, check the clear ance around the EPV16J to avoid con tact with struc tures or other haz ards. Al ways look in the di rec tion of mo tion.
Keep ground per son nel from un der the plat form when the plat form is raised.
Se cure all ac ces so ries, con tain ers, tools, and other ma te ri als in the plat form to pre vent them from ac ci den tally fall ing or be ing kicked off the plat form.
DO NOT en gage in any form of “horse play” or “stunt driv ing” while op er at ing the EPV16J.
DO NOT per mit rid ers on the ma chine any place other than on the plat form.
Re move all loose ob jects stored in or on the ma ­chine, par tic u larly in the plat form. Re move all ob ­jects which do not be long in or on the ma chine.
When other mov ing equip ment is in the area, take spe cial pre cau tions to com ply with lo cal reg u la ­tions re gard ing warn ings.
Never steady the plat form by po si tion ing it against an other plat form.
DO NOT op er ate an EPV16J that is not func tion ing prop erly, or has been dam aged, un til the ma chine has been re paired by a qual i fied main te nance per ­son.
DO NOT op er ate a EPV16J that does not have all its de cals and plac ards at tached and leg i ble.
Watch for by stand ers and never al low any one to be un der, or to reach through, the ma chine and its equip ment while op er at ing.
Use the rec om mended trans port de vice when load ing the ma chine.
7. Inadequate surface and support to withstand all load forces imposed by the aerial platform in all operating configurations.
8. Wind and weather conditions.
9. Presence of unauthorized persons.
10. Other possible unsafe conditions.
Be fore the EPV16J is used, de ter mine the haz ard clas si fi ca tion of any par tic u lar at mo sphere or lo ca ­tion ac cord ing to ANSI/NFPA 505-1987.
Any EPV16J op er ated in a haz ard ous lo ca tion must be ap proved and of the type re quired by ANSI/NFPA 505-1987.
A recommended safety practice is to have personnel that are trained in the operation of the emergency controls working in the immediate area of the EPV16J to assist the platform operator in the event of an emergency.
EPV16J – 11089A page 1 - 1
Electrocution
The EPV16J is an all metal boom, NON-INSULATED, ae rial work plat form. DO NOT op er ate it near ELECTRICAL con duc tors. Re gard all con duc tors as be ing en er gized.
DO NOT op er ate out side dur ing a thun der storm.
Tipover and Falling Hazards
DO NOT op er ate the EPV16J from a po si tion on trucks, trail ers, rail way cars, float ing ves sels, scaf ­folds, or sim i lar equip ment un less the ap pli ca tion is ap proved in writ ing by Snor kel.
If the platform or elevating assembly becomes caught, snagged, or otherwise prevented from normal motion by an adjacent structure or other obstacles such that control reversal does not free the platform, remove all personnel from the
Chapter 1. Safety
platform before attempts are made to free the platform using ground controls.
Un der nor mal work ing con di tions it is best not to trans fer from the plat form to an other struc ture or vice versa, un less that is the saf est way to do the job. Each sit u a tion must be judged sep a rately tak ­ing the work en vi ron ment into ac count. The fol low ­ing guide lines ap ply:
1. Where possible, place the work platform over a roof or walking structure to do the transfer.
2. Transfer your anchorage from one structure to another before you step across.
3. Remember, you might be departing the work platform to a structure where fall arrest is required.
4.
DO NOT climb the rails. Use the entrance.
All plat form oc cu pants MUST wear and use fall re ­straint. At tach fall re straints to the plat form lan yard an chor points.
DO NOT ex ceed the un re stricted plat form ca pac ity as in di cated on the ca pac ity plac ard at the en ­trance to the plat form.
ENSURE all four sta bi lizer foot plates are in firm con tact with the ground as laid out on page 1-1 “Work Place In spec tion and Prac tices”. DO NOT raise the boom if the EPV16J is on soft ground. Op ­er ate the boom only on a firm sur face ca pa ble of with stand ing all load forces im posed by the ae rial work plat form in all op er at ing con di tions.
Do Not carry loads from any point out side of the plat form.
Care shall be taken to pre vent rope, elec tric cords, and hoses, etc., from be com ing en tan gled in the ae rial plat form.
Raise the plat form only when the EPV16J is on level ground.
Main tain a firm foot ing on the plat form floor. Climbing on the guard rails is pro hib ited.
DO NOT op er ate the EPV16J in winds, or wind gusts, of 28 mph 12.5 m/s) or more.
DO NOT add any thing to the EPV16J that will in ­crease the wind load ing (ban ners, flags, etc.).
Crushing
Al ways look in the di rec tion of travel. Avoid over ­head ob struc tions.
Never cover the floor grat ing or oth er wise ob struct your view be low.
Make sure the area be low the plat form is free of per son nel be fore low er ing.
General Safety Precautions
Personnel Precautions
If you en coun ter any sus pected mal func tion of the ae rial plat form, or any haz ard or po ten tially un safe con di tion re lat ing to ca pac ity, in tended use, or safe op er a tion, cease op er a tion and seek as sis tance from man age ment.
Operator General Precautions
Make sure that all pro tec tive guards, cowl ings, and doors are in place and se cure.
Be sure the guard rail sys tem, in clud ing the gate, is in place and se cure.
Mounting and Dismounting Precautions
Use three points of sup port when get ting on or off the plat form (two hands and one foot or a sim i lar set of points). Keep the plat form clean.
DO NOT jump off the ma chine.
DO NOT dis mount while the boom is in mo tion.
Starting and Stopping Precautions
DO NOT start un til all per son nel are clearly away from the ma chine.
DO NOT use lad ders, planks, or other de vices to ex tend or in crease your work po si tion from the plat ­form.
DO NOT jerk the con trols. Move the con trols slowly and de lib er ately to avoid jerky and er ratic op er a ­tion. Al ways stop the con trols in the neu tral, off, po ­si tion be fore go ing in the op po site di rec tion.
DO NOT use the boom for any pur pose other than to po si tion per son nel, their tools, and ma te ri als.
DO NOT use the EPV16J as a crane, hoist, or jack.
page 1 - 2 EPV16J – 11089A
Be fore leav ing the op er a tor’s sta tion, place the ma ­chine in the stowed po si tion.
When leav ing the ma chine parked or un at tended, re move the starter key from the Mas ter Key
Switch.
Operating Precautions
DO NOT mod ify the EPV16J in any way.
When parts or com po nents are re placed, they shall be iden ti cal or equiv a lent to orig i nal Snor kel parts or com po nents.
Chapter 1. Safety
CAUTION
CAUTION
DO NOT over ride any of the safety fea tures of the EPV16J.
Operator Maintenance Precautions
DO NOT use your hand to search for hydraulic oil leaks. High pressure hydraulic oil can easily cut and penetrate your skin — a very serious injury that requires immediate attention by a medical specialist trained in that type of injury. Use a piece of cardboard or wood to search for hydraulic oil leaks.
DO NOT attempt repairs unless you are trained. Refer to manuals and experienced repair personnel for help.
Fuel Handling Precautions
DO NOT smoke or per mit open flames while fuel ing or near fuel ing op er a tions.
Never re move the fuel cap or re fuel a gas o line en ­gine while the en gine is run ning or hot. Never al low fuel to spill on hot ma chine com po nents.
part. See your Snorkel dealer for new decals and placards.
NOTE
Refer to Placards and Decals Inspection Chart and Drawing in the “Pre-operational Inspection” chapter 7, for part numbers, location, and required quantities of all placards and decals.
Main tain con trol of the fuel filler noz zle when fill ing the tank.
DO NOT fill the fuel tank to ca pac ity. Al low room for ex pan sion.
Clean up spilled fuel im me di ately.
Tighten the fuel tank cap se curely. If the fuel cap is lost, re place it with an ap proved cap from Snor kel. Use of a non-approved cap with out proper vent ing may re sult in pres sur iza tion of the tank.
Never use fuel for clean ing pur poses.
For die sel en gines, use the cor rect fuel grade for the op er at ing sea son.
Safety Decals and Placards
There are sev eral safety de cals and plac ards on the EPV16J. Their lo ca tions and de scrip tions are shown in this sec tion. Take time to study them.
Be sure that all the safety decals and placards on the EPV16J are legible. Clean or replace them if you cannot read the words or see the pictures. Clean with soap & water and a soft cloth. Do not use solvents.
You MUST replace a decal or placard if it is damaged, missing, or cannot be read. If it is on a part that is replaced, make sure a new decal or placard is installed on the replaced
EPV16J – 11089A page 1 - 3
Chapter 1. Safety
EMERGENCY BLEED
DOWN VALVE
0070420
HYDRAULIC OIL
9207
0112471
0112471
Safety Placards and Decals Location
page 1 - 4 EPV16J – 11089A
FIT BOOM CRADLE LOCK PIN
FOR TRAVELLING.
1772-002K
FIT BOOM CRADLE LOCK PIN
FOR TRAVELLING.
1772-002K
OPERATORS CHECKLIST
INSPECT AND/OR TEST THE FOLLOWING DAILY
OR AT THE BEGINNING OF EACH SHIFT
1. OPERATING AND EMERGENCY CONTROLS.
5. CABLES AND WIRING HARNESS.
6. LOOSE OR MISSING PARTS.
7. TYRES AND WHEELS.
8. PLACARDS, WARNINGS, CONTROL MARKINGS AND OPERATING MANUAL(S).
9. GUARDRAIL SYSTEM.
10.OIL LEVELS.
11.BATTERY FLUID LEVEL.
4. HOSES, FITTINGS AND VALVES FOR LEAKS.
3. PERSONAL PROTECTIVE DEVICES.
2. SAFETY DEVICES.
300699
YOU MUST NOT OPERATE THIS DEVICE UNLESS:
AN UNTRAINED OPERATOR SUBJECTS HIMSELF AND OTHERS TO
DEATH OR SERIOUS INJURY.
0323897
1.
2.
YOU HAVE BEEN TRAINED IN THE SAFE OPERATION OF THIS DEVICE AND HHHH
YOU KNOW AND FOLLOW THE SAFETY AND OPERATING RECOMMENDATIONS CONTAINED IN THE MANUFACTURER'S MANUALS, YOUR EMPLOYER'S WORK RULES, AND APPLI­CABLE GOVERNMENTAL REGULATIONS. HHHHHHHH
DANGER
0112471
0112471
Chapter 1. Safety
EPV16J – 11089A page 1 - 5
Chapter 1. Safety
DANGER
ELECTROCUTION
HAZARD
THIS MACHINE IS NOT
ELECTRICALLY INSULATED.
0323899
Death or serious injury can result from contact or inadequate clearance to electrical power lines and apparatus.
Maintain 10 feet minimum clearance from electrical power lines and apparatus.
Allow for sway, rock, and sag.
LOWER BOOM
UPPER
JIB
BOOM
BOOM
SLEW
SPEED CONTROL
11420
LIFT
ENABLE
CHOKE
STABILISER
PLATFORM
BASE
BOOMS
UP
DOWN
STABILIZER SELECTOR
RIGHT
FRONT
LEFT
FRONT
RIGHT BACK
LEFT
BACK
page 1 - 6 EPV16J – 11089A
CAUTION
SAFETY BELTS WITH SHOULDER STRAPS OR SAFETY HARNESS ARE
TO BE USED
9928
SWL
200
KG
2025-200
LOWER BOOM
UPPER
JIB
BOOM
ROTATE
LOWER
BOOM
SPEED CONTROL
SLEW
11420 - 1
LIFT
ENABLE
CHOKE
EMERGENCY
PLATFORM
EMERGENCY LOWER
TO LOWER PLATFORM, OPERATE EMERGENCY
LOWER SWITCH.
1.
2.
TO SLEW BOOM, OPERATE ‘EMERGENCY
LOWER’ & ‘SLEW’ SWITCHES TOGETHER.
WARNING
KEEP LINESCLEAR POWEROF
Unless the Electrical Supply Authority has advised
in writing otherwise;
the clearance between any live overhead
power line and any part of this machine or
load carried is required by law to be
AT LEAST 4 METRES
This is a requirement of regulation 93 of the
Electrical Supply Regulations 1984
in the interests of safe working.
DANGER
BEWARE OF ELECTRICAL HAZARDS
REGULATION 133A OF THE
CONSTRUCTION SAFETY ACT 1912 REQUIRES
(a) Minimum approach of an appliance
(b) Inspection of the work site for
(c) Constant vigilance and an observer required
to live electrical apparatus.
electrical hazards before commencing to use the appliance.
whilst working or travelling the appliance in the vicinity of live electrical apparatus.
3m. for voltages up to 132,000 6m. for voltages above 132,000 and up to 330,000 8m. for voltages above 330,000
(New Zealand Only)
(Australia Only)
Attach lanyard
of fall restraint
to loop below
0150448
Chapter 1. Safety
EPV16J – 11089A page 1 - 7
Chapter 1. Safety
page 1 - 8 EPV16J – 11089A
CAUTION
Safety Device Information
For emer gency op er a tion con trols and pro ce dures, see the “Emer gency Op er a tion” chap ter 9, in this man ual.
The de vices listed in this chap ter are safety de ­vices.
They are on the EPV16J to in crease safety in the work place for both the op er a tor and other peo ple near the EPV16J.
DO NOT by pass, disable, modify, or ignore any of these devices. Check them carefully at the start of each work shift to see that they are in working order (see “Pre-operational Inspection” chapter 7). If any is found to be defective, remove the EPV16J from service immediately until a qualified service technician can make repairs.

Chapter 2. Safety Devices

At platform control box
Emergency Stop Switches
At ground control box
Figure 2.2 - Emergency Stop Switch at
Platform Control Box
Press the EMERGENCY STOP switch cover down, at any time, un der any con di tions and the en tire ma chine stops, and noth ing moves. This emer gency stop switch cover must be up and the switch turned on for any thing on the EPV16J to work.
NOTE:
The ground control box is designed to override the platform control box. If the platform control box EMERGENCY STOP switch is down (off) the ground con trol box can still be used to start and op er ate the EPV16J.
Other Safety Devices
Lanyard anchor points
Figure 2.1 - Emergency Stop Switch at
Ground Control Box
Press the EMERGENCY STOP switch cover down, at any time, un der any con di tions and the en tire ma chine stops, and noth ing moves. This emer gency stop switch cover must be up and the switch turned on for any thing on the EPV16J to work.
Figure 2.3 - Lanyard Anchor Points
EPV16J – 11089A page 2 - 1
Chapter 2. Safety Devices
All personnel on the platform should attach their fall restraint lanyards to one of the lanyard anchor points.
Gravity gate
Figure 2.4 - Gravity Gate
Foot switch
Figure 2.6 - Foot Switch
The foot switch pre vents the plat form from mov ing if some thing ac ci den tally pushes one of the plat ­form-moving con trols on the plat form con trol box. Stepping on the foot switch is an ac tion that must be per formed, at the same time as an other ac tion, to make the plat form move.
Bubble level
The grav ity gate is the place in the plat form guard ­rail sys tem where you should en ter and leave the plat form. Raise the gate and step un der it onto the plat form. Once you have en tered the plat form and at tached your fall re straint lan yard to an an chor point, check to see that the grav ity gate has fallen back into place.
Guardrails
Figure 2.7 - Bubble Level
A bub ble level is lo cated on the side rail, be side the out rig ger con trols. Watch the bub ble level while you set the sta bi lis ers. Lower the sta bi lis ers, one at a time, just enough to cen ter the bub ble in the cir cle on top of the guage. When the bub ble is cen tered the plat form is level and can be safely raised.
Figure 2.5 - Guardrails
The guard rails help pro tect you from fall ing off the plat form. Be sure the guard rails are prop erly in ­stalled and that the grav ity gate or swing ing gate is in place.
page 2 - 2 EPV16J – 11089A
RCD/ELCB AC outlet
RCD
Power Input Connector
Power Outlet
At Platform
Figure 2.8 - RCD/ELCB AC Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at the base and will pro tect against short cir cuits to earth. When there is a short cir cuit the RCD will shut down the 230v AC power to the plat form out ­let.
Chapter 2. Safety Devices
To re set the out let dis con nect the power tool lead from the plat form box and re set the RCD at the base.
If the prob lem per sists call a trained ser vice tech ni ­cian.
Flashing light
Figure 2.9 - Flashing Light
The flashing light alerts people that the EPV16J is moving. The light flashes at about one flash per second any time the MASTER KEY switch is on. There is no ON/OFF switch for the flashing light, it cannot be turned off while the EPV16J is running.
EPV16J – 11089A page 2 - 3
Chapter 2. Safety Devices
page 2 - 4 EPV16J – 11089A

Chapter 3. Specifications

The Snor kel EPV16J is a boom sup ported el e vat ing work plat form built to con form to all ap pli ca ble OSHA, ANSI or CSA stan dards as pre vi ously out lined.
OSHA Para graph 1910.67 Ti tle 29, C.F.R., Ve hi cle-Mounted El e vating and Ro tating Work Plat forms - La ­bour.
OSHA Para graph 1926.556 Ti tle 29, C.F.R., Ae rial Lifts - Con struc tion.
Aus tra lian Stan dard AS1418-10 1996 El e vating Work Plat forms.
NOTE:
For further details regarding lubricants, maintenance schedules and service please refer to the Maintenance and Repair Parts Manual for this machine.
General Specifications
SPECIFICATIONS EPV16J
Nominal working height
Maximum height to basket floor
Maximum outreach
Maximum outreach height
Nominal Maximum width of base
Safe working load (unrestricted)
Standard colour
Platform size
Nominal Travelling height
Nominal Overall length
Turntable rotation
Insulation rating (Optional)
Nominal weight
15.8m 51’ 10”
13.8m 45’ 3”
7.0m 23’
? 6.90m 22’ 6”
2m 6’ 5”
200kg 440lbs
Charcoal base / white booms
1200 x 760 x 1100mm
Aluminum
2.8m 9’ 2”
6.75m 22’ 6”
360o continuous
1700kg 3746lb
4’ x 2’ 6” x 3’ 7”
Aluminum
5KV
Recommended Hydraulic Oil
Shell Tellus 32 or Castrol AWS 32 or similar
EPV16J – 11089A page 3 - 1
Chapter 3. Specifications
2.8m
6.75m
Engine Data
Engine Make Honda (gas o line)
Model GX 160
Engine type 4-stroke, over head valve, 1 cylinder
Displacement 163 cm3 (9.9 cu-in)
Bore x Stroke 68 x 45 mm (2.7 x 1.8 in)
Max. output 4 kW/4,000 rpm
Max. torque 1.1 kg-m (8.0 ft-lb)/ 2500 rpm
Fuel gasoline
Fuel Grade automotive gasoline (unleaded or lowleaded preferred)
Fuel consumption 230 g/PSh
Cooling system Forced air
Ignition system Transistor magneto
PTO shaft
Counterclockwise
rotation
Oil Capacity 0.60 litres (0.60 US qt, 0.53 Imp qt)
Oil Grade SAE 10W-30
Overall Dimensions EPV16J
page 3 - 2 EPV16J – 11089A
Lower
boom
Jib
boom
Upper boom
Outriggers (4)
Outrigger
controls
Column
Ground
controls
Platform
controls
Platform
Nomenclature And Serial Numbers
Right side view of machine
Chapter 3. Specifications
Booms identification
EPV16J – 11089A page 3 - 3
Chapter 3. Specifications
Oil tank
Serial
Number
Outrigger cylinder
Upper
cylinders
Lower cylinder
Jib Cylinder
Left side view of machine
page 3 - 4 EPV16J – 11089A

Chapter 4. Gauges

Hourmeter
Figure 4.1 - Hourmeter
The hour me ter is ba si cally an elec tric clock. It ac ­cu mu lates time when the mas ter key switch is turned on. The hour me ter can not be re set. An EPV qual i fied ser vice tech ni cian can use it to tell when it is time for the pe ri odic main te nance listed in the main te nance man ual.
Level Bubble
Hydraulic Oil Level
Figure 4.3 - Hydraulic Oil Level
The hydraulic oil level gauge is on the side of the hydraulic oil tank. It shows the actual level of oil inside the tank. Read it only when the booms are fully lowered and stabilisers are raised in the travel position. The oil level should be within + or - 6mm (1/4”) of the line.
Figure 4.2 - Level Bubble
A level bub ble is mounted on the base. Watch the bub ble while you set the sta bi lis ers. Lower the sta ­bi lis ers, front ones first, one at a time just enough to cen ter the bub ble in the cir cle on top of the gauge. When the bub ble is cen tral the plat form is level and the plat form can be safely raised.
EPV16J – 11089A page 4 - 1
Chapter 4. Gauges
page 4 - 2 EPV16J – 11089A

Chapter 5. Shut-offs and Circuit Breakers

RCD/ELCB Outlet (option)
Figure 5.1 - RED/ELCB Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at the base and will pro tect against short cir cuits to earth. When there is a short cir cuit the RCD will shut down the 230v AC power to the plat form out ­let.
To re set the out let dis con nect the power tool lead from the plat form box and re set the RCD at the base.
If the prob lem per sists call a trained ser vice tech ni ­cian.
Main Circuit Breaker
Stabilisers
Figure 5.3 - Stabilisers
The EPV16J booms can not be raised un less the sta bi lis ers are set and the lift en able light on the lower con trol box is lit. Once the booms are raised from the stowed po si tion the sta bi lis ers be come dis ­abled un til the booms are stowed in the travel po si ­tion.
Figure 5.2 - Main Circuit Breaker
There is only one cir cuit breaker, on a stan dard EPV16J, that is ac ces si ble to the op er a tor. Its pur ­pose is to pro tect the elec tri cal cir cuits from elec tri ­cal over loads. When the cir cuit breaker trips (pops out) push it back in then at tempt to use the EPV16J. If the cir cuit breaker trips a sec ond time, take the EPV16J out of ser vice and re fer the prob lem to a qual i fied trained ser vice tech ni cian for re pair.
EPV16J – 11089A page 5 - 1
Chapter 5. Shut-offs and Circuit Breakers
page 5 - 2 EPV16J – 11089A
LOWER
BOOM
UPPER
JIB
BOOM
BOOM
SLEW
SPEED CONTROL
11420
LIFT
ENABLE
CHOKE
STABILISER
PLATFORM
BASE
BOOMS
LOWER BOOM
UPPER
JIB
BOOM
ROTATE
LOWER
BOOM
SPEED CONTROL
SLEW
11420 - 1
LIFT
ENABLE
CHOKE
EMERGENCY
PLATFORM
EMERGENCY LOWER
TO LOWER PLATFORM, OPERATE EMERGENCY
LOWER SWITCH.
1.
2.
TO SLEW BOOM, OPERATE ‘EMERGENCY
LOWER’ & ‘SLEW’ SWITCHES TOGETHER.
Platform Controls
Ground Controls
Controls Description
This chap ter ex plains what each con trol does.
This chapter DOES NOT explain how to use the controls to produce useful work, re fer to the “Op er ­a tion” chap ter 8-1 for that af ter you have read this chap ter.
For op tional equip ment con trols, see the “Op tions” chap ter.11-1
See the “Emer gency Op er a tion” chap ter 9-1 for the lo ca tion of the emer gency bleed down con trol and for cor rect emer gency bleed down pro ce dures.
Controls and Control Decals Locations

Chapter 6. Controls

The main op er at ing func tions of an EPV16J can be con trolled from the ground con trol box or from the plat form con trol box.
EPV16J – 11089A page 6 - 1
Chapter 6. Controls
Ground Control Box
Con trols for op er at ing the EPV16J from the ground, are lo cated on the right side of the turn ta ­ble.
NOTE
The number of each control below corresponds to the control’s call out on the control box illustration.
1.
Emergency Stop: Press the EMERGENCY STOP switch cover down, at any time, under any conditions, and the entire machine stops, and nothing moves. This emergency stop switch cover must be up and the switch turned on for anything on the EPV16J to work.
2.
Platform/Ground Selector : Must be in the GROUND position (down) for the ground control box to work. The switch MUST be in the PLATFORM position (up) for the platform control box to work.
3.
Choke/Cold Start: Hold the switch UP while you start an engine that is at ambient air temperature (a "cold" engine). This will choke the engine.
NOTE
(See “Nomenclature and Serial Numbers” in the “Specifications” chapter 3, for boom identification.)
7.
Lower Boom : UP raises the lower boom. DOWN lowers the lower boom.
8.
Upper Boom: UP raises the upper boom. DOWN lowers the upper boom.
9.
Jib Boom: UP raises the jib boom. DOWN lowers the jib boom.
10.
Slew: LEFT rotates the entire turntable and boom to the left. RIGHT rotates the entire turntable and boom to the right.
11.
Lift Enable: The platform can only be raised when this light is lit. When this light is not lit the platform will not raise because the stabilisers are not properly set.
4.
Master Key Switch: This switch works like an automobile ignition switch. Hold it at START until the engine starts, then release it to ON. (-) Turn the Master Key Switch to OFF (O) if the platform is to stay in one position for a long time, that will turn the engine off and save fuel.
5.
Boom Speed: This control determines how fast the booms move. Set it to SLOW (turtle) until you are very familiar with the way the machine works or if the platform is working in dangerous or cramped surroundings.
6.
Stabliser / Boom Selector Switch: Must be in Stabliser (stabiliser) position (down) for the stabilisers to work. Once stabilisers are down and set the switch must be placed in the boom (up) position for the booms to work.
Con trol switches 7 through 10 are the plat form mov ing switches. Each is a three po si tion, mo men ­tary con tact, nor mally OFF switch.
page 6 - 2 EPV16J – 11089A
Ground Control Box Controls
LOWER
UPPER
JIB
BOOM
BOOM
SLEW
SPEED CONTROL
11420
LIFT
ENABLE
CHOKE
STABILISER
PLATFORM
BASE
BOOMS
BOOM
1
7
8
9
6
2
3
5
10 11
4
Chapter 6. Controls
EPV16J – 11089A page 6 - 3
Chapter 6. Controls
Platform Control Box
Con trols for op er at ing the EPV16J from the plat ­form are lo cated on the plat form con trol box, with the ex cep tion of the foot switch which is on the plat ­form floor.
NOTE
The number of each control below corresponds to the control’s call out on the control box illustration.
1.
Emergency Stop: Press the EMERGENCY STOP switch cover down, at any time, under any conditions, and the entire machine stops, and nothing moves. This emergency stop switch cover must be up and the switch turned on for anything on the EPV16J to work.
2.
Choke/Cold Start: Hold the switch UP while you start an engine that is at ambient air temperature (a "cold" engine). This will choke the engine.
7.
Lower Boom: UP raises the lower boom. DOWN lowers the lower boom.
8.
Upper Boom: UP raises the upper boom. DOWN lowers the upper boom.
9.
Jib Boom: UP raises the jib boom. DOWN lowers the jib boom.
10.
Slew: LEFT rotates the entire turntable and boom to the left. RIGHT rotates the entire turntable and boom to the right.
11
Lift Enable: The platform can only be raised when this light is lit. When this light is not lit the platform will not raise because the stabilisers are not properly set.
12.
Foot Switch: You must step down on the foot switch, and hold it down when you use any platform control that causes the platform to move.
3.
Anti-Restart: This switch works like an automobile ignition switch. Hold it at START until the engine starts, then release it to ON (-). If the engine dies in ON, the key must be turned to OFF (O) before it will go back to START. Turn the switch to OFF if the platform is to stay in one position for a long time, that will turn the engine off and save fuel.
4.
Boom Speed: This control determines how fast the booms move. Set it to SLOW (turtle) until you are very familiar with the way the machine works or if the platform is working in dangerous or cramped surroundings.
5.
Emergency Lower: If the engine stops and cannot be restarted, hold the switch down and this will lower the upper and lower booms (not the jib boom). To slew during emergency lower operate emergency lower and slew switches together.
Items 6 through 10 are the plat form mov ing switches. Each is a three po si tion, mo men tary con ­tact, nor mally OFF switch.
NOTE
(See “Nomenclature and Serial Numbers” in the “Specifications” chapter 3, for boom identification.)
6.
Platform Rotate: (Option) LEFT rotates the platform left. RIGHT rotates the platform right.
page 6 - 4 EPV16J – 11089A
LOWER BOOM
UPPER
JIB
BOOM
ROTATE
LOWER
BOOM
SPEED CONTROL
SLEW
11420 - 1
LIFT
ENABLE
CHOKE
EMERGENCY
PLATFORM
EMERGENCY LOWER
TO LOWER PLATFORM, OPERATE EMERGENCY
LOWER SWITCH.
1.
2.
TO SLEW BOOM, OPERATE ‘EMERGENCY
LOWER’ & ‘SLEW’ SWITCHES TOGETHER.
1
7
8
9
6
2
3
5
10
11
4
12
Platform Control Box Controls
Chapter 6. Controls
EPV16J – 11089A page 6 - 5
Chapter 6. Controls
page 6 - 6 EPV16J – 11089A

Chapter 7. Pre-operational Inspection

DANGER
At the start of each work day (or 8 hour shift), an EPV16J qual i fied op er a tor must per form the Pre-op er a tional In spec tion as listed in the ta ble be ­low.
The pur pose of the Pre-op er a tional In spec tion is to keep the EPV16J in proper work ing con di tion and to de tect signs of mal func tion at the ear li est pos si ­ble time.
The EPV16J should be in the STOWED POSITION and the Mas ter Key Switch set to OFF be fore you be gin this in spec tion.
Pre-operational Inspection Table
Item Service Required
Engine fuel level Look to see that the fuel tank is full Fuel tank cap Check to see that the cap is tight Engine oil level Check oil level (between dipstick lines) Fuel leaks Visually inspect (hoses and connections) Engine coolant Check that grills are not blocked Wiring harnesses Visually inspect (installation, condition) Battery terminals Visually inspect (no corrosion) Battery fluid level Check fluid level (1/4" or 6 mm below filler neck) Hydraulic oil level Visually inspect level (between lines on gauge) Hydraulic oil leaks Visually inspect (hoses, tubes) Bolts and fasteners Visually inspect (condition) Structural damage and welds Visually inspect (weld cracks, dents) Lanyard anchor points Visually inspect (condition) Platform gravity gate Check condition and operation Platform guardrails Visually inspect (condition) Flashing light (option) Visually inspect (operation) Ground control switches Actuate and inspect for proper operation Emergency lower Check operation (causes correct motion) Platform control box switches Actuate and inspect for proper operation RCD/ELCB AC outlet (option) Check operation Platform work lights (option) Check operation Placards and decals Visually inspect (installation, condition)
De fec tive parts and/or equip ment mal func tions jeop ar dize the safety of the op er a tor and other per ­son nel, and can cause dam age to the ma chine.
DO NOT operate an EPV16J that is known to be damaged or malfunctioning.
Repair all equipment damage or malfunctions, before placing the EPV16J into service.
EPV16J – 11089A page 7 - 1
Chapter 7. Pre-operational Inspection
COMBINED OIL FILLER
CAP AND DIPSTICK
OIL LEVEL FILLED TO TOP OF FILLER NECK
OIL LEVEL
The rest of this chap ter shows how to per form the in ­spec tion and main te nance re quired for each item in the Pre-op er a tional In spec tion Ta ble.
Engine Cover
Figure 7.1 - Engine Cover
The en gine is ac cessed by rais ing the en gine cover.
Engine Fuel Level
Check to see that the tank cap is in place and is tight.
Fuel Leaks
Visually inspect the Honda fuel tank and the entire length of the fuel line, from the engine to the fuel tank, for leaks.
Engine Oil Level
Figure 7.4 - Engine Oil Level
Re move the oil filler cap and wipe the dip stick clean. In sert the dip stick into the oil filler neck, but do not screw it in.
If the level is low, fill to the top of the oil filler neck with the rec om mended oil.
Figure 7.2 - Engine Fuel Level
Vi sually check to see that the gas o line tank is full. See the “Spec i fi ca tions” chap ter 3, fuel for oc tane and grade.
Fuel Tank Cap
See the “Spec i fi ca tions” chap ter 3, for the cor rect en gine oil grade and weight.
Wiring Harnesses
Figure 7.5 - Wiring Harnesses
In spect all the wir ing har nesses, on the ma chine, for loose con nec tions, bro ken wires, and frayed in ­su la tion.
Figure 7.3 - Fuel Tank Cap
page 7 - 2 EPV16J – 11089A
DANGER
DANGER
Battery Terminals
Chapter 7. Pre-operational Inspection
Figure 7.6 - Battery Terminals
Bat tery ter mi nals should be tight, clean and free of dirt and cor ro sion.
Battery Fluid Level
Batteries emit hydrogen and oxygen, elements that can combine explosively.
DO NOT smoke or permit open flames or sparks when checking batteries.
Figure 7.8 - Hydraulic Oil Level
The hy drau lic oil level should be be tween the two marks on the dipstick.
If nec es sary, add hy drau lic oil at the filler cap. See the “Spec i fi ca tions” chap ter 3, for type and grade of hy drau lic oil.
Hydraulic Oil Leaks
Leaking hydraulic oil can cause burns, fires, falls (slipping), cuts, and puncture wounds (if under high pressure).Do not search for leaks with your hand. Have a qualified trained maintenance person repair all hydraulic fluid leaks before you operate an EPV16J.
Figure 7.7 - Battery Fluid Level
Re move the caps from the bat tery and vi su ally check to see that the bat tery fluid is 1/4” (6 mm) be ­low the bot tom of the filler neck in side each hole.
Hydraulic Oil Level
To check the hy drau lic oil level:
Com pletely lower the booms and en sure the sta bi ­lis ers are in the stowed po si tion.
EPV16J – 11089A page 7 - 3
Hy drau lic oil leaks are eas ily vis i ble and can show up any place.
Vi sually in spect the en tire ma chine for hy drau lic oil. Check the ground un der the ma chine for leaked oil.
Care fully in spect the ends of the up per and lower booms. Oil can run down in side of the booms and drip out the end.
Figure 7.9 - Hydraulic Oil Leaks
Chapter 7. Pre-operational Inspection
Bolts and Fasteners
Vi sually in spect all fas ten ers to see that none is miss ing or ob vi ously loose.
Figure 7.10 - Critical Pin Retainer Bolts
Crit i cal pin re tainer bolts have lock tab wash ers fit ­ted, they should all be pres ent and not dam aged in any way.
Structural Damage and Welds
Vi sually in spect all welds for cracks, all struc tural mem bers for de for mity.
Lanyard Anchor Points
Figure 7.16 - Lanyard Anchor Points
Vi sually check the lan yard an chor points to see that they are not de formed or cut off.
Platform Gravity Gate
Figure 7.14 - Chassis Welds
Pay par tic u lar at ten tion to the chas sis welds
Check to see that the grav ity gate is pres ent and func tions cor rectly.
Figures 7.15 - Boom Welds
Closely in spect boom welds all the way around, for cracks.
page 7 - 4 EPV16J – 11089A
Figure 7.17 - Platform Gravity Gate
Platform Guardrails
Figure 7.18 - Platform Guardrails
Chapter 7. Pre-operational Inspection
Vi sually in spect the plat form guard rails to see that none of the tub ing has been cut out, re moved, or de formed in any way.
Vi sually check the guard rail welds to see that none is cracked nor ground down.
Flashing Light (option)
Figure 7.19 - Flashing Light
Vi sually check the op tional flash ing light, to see that the light flashes at ap prox i mately one flash per sec ond when the mo tor key switch is turned on.
For cor rect op er at ing pro ce dures see the “Op er a ­tion” chap ter 8.
NOTE
Pay particular attention to the Emergency Stop switch to see that it turns the EPV16J engine off when the red cover is struck.
Emergency Lower
Lower control box
Figure 7.21 - Emergency Lower Valve
Ground Control Switches
Figure 7.20 - Ground Control Switches
With the Ground/Platform Selector set to ground: Check that each of the platform moving switches ( through to ) cause the EPV16J to move the way it should.
Check both po si tions of each switch.
With the booms raised open the Emergency Lower Valve on the top of the manifold valve.
The booms should be gin to lower. The rate of low ­er ing can be reg u lated by the amount the valve is opened.
To check the slew func tion when us ing the man ual emer gency lower valve the Mas ter Key Switch and Emer gency Stop switch must be on and the Plat form/ground Se lec tor must be set to ground.
To slew (with the man ual emer gency lower valve al ready open) se lect the re quired di rec tion on the slew tog gle switch .
NOTE
The manual emergency lower valve must be closed after the test to ensure proper boom operation.
For cor rect emer gency low er ing op er at ing pro ce ­dures see “Emer gency Op er a tion” chap ter 9.
Upper control box
Emer gency lower from the up per con trol box is achieved by turn ing the up per con trol to on and de ­press ing the foot switch whilst op er at ing the Emer - gency Lower switch
To slew the unit se lect the di rec tion re quired on the slew tog gle switch at the same time. For cor rect emer gency low er ing op er at ing pro ce dures see “Emer gency Op er a tion” chap ter 9.
EPV16J – 11089A page 7 - 5
Chapter 7. Pre-operational Inspection
CAUTION
Platform Control Switches
Figure 7.22 - Platform Control Switches
On the ground con trol box set the Ground/Plat ­form Se lec tor to plat form.
Check that each of the platform moving switches ( through to ) cause the platform to move the way it should.
Check both po si tions of each switch.
For cor rect op er at ing pro ce dures see the ”Op er a ­tion” chap ter 8.
NOTE
Pay particular attention to the Emergency Stop switch to see that it turns the EPV16J engine off when struck.
Pay particular attention to the platform foot switch to see that it deactivates the platform moving switches when the foot switch is not stepped on.
AC Outlet RCD/ELCB (option)
If the EPV16J has this op tion fit ted check the RCD works by con nect ing a power source to the base in ­let and an ap pli ance to the plat form out let.
Push the test but ton on the RCD/ELCB de vice and the power out let at the plat form should not work.
RCD/ELCB devices should only be replaced by a qualified electrician.
Placards and Decals
Look to see that all plac ards and de cals are in place and leg i ble. Re place any miss ing or il leg i ble plac ­ards or de cals be fore plac ing the EPV16J into ser ­vice for the daily work shift.
De cal and plac ard kits for the EPV16J are avail able from Snor kel deal ers.
Standard placards and decals
See page 7 - 7 for the fol low ing items.
No Part No Description Req
0112471 Decal - Snorkel
1
9207 Decal - Hydraulic oil
2
0070420 Decal - Emergency lower
3
11226-25 Decal - EPV16J
4
007-1925 Decal - Gasoline
5
300699 Decal - Operator checklist
6
0323897 Decal - Danger
7
11420 Decal - Lower control box
8
0323899 Decal - Electrocution hazard
9
112249 Decal - Stabiliser control
10
11420-1 Decal - Upper controls
11
2025-200 Decal - Safe working load
12
2
1
2
2
1
1
1
1
1
1
1
1
99228 Decal - Caution
13
1772-002K Decal - Boom lock pin
14
9428 Decal - Danger (Australia Only)
15
1843 Decal - Warning (NZ Only)
0150448 Decal - Harness point
16
1
2
1
1
1
Figure 7.23 - AC Outlet RCD/ELCB
page 7 - 6 EPV16J – 11089A
13
1
1
10
15
11
6
4
12
4
2
9, 8, 7
11
14
3
16
Inspection drawing
Chapter 7. Pre-operational Inspection
EPV16J – 11089A page 7 - 7
CAUTION
DANGER
Operating Procedures
This chap ter ex plains how to prop erly start and op ­er ate an EPV16J. Read and un der stand all the pre ­vi ous chap ters in this man ual be fore you be gin to op er ate an EPV16J.
If you use the EPV16J for painting be sure the optional sandblast protection kit is installed to protect the hydraulic cylinder rods from paint. Do not leave the EPV16J engine running if you are sandblasting. Sand drawn into the air intake can erode engine parts.
Control Stations
An EPV16J can be op er ated from the ground con ­trol box or from the plat form con trol box. There are ba si cally two dif fer ences be tween ground con trol and plat form con trol op er a tions, both are safety re ­lated:
1. The ground control box can override the platform control box at any time. If a person operating the machine from the platform becomes incapacitated, a person on the ground can always take over machine control.

Chapter 8. Operation

Figure 8.1 - Ground Con trol Box Emer gency
Stop Switch Lo ca tion.
2. The stabilisers can only be selected from the ground control box and only when the booms are in the stowed position.
The EPV16J is not Electrically Insulated.
Death or Serious Injury to operating personnel, can occur if the machine should come into contact with energized electrical wires during operation.
DO NOT attempt to operate the EPV16J ground controls if the platform, booms, or any other conducting part of an EPV16J is in contact with energized electrical wires or if there is an immediate danger of such contact.
NOTE
See the "Electrical Hazard" section, in this manual for a complete explanation of the hazards concerning electricity.
Emergency Stopping
To stop an EPV16J, press the Emer gency Stop switch cover down on ei ther of the two EMERGENCY STOP switches at the ground con ­trol box or at the plat form con trol box.
Figure 8.2 - Platform Control Box Emergency
Stop Switch Location.
NOTE
For a complete discussion of the Emergency Stop switches, see “Controls” chapter 6, in this
manual.
Operation Considerations
To use this chapter, first decide whether you will be starting and operating the EPV16J from the ground control box or the platform control box.
EPV16J – 11089A page 8 - 1
Chapter 8. Operation
CAUTION
CAUTION
Be gin at the sec tion en ti tled "Starting From Ground Con trol Box", if you in tend to start and run the EPV16J from the ground sta tion.
Be gin at the sec tion en ti tled "Starting From Plat ­form Con trol Box", if you in tend to start and run the EPV16J from the plat form.
Starting From Ground Control Box
Be fore you be gin to op er ate the EPV16J from the ground con trol box, a qual i fied op er a tor must per ­form the "Pre-op er a tional In spec tion" as de scribed in chap ter 7, of this man ual.
To start the en gine from the ground con trol box do the fol low ing:
If the engine does not start in 6 seconds turn the key off and release the choke. Wait 60 seconds before trying to restart the engine again. Continual cranking of the starter motor will only result in its damage.
The en gine should now be run ning, and the EPV16J is ready to be gin work.
Stabiliser Operation
Setting the stabilisers
The booms must be in the stowed po si tion.
1.
Set the Emergency Stop switch to ON (see Figure 8.3).
Figure 8.3
Figure 8.3 - Ground Control Box Starting
En sure the Boom/Stabiliser Switch (item on the ground con trol box) (see Fig ure 8.3) is set to sta bi ­lizer.
Lower the stabilisers by push ing the in di vid ual valve le vers down (see Fig ure 8.4)
Figure 8.4
Lower the stabilisers and level the ma chine us ing the level bub ble (see Fig ure 8.5) ad ja cent to the con trol le vers.
2.
Set the Platform/Ground Selector switch to GROUND (see Figure 8.3).
3.
Insert the key (see Figure 8.3) into the Master Key Switch and turn the key on.
4. If the engine is at ambient temperature (cold), hold the Choke / Cold Start Switch (see Figure 8.3) up throughout the next step.
5.
Turn the key to Start and hold it there un til the en gine starts or for a max i mum time of 6 sec onds. When the en gine starts re lease the key and the choke switch , if you used it (see Figure 8.3).
page 8 - 2 EPV16J – 11089A
Figure 8.5
Chapter 8. Operation
Ensure all four foot plates are in full contact with the ground and that they are clear of manhole covers, drains and unstable ground etc.
Raising the stabilisers
Raising the sta bi lis ers is the re verse of set ting the sta bi lis ers.
The booms must be in the stowed po si tion.
En sure that the Boom/Sta bi liser Switch is is set to sta bi liser.
Raise the stabilisers by push ing the in di vid ual valve le vers up (see Fig ure 8.4).
Starting From Platform Control Box
Be fore you be gin to op er ate the EPV16J from the plat form con trol box, a qual i fied op er a tor must per ­form the "Pre-op er a tional In spec tion" as de scribed in chap ter 7, of this man ual.
To start the en gine from the plat form con trol box you must first set some switches on the ground con trol box, in clud ing set ting the sta bi lis ers and lev el ing the ma chine. (See page 8-2 for in for ma tion on set ting the sta bi ­lis ers)
1.
Insert the key into the Master Key Switch at the ground control box and turn the key on (see Figure 8.8).
Figure 8.8
2.
Set the Platform/Ground Selector (see Figure 8.8) at the ground control box to PLATFORM.
Figure 8.9
EPV16J – 11089A page 8 - 3
Chapter 8. Operation
CAUTION
DANGER
3.
Enter the platform, close the gravity gate , and attach the lanyard of your fall restraint (safety harness) to one of the anchor points (see Figure 8.9).
Figure 8.10
Moving The Platform
The engine should already be running (as described earlier in this chapter), before you start this section.
DO NOT operate near energized electrical conductors. Maintain the (M.S.A.D.), Minimum Safe Approach Distance to energized power lines. See the "Electrical Hazard" section, in this manual for a complete explanation of the hazards concerning electricity. Maintain the clearances shown on the decal attached to the platform.
Be certain that the space into which you are about to move the platform, boom, turntable, and/or chassis is free of obstructions. ALWAYS look in the direction of movement.
When you operate from the platform control box, be sure that the lanyard of your fall restraint is attached to an anchor point on the platform mount. Also, be sure that platform gate is closed behind you.
4.
Set the Emergency Stop switch to (ON) (see Figure 8.10).
5.
Turn the Anti-Restart switch to ON (see Figure 8.10).
6. If the engine is at ambient temperature (cold), hold the Choke Switch (see Figure 8.10) up throughout the next step.
7.
Turn the Anti-Restart switch to START and hold it there until the engine starts or for a maximum time of 6 seconds. When the engine starts, release the key (6) and the choke switch , if you used it (see Figure
8.10).
If the engine does not start in 6 seconds, turn the Anti-Restart switch OFF.and release the choke. Wait 60 seconds before trying to restart the engine again. Continual cranking of the starter motor will only result in its damage.
The en gine should now be run ning, and the EPV16J is ready to be gin work.
From Ground Control Box
Each of the ways the plat form can move is shown in the fol low ing pho to graph and switch il lus tra tion:
The pho to graph shows the plat form switches that cause the plat form or booms to move.
These plat form mov ing switches, ( through ), will pro duce the move ment as in di cated by the il ­lus tra tion's in Fig ure 8.12.
Figure 8.11 - Movement Control, Ground
Control Box
page 8 - 4 EPV16J – 11089A
JIB
BOOM
SLEW
3. Jib Boom
4. Slew
UP
LEFT
UPPER
BOOM
2. Upper Boom
UP
DOWN
DOWN
RIGHT
1. Lower Boom
LOWER
UP
DOWN
BOOM
Chapter 8. Operation
From Platform Control Box
When you op er ate from the plat form con trol box, be sure that the lan yard of your fall re straint is at ­tached to an an chor point on the plat form mount. Also, be sure the grav ity gate is closed. Each of the ways the plat form can move is shown in the fol low ­ing pho to graph and switch il lus tra tion:
The pho to graph shows the plat form switches that cause the plat form or booms to move.
These plat form mov ing switches, ( through ), will pro duce the move ment as in di cated by the il ­lus tra tion's in Fig ure 8.15.
Figure 8.13 - Movement Control, Platform
Control Box
You must be step ping on the plat form foot switch when you use any of the plat form mov ing switches ( through ) The plat form foot switch is a safety fea ture to pre vent the plat form from mov ­ing if a plat form mov ing switch, or con trol ler, is ac ci ­den tally pushed.
Figure 8.12 - Ground Control Box Operation Platform Moving Switch Illustration
Figure 8.14 - Platform Foot Switch
EPV16J – 11089A page 8 - 5
Chapter 8. Operation
JIB
BOOM
3. Jib Boom
5. Platform Rotation
UP
UPPER
BOOM
2. Upper Boom
UP
DOWN
DOWN
SLEW
4. Slew
LEFT
RIGHT
ROTATE
PLATFORM
LEFT
RIGHT
1. Lower Boom
LOWER
UP
DOWN
BOOM
Figure 8.15 - Platform Control Box Operation
Platform Moving Switch Illustration
Securing for Day
At the end of each work day the EPV16J should be re turned to the STOWED POSITION and locked as de scribed un der “Stowing” in the "Stowing and Trans porting" chap ter 10.
page 8 - 6 EPV16J – 11089A
Emergency Operation Procedures
The fol low ing pro ce dures are emer gency pro ce ­dures only. DO NOT use them for nor mal op er a ­tion. Their pur pose is to get the plat form and op er a tor safely to ground when the EPV16J will not start or some other prob lem keeps the plat form from low er ing in the nor mal way.
Operation From Platform Control Box
Switch set tings listed in the three steps be low must ex ist at the ground be fore emer gency op er a tion pro ce dures will work at the plat form con trol box:

Chapter 9. Emergency Operation

5.
Set the Anti-Restart switch (see Figure
9.2) to ON.
Figure 9.3
6.
Step on the platform foot switch (see Figure 9.3).
Figure 9.1
1.
The Master Key Switch must be ON (see Figure 9.1).
2.
The Emergency Stop switch must be (ON) (see Figure 9.1).
3.
The Platform/Ground Selector switch (see Figure 9.1) must be set to PLATFORM.
Figure 9.4
7.
Hold the Emergency Lower switch (see Figure 9.4) down and the platform will begin lowering.
NOTE
To slew when using emergency lowering operate the slew switch in the direction required (see Figure 9.4).
Figure 9.2
4.
Set the Emergency Stop switch to ON (see Figure 9.2).
EPV16J – 11089A page 9 - 1
Chapter 9. Emergency Operation
Operation From Ground Control Box
Figure 9.5 - Manual Lower Valve
1. Open man ual valve to lower plat form
NOTE
To operate the slew function from the ground control box when using the emergency lowering valve the Master Key Switch, and Emergency
Stop switch must be on and the Platform/Ground Selector must be set to
ground. The slew direction can then be selected using the slew switch (see Figure 9.1). The slew function will only operate while the booms are lowering.
page 9 - 2 EPV16J – 11089A

Chapter 10. Stowing and Transporting

Stowing
At the end of each work day (or in prep a ra tion for lift ing or stor age) a qual i fied op er a tor should put the EPV16J into its stowed po si tion then lock by plac ing the two boom lock pins in po si tion.
To bring the EPV16J into the STOWED POSITION use the con trols on the ground con trol box or plat ­form con trol box to:
1. Fully lower all booms.
2. Align the lower boom travel lock with the boom rest mounted to the base.
3. Place both boom restraints and keepers in place.
Upper boom latch
4.
Switch the Ground / Platform selector to ground.
5.
Set the Booms / Stabiliser selector to stabiliser.
6. Using the stabiliser controls raise the stabilisers (rear first to avoid damage to the jockey wheel)
7.
Set the Master Key switch on the ground control box to off and remove the key.
Figure 10.2 - Upper Boom Latch
Lower boom lock pin
Figure 10.3 - Lower Boom Lock Pin
If using the upper controls go now to the ground controls and:
EPV16J – 11089A page 10 - 1
CAUTION
Air Line To Platform
This con sists of *” pres sure flex yel low hose rated at 150 psi work ing pres sure, fit ted with quick dis ­con nect cou plers at each end .
Dual Fuel
This op tion con sists of an AC mo tor rated at ei ther 110 or 230 volts AC 50/60Hz. A se lec tor switch is used to change from gas o line to elec tric. The same con trols are used to stop and start the elec tric mo tor.
This op tion is used in shop ping malls and other built up ar eas.
Work Lights
Rub ber en cased work lights can be fit ted to the plat form guard rails. The lights are swivel mounted and each has its own switch.

Chapter 11. Options

Flashing Light
For this option see Chapter 2 page 3
RCD/ELCB AC Outlet
A 3 core wire rated at 600 volts AC 15 amps is run up the booms as stan dard.
For this option see Chapter 2 Page 3.
Sandblast Protection Kit
This op tion con sists of a bel lows type cover fit ted to each boom cyl in der shaft.
The bel lows pre vent sand and paint from dam ag ing the cyl in der rods and seals, and thus pre vent hy ­drau lic oil leaks.
DO NOT paint or sandblast from an EPV16J unless the cylinder rods are protected by bellows.
Platform Rotator
This op tion al lows the op er a tor to move the plat ­form around the boom, 45o each side of cen ter, to gain better ac cess to work sites.
5Kv Insulation
This is a fibre glass skin coat ing all booms and a se ­ries of guards that pre vent di rect con tact with power lines.
EPV16J – 11089A page 11 - 1
Chapter 11. Options
page 11 - 2 EPV16J – 11089A

Chapter 12. Fire Fighting & Chemical Control

DANGER
DANGER
DANGER
Hazardous Components
Snor kel prod ucts may con tain ma te ri als and ob ­jects that po ten tially could be come sig nif i cant fire or en vi ron men tal haz ards dur ing the life time of the ma chine.
1. Antifreeze (ethylene glycol)
2. Battery, lead/acid
3. Diesel fuel
Special fire fighting procedures:
Use pos i tive pres sure, self con tained breath ing ap ­pa ra tus.
Unusual fire and explosion hazards:
Hy dro gen and ox y gen gases are pro duced in the cells dur ing nor mal bat tery op er a tion.
4. Foam in tires
5. Gasoline
6. Hydraulic oil
7. Liquefied petroleum gas
8. Motor oil
The rest of this chap ter lists man u fac tur ers’ in for ­ma tion you will need if you ever have to con trol any of the above items dur ing an up set or emer gency.
Antifreeze (UN 1993)
Fire extinguishing media:
Dry Chem i cal, foam, or CO2.
Special fire fighting procedures:
Wa ter spray may be in ef fec tive on fire but can pro ­tect fire fight ers and cool closed con tain ers. Use fog noz zles if wa ter is used.
DO NOT enter confined fire space without full bunker gear. (Helmet with face shield, bunker coats, gloves & rubber boots). Use a NIOSH approved positive pressure self contained breathing apparatus. Keep container tightly closed. Isolate from oxidizers, heat and open flame.
Hydrogen gas is flammable and oxygen supports combustion. These gases enter the air through the vent caps. To avoid the chance of a fire or explosion, keep sparks and other sources of ignition away from the battery.
Spill or leak:
Re move com bus ti ble ma te ri als and all sources of ig ni tion. Con tain spill by diking with soda ash (so ­dium car bon ate) or quick lime (cal cium ox ide). Cover spill with ei ther chem i cal. Mix well. Make cer tain mix ture is neu tral then col lect res i due and place in a drum or other suit able con tainer. Dis ­pose of as haz ard ous waste.
ALWAYS wear acid resistant boots, face shield, chemical splash goggles, and acid resistant gloves when handling acid spills or leaks.
NOTE
DO NOT release UN-neutralized acid!
Waste disposal method:
Sul fu ric Acid: Neu tral ize as above for a spill, col -
lect res i due, and place in a drum or suit able con ­tainer. Dis pose of as haz ard ous waste.
Spill or leak:
Small - mop up with ab sor bent ma te rial and trans ­fer to hood.
Waste disposal method:
Small - evap o rate un til all va pors are gone. Dis ­pose of re main der by le gally ap pli ca ble meth ods.
Battery, Lead/Acid (UN 2794)
Extinguishing media:
Dry chem i cal, foam, or CO2.
EPV16J – 11089A page 12 - 1
NOTE
DO NOT flush lead contaminated acid to sewer.
Waste disposal method
Bat teries: Send to lead smelter for rec la ma tion fol -
low ing ap pli ca ble fed eral, state, and lo cal reg u la ­tions.
Diesel Fuel (NA 1993)
Extinguishing media:
Use wa ter spray, dry chem i cal, foam, or CO2.
Chapter 12. Fire Fighting & Chemical Control
DANGER
DANGER
DANGER
Special fire fighting procedures:
Use wa ter to keep fire ex posed con tain ers cool. If leak or spill has not ig nited, use wa ter spray to dis ­perse the va pors and to pro vide pro tec tion for per ­son nel at tempt ing to stop a leak. Wa ter spray may be used to flush spills away from ex po sures.
Unusual fire and explosion hazards:
Prod ucts of com bus tion may con tain car bon mon ­ox ide, car bon di ox ide, and other toxic ma te ri als.
DO NOT enter enclosed or confined space without proper protective equipment including respiratory protection.
Burning produces intense heat, dense smoke, and toxic gases, such as carbon monoxide, oxides of nitrogen, and traces of hydrogen cyanide.
Spill or leak:
Pick up and han dle as any other in ert solid ma te ­rial.
Waste disposal method:
Not con sid ered a haz ard ous ma te rial. Dis pose of ma te rial ac cord ing to any lo cal, state, and fed eral reg u la tions.
Spill or leak:
Con tain spill im me di ately in small est area pos si ble. Re cover as much of the prod uct it self as pos si ble by such meth ods as vac u um ing, fol lowed by soak ­ing up of re sid ual flu ids by use of ab sor bent ma te ri ­als.
Re move con tam i nated items in clud ing con tam i ­nated soil and place in proper con tain ers for dis ­posal. Avoid wash ing, drain ing, or di rect ing ma te rial to storm or san i tary sew ers .
Waste disposal method:
Re cy cle as much of the re cov er able prod uct as pos si ble.
Dis pose of non-recyclable ma te rial as a RCRA haz ard ous waste by such meth ods as in cin er a tion, com ply ing with fed eral, state, and lo cal reg u la ­tions.
Foam In Tires
Extinguishing media:
Wa ter, dry chem i cal, foam, or CO2.
Gasoline (UN 1203)
Extinguishing media:
Dry chem i cal, foam, or CO2.
Special fire fighting procedures:
Wa ter may be in ef fec tive to ex tin guish, but wa ter should be used to keep fire ex posed con tain ers cool. If a leak or spill has not ig nited, use wa ter spray to dis perse the va pors and to pro tect per son ­nel at tempt ing to stop a leak. Wa ter spray may be used to flush spills away from ar eas of po ten tial ig ­ni tion.
Unusual fire and explosion hazards:
Highly Flam ma ble. Prod ucts of com bus tion may con tain car bon mon ox ide, car bon di ox ide and other toxic ma te ri als.
DO NOT enter enclosed or confined space without proper protective equipment including respiratory protection.
Special fire fighting procedures:
Evac u ate non emer gency per son nel to a safe area.
Unusual fire and explosion hazards:
Fire fight ers should use self con tained breath ing ap pa ra tus. Avoid breath ing smoke, fumes, and de ­com po si tion prod ucts.
Use wa ter spray to drench smol der ing elas to mer. Prod uct may melt, af ter ig ni tion, to form flam ma ble liq uid.
page 12 - 2 EPV16J – 11089A
Spill or leak:
Re view fire and ex plo sion haz ards be fore pro ceed ­ing with clean up. Use ap pro pri ate per sonal pro tec ­tive equip ment dur ing clean up. Dike spill. Pre vent liq uid from en ter ing sew ers, wa ter ways, or low ar eas. Soak up with saw dust, sand, oil dry or other ab sor ­bent ma te rial. Shovel or sweep up.
Remove source of heat, sparks, flame, impact, friction or electricity including internal combustion engines and power tools. If equipment is used for spill cleanup, it must be explosion proof and suitable for flammable liquid and vapor.
Chapter 12. Fire Fighting & Chemical Control
CAUTION
DANGER
DANGER
NOTE
Vapors released from the spill may create an explosive atmosphere.
Waste disposal method:
Treat ment, stor age, trans por ta tion and dis posal must be in ac cor dance with ap pli ca ble fed eral, state, pro vin cial, and lo cal reg u la tions.
DO NOT flush to surface water or sanitary sewer system. By itself, the liquid is expected to be a RCRA ignitable hazardous waste.
Hydraulic Oil (UN 1270)
Extinguishing media:
Use wa ter spray, dry chem i cal, foam, or CO2.
Special fire fighting procedures:
Wa ter or foam may cause froth ing. Use wa ter to keep fire ex posed con tain ers cool. Wa ter spray may be used to flush spills away from ex po sures.
Unusual fire and explosion hazards:
Prod ucts of com bus tion may con tain car bon mon ­ox ide, car bon di ox ide, and other toxic ma te ri als.
DO NOT enter enclosed or confined space without proper protective equipment including respiratory protection.
Spill or leak:
Con tain spill im me di ately in small est area pos si ble. Re cover as much of the prod uct it self as pos si ble by such meth ods as vac u um ing, fol lowed by soak ­ing up of re sid ual flu ids by use of ab sor bent ma te ri ­als.
Re move con tam i nated items in clud ing con tam i ­nated soil and place in proper con tain ers for dis ­posal. Avoid wash ing, drain ing or di rect ing ma te rial to storm or san i tary sew ers .
Dis pose of non-recyclable ma te rial as a RCRA haz ard ous waste by such meth ods as in cin er a tion, com ply ing with fed eral, state, and lo cal reg u la ­tions.
Liquefied Petroleum Gas (UN 1075)
Extinguishing media:
Wa ter spray. Class A-B-C or BC fire extinguishers.
Special fire fighting procedures:
Stop flow of gas. Use wa ter to keep fire ex posed con tain ers cool. Use wa ter spray to dis perse un ig ­nit ed gas or va por.
If ig ni tion has oc curred and no wa ter avail able, tank metal may weaken from over heat ing. Evac u ate area. If gas has not ig nited, LP gas liq uid or va por may be dis persed by wa ter spray or flood ing.
Unusual fire and explosion hazards:
Highly Flam ma ble. Prod ucts of com bus tion may con tain car bon mon ox ide, car bon di ox ide and other toxic ma te ri als.
DO NOT enter enclosed or confined space without proper protective equipment including respiratory protection.
Spill or leak:
Keep pub lic away. Shut off sup ply of gas. Elim i nate sources of ig ni tion. Ven ti late the area. Dis perse with wa ter spray.
Con tact be tween skin and these gases in liq uid form can cause freez ing of tis sue caus ing in jury sim i lar to ther mal burn.
NOTE
Vapors released from the spill may create an explosive atmosphere.
Waste disposal method:
Treat ment, stor age, trans por ta tion and dis posal must be in ac cor dance with ap pli ca ble fed eral, state, pro vin cial, and lo cal reg u la tions.
Waste disposal method:
Re cy cle as much of the re cov er able prod uct as pos si ble.
EPV16J – 11089A page 12 - 3
Motor Oil (UN 1270)
Extinguishing media:
Use wa ter spray, dry chem i cal, foam, or CO2.
Chapter 12. Fire Fighting & Chemical Control
DANGER
Special fire fighting procedures:
Wa ter or foam may cause froth ing. Use wa ter to keep fire ex posed con tain ers cool. Wa ter spray may be used to flush spills away from ex po sures.
Unusual fire and explosion hazards:
Prod ucts of com bus tion may con tain car bon mon ­ox ide, car bon di ox ide, and other toxic ma te ri als.
DO NOT enter enclosed or confined space without proper protective equipment including respiratory protection.
Spill or leak:
Con tain spill im me di ately in small est area pos si ble. Re cover as much of the prod uct it self as pos si ble by such meth ods as vac u um ing, fol lowed by soak ­ing up of re sid ual flu ids by use of ab sor bent ma te ri ­als.
Re move con tam i nated items in clud ing con tam i ­nated soil and place in proper con tain ers for dis ­posal. Avoid wash ing, drain ing or di rect ing ma te rial to storm or san i tary sew ers .
Waste disposal method:
Re cy cle as much of the re cov er able prod uct as pos si ble.
Dis pose of non-recyclable ma te rial as a RCRA haz ard ous waste by such meth ods as in cin er a tion, com ply ing with fed eral, state, and lo cal reg u la ­tions.
page 12 - 4 EPV16J – 11089A

Chapter 13. Operator's Troubleshooting

CAUTION
Troubleshooting
All of the ac tions de scribed in this chap ter may be per formed by an EPV16J op er a tor, a trained and qual i fied ser vice tech ni cian is not re quired.
The first col umn, of the fol low ing chart, lists some com mon prob lems en coun tered by EPV16J op er a ­tors.
The sec ond col umn lists some of the causes for each prob lem. The third col umn lists rem e dies.
Operator Troubleshooting Chart
Problem Cause Remedy
Any problem that cannot be fixed by actions listed below should be referred to a trained and qualified EPV16J service technician.
Engine will not crank.
Engine cranks but will not start.
Engine runs but no outrigger function.
Engine runs but no boom function.
1. Flat battery. Replace / charge battery.
2. Main circuit breaker, in ground control box, has tripped..
3. Loose battery terminals . Tighten battery leads at battery.
1. Out of fuel. Fill the engine with the correct type / grade of
2. Fuel tap off. Locate fuel tap on engine and turn to ON.
1. Leg / boom switch in lower control box incorrectly set
1. Speed control set too SLOW.
2. Stabilisers not set correctly.
3. Lack of hydraulic oil. A. Check hydraulic system for leaks.
Reset circuit breaker , then try to start the engine. If it will not start, refer the problem to a qualified service technician.
fuel.
Switch to Stabilisers to operate stabilisers.
Turn Speed Control C.W. until function starts.
All stabilisers must be set on firm ground before boom functions will operate.
B. Top up the oil tank with the correct type
/ grade of hydraulic oil.
Bleed down at platform inoperative.
EPV16J – 11089A page 13 - 1
1. Flat battery. A. Charge / replace the battery.
B. Use Manual Bleed Down from lower
station.
Chapter 13. Operator's Troubleshooting
page 13 - 2 EPV16J – 11089A

Index

A
AC outlet RCD/ELCB, 7-6 Additional information
see Introduction - page iv
Automatic Shut-offs
Circuit Breakers
Main Circuit Breaker, 5-1
Stabilisers, 5-1
B
Battery fluid level, 7-3 Battery terminals, 7-3 Bolts and fasteners, 7-4 Booms Identification, 3-3
C
Controls
Control switches
Anti-Restart, 6-4, 8-4, 9-1 Boom Speed, 6-2, 6-4 Choke/Cold Start, 6-2, 6-4, 8-2, 8-4 Emergency Lower, 6-4 Emergency Stop, 6-2, 6-4, 8-1 Emergency Stop switch, 8-2, 8-4, 9-1 Foot Switch, 6-4 Jib Boom, 6-2, 6-4 Lift Enable, 6-2 Lower Boom, 6-2, 6-4 Master Key Switch, 6-2, 7-1, 8-2, 8-3, 9-1 Platform Rotate, 6-4 Platform/Ground Selector, 6-2, 8-2, 8-3, 9-1 Slew, 6-2, 6-4 Stablizer / Boom Selector Switch, 6-2 Upper Boom, 6-2, 6-4
Ground Control Box, 6-2
Control switches, 6-2 Controls location illustration, 6-3
Platform Control Box
Control switches, 6-4
Controls location illustration, 6-5 Controls and Control Decals Locations, 6-1 Crushing hazard, 1-2
E
Electrical
Electrocution, 1-1, 8-1
Electrical Hazard Warning
see Electrical Hazard - page i
Emergency lower, 7-5
Emergency Operation, 9-1
Operation From Ground Control Box, 9-2 Operation From Platform Control Box, 9-1 Procedures, 9-1
Engine
Cooling system, 3-2 Displacement, 3-2 Engine oil level, 7-2 Fuel, 3-2 Fuel consumption, 3-2 Fuel grade, 3-2 Fuel leaks, 7-2 Fuel tank cap, 7-2 Ignition system, 3-2 Make, 3-2 Model, 3-2 Oil capacity, 3-2 Oil grade, 3-2 Type, 3-2
F
Falling hazards, 1-1 Flashing light, 7-5
G
Gauges
Hourmeter, 4-1 Hydraulic Oil Level, 4-1
Level Bubble, 4-1 General Specifications, 3-1 Ground Control Box Controls, 6-3
H
Hazardous Components, 12-1
Battery, Lead/Acid (UN 2794), 12-1
Gasoline (UN 1203), 12-2
Hydraulic Oil (UN 1270), 12-3
Motor Oil (UN 1270) , 12-3 Hydraulic oil
Filler cap, 7-3 Hydraulic oil level, 7-3
I
Inspection
Operators daily inspection, 7-1
Inspection and Maintenance Table, 7-1
Insulation rating, 3-1
L
Left side view of machine, 3-4
EPV16J – 11089A index 1
Index
Light Flashing, 7-5 Lower control box, 7-5
M
Maintenance personnel
see Introduction - page iii Maximum height to basket floor, 3-1 Maximum outreach, 3-1 Maximum outreach height, 3-1 Minimum Safe Approach Distance
see Electrical Hazard - page ii
N
Nomenclature And Serial Numbers, 3-3
O
Operating Procedures, 8-1
Control Stations, 8-1
Emergency Stopping, 8-1
Moving The Platform, 8-4
Starting From Ground Control Box, 8-2
Starting From Platform Control Box, 8-3 Operation, 8-1 Operators
Qualified, 7-1, 8-2 Other Safety Devices, 2-1 Overall height, 3-1
P
Placards and decals, 7-6
Inspection drawing, 7-7
Standard placards and decals, 7-6 Platform
Foot switch, 8-5
Lanyard anchor points, 7-4 Platform Control Box Controls, 6-5 Platform size, 3-1 Pre-operational Inspection Table, 7-1 Pre-start Inspection, 1-1
Q
Qualified operators
see Introduction - page iii
R
RCD/ELCB Outlet (option), 5-1 Responsibilities of owners and users
see Introduction - page iv Right side view of machine, 3-3
S
Safe Operation, 1-1 Safe working load, 3-1 Safety Decals and Placards, 1-3
Location illustration, 1-4
Safety Devices
Bubble level, 2-2 Emergency Stop Switches, 2-1 Flashing light, 2-3 Foot switch, 2-2 Gravity gate, 2-2 Guardrails, 2-2 Lanyard anchor points, 2-1 RCD/ELCB AC outlet, 2-3 Safety Device Information, 2-1
Safety precautions
Fuel Handling Precautions, 1-3 Mounting and Dismounting Precautions, 1-2 Operating Precautions, 1-2 Operator, 1-2 Operator Maintenance Precautions, 1-3 Personnel Precautions, 1-2
Starting and Stopping Precautions, 1-2 Sandblast protection kit, 8-1 Securing for Day, 8-6 Signs, Caution, Danger, Notes
see Introduction - page iii Standard colour, 3-1 Stowing the EPV16J, 10-1
Boom lock pins, 10-1
Boom restraints and keepers, 10-1 Structural damage and welds, 7-4
Boom welds, 7-4
T
Tipover hazard, 1-1 Travelling height, 3-1 Troubleshooting, 13-1
Operator Troubleshooting Chart, 13-1 Turntable rotation, 3-1
W
Warranty - Limited
see inside front cover Weight, 3-1 Wiring harnesses, 7-2
Loose connections, 7-2 Work Place Inspection and Practices, 1-1 Working Envelope EPV16J, 3-3 Working height, 3-1
index 2 EPV16J – 11089A